You are on page 1of 1

DA-6000SS SPECIFICATIONS 6kVA GENERAL

The DCA series generators are complete, stand


alone generating sets. All models consist of an
GENERAL
alternator which is directly coupled to a diesel
Model DA-6000SS engine. The alternator and engine are set on a
Power Type common skid base. Special Vibration isolators
Diesel
are used to minimize vibrations during opera
Output Continuous/Standby (kVA) 5.5
tion. The generator and electrical components
are fully enclosed in a solid steel, weatherproof
canopy. Noise suppression is achieved by using
ENGINE

Engine Make and Model Kubota Z482 50HZ/60HZ OPERATION


Engine Type 4 cycle, Water-cooled, The DCA series can be operated at either 50Hz
Swirl chambered or 60Hz by simply adjusting the engine speed
Rated Output (kW/min -1) 6.5/3000 using the throttle control knob on the control
Battery Type 12V-35AH panel.
Bore (mm) x Stroke (mm) 67 x 68
AUTO FUEL AIR EXTRACTOR
Number of Cylinders 2
Air trapped in the fuel system can be trouble
Piston Displacement (L) 0.479 some, however, with the DCA series, fuel air
Fuel Tank Capacity (L) 25 extraction is automatically performed by simply
Fuel Consumption (L/h) 2.1 operating the starter switch, without the need
for tools or devices. There is no soiling of the
*Fuel Consumption is based on 75% load.
machines interior or the operator’s hands and
the outflow of fuel to the machines exterior
is prevented. The machine will start after the
engine is turned over a few times.
ALTERNATOR

Frequency (Hz) 50 EXTREMELY QUIET OPERATION


Rated Output (kVA) 5.5 In urban areas and at the worksite, there is an
Rated Voltage (V) 115/230 ever increasing demand for reduced noise.
3000 The DCA series generators are extremely quiet
Rotating Speed (RPM)
when operating at full load.
Exciter Type Revolving Field, Self-Exciting
new Brushless
CLEAN ENGINES
Voltage regulation (%) +1.5 The engines used in these generators meet all
Number of Phases Single Phase 3 wire Californian Atmospheric Pollution standards,
Power Factor 1.0 which is one of the world’s most stringent an
Insulation Class F tipollution standards. This is achieved by using
a PCV purge control valve system. Therefore,
these engines do not discharge blow-by gas
to the outside, which keeps the interior of the
UNIT machine cleaner and the exhaust emissions are
minimized.
Dimensions LxWxH (m) 1140 x 650 x 795
Dry Weight (kg) 239
Sound at 7m/dB (A) 3000RPM 61

SPECIAL FEATURES
FULLY APPOINTED CONTROL PANELS
Tachometer Voltage Regulator
AC Ammeter Frequency Meter
AC Volt meter Throttle Handle
Pilot Lamp Preheat Lamp
Voltmeter Change-Over Swith Battery Switch
Panel Light Emergency Stop Button
Synchronising Lamp Starter Switch
Single Parallel Change-Over Switch Warning Lamp Unit
Circuit Breaker Charging Ammeter
Panel Light Switch Oil Pressure Gauge
Ammeter Change-Over Switch Water Temperature Gauge

Specifications and characteristics are subject to change without notice. Access Hire Australia Pty Ltd retains the right to interpret.