RAPID RESPONSE
WWW.GALVANIC.COM 0020422:800260 WWW.GALVANIC.COM
SUPERIOR ACCURACY
Galvanic Applied Sciences Inc. Houston, Texas, USA Toll Free
7000 Fisher Road S.E.
Calgary, Alberta T2H 0W3
13211K Windfern Rd
Houston, TX 77064
1-866-252-8470 REDUCED COST AND MAINTENANCE
Telephone: 403-252-8470 Telephone : 281-477-9002 (US & Canada only)
Fax: 403-255-6287 Fax: 281-477-9004 OVER-RANGE & MULTI-RANGE CAPABILITY
W W W. G A LVA N I C . C O M • E - M A I L : I N F O @ G A LVA N I C . C O M
903 H2S TAPE ANALYZER 903 COLORIMETRIC SENSOR
The Galvanic Applied
The 903 Sensor Block achieves cutting precise by making accurate measurements at the source of the
Sciences Leadership continues Galvanic's 903 H2S Tape Analyzer is designed to measure up to 4 streams of hydrogen
chemical reaction. All measurements, diagnostics, and calibrations are performed by an independent
sulphide ( H2S) and total sulphur in gaseous streams. The new 903 H2S Tape Analyzer has the
Galvanic is the leading supplier of microprocessor on the sensor block.
same rapid 20 second response time of the traditional lead acetate tape, while making
H2S / Total Sulphur analyzers in unprecedented advances in accuracy and linearity, and reduced operation cost. • Microprocessor controlled sensor • Digital signal processing for best
the world. Our foundation is built on compensates for drift, aging and accuracy and repeatability
These advances are based on a patent pending algorithm and advanced digital sensor tape variances • Automatic light emitter intensity
years of innovation, leadership and
technology developed by Galvanic. • Automatic zero set compensation
customer satisfaction.
The 903 H2S Tape Analyzer new capabilities include: • Automatic span set • 24 Bit ADC converter for
Experienced • Remote diagnostics measurement in situ
• 0-2000 ppm range without dilution - at least 50 times greater than traditional
Over 25 years of experience. tape analyzers;
• Linearity and repeatability of just ± 1% of full scale;
MULTI-STREAM MULTI-RANGE
Established • 5-15 week tape life - up to 2 times greater than that of traditional tape analyzers; and Galvanic‘s 903 has the ability to measure more than one stream of varying concentration. Traditionally
Galvanic is a reliable and trusted • Over-range and multi-range measurement two analyzers were required when the concentration of two streams were significantly different. The
name in H2S analysis. Operators can now measure the extent to which H2S exceeds pre-set alarm levels as well as patent pending 903 algorithm allows one analyzer to measure 2 - and up to 4 - streams that have
use the quick response H2S analyzer in new, higher ppm applications. concentrations differing by up to 2 orders of magnitude. For example, one analyzer could be used to
Customer Service measure H2S in the 0-10 ppm range and Total Sulphur in the 0 -500 ppm range.
In addition, the 903 H2S Tape Analyzer can read samples from different ranges. This multi-
Our experienced field support range capability replaces the need for separate analyzers calibrated each for separate streams.
team is always there to meet your CONFIGURABLE SOFTWARE
Other new features of the 903 H2S Tape Analyzer include built-in modbus communications /
requirements. The 903 comes with a Windows application which can be used to configure and
RTU capabilities, a greater number of outputs and inputs, sensor auto-calibration on each
analysis and dual redundant power supply. monitor its operation. All aspects of the 903 can be configured including alarms,
sequence of analysis operation, digital inputs, digital outputs, analog inputs, analog
The 903 H2S Tape Analyzer also comes with a total sulphur option. Using the multi-range outputs, communications, and logging. Monitoring is achieved using the Analysis
capability 1 unit can measure up to 4 separate H2S and total sulphur streams of varying window, with further break downs of alarms on the Alarm window, and IO using the
APPLICATIONS: concentrations. Status window. In addition it is possible to download logs of analysis results, and an audit
trail showing alarms and configuration changes.
• Natural Gas Processing
• Natural Gas Transmission COMMUNICATIONS
• Liquified Petroleum Gas
• Liquified Natural Gas 903 IS THE MOST ADVANCED TAPE With built-in MODBUS communications / RTU capabilities, The 903 is equipped with
• Petrochemical Feedstock RS - 485 & RS - 232 communication ports. The 903 supports Modicon and Enron
• Fuel Cell
ANALYZER ON THE MARKET OFFERING: MODBUS protocols. The 903 can also take analog signals from other analyzers and
output the data via MODBUS communications.
• Refining Rapid Alarm
• Emission Monitoring 20 seconds to alarm
TOTAL SULPHUR OPTIONS
Reduced Cost and Maintenance
Up to 2 times greater tape life than other analyzers The hydrogenation reaction furnace allows a standard Galvanic Applied Sciences H2S analyzer
Auto-calibration of digital colorimetric sensor tomeasure total sulphur concentration.
Tape measurement output
The sample is mixed with a hydrogen stream and heated to approximately 900°C. At this temperature
Greater Accuracy in the presence of hydrogen all sulphur compounds will be converted to H2S. Also, any hydrocarbon
Dynamic Range: 0-2000 ppm with no dilution; 0-100% with dilution heavier than methane will be cracked to form methane.
Linearity: ±1% of full scale
Repeatability: ±1% of full scale at > 1ppm Examples of the sulphur reaction are:
900°C 900°C
Enhanced Communications COS + 4H2 ➪ CH4 + H2O + H2S (CH3CH2)2S + 4H2 ➪ 4CH4 + H2S
Built-in RTU capabilities: MODBUS on RS-232, Carbonyl Sulphide Diethyl Sulphide
RS-485, USB, Ethernet & Arcnet Increased I/O 900°C 900°C
Analog: 6 outputs & 4 inputs (CH3)2S + 2H2 ➪ 2CH4 + H2S C4H10 + 3H2 ➪ 4CH4
Digital: 8 inputs, 6 relays & 8 solenoid drivers Dimethyl Sulphide Butane: Example of Cracking
Uninterrupted Operation
Dual redundant power supply
LEAD ACETATE TAPES
Up to 4 Streams Galvanic’s controlled plant environment ensures top quality in our lead acetate tapes.
Over-range and Multi-range Measurement Our automated process and constant quality checks ensure consistent product. All our
tapes are cleaned after treatment to minimize problems caused by paper dust. We can provide tape
lengths up to three hundred and fifty feet. Analyzers run cleaner and smoother with Galvanic’s tape.
Uninterrupted Operation
Dual redundant power supply
LEAD ACETATE TAPES
Up to 4 Streams Galvanic’s controlled plant environment ensures top quality in our lead acetate tapes.
Over-range and Multi-range Measurement Our automated process and constant quality checks ensure consistent product. All our
tapes are cleaned after treatment to minimize problems caused by paper dust. We can provide tape
lengths up to three hundred and fifty feet. Analyzers run cleaner and smoother with Galvanic’s tape.
RAPID RESPONSE
WWW.GALVANIC.COM 0020422:800260 WWW.GALVANIC.COM
SUPERIOR ACCURACY
Galvanic Applied Sciences Inc. Houston, Texas, USA Toll Free
7000 Fisher Road S.E.
Calgary, Alberta T2H 0W3
13211K Windfern Rd
Houston, TX 77064
1-866-252-8470 REDUCED COST AND MAINTENANCE
Telephone: 403-252-8470 Telephone : 281-477-9002 (US & Canada only)
Fax: 403-255-6287 Fax: 281-477-9004 OVER-RANGE & MULTI-RANGE CAPABILITY
W W W. G A LVA N I C . C O M • E - M A I L : I N F O @ G A LVA N I C . C O M
151909_Galvanic_BRO 3/30/04 10:37 AM Page 1
TYTRONICS®
SENTINEL
THE WATCHDOG OF CHEMICAL
ANALYSIS AND WATER MONITORING
WWW.GALVANIC.COM
151909_Galvanic_BRO 3/30/04 10:37 AM Page 2
Whether you are currently analyzing or monitoring liquids, or looking to do so, the
Tytronics® Sentinel is your first choice in on-line analysis or monitoring.
EASE OF OPERATION
Simple menu-driven operation and a modular design make the Tytronics® Sentinel easy
to use and maintain. A person with little chemical background can use the analyzer with
minimal training. Simple step by step instructions are displayed to guide the operator
through the procedure to complete a calibration and to set the unit in the automatic
analysis mode.
CALIBRATION: True multi-featured two point calibration technique allows trace analysis to be
routinely checked by simply using distilled water. Periodic checking of span standard can be
easily performed.
Titrator
Tytronics® Sentinel on-line colorimetric and potentiometric (pH and Redox) Titrations deliver
simple, reliable and highly cost-effective on-line analysis. Acids, Alkalinity, Caustic,
Carbonate, Cyanide, Hardness, Iron, Peroxide, Silver and many other analyses are common
applications across a wide variety of process industries. Tytronics’® Sentinel Titrators have the
capability of performing single or dual end-point titrations. The Titrator is equipped with three
detection methods (fixed, relative and derivative endpoint) to insure flexibility and accuracy.
Expanded diagnostic capabilities include programmable learn cycles to automatically detect
chemistry endpoints. Users may program several methods and the system allows for multiple
reagents to be added. Analyses are fully automatic in all cases. Users can easily change the
frequency of analysis and calibration, as well as most of the default values, to improve or
customize a setup; three different access levels provide system security. The Tytronics® Sentinel
also features a full auto-cleaning capability for reliability and reduced maintenance. In sum,
this results in an extremely reliable, flexible, and user-friendly general purpose Titrator.
ISE
Potentiometric sensors are used for ion selective measurements. The single known addition
(SKA) technique compensates for electrode drift on every analysis. Tytronics® Sentinel ISE
analyzer is fitted as standard with an RTD-100 temperature sensor which permits automatic
temperature compensation of the analysis. Direct Method is used for high concentration
analysis.
TYTRONICS ®
Galvanic Applied Sciences USA manufactures the complete brand of Tytronics® on-line wet
chemical and gas analyzers. The Tytronics® products include the Sentinel On-line Analyzers.
These analyzers use "state of the art" technology to perform colorimetric, titrimetric, ISE,
and spectrophotometric analyses. These analyzers can be configured to perform many
EPA and ASTM wet chemical methods, as well as many Standard Methods. The Sentinel
analyzers use a modular design that can be configured to meet the specific requirements of
the customer's application.
The Sentinel Analyzers are capable of both process chemical analysis and the monitoring
of potable water and wastewater. This instrument can analyze up to six streams for the same
chemical parameter, at different concentration ranges. The Sentinel can measure the
chemical composition of liquid processes from A (aluminum) to Z (zinc).
FEATURES
MULTI-STREAMING: The instruments can be expanded to analyze up to 6 sample streams per
analyzer. The frequency and order of stream analysis is fully programmable. Each stream has a
separate alarm and analog output with multi-range capability. The ability to optimize the method
used for each sample stream further proves the superiority of the advanced capabilities of the
Tytronics® Sentinel.
SAMPLE STREAM: Flow rate of 50 to 900 ml/min; pressures from 0 to 50 psig; temperature
from 5˚ to 70˚ Celsius and 1/4” sample inlet connection.
OPERATING TEMP: 5˚ to 45˚ Celsius; vortex air cooler recommended above 45˚ Celsius
ANALOG OUTPUTS: 1 output per stream; isolated 0/4 to 20 mA; fully range-programmable;
maximum load 1000 Ohms; result values are held until the reading is updated.
DIGITAL OUPTUTS: Dual-isolated RS-232C for printer and computer interface at user-
selected baud rates, with remote control capability.
DIGITAL INPUTS: 8 digital inputs with fully programmable functions allow interface to a PLC and/or
interface to voltage-free contact from sensors; expandable to 16 inputs with multiplexor board option.
ALARMS: Stream-specific High and Low set point alarms; loss of sample flow alarm; fail-safe
power failure alarm; general, hardware and stream-specific fault signals,; result-ready, test-in-
progress, calibration-in-progress and other alarm and interface functions (consult Manual); alarms
can be assigned in software to voltage-free contact relays; grouping of alarms to relays is fully
programmable.
DATA STORAGE: Non-volatile memory saves the last 120 analysis results and last 25
calibration results; data retention is approximately 5 years.
SENTINEL 03 - 04 Printed in Canada
POWER SUPPLY: Universal power supply 100 to 240 VAC, 50-60 Hz; consumption 200 watts
maximum.
ENCLOSURE TYPE: IP65, NEMA 4X, fiberglass wall-mounted industrial enclosure; modular design
of the fluidic and electronic sections results in easy maintenance and simple field retrofits or upgrades.
Galvanic Applied Sciences USA Inc. Galvanic Applied Sciences Inc. Calgary, Alberta Edmonton, Alberta
41 Wellman Street Bay 6, 6325-12 Street S.E. 1200, 715-5th Avenue S.W. Telephone: 780-430-0142
Lowell, MA. 01851 Calgary, Alberta T2H 2K1 Calgary, Alberta T2P 2X6 Fax: 780-430-0172
Telephone: 978-848-2701 Telephone: 403-252-8470 Telephone: 403-252-8470 Houston, Texas
Fax: 978-848-2713 Fax: 403-255-6287 Fax: 403-571-2684 Telephone: 281-477-9002
Fax: 281-477-9004
Toll Free 1-800-370-2345 (US only)
W W W. G A LVA N I C . C O M • E - M A I L : I N F O @ G A LVA N I C . C O M
Model BRM 941-LS
Liquid Sulphur Analyzer System
Analyzer H2S and H2Sx in Liquid Sulphur
Residual H2S in Claus‐produced sulphur contains both H2S and H2Sx, which exist in
equilibrium with elemental sulfur (S8).
• Analyses can be conducted in 2 minutes
(wet chemical method requires several hours)
• Analyses independent of operator skill
The use of state ‐of‐ the‐ art Fourier transform infrared spectrometers allows the
resolution of the H2S and H2Sx absorptions giving accurate (± 10% of the measure‐
ment value) determinations of total H2S in the 0‐350 ppmw range with quantification
down to 2 ppmw.
Key Component
FTIR Analyzer
Calibrated heated cell
Sulphur sampling device (hot pot)
Proprietary software package
info@galvanic.com • www.galvanic.com
WWW.GALVANIC.COM
PLGC II
GAS CHROMATOGRAPH
WWW.GALVANIC.COM
PLGC II GAS CHROMATOGRAPH FOR
PIPELINE AND PROCESS APPLICATIONS
2 3
5 The PLGC II is a compact and low cost gas chromatograph equipped with a universal
1 thermal conductivity detector. The unit offers a wide range of applications where
4
hydrocarbon gas or fixed gas analysis is required, such as in BTU measurement for the
natural gas industry.
6 Remember when field chromatography was considered too complex or expensive for
many applications. The PLGC II removes these drawbacks. The Galvanic Applied
7 Sciences PLGC II analyzer is a low cost, low maintenance chromatograph. The PLGC II
8 can be used in many measurement applications where an isothermal TCD scheme is
suitable. The PLGC II is fully automated and designed to perform on-line, real time
6 analysis. The Windows® based configuration program allows the user to view most
recent or saved chromatograms as well as configure the analyzer.
Features:
5 Customer Connections for Helium carrier TCD Detection 8 Milliamp Constant Current
4
R
ED
R
B
G
6 A-A Mount
5 6
1
10
The chromatograph is composed of 2
9
a 10-port micro volume diaphragm PLGC II Sample Handling Equipment 3
valve and generally 2 columns 8 Carrier
4
(some applications may only col 1
require one). The DV22 performs 7
6
5
The PLGC II software has been designed to receive, interpret, and plot data from the
PLGC II gas chromatograph. Peaks in the resulting chromatogram identify the
compounds by retention time and the concentration by the area of the peak. Various
parameters, including heating value, specific gravity, and compressibility factor, can be
displayed with the software. The Graphical User Interface (GUI) for the software is a
user friendly Windows® based system.
Computer Requirements:
Operating System:
DIMAC Gas Chromatogram
®
An IBM compatible PC with “Windows 98,
NT or ME” operating system will be required.
Memory:
The PC must have a minimum of 64 MB of
RAM and Windows®98.
Disk Drives:
The PLGC II configuration program is
provided on CD Rom, and requires at least
20MB on the disk drive. Extra space will be
required to save data.
Serial Port:
To run the PLGC II configuration program a
serial cable is required to connect the
personal computer to the PLGC II. Most
computers will have multiple COM ports to
select from. The COM port selected cannot
be shared with any other device.
SPECIFICATIONS
Outputs: Weight:
240 x 64 backlit LCD 35 pounds
Electrical: Weight:
120/240 VAC @ 50 watts 50 pounds
PLGC II 10 - 03 Printed in Canada
Dimensions:
29” H X 13” W X 9” D
Galvanic Applied Sciences Inc. Calgary, Alberta Edmonton, Alberta Houston, Texas
Bay 6, 6325-12 Street S.E. 1200, 715-5th Avenue S.W. Telephone: 780-430-0142 Telephone: 281-477-9002
Calgary, Alberta T2H 2K1 Calgary, Alberta T2P 2X6 Fax: 780-430-0172 Fax: 281-477-9004
Telephone: 403-252-8470 Telephone: 403-252-8470
ISO 9001: 2000 Fax: 403-255-6287 Fax: 403-571-2684
Registered QMS
Toll Free 1-866-252-8470 (US & Canada only)
W W W. G A LVA N I C . C O M • E - M A I L : I N F O @ G A LVA N I C . C O M