Solution Number: 68876

Solution Summary: Timbermatic 300 / 700; machine profiling in TMC 2.11 / 4.07->

Publication Date: Jul 4 2005

**Paper copies of solutions may not be the most current solutions**

Complaint or Symptom:

TMC parameters are not ok after program loading.

Problem or Situation:

Follow program loading instructions for 3G+ / 4G from T300:11 bulletin very carefully. If ignition is switched off
too early after module programming the system can't make automatic machine profiling after restarting.
Machine profiling can be done manually but in some cases default settings for the machine type must be done
first.

Solution:

To make default settings (factory settings):


- open service mode
- activate operator F
- go to MCH window
- select machine type, press OK
- select StartUp (System creates default machine profile and sends parameters to modules.)

Check functions of the machine and parameters in TMC and adjust if needed. Make machine profiling
manually.

To make machine profiling manually,


- open service mode
- activate operator F
- go to MCH window
- select machine type, press OK
- select Profile
- set serial number
- press Create (If there is existing machine profile for the serial number you can send all parameters to
modules by the Send button.)
Check all settings, and activate all operators one by one.