You are on page 1of 1

VERTEDERO_"V"120°_SALIDA_CAJA_DISTRIBUCIÓN_CAUDAL_MEDIO_AÑO10

Project Description
Solve For Headwater Elevation

Input Data

Discharge 0.131700 m³/s


Crest Elevation 81.0000 m
Tailwater Elevation 80.83 m
Coefficient of Discharge 0.57
Angle 120.0000 degrees

Results
Headwater Elevation 81.32 m
Headwater Height Above Crest 0.32 m
Tailwater Height Above Crest -0.17 m
Flow Area 0.17 m²
Velocity 0.76 m/s
Wetted Perimeter 1.27 m
Top Width 1.10 m

Bentley Systems, Inc. Haestad Methods Solution Center


Bentley FlowMaster V8i (SELECTseries 1) [08.11.01.03]
9/11/2017 1:18:09 p. m. 27 Siemons Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666 Page 1 of 1