You are on page 1of 2

Technical Data comparison between two systems

Systems A30828-X1130-V-1-7618 ‫ﯾﺠﺐ ﻛﺘﺎﺑﺔ رﻗﻢ اﻟﻨﻈﺎم اﻟﻘﺪﯾﻢ‬ Units


(‫)اﻟﻤﺴﺘﺨﺪم‬

General System Data

Busy hour call 4,000,000 More than 1000,000 BHCA


attempts
(BHCA)
Operating V or -60 V dc 48- V or -60 V 48- Volt
Voltage
Clock ,plesiochronous 10​-9 ,plesiochronous 10​-9 N/A
accuracy, synchronous 10​-11 synchronous 10​-11
maximum
relative
frequency
deviation
Performance in accordance with ITU-T Data as per CCITTRec. N/A
and reliability recommendations Q.541 Q504, Q514
and Q.543
Transmission in accordance with ITU-T Data as per CCITTRec. N/A
characteristics recommendation Q.551 Q507, Q517

Exchanges

Number of 600,000 Up to 250,000 Subscriber


lines
Subscriber
Lines
Number of 240,000 Up to 60,000 Trunks
Trunks
Switching 100,000 25,200 erlangs Erlangs traffic
capacity
capacity

Digital Line Unit


32-port subscriber line Up to 950 Subscriber
lines
module
2000 subscribers per DLU N/A
(0.1 Erl.)
1550 subscribers per DLU N/A
(0.25 Erl.)

ISDN Lines

Basic access 160 Kbit/s 144 Kbit/s (2B + 1D+ B= 64Kbit/s;


D= 16Kbit/s
(2B + 1D+ sync.) sync.)
Primary rate 2,048 Kbit/s (30B+1D+sync.) 2,048 Kbit/s B=D=64Kbit/s
access or (30B+1D+sync.)
1,544 Kbit/s (23B+1D+sync.) or
1,544 Kbit/s
(23B+1D+sync.)