Professional Documents
Culture Documents
AKKREDITERING
MSYS 001
NEK KABEL AS
100 years!
1913 - 2013
Since 1913 NEK Kabel has designed and manufactured cable for a wide
range of applications.
The superior mud compound being used, can be added onto any cable,
making them resistant to such extreme environments.
NEK Kabel is today represented in Norway, Finland, and the Far East,
permitting the company to deliver cable directly from a warehouse close
to the market.
NEK Kabel AS Luhrtoppen 2, PB 186, 1470 Lørenskog Tlf. +47 67 91 21 80 Fax. +47 67 91 21 90 3
NORSK
AKKREDITERING
MSYS 001
NEK KABEL AS
Index
Lan Cables page
Cat 5E Megaline SF/UTP Lan Cable UV-resist. LSZH Offshore network cable 4x2xAWG24/1 4
Cat 5E Megaline SF/UTP MUD resistant, LSZH Offshore network cable 4x2xAWG24/1 5
LanMarin Cat 7 SSTP Flex UV Resistant 4x2xAWG23/7 6
LanMarin Hybrid Cat7 S/FTP Flex + 2 OS2 SM fibres UV resistant 4x2xAWG23/7 7
LanMarin MUD-resistant Cat7 SSTP Flex MUD and UV resistant 4x2xAWG23/7 8
LanMarin Armoured Cat7 S/FTP Flex MUD and UV resistant 4x2xAWG23/7 9
BUS Cables
Canbus Marin DNV (1 or 2)x 2 x 0.75/0.75mm² 10
Profibus Marin LSZH SHF2 1 x 2 x 0.35mm² (1x2x0.76mm) 11
Profibus Marin SHF1 + MUD 1 x 2 x 0.35mm² (1x2x0.76mm) 12
Coaxial 50 Ohm
RG215 Marine 50 Ohm Coaxial cable LSZH 13
RG58CU Marine SHF1 (MUD) 50 Ohm Coaxial cable LSZH/MUD 14
RG58CU Marine SHF1 ARM (MUD) 50 Ohm Coaxial cable LSZH/MUD 15
RG213U Marine SHF1 (MUD) 50 Ohm Coaxial cable LSZH/MUD 16
RG213U Marine SHF1 ARM (MUD) 50 Ohm Coaxial cable LSZH/MUD 17
RG214U Marine SHF1 (MUD) 50 Ohm Coaxial cable LSZH/MUD 18
RG214U Marine SHF1 ARM (MUD) 50 Ohm Coaxial cable LSZH/MUD 19
Coaxial 75 Ohm
RG59BU Marine SHF1 (MUD) 75 Ohm Coaxial cable LSZH/MUD 20
RG59BU Marine SHF1 ARM (MUD) 75 Ohm Coaxial cable LSZH/MUD 21
RG 59 Flex 75 Ohm Flexible Coaxial cable 22
RG6AU Marine SHF1 (MUD) 75 Ohm Marine and ship inst. cable LSZH/MUD 23
RG6AU Marine SHF1 ARM (MUD) 75 Ohm Marine and ship inst. cable LSZH/MUD 24
RG11AU Marine SHF1 (MUD) 75 Ohm Marine and ship inst. cable LSZH/MUD 25
RG11AU Marine SHF1 ARM (MUD) (RG12) 75 Ohm Marine and ship inst. cable LSZH/MUD 26
RG 11 MUD-NAVY 75 Ohm offshore and ship inst. MUD-resistant and LSZH 27
SAT 22 ITV-Cable LSZH and UV-resist, RG 59B/U+0x0.75mm² 28
Fibre Cables
AICI In- and outdoor Armoured industrial cable, LSZH steel wire braid, tight buffer 29
AIAI In- and outdoor Armoured industrial cable, LSZH steel wire braid, tight buffer 31
QFCI In- and outdoor LSZH, loose tube 32
QFCI - MUD In- and outdoor Intinsic safety, loose tube LSZH 33
4 NEK Kabel AS Luhrtoppen 2, PB 186, 1470 Lørenskog Tlf. +47 67 91 21 80 Fax. +47 67 91 21 90
NORSK
AKKREDITERING
MSYS 001
NEK KABEL AS
Bruksområde/Application: Construction:
Offshore datakabel med skjerm og armering for installasjon der det er
krav til armering. Kabelen er UV-bestandig for utendørs installasjon. Conductor: 1 Bare Cu-wire, AWG 24/1
Kabelen er DNV godkjent. Insulation: 2 Celluar PE, nom Ø 1,1mm
colourcode: IEC
Installation cable for generic cabling systems acc. ISO/IEC 11801
Twisting element: Pair - 4 pairs
and EN 50173 (2.edition) as well as ISO/IEC 24072 and EN 50173-3
(draft). Ideal for all applications of class D up to 1 GbE acc. IEEE 802.3
Overall screen: Al-bonded polyester tape, and
3
ab, VoIP, PoE. The cable is UV-resistant and for indoor and outdoor tinned Cu-wire braid
installations. The cable is DNV-approved. Inner sheath: 4 2 layer LSZH compound, yellow
Armour: 5 Galvanised steel wire braid
Outer sheath: 6 Black, LSZH compound,
Electrical Specifications: UV resistant
Outer diam: 11,9 mm
Temperature installed: -40 to +60 [°C]
Weight: approx. 194 kg/km
Temperature @ installation: 0 to + 50
Rated voltage: 125 [V]
Test voltage: 1000 [V]
DC resist. max: 95 [W/km] 1 Bare Cu-wire
Insulation resitance: 5 [GW x km] 2 Cellular PE
3 Al-polyester tape
Mutual capacitance: 45 [pF/m] and tinned Cu-braid
Transfer capacitance: 1500 [pF/km 4 2-layer LSZH com-
pound, yellow
Characteristic impedance: 100±5 [W]@100MHz 5 Galvanished steel
Attenuation: see table wire braid
Velocity factor: 0,75 6 Black, LSZH comp.
Min. bending radius installed: 4 x outer diam UV-resist.
Min. bending radius @installation: 8 x outer diam
Norms:
Flame retardant: IEC 60332-1-2
Halogen acid gas emission: IEC 60754-1/2
Smoke density: IEC 61034-1/2 El.nr : 1089635
Prod.no: 7KS5005U
Approval: DNV (Det Norske Veritas)
RoHS
NEK Kabel AS Luhrtoppen 2, PB 186, 1470 Lørenskog Tlf. +47 67 91 21 80 Fax. +47 67 91 21 90 5
Modified: Mar. 12. 2014
NORSK
AKKREDITERING
MSYS 001
NEK KABEL AS
Bruksområde/Application: Construction:
Offshore datakabel med skjerm og armering for installasjon der det
er krav til armering. Kabelen er også godt egnet for utendørs instal- Conductor: 1 Bare Cu-wire, AWG 24/1
lasjon. Kabelen er basert på vår DNV-godkjente Cat 5E Megaline Insulation: 2 Cellular PE
SF/UTP HHQH med en MUD-bestandig i h.h.t NEK TS 606 yt- colourcode: IEC
terkappe. Twisting element: Pairs - 4 pair
Overall screen: 3 Al- polyester tape and
Installation cable for generic cabling systems acc. ISO/IEC 11801 tinned Cu-braid
and EN 50173 (2.edition) as well as ISO/IEC 24072 and EN 50173- Inner sheath: 4 2-layer halogenfree and flame-
3 (draft). Ideal for all applications of class D up to 1 GbE acc. IEEE retardent compound, yellow
802.3 ab, VoIP, PoE. For indoor and outdoor installations. Outer Armour: 5 Galvanised steel-wire braiding
jacket is MUD-resistant. Based on the DNV approved Cat.5E Mega-
Outer sheath: 6 Black MUD resist. PUR, halogene-
line SF/UTP LSOH, with a MUD-resistant acc. to NEK TS 606 outer
jacket.
free and flameretardent compound
Outer diam: 11,9mm
Weight: Approx. 195 kg/km
Electrical Specifications:
1 Bare Cu-wire
Temperature installed: -40 to +60 [°C] 2 Cellular PE
Temperature @ installation: 0 to +40 [°C] 3 Al-polyester tape
and tinned Cu-braid
Insulation resist. min.: 5 GW x km] 4 2-layer LSZH com-
DC resistance max.: 95 W/km] pound, yellow
5 Galvanished steel
Characteristic impedance: 100±5 [W @/100MHz] wire braid
Attenuation: see table
6 Black, MUD-resist
Velocity factor: 0,75 PUR, LSZH comp.
Min. bending radius @ inst.: 8 x outer diam.
Min. bending radius installed: 4 x outer diam.
Normer:
Elnr: 1089636
Flameretardance acc: IEC 60332-1-2
Halogene acid gas emotion acc: IEC 60754-1/2 Prod.no: 7KS5004U
Free of hazardious substances acc: RoHS 2002/95/EG
Oil resistance acc: EN 60811-2-1
Ozone resist. acc: EN 608111 RoHS
Resist. against microbes acc.: DIN VDE 0282
Hydrolytic acc: DIN 53504
Free of silicone oil that could
influence paintspraying.
Resistant to chemicals.
UV resististant.
6 NEK Kabel AS Luhrtoppen 2, PB 186, 1470 Lørenskog Tlf. +47 67 91 21 80 Fax. +47 67 91 21 90
Modified: Mar. 12. 2014
NORSK
AKKREDITERING
MSYS 001
NEK KABEL AS
LanMarin
Cat7 SSTP Flex
UV resistant
4x2xAWG23/7
Bruksområde/Application: Construction:
LanMarin er en høyhastighets datakabel med fler-trådete ledere, Cord: Stranded Cu, 0.28mm² (AWG23/7)
AWG23. Den har individuell parskjerm og felles flettet, fortinnet Insulation: Cellular PE, Ø1,5mm
skjerm. Kabelen oppfyller Cat7 kravene for 600MHz men er testet IEC
colourcode:
opp til 1000MHz. LanMarin er produsert etter de krav som gjelder
for skip og offshore, og er ment brukt som horisontal kabel. Kabelen Individual screen: Al-tape
oppfyller EMC-direktivet, er halogenfri og flammehemmet og med Overall screen: Tinned Cu-braid
gode kuldeegenskaper. Kabelen er godkjent og testet for klasse F-link. Waterblock:
LanMarin er DNV godkjent. Outer Jacket: Blue, black or grey crosslinked PE,
UV-resistant (SHF1)
High performance offshore LAN cable with flexible conductor, AWG23/7.
The cable is fully compliant with the category 7 standards, requiring Outer diam: 8±0.20mm
bandwiths up to 600MHz. STP cable consists of individually screened Weight: 97 kg/km
pairs with an overall braid. It complies to the EMC requirements for
screened cables. The cable is tested for high-frequency and transmis- Outer jacket
sion measurements for class F-link. The cable is DNV-certified. Waterblock
Conductor, stranded Cu
Insulation
Individual screen
Overall screen
Electrical Specifications:
Temperature range: -40 to +80 [°C]
Test voltage: 1 [kV]
Prod. no: 1089698 blue
Insulation resistance: >_ 500 [MW x km] Prod. no: 1089725 black
Resistance of the conductor: >_ 69,5 [W/km] Prod. no: 1089726 grey
Impedance: 100±5 [W] v/ 100MHz
Nom. capacitance: 55 [pF/m]
Attenuation: see table
Velocity factor: 0,78
Min. bending radius: 31 x outer diam.
Norms: RoHS
Oil and fuel resist acc.: IEC 60811
Water resist. acc.: IEC 60502
Weathering and UV resist acc.: IEC 60228
Fire propagation complying with: IEC 60332-3-24C
Halogene acid gas emotion acc: IEC 60754-1/2
Standard: EN 50288-4-2 Tips This cable can also be delivered
MUD resistant acc. to NEK TS 606
Approvals: DNV- and ABS-certified
Attenuation
Frequency NEXT Returnloss
Max.(acc.EN)
[MHz] [dB] [dB/100m]
[dB/100m]
1 2,2 100 35
4 3,8 100 31
10 5,9 95 38
16 7,4 90 32
20 8,4 90 32
31,25 10,5 90 31
62,5 15,3 85 27
100 18,1 82 34
155 23,2 80 28
200 26,6 77 25
300 33,3 71 23
600 50,1 67 21
NEK Kabel AS Luhrtoppen 2, PB 186, 1470 Lørenskog Tlf. +47 67 91 21 80 Fax. +47 67 91 21 90 7
Modified:
Modified: Mar.
Mar. 12.
12. 2014
2014
NORSK
AKKREDITERING
MSYS 001
NEK KABEL AS
LanMarin Hybrid
Cat7 S/FTP Flex + 2 OS2 SM fibres
UV resistant
4x2xAWG23/7
Bruksområde/Application: Construction:
Generisk dataoverføring. Denne kabelen er en Cat7 S/FTP-kabel Cord: Stranded Cu, 0.28mm² (AWG23/7)
til bruk som installasjon/horisontal kabel i tøffere elektriske og Cellular PE, Ø1,5mm
Insulation:
mekaniske miljø, inkludert skip og offshore-enheter. Kabelen er
testet opp til 900MHz, og vil gi gode marginer for søknad som colourcode: IEC
10 Gigabit Ethernet med en båndbredde på opptil 500 MHz. Individual screen: Al-tape
Singlemode fiber 2 fiber kabel med aramid garn styrke, og opp- Overall screen: Tinned Cu-braid
fyller de nye ITU G.657 A2, G.657 B2 samt G.652.ABC og D. Outer Jacket: Black or grey crosslinked PE,
Fiberkabelen er meget fleksibel, velegnet til bruk som bl.a patchkabel
UV-resistant (SHF1)
og forbindelseskabel i “FTH” system. Fibrene imøtekommer de nye
ITU G.657 A2 og G.657 B2 spesifikasjon samt G.652.D. Outer diam: 8±0.20mm
Weight: 97 kg/km
Generic data transmission. This cable is a Cat7 S/FTP cable for
use as installation/horizontal cable in tougher electrical and me-
Outer jacket
chanical environment, including ships and offshore units. The
cable is tested up to 900MHz and will give good margins for ap- Conductor, stranded Cu
plication like 10 Gigabit Ethernet at a bandwith up to 500MHz. Insulation
Singlemode fiber 2 fiber cable with aramid yarns strength, fulfill Individual screen
the new ITU G.657 A2, G.657 B2 as well as G.652.A-B-C and D.
The fibrecable is very flexible, prefered for use in office installations, Overall screen
for patch cords, interconnection cable and for Fibre-to -the-Home Fibres
networks. The fibre fulfills the new ITU G657 A2, G.657 B2 specifica-
tion, as well as G.652.D.
Electrical Specifications:
Temperature range: -40 to +80 [°C]
Test voltage: 1 [kV] Prod. no: 1089727
Insulation resistance: >_ 500 [MW x km]
Resistance of the conductor: >_ 69,5 [W/km]
Impedance: 100±5 [W] v/ 100MHz
Nom. capacitance: 55 [pF/m] RoHS
Attenuation: see table
Velocity factor: 0,78
Min. bending radius: 31 x outer diam.
Norms:
Tips This cable can also be delivered
Oil and fuel resist acc.: IEC 60811
Water resist. acc.: IEC 60502 MUD resistant acc. to NEK TS 606
Weathering and UV resist acc.: IEC 60228
Fire propagation complying with: IEC 60332-3-24C
Halogene acid gas emotion acc: IEC 60754-1/2
Standard: EN 50288-4-2
Attenuation
Frequency NEXT Returnloss
Max.(acc.EN)
[MHz] [dB] [dB/100m]
[dB/100m]
1 2,2 100 35
4 3,8 100 31
10 5,9 95 38
16 7,4 90 32
20 8,4 90 32
31,25 10,5 90 31
62,5 15,3 85 27
100 18,1 82 34
155 23,2 80 28
200 26,6 77 25
300 33,3 71 23
600 50,1 67 21
8 NEK Kabel AS Luhrtoppen 2, PB 186, 1470 Lørenskog Tlf. +47 67 91 21 80 Fax. +47 67 91 21 90
Modified: Mar. 12. 2014
NORSK
AKKREDITERING
MSYS 001
NEK KABEL AS
LanMarin MUD-resistant
Cat7 SSTP Flex
MUD and UV resistant
4x2xAWG23/7
Bruksområde/Application: Construction:
LanMarin MUD-bestandig er en høyhastighets data-kabel med Cord: Stranded bare Cu, 0.28mm² (AWG23/7)
flertrådig ledere i AWG23. Den har MUD bestandig kappe som er Insulation: Cellular PE, Ø1,55mm
halogenfri og flammehemmet, med ekstra brann-sikker beskyttelse.
Kabelen oppfyller EMC direktivet. LanMarin har meget gode kulde- colourcode: IEC
egenskaper, for brukt som horisontalkabel innen offshore, samt i Pairs: Individual screened with Al-tape
krevende miljøer. Kabelen er godkjent og testet for klasse F-link. Overall screen: Tinned Cu-braid
LanMarin MUD er DNV sertifisert. Inner sheath: Fire barriere LSZH, Ø=8,2mm
Outer sheath: Black crosslinked PE,
MUD resistant high performance offshore LAN cable with individual
Al-foil, braided Cu-screen and with an additional fire resistant MUD- and UV resistant (SHF2)
protection. Outer jacket is flame retardant, low smoke, halogen free Outer diam: 10±0.2mm
MUD- and UV-resistant. This cable is for use as horisontal cable in Weight: 120 kg/km
tough electrical and mechanical environments. The cable fulfils the
EMC requirement. It has excellent cold resistant properties. The Outer jacket
cable is tested for high-frequency and transmission measurements Conductor, stranded Cu
for class F-link. LanMarin MUD is DNV certified. Insulation
Fire barriere
Electrical Specifications: Individual screen
Temperature range: -40 to +80 [°C] Overall screen
Test voltage dc: 1 [kV 1min.]
Insulation resistance: >_ 500 [MW x km]
Resistance of the conductor: >_ 69,5 [W/km]
Average characteristic Impedance: 100±5 [W] v/ 100MHz
Nom. capacitance at 800-1000Hz: 55 [pF/m]
Attenuation: see table Prod. no: 1089699
Velocity factor: 0,78
Min. bending radius installed: 31 [mm]
Loose: 62 [mm]
RoHS
.
Norms:
Oil and fuel resist acc.: IEC 60811
Water resist. acc.: IEC 60502
Weathering resist acc.: ASTM G 154
ASTM D 4587
EN ISO 11507
UV Radiation resist. acc. ASTM D 2565-92A
Fire retardant: IEC 60332-3 ABC
Halogene acid gas emotion acc: IEC 60754-1/2
Standard: EN 50288-4-2
MUD resistant acc.: NEK TS 606
Attenuation
Frequency NEXT Returnloss
Max.(acc.EN)
[MHz] [dB] [dB/100m]
[dB/100m]
1 2,2 100 35
4 3,8 100 31
10 5,9 95 38
16 7,4 90 32
20 8,4 90 32
31,25 10,5 90 31
62,5 15,3 85 27
100 18,1 82 34
155 23,2 80 28
200 26,6 77 25
300 33,3 71 23
600 50,1 67 21
NEK Kabel AS Luhrtoppen 2, PB 186, 1470 Lørenskog Tlf. +47 67 91 21 80 Fax. +47 67 91 21 90 9
Modified: Mar. 12. 2014
NORSK
AKKREDITERING
MSYS 001
NEK KABEL AS
Bruksområde/Application: Construction:
LanMarin MUD-bestandig er en høyhastighets data-kabel med Cord: Stranded bare Cu, 0.28mm² (AWG23/7)
flertrådig ledere i AWG23. Den har MUD bestandig kappe som er Insulation: Cellular PE, Ø1,55mm
halogenfri og flammehemmet, med ekstra brann-sikker beskyttelse.
Kabelen oppfyller EMC direktivet. LanMarin har meget gode kulde- colourcode: IEC
egenskaper, og er ment brukt som horisontalkabel innen offshore, Pairs: Individual screened with Al-tape
samt i krevende miljøer. Kabelen er godkjent og testet for klasse Overall screen: Tinned Cu-braid
F-link. LanMarin MUD er DNV sertifisert. Inner sheath: Fire barriere LSZH, Ø=8,2mm
Armour Galvanized steel wire braid
MUD resistant high performance offshore LAN cable with individual
Al-foil, braided Cu-screen and with an additional fire resistant Outer sheath: Black PE, MUD resistant
protection. Outer jacket is flame retardant, low smoke, halogenfree Outer diam: 11±0.2mm
MUD- and UV-resistant. This cable is for use as horisontal cable in Weight: 120 kg/km
tough electrical and mechanical environments. The cable fulfils the
EMC requirement. It has excellent cold resistant properties. The
cable is tested for high-frequency and transmission measurements
for class F-link. LanMarin MUD is DNV certified.
Outer jacket
Conductor, stranded Cu
Electrical Specifications: Insulation
Fire barriere
Temperature range: -40 to +80 [°C]
Individual screen
Test voltage dc: 1 [kV 1min.] Overall screen
Insulation resistance: >_ 500 [MW x km] Galvanized steel wire braid
Resistance of the conductor: >_ 69,5 [W/km]
Averege characteristic Impedance: 100±5 [W] v/ 100MHz
Nom. capacitance at 800-1000Hz: 55 [pF/m]
Attenuation: see table
Velocity factor: 0,78
Min. bending radius installed: 31 [mm] RoHS
Loose: .
62 [mm]
Norms:
Oil and fuel resist acc.: IEC 60811
Water resist. acc.: IEC 60502
Weathering resist acc.: ASTM G 154
ASTM D 4587
EN ISO 11507
UV Radiation resist. acc. ASTM D 2565-92A
Fire retardant: IEC 60332-3 ABC
Halogene acid gas emotion acc: IEC 60754-1/2
Standard: EN 50288-4-2
MUD resistant acc. to: NEK TS 606
Attenuation
Frequency NEXT Returnloss
Max.(acc.EN)
[MHz] [dB] [dB/100m]
[dB/100m]
1 2,2 100 35
4 3,8 100 31
10 5,9 95 38
16 7,4 90 32
20 8,4 90 32
31,25 10,5 90 31
62,5 15,3 85 27
100 18,1 82 34
155 23,2 80 28
200 26,6 77 25
300 33,3 71 23
600 50,1 67 21
10 NEK Kabel AS Luhrtoppen 2, PB 186, 1470 Lørenskog Tlf. +47 67 91 21 80 Fax. +47 67 91 21 90
Modified: Mar. 12. 2014
NORSK
AKKREDITERING
MSYS 001
NEK KABEL AS
Canbus Marin
SHF 2
1 x 2 x 0.75/0.75mm²
2 x 2 x 0.75/0.75mm²
Bruksområde/Application: Construction:
System bus kabel for åpen eller skjult installasjon. Kabelen har god Conductor: Stranded Cu- 0.75mm² (24x0.20mm)
olje-og kjemikaliebestandighet, grunnet SHF2 kryssbundet materiale i
Insulation: Foamed PE, Ø=2,95mm
ytterkappe. Kabelen er spesielt designet for CAN-bus systemer.
Inidvidual screen: Al-/polyester tape >100% coverage
System bus cable for use over or under deck. The cable has good Earth conductor: Tinned Cu, (24x0.20mm)
oil and chemical resistance, due to the special outerjacket of SHF2 Screen: Tinned Cu-braid >80% optical cover
cross linked compound. The cable is special designed for CAN-bus Wrapping: Flame barrier tape >100% cover
systems. Outer Jacket: Black, halogen free cross linked SHF2
1x2x0.75mm²: 11,1mm
Outer diam:
Weight: 200 kg/km
2x2x0.75mm²: 12,5mm
Electrical Specifications: Weight: 245 kg/km
Operating temperature: -40 to +90 [°C]
Operating voltage: 100 [V] Tinned Cu
Test voltage: 1000 [V] dc Dummies
Resistance inner conductor: <_ 26 [W/km] Al/polyester tape + tinned Cu braid
Insulation resistance: >_ 1 [GW x km] Stranded Cu
Foamed PE
Nom. capasitance @ 800Hz: 40 [pF/m] Flame barrier tape
Characteristic impedance @ 1MHz: 120 [W±10%] Outer jacket black halogenfree
Nom. attenuation @ 1MHz: <_ 13,2 [dB/km]
NEK Kabel AS Luhrtoppen 2, PB 186, 1470 Lørenskog Tlf. +47 67 91 21 80 Fax. +47 67 91 21 90 11
Modified: Mar. 12. 2014
NORSK
AKKREDITERING
MSYS 001
NEK KABEL AS
Bruksområde/Application: Construction:
Skjermet BUS-kabel sertifisert for bruk innen skip- og offshore- Conductor: Stranded bare Cu, 7x0.25
installasjoner. Kabelen er halogenfri, flammehemmet, oljebestandig og (AWG22), 0.35mm Ø=0.76mm
UV-beskyttet. Kabelen kan også leveres med ekstra forsterket mud- og
Insulation: Foamed PE, Ø=2.75mm
kjemikaliebestandig ytterkappe i h.h.t NEK TS 606
colour: Green and red
Shielded BUS-cable certified for use in ship and offshore installations. Screen: Al-/polyesterfoil 100% coverage
The cable is low smoke, zero halogen, oil- and UV-resistant. The and Tinned Cu-braid,>_ 60% optical
cable can also be delivered with an extra superior mud- and chemical coverage
resistant outer jacket, according to NEK TS 606. Outer jacket: Black, halogen free cross-linked
SHF2
Outer diam: Ø=8.6mm
Electrical Specifications: Weight: 95 kg/km
Temperature installed: -40 to +90 [°C]
Working voltage: 100 [V] Dummy
Test voltage: 1000 [V] dc
Stranded Cu
Resistant of the inner cond. <_ 55 [W/km] Foamed PE
Nom. capacitance at 800Hz: 30 [pF/m] Al/polyester foil + Tinned Cu-braid
Characteristic impedance: Outer jacket, black halogen free
3 - 20MHz: 150±15 [W]
38,4 MHz: 185±18,5 [W]
9,6MHz: 250±25 [W]
Nom. attenuation:
16MHz: _< 45 [dB/m] Prod. no: 1091038
4MHz: _< 22 [dB/m]
38,4KHz: _< 5 [dB/m]
9,6KHz: _< 3 [dB/m]
Insulation resitance: >_ 1 [GW x km] RoHS
Min. bending radius repeated: 20 x outer diam
Min. bending radius single: 10 x outer diam
Norms:
Halogen acid gas: IEC 60754-1, IEC 60754-2
Degree of acidity of gases evolved
during of the combustion: IEC 60754-1, IEC 60754-2
Smoke emission: IEC 61034-1, IEC 61034-2
Toxicity of evolved gad: NES 713
Flame retardant: IEC 60332-1
Ozone resistant: DIN VDE 0472 part 805 B
Digital data communications for measurement and con-
trol – Fieldbus for use in industrial control systems: IEC IEC61158-2
12 NEK Kabel AS Luhrtoppen 2, PB 186, 1470 Lørenskog Tlf. +47 67 91 21 80 Fax. +47 67 91 21 90
Modified: Mar. 12. 2014
NORSK
AKKREDITERING
MSYS 001
NEK KABEL AS
Bruksområde/Application: Construction:
Skjermet BUS-kabel sertifisert for bruk innen skip- og offshore-
Conductor: Stranded bare Cu, 7x0.25
installasjoner. Kabelen er MUD-bestandig. Kabelen er basert på Profi-
bus Marin SHF, med tillegg av en MUD bestandig kappe i h.h.t. NEK
(AWG22), 0.35mm Ø=0.76mm
TS 606. Insulation: Foamed PE, Ø=2.75mm
colour: Green and red
Shielded BUS-cable certified for use in ship and offshore installations. Screen: Al-/polyesterfoil 100% coverage
The cable is MUD-resistant. Based on the DNV approved Profibus and Tinned Cu-braid,>_ 60% optical
Marin, with an additional MUD-res. out jacket acc. to NEK TS 606. coverage
Inner jacket: Black, halogen free SHF1 Ø=8mm
Outer jacket: Black, MUD resistant and UV-resis-
Electrical Specifications:
tant material
Temperature installed: -40 to +90 [°C] Outer diam: Ø=10mm
Working voltage: 100 [V] Weight: 130 kg/km
Test voltage: 1000 [V] dc
Resistant of the inner cond.: <_ 55 [W/km]
Nom. capacitance at 800Hz: 30 [pF/m] Dummy
Characteristic impedance: Stranded Cu
3 - 20MHz: 150±15 [W] Foamed PE
Tinned Cu-braid + Al/polyester foil
38,4 MHz: 185±18,5 [W] Inner jacket, black halogen free
9,6MHz: 250±25 [W] Outer jacket, black MUD resist.
Nom. attenuation:
16MHz: _< 45 [dB/m]
4MHz: _< 22 [dB/m] Prod. no: 1091039
38,4KHz: _< 5 [dB/m]
9,6KHz: _< 3 [dB/m]
[GW x
Insulation resitance: >_ 1 km] RoHS
x outer
Min. bending radius repeated: 20 diam
x outer
Min. bending radius single: 10 diam
Norms:
Halogen acid gas: IEC 60754-1, IEC 60754-2
Degree of acidity of gases evolved
during of the combustion: IEC 60754-1, IEC 60754-2
Smoke emission: IEC 61034-1, IEC 61034-2
Toxicity of evolved gad: NES 713
Flame retardant: IEC 60332-1
Flame resistant: IEC 60332-3-24
Ozone resistant: DIN VDE 0472 part 805 B
Oil and fuel, hydrocabons resist acc: IEC 60502
Water resistant acc.: IEC 60502, ASTM G 154,
ASTM D 4587, EN ISO 11507
UV resistant acc.: ASTM D 2565-92A
Digital data communications for measurement and con-
trol – Fieldbus for use in industrial control systems: IEC IEC61158-2
NEK Kabel AS Luhrtoppen 2, PB 186, 1470 Lørenskog Tlf. +47 67 91 21 80 Fax. +47 67 91 21 90 13
Modified: Mar. 12. 2014
NORSK
AKKREDITERING
MSYS 001
NEK KABEL AS
RoHS
Frequency Attenuation
[MHz] [dB/100m]
5 1,2
50 4,3
100 6,4
300 11,5
500 15,3
800 20,4
1000 23,2
1500 30,4
2150 38,9
2500 42,7
3000 48,9
14 NEK Kabel AS Luhrtoppen 2, PB 186, 1470 Lørenskog Tlf. +47 67 91 21 80 Fax. +47 67 91 21 90
Modified: Mar. 12. 2014
NORSK
AKKREDITERING
MSYS 001
NEK KABEL AS
Norms:
Flame retardant acc.to: IEC 60332-1 Prod. no: 17 alt.1 SHF1
Fire restistant acc. to: IEC 60332-3 Prod. no: 1092438 alt.2 MUD
Smoke acc. to: IEC 61034-2
Corrosive gases acc. to: IEC 60754-1, IEC 60754-2
Frequency Attenuation
[MHz] [dB/100m]
5 3,0
10 4,0 Structural return loss dB
50 9,4
100 13,0 MHz
200 18,6 30 - 300 >28
300 23,3 300 - 600 >27
500 31,2 600 - 1000 >25
600 34,7 1000 - 2000 >20
800 41,0 2000 - 3000 >18
1000 46,8
1350 56,6
1500 60,6 Screening efectiveness dB
1750 66,9
2150 76,9 MHz mW/m
2250 78,4
2500 83,5 100 - 900 >90
2750 86,5 900 - 2000 >80
3000 89,5 2000 - 3000 >70
NEK Kabel AS Luhrtoppen 2, PB 186, 1470 Lørenskog Tlf. +47 67 91 21 80 Fax. +47 67 91 21 90 15
Modified: Mar. 12. 2014
NORSK
AKKREDITERING
MSYS 001
NEK KABEL AS
Frequency Attenuation
[MHz] [dB/100m]
5 3,0
Structural return loss dB
10 4,0
50 9,4
100 13,0 MHz
200 18,6 30 - 300 >28
300 23,3 300 - 600 >27
500 31,2 600 - 1000 >25
600 34,7 1000 - 2000 >20
800 41,0 2000 - 3000 >18
1000 46,8
1350 56,6
1500 60,6 Screening efectiveness dB
1750 66,9
2150 76,9 MHz mW/m
2250 78,4
2500 83,5 100 - 900 >90
2750 86,5 900 - 2000 >80
3000 89,5 2000 - 3000 >70
16 NEK Kabel AS Luhrtoppen 2, PB 186, 1470 Lørenskog Tlf. +47 67 91 21 80 Fax. +47 67 91 21 90
Modified: Mar. 12. 2014
NORSK
AKKREDITERING
MSYS 001
NEK KABEL AS
Specifications:
Temperature range SHF1: -30 to +70 [°C] Outer jacket alt. 2: Black, LSZH SHF 1 + Black MUD-
Temperature range MUD: -40 to +70 [°C] resistant acc. to NEK TS 606
Ø=12,8±0,18mm
Inner conductor resistance: 6 [W/km]
Weight app. 182kg/km
Outer conductor resistance: 4 [W/km]
Tension sheath spark testing: 5,5 [kV]
Outer Jacket SHF1 Outer Jacket SHF1+MUD
Impedance: 50±2 [W]
Capacitance: 100 [pF/km] Jacket SHF1
Attenuation: see table Screen
Velocity ratio: 0,66
Dielectric
Min. bending radius fixed: 5 x outer diam
Min. bending radius flexible: 10 outer diam. Conductor
Norms:
Flame retardant acc.to: IEC 60332-1
Fire restistant acc. to: IEC 60332-3
Smoke acc. to: IEC 61034-2
Corrosive gases acc. to: IEC 60754-1, IEC 60754-2
MUD resistant acc.: NEK TS 606 Prod. no: 1092440 alt.1 SHF1
Manufactured in compliance with MIL17/074 standards Prod. no: 1092442 alt.1 MUD
NEK Kabel AS Luhrtoppen 2, PB 186, 1470 Lørenskog Tlf. +47 67 91 21 80 Fax. +47 67 91 21 90 17
Modified: Mar. 12. 2014
NORSK
AKKREDITERING
MSYS 001
NEK KABEL AS
MUD resistant acc.: NEK TS 606 Prod. no: 1092441 alt.1 SHF1
Manufactured in compliance with MIL17/074 standards Prod. no: 1092443 alt.2 MUD
18 NEK Kabel AS Luhrtoppen 2, PB 186, 1470 Lørenskog Tlf. +47 67 91 21 80 Fax. +47 67 91 21 90
Modified: Mar. 12. 2014
NORSK
AKKREDITERING
MSYS 001
NEK KABEL AS
RoHS
NEK Kabel AS Luhrtoppen 2, PB 186, 1470 Lørenskog Tlf. +47 67 91 21 80 Fax. +47 67 91 21 90 19
Modified: Mar. 12. 2014
NORSK
AKKREDITERING
MSYS 001
NEK KABEL AS
20 NEK Kabel AS Luhrtoppen 2, PB 186, 1470 Lørenskog Tlf. +47 67 91 21 80 Fax. +47 67 91 21 90
Modified: Mar. 12. 2014
NORSK
AKKREDITERING
MSYS 001
NEK KABEL AS
MUD-resistant version is according NEK TS 606 Prod. no.: 1092452 alt.1 SHF1
Manufactured in compliance with MIL C-17-F standards
Prod. no.: 1092454 alt.2 MUD
Approvals: DNV- and ABS-certified
RoHS
NEK Kabel AS Luhrtoppen 2, PB 186, 1470 Lørenskog Tlf. +47 67 91 21 80 Fax. +47 67 91 21 90 21
Modified: Mar. 12. 2014
NORSK
AKKREDITERING
MSYS 001
NEK KABEL AS
MUD-resistant version is according NEK TS 606 Prod. no.: 1092453 alt.1 SHF1
Manufactured in compliance with MIL C-17-F standards Prod. no.: 1092455 alt.2 MUD
Approvals: DNV- and ABS-certified
RoHS
22 NEK Kabel AS Luhrtoppen 2, PB 186, 1470 Lørenskog Tlf. +47 67 91 21 80 Fax. +47 67 91 21 90
Modified: Mar. 12. 2014
NORSK
AKKREDITERING
MSYS 001
NEK KABEL AS
RG59 Flex
Flexible coaxial cable
PVC or LSZH outer jacket
75W
Bruksområde/Application: Construction:
Fleksibel koaksialkabel for data- og videooverføring. Med PVC-kappe Conductor: Cu- wire, 7x0,25mm
eller flammehemmet ytre kappe for skip og offshore eller offentlige Dielectric: PEE Ø=3,7mm
bygg der det er påkrevet med halogenfri kabel.
Screen: Plain Cu-braid, 95% optical coverage
Outer Jacket: Black, PVC or LSZH compound
Flexible coaxial cable for data and video transmission. With PVC jacket
or flame retardant for ship and offshore or in public areas where halogen Outer diam.: 6,15mm
free compound is required. Weight: App. 53kg/km
RoHS
Frequency Attenuation
[MHz] [dB/100m]
50 7,0
100 10,1
200 14,0
400 20,2
800 30,3
1000 34,8
NEK Kabel AS Luhrtoppen 2, PB 186, 1470 Lørenskog Tlf. +47 67 91 21 80 Fax. +47 67 91 21 90 23
Modified: Mar. 12. 2014
NORSK
AKKREDITERING
MSYS 001
NEK KABEL AS
RoHS
24 NEK Kabel AS Luhrtoppen 2, PB 186, 1470 Lørenskog Tlf. +47 67 91 21 80 Fax. +47 67 91 21 90
Modified: Mar. 12. 2014
NORSK
AKKREDITERING
MSYS 001
NEK KABEL AS
MUD-resistant according to NEK TS 606 Tips Connector: BNC crimp LSD 53938C
Manufactured in compliance with MIL 17/06 standards
Prod. no.: 1092449 alt.1 SHF1
Approval: DNV- and ABS-certified
Prod. no.: 1092451 alt.2 MUD
Frequency Attenuation
[MHz] [dB/100m] RoHS
5 1,8 Structural return loss dB
10 2,3
50 5,7 MHz
100 8,1
200 11,7 30 - 300 >28
300 14,5 300 - 600 >24
500 19,0 600 - 1000 >22
600 21,0 1000 - 2000 >18
800 24,6 2000 - 3000 >15
1000 27,7
1350 32,6
Screening efectiveness dB
1500 34,6
1750 38,7
MHz
2150 44,1
2250 44,5 100 - 900 >90
2500 46,6 900 - 2000 >80
2750 49,3 2000 - 3000 >70
3000 53,4
NEK Kabel AS Luhrtoppen 2, PB 186, 1470 Lørenskog Tlf. +47 67 91 21 80 Fax. +47 67 91 21 90 25
Modified: Mar. 12. 2014
NORSK
AKKREDITERING
MSYS 001
NEK KABEL AS
RoHS
26 NEK Kabel AS Luhrtoppen 2, PB 186, 1470 Lørenskog Tlf. +47 67 91 21 80 Fax. +47 67 91 21 90
Modified: Mar. 12. 2014
NORSK
AKKREDITERING
MSYS 001
NEK KABEL AS
NEK Kabel AS Luhrtoppen 2, PB 186, 1470 Lørenskog Tlf. +47 67 91 21 80 Fax. +47 67 91 21 90 27
Modified: Mar. 12. 2014
NORSK
AKKREDITERING
MSYS 001
NEK KABEL AS
RG11 MUD-NAVY
Coaxial cable for offshore and ship inst.
MUD-resistant and LSZH
75W 1.65/7.2
Bruksområde/Application: Construction:
MUD bestandig 75 Ohm koakskabel for digital overføring, designet for Conductor: Bare Cu, Ø=1.65mm + carbon black PE
tøffe utendørs omgivelser. Kabelen egner seg for onshore, offshore,
Insulation: Foamed PE +carbon black PE Ø 7,2
på skip og ellers der den kan være utsatt for etsende kjemikalier og
oljer. Kappen er halogenfri og flammehemmet.
Screen: Triplex Al-foil, + tinned Cu-braid,
coverage 77%
MUD resistant 75 Ohm coaxial cable for digital transmission, designed Jacket: Black, SHF2 (LSZH) MUD resistant
for outdoor though sensitive environments. The cable is suitable for in- compound acc.to NEK TS 606
stallation in harsh environments, onshore, offshore, ship and wherever Outer diam: 10.80mm
there is presence of oils and petrochemical muds. Jacket is LSZH. Weight: 130 kg/km
Marking: NEK Kabel - RG11 MUD Resistant
SHF2 NAVY - ww/yy - PL-BLC lot no +
Electrical Specifications: meter
Temperature range SHF1: -30 to +70 [°C] Outer jacket LSZH MUD
Temperature range MUD: -40 to +70 [°C] Screen Al-foil + tinned Cu-braid
Dielectric
Inner cond.resistance: 8,2 [W/km] Carbon black PE
Outer cond.resistance: 5,0 [W/km] Conductor
Norms: RoHS
Standard: IEC 60092-359
MUD-Compound acc.: NEK TS 606
Connectors and Tools:
654005: BNC male to female
Tips
6502411: compression F-plug
6502417: Compression Tong
6502418: Assembly tool for F-plug
570-05120: Unjacketing tool for RG 11
Frequency Attenuation
[MHz] [dB/100m]
50 2,8
230 6,2
470 8,9
860 12,3
1000 13,5
1350 16,3
1500 17,4
1750 18,8
28 NEK Kabel AS Luhrtoppen 2, PB 186, 1470 Lørenskog Tlf. +47 67 91 21 80 Fax. +47 67 91 21 90
Modified: Mar. 12. 2014
NORSK
AKKREDITERING
MSYS 001
NEK KABEL AS
SAT 22
ITV-Cable LSZH
UV-resistant
RG 59 B/U + 2 x 0.75mm²
Bruksområde/Application: Construction:
ITV kabel for bruk innen internovervåking. Kabelen er halogenfri og Cable: RG 59 B/U and Multicable with
flammehemmet, samt UV-bestandig. SAT 22 er for bruk innen skip, off- common jacket
shore, eller offentlige bygg der det stilles strenge krav til brannsikkerhet. RG 59B/U:
Ikke for nettspenning!
Inner conductor: Cu-plated steel, 0,58mm
Composite cable for ITV and CCTV, low smoke and halogen free. SAT
Dielectric: PE, Ø=3,7mm
22 is for use in ship and offshore or other places where high norms for Screen: Cu-braid, >90% optical cover
firesafety is required. The cable is UV-resistant. Jacket: LSOH compound
Not for power supply!
Multicable 2x0.75mm²:
Conductor: Stranded Cu, 0.75mm²
Electrical Specifications: Jacket: PE
Colour: Red and black
Temperature installed: -30 to + 80 [°C]
Temperature @ installation: 0 to +50 [°C]
Outer jacket: Black UV-resistant and LSZH
RG 59: compound
Outer diam.: 10mm
DC-resistant centre conductor: 155 [W/km]
DC-resistant outer conductor: 10,1 [W/km] Stranded Cu
Insulation, PE
Impedance: 75±3 [W] Filler compound
Capacitance @800Hz: 67 [pF/m] Dielectric
Attenuation: see table Cu-plated steel
Screen Cu-braid
Velocity factor: 0,66 Jacket LSZH compound
Outer jacket
Multicable 2x0.75mm²:
Rated voltage: 250 [V]-max.
Test voltage: 1200 [V]
Loop resistant: 26 [W/km]
Prod. no: 1092421
Norms:
Fire: IEC 332-1
Halogen: IEC 754
Smoke: IEC 1034
RoHS
Attenuation
Frequency
Max.(acc.EN)
[MHz]
[dB/100m]
10 3,6
50 7,7
100 11,0
200 15,9
400 23,1
800 34,2
1000 38,9
NEK Kabel AS Luhrtoppen 2, PB 186, 1470 Lørenskog Tlf. +47 67 91 21 80 Fax. +47 67 91 21 90 29
Modified: Mar. 12. 2014
NORSK
AKKREDITERING
MSYS 001
NEK KABEL AS
AICI
Indoor and outdoor
Armoured industrial cable, LSZH
Steel wire braiding, tight buffer
Bruksområde/Application: Construction:
Optisk kabel for industri-miljøer, egnet for både innendørs og utendørs
bruk. Vedvarende nedsenkning i vann er ikke anbefalt. Ytre kappe Outer Jacket
er laget av UV-og værbestandig materiale og kan utsettes i kortere
Steel wire braiding
perioder for væsker som diesel og mineraloljer (iht. IEC 60811-2-1).
Inner Jacket
Kabelen er forsterket med flettet stålwire mellom inner- og ytre kappe.
Glass yarn
Strekkelementer av glas garn rundt kabelkjernen gjør det enklere for
Water swelling material
installasjon over lengre avstander. Fast kledning på 0,9mm gir en Outer Jacket
rask og holdbar spleising og enkel montering av kontakter. Hver fiber
er fargekodet for enkel identifisering. Merking på ytterkappen viser
fiber- og kabeltype. Kabelen er DNV sertifisert.
Optical cable for industri environments. The cable is suitable for both
indoor and outdoor use. Continuos submergence in water is not Secondary Outer diam. Weight Tensile str. *
recommended. Outer jacket made of UV- and weather resistant ma- No. of fibres: coating (inst./oper.)
terialand may be exposed for shorter periods to fluids such as diesel [mm] [mm] [kg/km] [N]
and mineral oils (acc. to IEC 60811-2-1). The cable is reinforced with a 4 0.9 8,2 90 700/250
steel wire braiding between the two jackets. Strength elements of glas
yarn around the cable core allow easy installation of long lengths. The 8 0.9 9,4 125 800/350
0,9mm tight buffer is easy to strip allowing fast and reliable splicing and 12 0.9 10,3 145 1200/500
connector mounting. Each fibre is colour coded for easy identification. 24 0.9 12,0 185 1700/750
Outer jacket is marked to show fibre type and cable type. The cable * acc. IEC 60794-1-2E1
is DNV approved.
Specifications:
Temperature installed: -40 to +70 [°C]
Temperature @ installation: -10 to +70 [°C]
Crush, acc IEC 60794-1-2E3: 2000 [N/10cm]
Impact, acc IEC 60794-1-2E4: 1 impacts, 25J
Torsion, acc IEC 60794-1-2E7: ± 1 turns/1m
Water tightness acc. IEC 60794-1-2F5B: < 3m/24hours
30 NEK Kabel AS Luhrtoppen 2, PB 186, 1470 Lørenskog Tlf. +47 67 91 21 80 Fax. +47 67 91 21 90
Modified: Mar. 12. 2014
NORSK
AKKREDITERING
MSYS 001
NEK KABEL AS
* Over Filled Launch methode (OFL). Modal Bandwith in accordance IEC 60793-1-41
** According IEC 60794-3, Ed.3 (Q=0,01%
NEK Kabel AS Luhrtoppen 2, PB 186, 1470 Lørenskog Tlf. +47 67 91 21 80 Fax. +47 67 91 21 90 31
Modified: Mar. 12. 2014
NORSK
AKKREDITERING
MSYS 001
NEK KABEL AS
AIAI
Tight reinforced with double sheath
Non metallic, double dielectric
12 or 24 fibre
Bruksområde/Application: Construction:
Optisk kabel for industri, skip og offshore miljøer, egnet for både innen- Optical core: Tight buffered, nom. Ø=0,9mm
dørs og utendørs bruk. Kabelen har dobbel kappe, med glassgarn- Colour of fibre: 1 - blue 13 - blue + black ring
forsterkning mellom, samt vannsikker glassgarn mellom innerkappe
2 - orange 14 - orange + black ring
og fibre og dermed vannsikker. Kabelen er fri for metall, noe som gjør
3 - green 15 - green + black ring
den anvendelig for installasjon sammen med Cu-kabel.
4 - brown 16 - brown + black ring
Optical cable for industry, ship and offshore environments. The cable is 5 - grey 17 - grey + black ring
suitable for both indoor and outdoor use. Double jacket with glassyarn 6 - white 18 - white + black ring
in between, makes the cable mecanically strong without use of metal, 7 - red 19 - red + black ring
and therefore suitable for installation together with Cu-cable. The 8 - black 20 - yellow + black ring
waterblocking glass yarns between inner sheath and the fibres makes 9 - yellow 21 - violet + black ring
the cable waterproof. 10 - violet 22 - pink + black ring
11 - pink 23 - turqouise + black ring
Specifications: 12 - turqouise 24 - white + double
black ring
Temperature installed: -30 to +70 [°C] Protection/dielectric: Waterblocking glass yarns
Temperature @ installation: -10 to +50 [°C] Inner sheath: Orange LSZH compound,
Temperature storage: -40 to +70 [°C] thickness 1,2mm
Tensile perf.: (IEC60794-1-2-E1) 2000 [N] Ø=6,7mm 12 fibre
Crush: (IEC60794-1-2-E3) 2000 [N] Ø=8,5mm 24 fibre
Impact: (IEC60794-1-2-E4) 20 [J] Protection/dielectric: Glass yarns
Water penetration: (IEC60794-1-2-F5) No water leakage Outer Sheath: Orange LSZH, UV-resistant compound,
(limited to inner sheath) thickness 1,3mm
Min. bending radius static: 10 x outer diam
Ø=10,3mm 12 fibre
Min. bending radius static: 15 x outer diam
Ø=12,1mm 24 fibre
12 fibre: 115 kg/km
Norm: Weight:
24 fibre: 160 kg/km
- Halogen acid emission <_ 0,3% when tested acc. to
IEC 60754-1/2
- Degree of acidity of gases evolved during of the combus-
tion (pH value >_ 4,3 and Conductivity <_ 10mS/mm) when Waterblocking glassyarn
tested acc. to IEC 60754-1/2 Fibre
- Smoke emission (Transmittance) >_ 60% when tested acc. Inner sheath
to IEC 61034-1 and IEC 61034-2 Glassyarn
- Fire propagation complying with IEC 60332-3-24 and Outer sheath
IEC 60332-1-2
32 NEK Kabel AS Luhrtoppen 2, PB 186, 1470 Lørenskog Tlf. +47 67 91 21 80 Fax. +47 67 91 21 90
Modified: Mar. 12. 2014
NORSK
AKKREDITERING
MSYS 001
NEK KABEL AS
QFCI-I/O/RM-JM
Indoor and outdoor, loose tube
LSZH
4, 8 , 12, 24 or 48 fibres
Bruksområde/Application: Construction:
Funksjonssikker fiberkabel for innen- og utendørs bruk der kommu-
nikasjon og signaler er viktig å opprettholdes ved brann. Kabelen er No. of fibre:
konstruert for å fungere under brann i minst 3 timer og varme opp til 2 1-Red (with 2-OF) 4-Filler
1000°C. Ytterkappen er UV- og værbestandig, og kan kortvarig utsettes 2-Filler 5-Filler
for væsker som olje, bensin, glycol, etanol, whitesprite og hydraulik- 3-Filler 6-Filler
kolje. Kabelen har flettet stålarmering, fiberene ligger i fettfylte rør og 4 1-Red (with 2-OF) 4-Filler
har fargekode for enkel identifisering. 2-Green (with 2-OF) 5-Filler
3-Filler 6-Filler
Optical cable for indoor and outdoor use in vital communication 8 1-Red (with 4-OF) 4-Filler
and emergency systems that need to be operational during fire. 2-Green (with 4-OF) 5-Filler
The cable is designed to ensure operation for more than 3 hours in 3-Filler 6-Filler
fires up to 1000ºC. The cable is halogen free and flame retardant to 12 1-Red (with 4-OF) 4-Filler
protect against secondary damage to electronic equipment during 2-Green (with 4-OF) 5-Filler
and after fire. Outer sheath is made from black UV-stabilized and 3-Natural (with 4-OF) 6-Filler
weather resistant material and may be exposed for shorter periods 24 1-Red (with 6-OF) 4-Nat. (with 6-OF)
to fluids such as diesel, petrol, glycol, etanol, white spirite and ASTM 2-Green (with 6-OF) 5-Filler
oil 2. The resistance to these fluids is according to DOD-STD-1678, 3-Natural (with 6-OF) 6-Filler
method 8030.The cable is reinforced with a steel wire braiding. The 48 1-Red (with 12-OF) 4-Nat. (with 12-OF)
fibres are protected in jelly filled loose tubes stranded around a 2-Green (with 12-OF) 5-Filler
central strength member to ensure optimum performance and long 3-Natural (with 12-OF) 6-Filler
life. Each fibre and loose tube is colour coded for easy identification Loose tube diam.: 2.2mm
during splicing and termination. The outer sheath is marked to show 1-white 4-green 7-brown 10-turquise
fibre type and cable type. Colour of fibre: 2-red 5-blue 8-black 11-orange
3-yellow 6-grey 9-violet 12-pink
Outer diam: 13.5mm
Weight: 260 kg/km
Specifications:
Temperature installed: -40 to +70 [°C] Optical fibre
Temperature @ installation: -10 to +60 [°C] Loose tube
Steel strength element
Tensile installed (IEC 60794-1-2E1): 500 [N] Mica tape
Tensile @ installation: 1500 [N] Inner sheath SHF1
Crush (IEC 60794-1-2E3): 3000 [N/10cm] Steel wire braiding
Impact (IEC 60794-1-2E4): 30 [J] Filler, dummies
Torsion (IEC 60794-1-2E7): ±1 [turn/m] Black or red outer sheath,
Min.bending diam(IEC 60794-1-2E3): 250 [mm] UV-resistant SHF1
Norms:
Chemical resistance: IEC 60811-2-1 (Mineral oils)
Fire and smoke: IEC 60331-25, IEC 60332-3-24, IEC
60794-1-1, IEC 60754-1,
IEC 61034-1, IEC 61034-2
RoHS
Approval: DNV CERTIFICATE NO. E-11775
NEK Kabel AS Luhrtoppen 2, PB 186, 1470 Lørenskog Tlf. +47 67 91 21 80 Fax. +47 67 91 21 90 33
Modified: Mar. 12. 2014
NORSK
AKKREDITERING
MSYS 001
NEK KABEL AS
34 NEK Kabel AS Luhrtoppen 2, PB 186, 1470 Lørenskog Tlf. +47 67 91 21 80 Fax. +47 67 91 21 90
Modified: Mar. 12. 2014
NORSK
AKKREDITERING
MSYS 001
NEK KABEL AS
QFCI -MUD
Intrinsic safety
Indoor and outdoor, loose tube LSZH
4, 8 , 12, 24 or 48 fibres
Bruksområde/Application: Construction:
Funksjonssikker fiberkabel med MUD-bestandig ytterkappe for in- Loose tube diam.: 2.2 mm, Mica tape on each loose tube
nen- og utendørs bruk der kommunikasjon og signaler er viktig å colour of fibres: 1-white 4-green 7-brown 10-turquoise
opprettholdes ved brann. Kabelen er konstruert for å fungere under 2-red 5-blue 8-black 11-orange
brann i minst 3 timer og varme opp til 1000°C. Ytterkappe1 er UV- og 3-yellow 6-grey 9-violet 12-pink
værbestandig, og kan kortvarig utsettes for væsker som olje, ben- No. of fibre:
sin, glycol, etanol, whitesprite og hydraulikkolje. Kabelen har flettet 2 1-Red (with 2-OF) 4-Filler
stålarmering, fiberene ligger i fettfylte rør og har fargekode for enkel 2-Filler 5-Filler
identifisering. Kabelen har en ekstra MUD-bestandig ytre kappe for å 3-Filler 6-Filler
gjøre den ekstra motstandsdyktig mot oljer og kjemikalier. Kabelen er 4 1-Red (with 2-OF) 4-Filler
basert på QFCI med DNV-godkjenning for marine- og offshoreinstal- 2-Green (with 2-OF) 5-Filler
lasjoner. Kabelen er MUD bestandig i h.h.t NEK TS 606. 3-Filler 6-Filler
8 1-Red (with 4-OF) 4-Filler
Optical cable for indoor and outdoor use in vital communication 2-Green (with 4-OF) 5-Filler
and emergency systems that need to be operational during fire. 3-Filler 6-Filler
The cable is designed to ensure operation for more than 3 hours in 12 1-Red (with 4-OF) 4-Filler
fires up to 1000ºC. The cable is halogen free and flame retardant to 2-Green (with 4-OF) 5-Filler
protect against secondary damage to electronic equipment during 3-Natural (with 4-OF) 6-Filler
and after fire. Outer sheath is made from black UV-stabilized and 24 1-Red (with 6-OF) 4-Nat. (with 6-OF)
weather resistant material and may be exposed for shorter periods 2-Green (with 6-OF) 5-Filler
to fluids such as diesel, petrol, glycol, etanol, white spirite and ASTM 3-Natural (with 6-OF) 6-Filler
oil 2. The resistance to these fluids is according to DOD-STD-1678, 48 1-Red (with 12-OF) 4-Nat. (with 12-OF)
method 8030.The cable is reinforced with a steel wire braiding. The 2-Green (with 12-OF) 5-Filler
fibres are protected in jelly filled loose tubes stranded around a 3-Natural (with 12-OF) 6-Filler
central strength member to ensure optimum performance and long Assembling: Galvanized steel rope + n coloured
life. Each fibre and loose tube is colour coded for easy identification loose stranded + n filler + syntetic tape
during splicing and termination. The outer sheath is marked to show Inner jacket: Black LSZH, Ø=10,1mm
fibre type and cable type. The cable is based on QFCI with DNV-
Armour: Galvanized steel wire braid >_ 85%
approval for marine and offshore installations. The cable is MUD
resistant according to NEK TS 606.
Intermediate sheath: Black LSZH, Ø=13,5mm
Outer jacket: Black LSZH UV- and MUD resist. SHF2
Outer diam: 16,5 mm
Weight: 350 kg/km
Specifications: Optical fibre
Temperature installed: -40 to +70 [°C] Loose tube
Temperature @ installation: -10 to +60 [°C] Steel strength element
Mica tape
Tensile installed (IEC 60794-1-2E1): 500 [N] Inner sheath SHF1
Tensile @ installation: 1500 [N] Steel wire braiding
Crush: 3000 [N/10cm] Filler, dummies
Impact: 5 [J] Outer sheath 1
Torsion: ±1 [turn/m]
Min.bending diam. fixed: 15 x outer diam Outer sheath 2 MUD
Min.bending diam. flexible: 20 x outer diam
Nubers of Numbers
Norms: Numbers of Weight
fibre of tubes Prod.no:
Fire and smoke: IEC 60331-25, BP-236, IEC 61034 fibre [kg/km]
pr. tube + fillers
IEC 60332-3 catA and C,
IEC 60754-1, IEC 60754/2 4 - 62,5/125 2 2+4 325 1091114
MUD resistant acc. to: NEK TS 606 8 - 62,5/125 4 2+4 325 1091115
12 - 62,5/125 4 3+3 325 1091116
Approval: DNV CERTIFICATE NO. E-11775 24 - 62,5/125 6 4+2 325 1091117
48 - 62,5/125 12 4+2 325 1091126
NEK Kabel AS Luhrtoppen 2, PB 186, 1470 Lørenskog Tlf. +47 67 91 21 80 Fax. +47 67 91 21 90 35
Modified: Mar. 12. 2014
NORSK
AKKREDITERING
MSYS 001
NEK KABEL AS
Notes:
36 NEK Kabel AS Luhrtoppen 2, PB 186, 1470 Lørenskog Tlf. +47 67 91 21 80 Fax. +47 61 91 21 90