You are on page 1of 4

Schindler 3300 XL Machine Room-Less (MRL)

Specifications and Layout Data


Schindler 3300XL Machine Room-Less (MRL)
Power Factor 1 Regenerative Drive Standard
Capacity 3,500 – 5,000 lbs. Hatch plans:
Passengers 21 – 31 General Purpose
Speed 150 – 200 fpm Front opening single-speed Front/rear opening single-speed
Travel height Up to 108’ and 13 stops, 24 openings center opening (SSCO) center opening (SSCO)
Cab height 7’-9”, 9’, 10’ (7’-9” shown) F F
Door height 7’, 8', 9’ (7’ shown) 8
A A
F
B B
Hoistways G G
A
Front opening Front/rear opening

B
G
D D

Front opening two-speed 1 Front/rear opening two-speed 1


left opening (2SSO) left opening (2SSO)
D
F F

F
A
C E I C E I F A

A B
G
B
G
A

B
B
G
G
D D

D Hospital/Service
D
Front opening two-speed 1 Front/rear opening two-speed 1
left opening (2SSO) left opening (2SSO)

F F

A
A
E J E E J
B
B
G G

H H

D D

F
F
Abbreviations:
A Cab width D Door width G Hoistway depth SSCO Single speed center opening door
A
B Cab depth E Door height 8 H Pit depth 2SSO Two speed side opening door 1A
C Car height F Hoistway width I Clear overhead
B B
G
2 Schindler 3300 XL Layout Data
G
General Purpose, Hospital/Service, HS AIA
Specifications and Layout Data
Cab Cab Door Hoistway Hoistway Clear Pit
Width Depth Width Width Depth Overhead 4 Depth

Load
Door Speed Height
Capacity
Type fpm (m/s) ft-in (mm)
lbs (kg)
Front only Front & Rear PU Buffer Spring Buffer PU Buffer Spring Buffer
ft-in (mm) ft-in (mm) ft-in (mm) ft-in (mm)
ft-in (mm) ft-in (mm) Minimum 9 Minimum Minimum 9 Minimum
ft-in (mm) ft-in (mm) ft-in (mm) ft-in (mm)

General Purpose
6’-4 9/16” 5’-6 15/16” 3’-6” 8’-4” 6’-11 1/16” 7’-4 1/2” 7’-9” 12’-7” 9 12’-11 1/4” 4‘-0” 9 4‘-0”
(1945) (1700)
SSCO (1067) (2540) (2110) (2248) (2362) (3835) (3942) (1219) (1219)
3,500
(1,590)
6’-4 9/16” 5’-6 15/16” 3’-6” 8’-4” 6’-11 1/16” 7’-7 11/16” 150 9’-0” 13’-10” 9 14’-2 1/4” 4‘-0” 9 4‘-0”
(1945) (1700)
2SSO (1067) (2540) (2110) (2328) (0.76) (2743) (4216) (4323) (1219) (1219)

4,000 7’-4 3/16” 5’-7” SSCO 4’ 9’-4” 6’-8 1/8” 7’-4 3/16” 10’-0” 14’-10” 9 15’-2 1/4” 4‘-0” 9 4‘-0”
(1,815) (2240) (1700) (1219) (2843) (2035) (2240) (3048) (4521) (4628) (1219) (1219)

Hospital Service 7’-9”


(2362)
12’-8” 9
(3858)
13’-4 3/16”
(4068)
4‘-0” 9
(1219)
4‘-1 5/16”
(1219)

4,000 5’-4 1/4” 7’-8 1/2” 2SSO 4’ 7’-4” 8’-11 5/16” 9’-9” 200 9’-0” 13’-11” 9 14’-7 3/16” 4‘-0” 9 4‘-1 5/16”
(1,815) (1632) (2350) (1219) (2235) (2725) (2970) (1.02) (2743) (4239) (4449) (1219) (1219)

4,500 5’-4 1/4” 8’-2 1/2” 4’ 7’-4” 9’-5 3/16” 10’-2 7/8”
2SSO 10’-0” 14’-11” 9 15’-7 3/16” 4‘-0” 9 4‘-1 5/16”
(2,040) (1632) (2500) (1219) (2235) (2875) (3120) (3048) (4544) (4754) (1219) (1219)

5’-4 1/4” 8’-8 5/16” 4’ 7’-4” 9’-11 1/8” 10’-8 3/4”


(1632) (2650)
2SSO (1219) (2235) (3025) (3270)
5,000
(2,270) 7/8” 5/16” 1/2’
5’-10 8’-8 2SSO 4 8‘-0 15/16” 9’-11 1/8” 10’-8 3/4”
(1800) (2650) (1372) (2446) (3025) (3270)

5,000 AIA 5’-8 7/8” 9’-0 1/4” 4’ 7‘-8 5/8” 10’-3 1/16” 11’-0 11/16”
(2,270) (1750) (2750)
2SSO (1219) (2353) (3125) (3370)

Door height: 7', 8', 9' 8

Notes:
1. 2SSO doors are available with right or left openings. Optional hand (diagonal) door layout complies with stretcher access if needed. Please contact your local Schindler Sales Representative for
more information.
2. Up to four car group operation is available. Please consult with your local Schindler Sales Representative for more information.
3. For areas in seismic zone 2 or greater, provide additional 2” (50 mm) to the hoistway width.
4. Clear overhead is defined as from the lowest point below any obstruction such as: hoist beam(s), building beams, or roof structure.
5. Where permitted by code, no control closet is required. A 3-phase and 110v disconnect must be located in both the hoistway overhead and a location in the building outside of the hoistway.
The latter is not required to be an elevator-dedicated space.
6. Schindler recommends an additional 2” hoistway width to the minimums above, for non-seismic regions, and an additional 4” for seismic regions.
7. Cab heights available are 7’ 9”, 8’, or 9’. Subtract 4” from these dimensions to underside of canopy.
8. Door heights available are 7’, 8’, or 9’, except for 3,500 lb. configuration, where door height is 7’ only.
9. PU buffer requires a local code review. Please contact your local Schindler Sales Representative for additional PU buffer information.
10. These dimensions are for information only and cannot be used for construction purposes without Schindler confirmation. Confirm with your local Schindler Sales Representative.

Schindler 3300 XL Layout Data 3


SchindlerPlan.com
Elevator and escalator design in minutes

Schindler Plan is an easy-to-use online planning tool that makes it simple to configure your elevator
or escalator in minutes. Good elevator or escalator design plays a critical role in the quality of life and
work in multi-story buildings. Schindler Plan was developed to enable accurate escalator or elevator
preparation early in a project’s life cycle.

For more information, including the location of


the Schindler office nearest you, please visit:

U.S. Headquarters. Morristown, New Jersey


Tel. 973.397.6500
Schindler is a member organization of the
www.us.schindler.com
U.S. Green Building Council.

Canada Headquarters. Toronto, Ontario


3300 XL LD BRO WF2 0121

Schindler has received renewal to ISO 9001 and


Tel. 416.332.8280
ISO 14001 certificates.
www.ca.schindler.com

Schindler prints with vegetable-based ink on


paper containing post-consumer waste fiber.

You might also like