Red Tail is a series of energy storage-based Voltage Loss Compensator (VLC) systems.
Includes: Raptor power converter cabinet(s), system cabinet, and energy storage cabinet(s).
Featuring: ultra-fast response time, high efficiency, and ultracapacitors for energy storage.
Applications: voltage sag compensators, industrial UPS, dual source and generator bridging.
AC Input Mechanical
200 / 208 / 220
Nominal Voltage Cabinet Light beige powder-coated
380 / 400 / 415
Construction galvanneal cabinet
460 / 480 VAC
Three phase wye
(4 wires plus ground) Fail Safe Bypass Optional
Source Type
consult factory for other
types.
Operating Voltage Maintenance Bypass Optional
± 10 % of nominal
Range (static
(adjustable)
bypass)
Cabinet
NEMA 1 / IP 20 (for use in
Nominal Operating Environmental
50 / 60 Hz (auto select) protected indoor environments)
Frequency Rating
Top
Power Factor 0.5 lagging to 0.9 leading Cable Entry
(consult factory for other options)
Maximum Crest
2
Factor Audible Noise @ 2 m < 75 dB
120 % for 60 s
150 % for 30 s Energy Storage Ultracapacitors
Overload Capacity
200 % for 10 s
(static bypass)
300 % for 5 s
500 % for 1 s
Environment
0 – 2,000 m above sea level
AC Output Operating Altitude
(without derating)
Voltage Sag &
Momentary Three-phase: 90-0 %
Interruption nominal for 2.5 sec Operating
0 – +40C
Protection (standard model) / Temperature
Magnitude and 5 sec (extended model)
Duration
0 – 90 % relative humidity
Operating Humidity
(non-condensing)
Three-phase: 115 % of
Voltage Swell
nominal for 2.5 sec
Communication
Maximum
125 / 250 / 375 / 500 kVA Communication
Continuous Power Ethernet / Modbus TCP
Protocol
Typical Efficiency
99 % (400 – 480V)
(50~100% load) Limited Warranty
98 % (200 – 380V)
2 Years, Parts % Labor
*Due to continual engineering improvement, specifications are subject to change without notice.
VLC- ---
Bypass switch
Momentary outage runtime
Options
(refers to Options table below)
208 / 400 / 480 [Nominal voltage]
Momentary
Duration of runtime under full load S: Standard 2.5
outage runtime
condition. X: Extended 5
(seconds)
N: None
Switch providing normal utility supply
F: Non-isolating manual fail-safe rotary bypass switch
Bypass switch to load for maintenance or in the
M: Manual maintenance bypass circuit breakers
event of equipment failure.
A: Automatic maintenance bypass circuit breakers
100 mm 100 mm
100 mm 100 mm
(3.9”) (3.9”)
(3.9”) (3.9”)
Type E Type F
Maintenance bypass Maintenance bypass
381 mm 762 mm
(15.0”) (30.0”)
2000 mm
2000 mm
(78.7”)
(78.7”)
100 mm 100 mm
(3.9”) (3.9”)
797 mm 797 mm
(31.4”) (31.4”)
381 mm 762 mm
(15.0”) (30.0”)
Maintenance
Rated kVA Runtime System layout Total Dimension (W x D x H)
bypass
LAN
Shop floor