You are on page 1of 3

Doosan PDS-600

INTRODUCTION
The power generation system, providing optimum performance, and reliability, for stationary standby, prime power and continuous
duty applications. All generator sets are factory build, and production tested.

50 Hz, 1500 RPM, 3-PHASE, PF 0.8, 400/230V


Standby Rating (ESP) Prime Rating (PRP)
Gensets Model Standby Amper
kW kVA kW kVA
PDS-600 480 600 460 550

Standby Rating (ESP) Applicable for supplying power to varying electrical load for the duration of power interruption of a
reliable utility source. ESP is in accordance with ISO 8528. Overload is not allowed.
Prime Rating (PRP) Applicable for supplying power to varying electrical load for unlimited hours. PRP is in accordance with ISO
8528. 10 % overload capability is available for a period of 1 hour within 12-hour period of operation, in accordance with ISO
3046.

GENERAL SPECIFICATIONS
Genset Model PDS-600
Frequency, Hz 50
Fuel Type Diesel
Engine Model DP180LA
Alternator Model HCI544E
Control Panel Model ComAp
Governor Regulation Class G2 Class ( ISO 8528 )

ENGINE SPECIFICATIONS
Ratings Prime Standby
Engine Manufacturer Doosan Infracore
Engine Model DP180LA
Engine Type 4- Cycle, TurboCharged & Intercooled (air to air)
No. of Cylinders 10-Cylinder
Bore, mm 128
Stroke, mm 142
Displacement, L 18.273
Gross Engine Power Output, kWm 502 552
Net Engine Power Output, kWm 486 536
75% Load Fuel Consumption, L/h 94.2 103
100% Load Fuel Consumption, L/h 123.6 135.4
Cooling System Water tank, axial fan.
Compression Radio 15 :1

 Speccifications are subject to change without prior notice


Doosan PDS-600

Rated Speed, rpm 1500


Piston Speed, m/s 7.1
Governor Type Electric type
Starting Voltage 24V

ALTERNATOR SPECIFICATIONS
Alternator Manufacturer STAMFORD NEWAGE
Alternator Model HCI544E
Exciter Type Single Bearing, Brushless & Self-excited
A.V.R SX440
Rated Output Prime Power, kVA 610
Rated Speed, rpm 1500
Rated Frequency, Hz 50
Phase 3
Rated Power Factor 0.8
Insulation System Class H
Protection IP23
Rated Voltage 400V (Available with customer requirements)
Stator Winding Double Layer Lap
Winding Pitch Two Thirds
Voltage Adjust Range ≥5%
Voltage Regulation NL-FL ≤±1%

GENSET OUTLINE (mm)


OPEN ENCLOSED

Note
:
- This outline drawing is to provide representative configuration details for Model series only.
- See respective model data sheet for specific model outline drawing number.
- Do not use for Installation design.

 Speccifications are subject to change without prior notice


Doosan PDS-600

WEIGHTS
Type Open Enclosed
Unit dry weight, kg 3670
Unit wet weight, kg

DIMENSIONS
Lenght Width Height
Standard open set dimensions, mm 3210 1610 2620
Enclosed set standard dimensions, mm

CONTROL PANEL
Standard Control Panel is the configuration for nobody on duty
controlling generators. This kind of panel adopts auto module control
system, with large LCD display to show the menu.
Features:
 MRS11-can receive remote output signal from ATS and realize auto
start and stop of generators.
 MRS16-can realize all functions of MRS10, add RS232 interface
which can communicate with PC to realize remote operation.
 AMF25-Auto Mains Failure controller, can realize all functions of
MRS16, furthermore can detect ATS and control.

See your distributor for more information.

EUROPOWER TECHNOLOGYPTE.,LTD.
71Tech Park Crescent Tuas Tech Park,
Singapore 638072

 Speccifications are subject to change without prior notice