You are on page 1of 25

Criterios de diseño de tubería

“Tenaris has produced this document for general information only, and the information in this document is not intended to constitute professional or
any other type of advice or recommendation and is provided on an “as is” basis. No warranty is given. The use of the information is at user’s own
risk and Tenaris does not assume any responsibility or liability of any kind for any loss, damage or injury resulting from, or in connection with any
information provided hereunder or any use thereof. The information in this document is subject to change or modification without notice. Tenaris’s
products and services are subject to Tenaris’s standard terms and conditions or otherwise to the terms resulting from the respective contracts of
sale or services, as the case may be. Unless specifically agreed under such contract of sale or services, if Tenaris is required to provide any warranty
or assume any liability in connection with the information provided hereunder, any such warranty or liability shall be subject to the execution of a
separate written agreement between user and Tenaris. This document as well as the information contained herein are confidential and are owned by
or licensed to Tenaris and/or its affiliated companies, and may not be copied, recopied, reproduced, translated, disclosed, adapted, changed or
distributed nor used for any purpose whatsoever without the prior and written permission of Tenaris. For more complete information please contact
a Tenaris's representative or visit our website at www.tenaris.com. ©Tenaris 2015. All rights reserved”.

09 de agosto de 2017
Agenda

• Diseño y selección de tubulares


• Prestación de tubulares
• Métodos de diseño
• Factores de diseño
• Casos de carga por tipo de tubular

Métodos de diseño Workshop Ecopetrol - Tenaris


Diseño y Selección de Tuberías

Desafíos en el Pozo
Diseño del Resistencia a
corrosión &
Casing fisuración
(Casos de carga,
ambiente, servicio) Cargas múltiples
Exploración-
Perforación Perfiles térmicos
(Servicios
asociados) Dinámica de fluidos
Performance
Interacción entre de Producto
Casing +
Cementación fluidos y materiales
(corrosión) Performance
Propiedades
Completación mecánicas estructural Dimensiones

Producción Condiciones de trabajo


Etc.

Métodos de diseño Workshop Ecopetrol - Tenaris


Diseño y Selección de Tuberías

Desafíos en el Pozo
Normativa regulatoria
Diseño del Resistencia a
corrosión &
Casing fisuración
(Casos de carga,
ambiente, servicio)
• API 5CT
Exploración-
Perforación • NACE MR0175
(Servicios
asociados) /ISO15156
Performance

Casing +
• API 5C3 / ISO 10400 de Producto

Cementación
• API 5C5 / ISO13679
Performance
Completación
• Especificaciones Propiedades
mecánicas estructural Dimensiones

Producción
propietarias Condiciones de trabajo
Etc.

Métodos de diseño Workshop Ecopetrol - Tenaris


Prestación de los tubulares

Cuerpo de la Tubería (Pipe Body)


• Resistencia a la Tracción / Compresión.
• Resistencia a la Presión Interna.
• Resistencia al Colapso.

Conexión
• Resistencia a la Tracción
• Resistencia a la Compresión
• Resistencia a la Presión Interna.
• Resistencia al Colapso.
• Resistencia a la Flexión.
• Resistencia al sobre-torque

Métodos de diseño Workshop Ecopetrol - Tenaris


Prestación de tubulares

• Resistencia axial: Py 
4
(D 2  d 2 ).Yp

• Resistencia a estallido: 0.875 2 Yp t


Pe 
D

• Resistencia a colapso:
Fluencia Plástico Transición Elástico
 D / t 1  A
Pp Yp 

B  C  F  PE 
46.95x10 6
Py  2 Yp  PT Yp  G 
2  D / t D / t D / t 12
 D / t  
p  D / t 

Py = resistencia del cuerpo del tubo a la Fluencia D = Diámetro externo (in)


Yp = Tensión de Fluencia mínima especificada d = Diámetro interno (in)
API: 5C3
Métodos de diseño Workshop Ecopetrol - Tenaris 09 de agosto de
2017
Métodos de diseño
Pasos a seguir…

Diseño preliminar: Diseño de detalle:


• Recolección e interpretación de • Definición del Peso lineal (lb/ft o kg/m)
datos. para cada tipo de tuberías.
• Gradientes de presión y de • Selección del material (Grado de
temperatura. Acero) para cada tipo de tuberías.
• Selección del Tubing. • Determinación y Selección de las
• Selección de los Casing. conexiones.
• Análisis de huelgos. • Especificación del Nivel de producto
• Determinación de las profundidades (PSL) API Spec 5CT / ISO 11960.
de los zapatos y las ventanas de • Obtención de los factores de diseño
densidad de fluidos. de cálculo.
• Evaluación del riesgo.

Métodos de diseño Workshop Ecopetrol - Tenaris


Métodos de diseño
Pasos a seguir…

Dimensión del Casing depende del el mínimo diámetro interno del Tubing
necesario para poner en producción el pozo.

El pozo debe asegurar el flujo que económicamente justifique el proyecto,


manteniendo bajo control técnico variables como: caudal, erosión, tipo de
completamiento, etc.

Producción ID Tubing OD Tubing

OD Box Tbg ID Csg Prod OD Csg Prod

OD Box Csg OD Broca ID Csg Intermedio

Métodos de diseño Workshop Ecopetrol - Tenaris


Secuencia de tamaños tradicionales
casing-broca
Barker J.W. (1978)

• Se debe prestar especial atención a:


 El tipo de la conexión.
 Peso del lodo, viscosidad y Yield
Point.
 El proceso de cementación.
 Doglegs y trayectoria.

Tamaños de hueco y de brocas


usados usualmente.
Menos usados.

Métodos de diseño Workshop Ecopetrol - Tenaris


Métodos de diseño
Pasos a seguir…
¿Cómo determinó que tuberías son adecuadas para resistir las
solicitaciones generadas en las hipótesis de carga asumidas?
Factor
de
 Monoaxial Diseño
Determinísticos
 Biaxial
 Triaxial (ACTUAL)

Carga Resistencia

Probabilísticos

Métodos de diseño Workshop Ecopetrol - Tenaris


Métodos de diseño

Factor de diseño:

Resistencia mínima especificada del Tubo


Factor de Diseño =
Máxima carga esperada durante el Servicio

El “tubo” implica al cuerpo (PIPE BODY) y a la conexión, y se


trabaja con el de menor prestación

Métodos de diseño Workshop Ecopetrol - Tenaris


Métodos de diseño
El rol del factor de diseño en el diseño de detalle:
Los factores de diseño se utilizan para cubrir incertidumbres.

Resistencia Media

Probabilidad Carga Media


Margen de
Seguridad
Promedio

Mínima
Peor Carga resistencia
esperada del Tubo

Incertidumbre en
Incertidumbre en la resistencia
la Carga Factor de Diseño

Métodos de diseño Workshop Ecopetrol - Tenaris


Factores de diseño - Cálculo
Mínima presión interna de fluencia
FDESTALLIDO =
Máxima presión interna diferencial anticipada

Resistencia al colapso del tubo


FDCOLAPSO =
Presión de colapso equivalente

Resistencia mínima a la tracción


FDTRACCION =
Máxima carga estática de tracción anticipada

Resistencia mínima a la compresión


FDCOMPRESION =
Máxima carga estática de compresión anticipada

 axial
 VME  radial
Tensión mínima de fluencia del tubo
FDVON MISES =
Tensión equivalente de Von Mises
 circunferencial
Triaxial

Métodos de diseño Workshop Ecopetrol - Tenaris


Factores de diseño sugeridos por
Tenaris

Tipo de Carga Tuberías Intermedias Tuberías de Producción


1.25 o 1.10 si se considera
Estallido 1.25 o 1.35 para “sour service”
“wear loss”
1.10 o 1.125 o 1.00 si se 1.10 o 1.125 o 1.00 si se
Colapso
considera “wear loss” considera “wear loss”

1.80 o 1.75 o 1.55 si se 1.80 o 1.75 o 1.55 si se


Tracción
considera “overpull” considera “overpull”

Compresión 1.20 1.20

Von Mises 1.25 1.25 o 1.35 para “sour service”

Métodos de diseño Workshop Ecopetrol - Tenaris


Métodos de diseño
Presión Interna
8160 psi Ej: 7” 29# N80 TSH
Diseño Monoaxial: Blue
7100 psi
Ventana API No OK

Ventana API / FD

FD Colapso = 1.12
FD Presión Interna = 1.15
Compresión Tracción
FD Tracción = 1.75

390000 lb
FD Compresión = 1.2

676.000 lb
676000 lb

563000 lb

Colapso = 7030 psi / 1.12 = 6270 psi OK


Presión Interna = 8160 psi / 1.15 = 7100 psi
Tracción = 676000 lb / 1.75 = 390000 lb 6270 psi
Compresión = 676000 lb / 1.2 = 563000 lb

7030 psi
Colapso

Métodos de diseño Workshop Ecopetrol - Tenaris


Métodos de diseño

Diseño Biaxial:
El método biaxial considera interacciones de dos variables independientes (p.ej. Resistencia al
Colapso en presencia de tensión axial).
  Sa 
2
Sa 

Ypa  1  0.75 .    0.5 . . Yp
  Yp  Yp 
 
Ypa = tensión de Fluencia de grado equivalente por tracción axial (psi)
Sa = tensión axial (psi)
Yp = tensión de fluencia mínima especificada (psi)

La resistencia al colapso en presencia de tensión


axial se calcula modificando la tensión axial de
fluencia a un grado equivalente de tensión axial.

REF: API RP 5C3

Métodos de diseño Workshop Ecopetrol - Tenaris


Métodos de diseño

Diseño Biaxial:
Presión Interna 8160 psi
Ej: 7” 29# N80 TBlue
Venana API
7100 psi

676.000 lb
OK

390000 lb
Ventana API / FD

Compresión Tracción
563000 lb
676000 lb

Efecto Biaxial
6270 psi
No OK

Colapso 7030 psi

Métodos de diseño Workshop Ecopetrol - Tenaris


Métodos de diseño

Diseño Triaxial:
Fundamento de diseño: si la tensión combinada en la pared de un tubo excede la
tensión de fluencia del material se alcanza el potencial de falla (rotura o deformación).
Cargas aplicadas: son complejas y generan un estado de tensiones combinadas que con
los métodos monoaxial y biaxial no se pueden manejar. Se recurre aquí al uso de
computadoras.
Método triaxial: vincula tres tensiones principales actuantes sobre un sólido
determinando una tensión equivalente y comparándola contra la tensión de fluencia del
acero del tubo.  axial
 VME  radial

 circunferencial

Métodos de diseño Workshop Ecopetrol - Tenaris


Elipse de Von Mises

Presión Interna
Elipse de Fluencia del Tubo
(Teoría de von Mises)

Compresión Tracción

Presión Externa

La elipse de Von Mises es una representación de las tensiones equivalentes de Von Mises del cuerpo de
la tubería pero representado en fuerza axial y en presión interna o externa

Métodos de diseño Workshop Ecopetrol - Tenaris


Elipse de Von Mises

Presión Interna Ej: 7” 29# N80 TBlue

Ventana triaxial
OK

Compresión Tracción

Ventana triaxial / FD

No OK

FD Von Mises = 1.25


Colapso

Métodos de diseño Workshop Ecopetrol - Tenaris


Elipse de Von Mises + ventana API

Presión Interna VME / FD


Criterio de aceptación
Venana API

VME
Ventana API / No OK
FD OK

Compresión ZONA Tracción


SEGURA DE
TRABAJO

Efecto biaxial

Colapso

Métodos de diseño Workshop Ecopetrol - Tenaris


Casos de carga – Casing Conductor
Caso de Modo Perfil de Perfil de Perfil de
carga de presión presión temperatura
carga interna externa
MW hasta TOC y
Caso Peso del lodo de Estático o como
Instalación densidad del
base corrida cementación
cemento
Evacuación Peso del lodo de Estático o fluyendo o
Colapso Nulo
completa corrida caliente

Presión en cabeza
Prueba de
Estallido con el peso del lodo Prueba de presión- LOT Estático
presión- LOT
interno

Métodos de diseño Workshop Ecopetrol - Tenaris 09 de agosto de


2017
Casos de carga – Casing intermedio
Caso de Perfil de presión interna Perfil de presión Perfil de
carga externa temperatura
MW hasta TOC y
Instalación Fluido de desplazamiento Como cementación
densidad del cemento

1/3 de Nulo hasta 1/3 de evacuación de DSOHD y Peso del lodo de


Estático
evacuación lodo de perforación de la siguiente sección. corrida

Prueba de Presión en cabeza con el peso del lodo


Estático
presión- LOT interno

Peso del lodo de corrida más intensidad de


Zapato cerrado: MW
Patada de pozo la patada en DSOHD, gradiente del gas
lodo de corrida hasta Circulando
50 bbl o 100 bbl hasta la altura del kick y lodo de
TOC, CMW hasta el
perforación hasta superficie
zapato anterior y PP
Fractura en el
zapato con 1/3 1/3 de la presión de DSOHD en cabeza y Zapato abierto: MW
lodo de corrida hasta Circulando
de BHP en presión de fractura en el zapato
cabeza TOC y PP.

Presión del peso del lodo en DSOHD, peso Presión de poro


1/3 reemplazo-
del lodo hasta 1/3 de DSOHD y un Estático o
Estático o
gradiente de gas de 0 psi/ft hasta circulando
circulando
superficie

Métodos de diseño Workshop Ecopetrol - Tenaris 09 de agosto de


2017
Casos de carga - Productor
Perfil
Caso de Modo de interno Perfil externo Perfil de
carga carga de de presión temperatura
presión
Densidad de lechada
MW de Estático o
Instalación Caso base de cemento o presión
corrida cementado
de poro
Full
Colapso Nulo MW de corrida Estático
evacuation
Zapato cerrado: MW
lodo de corrida hasta
TOC, CMW hasta el
zapato anterior y PP
Fuga
Zapato abierto: MW
superficial en Estallido WHSIP Estático
lodo de corrida hasta
el tubing
TOC y PP.

Presión de poro

Métodos de diseño Workshop Ecopetrol - Tenaris


Casos de carga - tubing
Perfil
Modo
Caso de Perfil interno de externo Perfil de
de
carga presión de temperatura
carga
presión
Instalación Caso base Packer fluid Packer fluid Estático

Estático y fluyendo
Full evacuation Colapso Nulo Packer Fluid
o caliente
Gas Shut In –
WHSIP y gradiente de Estático y fluyendo
Estático y Estallido Packer fluid
gas o caliente
caliente

BHP a la profundidad
de perforación y
Antes de perforar Estallido densidad del fluido de Packer fluid Estático
perforación hasta
superficie.

Métodos de diseño Workshop Ecopetrol - Tenaris