You are on page 1of 5

This image is for illustration purposes only.

J-350 KVA Genset


Output Ratings Ratings and Performance Data

Voltage, Frequency Prime Standby Engine Make & Model: Perkins® 2206A-E13TAG2

400V, 50 Hz 350.0 kVA / 280.0 kW 400.0 kVA / 320.0 kW Alternator manufactured for
Leroy Somer
JIMCO by:
- / - - / -
Alternator Model: LSA47.2 VS2
Ratings at 0.8 power factor.
Control Panel: Deep Sea-6020
Please refer to the output ratings technical data section for specific
generator set outputs per voltage. Base Frame: Heavy Duty Fabricated Steel
Circuit Breaker Type: 3 Pole MCCB
Frequency: 50 Hz 60 Hz
Prime Rating
These ratings are applicable for supplying continuous electrical power Engine Speed: RPM 1500 -
(at variable load) in lieu of commercially purchased power. There is no
limitation to the annual hours of operation and this model can supply 10% Fuel Tank Capacity: 525(138.69)
litres (US gal)
overload power for 1 hour in 12 hours.
Fuel Consumption: l/hr (US gal/hr)
Standby Rating
(100% Load) - Prime 71 (18.7) -
These ratings are applicable for supplying continuous electrical power (at
variable load) in the event of a utility power failure. No overload is
- Standby 80 (21.1) -
permitted on these ratings. The alternator on this model is peak
continuous rated (as defined in ISO 9001).

Standard Reference Conditions


Available Options
Note: Standard reference conditions 25°C (77°F) Air Inlet Temp, 100m
(328 ft) A.S.L. 30% relative humidity.
JIMCO offer a range of optional features to tailor our generating
Fuel consumption data at full load with diesel fuel with specific gravity of sets to meet your power needs. Options include:
0.85 and conforming to BS2869: 1998, Class A2.
A wide range of Sound Attenuated Enclosures
A variety of generating set control and synchronising panels
Additional alarms and shutdowns
A selection of exhaust silencer noise levels
For further information on all of the standard and optional features
accompanying this product please visit: www.jubaili.com

Dimensions and Weights

Length (L) Width (W) Height (H) Dry Wet


mm (in) mm (in) mm (in) kg (lb) kg (lb)

3200(125.98) 1110(43.7) 2070(81.4) 3281(7233.3) 3366(7420.7)

Dry = With Lube Oil Wet = With Lube Oil and Coolant
Powered by: Ratings in accordance with ISO 9001
Generating set pictured may include optional accessories.
Engine Technical Data Air Systems 50 Hz 60 Hz

No. of Cylinders / Alignment: 6 / In Line Air Filter Type: Non Canister


Cycle: 4 Stroke Combustion Air Flow: m³/min (cfm)

Bore / Stroke: mm (in) 130.0 (5.1)/157.0 (6.2) - Prime 21.3 (752) -


Turbocharged Air To Air - Standby 23.6 (833) -
Induction:
Charge Cooled
Max. Combustion Air Intake
Cooling Method: Restriction: kPa (in H2O) 6.4 (25.7) -
Water
Governing Type: Electronic
Governing Class: ISO 9001
Compression Ratio: 16.3:1
Cooling System 50 Hz 60 Hz
Displacement: l (cu. in) 12.5 (762.8)
Cooling System Capacity: l (US gal) 51.4 (13.5) -
Moment of Inertia: kg m² (lb/in²) 2.77 (9465)
Water Pump Type: Centrifugal
Engine Electrical System:
Heat Rejected to Water & Lube Oil:
- Voltage / Ground 24/Negative
kW (Btu/min) - Prime 113.5 (6455) -
- Battery Charger Amps 70
- Standby 128.5 (7308) -
Weight: kg (lb) - Dry 1301 (2868) Heat Radiation to Room: Heat radiated from engine and alternator
- Wet 1351 (2978)
kW (Btu/min) - Prime 43.9 (2497)
- Standby 56.3 (3202)

Radiator Fan Load: kW (hp) 14.0 (18.8) -

Performance 50 Hz 60 Hz Radiator Cooling Airflow: m³/min (cfm) 564 (19917.47) -


External Restriction to
Engine Speed: rpm 1500 - 125 (0.5) -
Cooling Airflow: Pa (in H2O)
Gross Engine Power: kW (hp)
Designed to operate in ambient conditions up to 50°C (122°F).
- Prime 324.2 (435.0) -
- Standby 367.4 (493.0) -
BMEP: kPa (psi)

- Prime 2075.0 (300.9) - Lubrication System

- Standby 2350.0 (340.9) - Oil Filter Type: Eco, Full Flow


Total Oil Capacity: l (US gal) 40.0 (10.6)
Oil Pan: l (US gal) 38.0 (10.0)
Oil Type: Shell

Fuel System Oil Cooling Method: Water

Fuel Filter Type: Replaceable Element


Recommended Fuel: Class A2 Diesel or BSEN590
Fuel Consumption: l/hr (US gal/hr) Exhaust System 50 Hz 60 Hz
110% 100% 75% 50% Maximum Allowable Back Pressure: 10.0 (3.0) -
kPa (in Hg)
Prime Load Load Load Load
Exhaust Gas Flow: m³/min (cfm)
50 Hz 79.0 (20.9) 71 (18.7) 53.0 (14.0) 36.2 (9.6)
- Prime 56.6 (1999) -
60 Hz - - - -
- Standby 64.8 (2288) -
Exhaust Gas Temperature: °C (°F)

- Prime 630 (1166) -


100% 75% 50%
- Standby 630 (1166) -
50 Hz 80.0 (21.1) 60.1 (15.9) 41.0 (10.8)
60 Hz - - -

(Based on diesel fuel with a specific gravity of 0.85 and conforming to BS2869,
Class A2)
Alternator Physical Data Alternator Operating Data

Manufactured for JIMCO by: Leroy Somer Overspeed: rpm 2250


Model: LSA 47.2 VS2 Voltage Reguation: (Steady state) +/- 0.5%
No. of Bearings: 1 Wave Form NEMA = TIF: < 50
Insulation Class: H Wave Form IEC = THF: <1.5%
Winding Pitch Code: 2/3 - 6 Total Harmonic content LL/LN: <2%
Suppression is in line with European
Wires: 12 Radio Interference:
Standard EN61000-6
Ingress Protection Rating: IP23 Radiant Heat: kW (Btu/min)

Excitation System: SHUNT - 50 Hz 24.1 (1371)


AVR Model: R250 - 60 Hz -

Alternator
50 Hz 60 Hz
Performance Data:

Data Item 400/230V 480/220V

Motor Starting
722 994
Capability*

Xd 3.360 3.490
X’d 0.193 0.201
X’’d 0.135 0.141

Reactances shown are applicable to prime ratings.


*Based on 30% voltage dip at 0.6 power factor and SHUNT excitation.
**With optional permanent magnet generator or AREP excitation.

Output Ratings Technical Data 50 Hz Output Ratings Technical Data 60 Hz


Voltage Prime: Standby: Voltage Prime: Standby:
kVA kW kVA kW kVA kW kVA kW
415/240V 350.0 280.0 400.0 320.0

400/230V 350.0 280.0 400.0 320.0

380/220V 350.0 280.0 400.0 320.0


General Information
Alternator Physical Data Alternator Operating Data

Documentation

A full set of operation and maintenance manuals and circuit wiring diagrams are available.

Generating Set Standards

The equipment meets the following standards: ISO 9001.


A.R Jubaili & Co. is a fully accredited ISO 9001
company.

Warranty

All prime equipment carries a one year manufacturer's warranty. Standby equipment, limited to 500 running hours per year, has a two year manufacturer's

warranty. For details on warranty cover please visit our website: jubaili.com.

Dealer contact details:

Showroom
Airport Bridge, Plaza Center
Tel/Fax +961-1 840209 /224 /228
Mobile: +961-3-758 392

E-mail info@jubaili.com