Project Job Ref.

Dang
Section Sheet no./rev.
Home
1
Calc. by Date Chk'd by Date App'd by Date
DM 2/8/2021

WIND LOAD (ASCE 7 – 05)


TEDDS calculation version 1.2.04

Classification summary
Structure is a building
Structure is Rigid
Mean roof height; h = 20.200 m
Horizontal dimension parallel to wind; L = 60.000 m
Horizontal dimension normal to wind; B = 216.000 m
Wind force resisting element is part of main wind force resisting system
Structure is enclosed
Structure is not low rise
Procedure
Occupancy category (table 1-1); Category = 2
Basic wind speed (sect. 6.5.4); V = 40.5 m/s
Region; Non-Hurricane Prone
Importance factor ( table 6-1); I = 1.00
Exposure category (sect. 6.5.6); C
Wind directionality factor; Kd = 0.85
Topographic factor; Kzt = 1.00
Design procedure - analytical procedure (Method2)
Velocity pressure at mean roof height ‘h’(ASCE 7-05, cl. 6.5.10)
Case of loading system (table 6-3); Case = 2
Velocity pressure exposure coefficient; Kh = 1.16
Velocity pressure at mean roof height ‘h’; qh = 0.613N/m2× Kh × Kzt × Kd × V2 / (1m/s)2 × I = 988 N/m2

Design wind pressure for leeward or side walls of MWFRS in enclosed or partially enclosed rigid structures
Velocity pressure at mean roof height ‘h’; qh = 988 N/m2
External and internal pressure coefficients
Gust effect factor (sect 6.5.8); G = 0.85
Wall external pressure coefficient (fig. 6-6); Cp = -0.70
Positive internal pressure coefficient (fig. 6-5); GCpi_pos = 0.18
Negative internal pressure coefficient (fig. 6-5); GCpi_neg = -0.18
Design wind pressure (eq. 6-17)
With positive GCpi; pmax = qh × G × Cp - qh × GCpi_pos = -766 N/m2
With negative GCpi; pmin = qh × G × Cp - qh × GCpi_neg = -410 N/m2
Note: - As per Section 6.1.4.1, the wind load to be used in the design of the MWFRS shall be not less than 479 N/m2
multiplied by the area of the building or structure projected onto a vertical plane normal to the wind direction.
Project Job Ref.

Dang
Section Sheet no./rev.
Home
2
Calc. by Date Chk'd by Date App'd by Date
DM 2/8/2021

qh GCp qhGCp

qh GCp qz GCp θ

WIND qhGCp Z h qh GCp


B
qz GCp

qh GCp L
L ELEVATION
PLAN

GABLE, HIP ROOF

qhGCp qhGCp
qh GCp

θ θ
qhGCp
qz GCp qz GCp

WIND
B qhGCp
qz GCp
h h

qhGCp

qh GCp

L L L
PLAN ELEVATION ELEVATION

MONOSLOPE ROOF (NOTE 4)

qhGCp qhGCp
qh GCp

θ
qhGCp
qz GCp

WIND
B qhGCp
qz GCp

qhGCp
L
L
PLAN ELEVATION

MANSARD ROOF (NOTE 8)