You are on page 1of 2

ACA 3 Operating elements

DC ON/OFF/LIMIT LEDs
Front

DC ON
ON/OFF
DC LIMIT
DC OFF

ACA 3
RF ON/OFF
A1 B1 A2 B2 A3 B3 A4 B4
DC ON
DC LIMIT
DC OFF
PUSH & HOLD DC ON/OFF
RF ON/OFF
PUSH & HOLD DC ON/OFF
ACA 3
ACA 3

RF/DC ON/OFF LEDs


EU US UK

Back BNC socket BNC socket


RF OUT A RF OUT B
Quick Guide Kort vejledning
Kurzanleitung Pikaohje
Guide de démarrage rapide Γρήγορος οδηγός
Guida rapida Kısa Kılavuz
Instrucciones resumidas Краткая инструкция
Instruções resumidas 快速指南
RF in A1 RF in A3 RF out A RF in B1 RF in B3 RF out B
Beknopte gebruiksaanwijzing 快速使用指南 WARNING: DO NOT CONNECT
TRANSMITTING DEVICES

Krótka instrukcja obsługi クイックガイド


DIRECTLY TO THIS UNIT

ANTENNA RF INPUTS ATTENTION: NE PAS CONNECTER


DC OUT 12V/450mA D‘EMETTEUR DIRECTEMENT A

Snabbguide 퀵 가이드
CET APPAREIL

Safety 100-240 V~/50-60 Hz/1 A RF in A2 RF in A4 RF in B2 RF in B4

Quick Guide
Guide
Mains socket 4 BNC sockets 4 BNC sockets
BNC socket A1 to A4 RF IN B1 to B4 RF IN
RF OUT A DC OUT DC OUT

Setup ON/OFF

ON/Standby
short long

ACA 3 on standby
A1 B1 A2 B2 A3 B3 A4 B4
DC ON

LED on blinking
DC LIMIT
DC OFF

RF ON/OFF
PUSH & HOLD DC ON/OFF

Sennheiser Documentation App LED RF by off


RF in A1 RF in A3 RF out A RF in B1 RF in B3 RF out B ACA 3
WARNING: DO NOT CONNECT
TRANSMITTING DEVICES
DIRECTLY TO THIS UNIT

memory
ANTENNA RF INPUTS ATTENTION: NE PAS CONNECTER
DC OUT 12V/450mA D‘EMETTEUR DIRECTEMENT A
CET APPAREIL

100-240V~/50-60 Hz/1A RF in A2 RF in A4 RF in B2 RF in B4

LED DC by off
memory

OFF

or online at
www.sennheiser.com/download
100 - 240 V~
ACA 3_ RF in A1 RF in A3 RF out A RF in B1 RF in B3 RF out B
WARNING: DO NOT CONNECT
TRANSMITTING DEVICES
DIRECTLY TO THIS UNIT

ANTENNA RF INPUTS ATTENTION: NE PAS CONNECTER


DC OUT 12V/450mA D‘EMETTEUR DIRECTEMENT A
CET APPAREIL

Sennheiser electronic GmbH & Co. KG 100-240V~/50-60 Hz/1A RF in A2 RF in A4 RF in B2 RF in B4

Am Labor 1, 30900 Wedemark, Germany


www.sennheiser.com

Printed in Germany, Publ. 10/19, 583927/A01

Specifications Operating modes

Frequency range 470 - 798 MHz


Gain 0 dB (±3 dB) @ 470-790 MHz
Output voltage 12 V, 250 mA max (overload protected)
DC ON
DC LIMIT
DC OFF
Connector BNC female, 50 ˝
Power supply 100-240 V~/ 50-60 Hz / 1A
RF ON/OFF
PUSH & HOLD DC ON/OFF
ACA 3
RF input +10 dBm max 10 mW / channel
RF output IP3: >37 dBm (typ.); 1 dB cp: >20 dBm
Specials Channel isolation (when switched OFF): 69 dB (typ.)
Operating relative humidity 5 to 95% RF ON/OFF + LED LED DC
DC ON/OFF
Operating temperature range -10 °C to +40 °C
Storage temperature range –20 °C bis +70 °C
Dimensions (incl. rack mount ears) approx. 43 x 483 x 205 mm
Format 19 inch, 1U
Weight (incl. plug, cable) approx. 2750 g
short long LEDs DC RF
on
Setup
RF on/off -
blinking LIMIT -
OR
DC - on/off off

Connecting devices

ESC

SYNC
SYNC

Transmitter

RF out A RF out B

WARNING: DO NOT CONNECT


TRANSMITTING DEVICES
DIRECTLY TO THIS UNIT
RF in A1 RF in A3 RF in B1 RF in B3 ATTENTION: NE PAS CONNECTER
D‘EMETTEUR DIRECTEMENT A
2 x 4 ANTENNA RF INPUTS CET APPAREIL
DC OUT 12V ˛ 250mA
100-240V~/50-60 Hz/1A
RF in A2 RF in A4 RF in B2 RF in B4

Receiver > 0.5 m

>1m
Example 1: Studio Comlex

RF IN A1 - A4

RF IN B1 - B4

Studio 1 Studio 2 Studio 3 Studio 4

4x RF IN 4x RF IN
4x DC OUT 4x DC OUT

A1 B1 A2 B2 A3 B3 A4 B4
DC ON
DC LIMIT
DC OFF

RF ON/OFF
PUSH & HOLD DC ON/OFF
ACA 3

Example 2: Large Church

RF IN A1 - A4

RF IN B1 - B4

4x RF IN 4x RF IN
4x DC OUT 4x DC OUT

A1 B1 A2 B2 A3 B3 A4 B4
DC ON
DC LIMIT
DC OFF

RF ON/OFF
PUSH & HOLD DC ON/OFF
ACA 3

You might also like