Segundo Parcial de Concreto Armado II. Fecha:07-01-2021
P1. For the beam shown in Fig. 1, compute the reactions at A, B, and C using constant EI. Draw the
shear and bending moment diagrams and design all critical sections, using b=14 in, h=25 in., f’ c = 4ksi,
fy = 40 ksi, and a load factor=2.6.

Figure1
P2. The two-hinged portal frame ABCD shown in Fig. 2 carries a uniform dead load (excluding
self-weight) =2.9 K/ft and a uniform live load of 2.2 K/ft. Design the frame ABCD, the hinges, and
footings using f’ c = 4ksi, fy = 40 ksi, and a beam width of b=14 in. The footing is placed 5 ft below
ground level and the allowable bearing soil pressure is 4 ksf. Use a slab thickness of 8 in.

Figure 2
P3. Design the transverse reinforcement for the beam of a special moment-resisting frame. The beam
is reinforced with five # 6 bars and is 14 × 25 in. The load acting on the beam is WD =4.0 kip/ft,
WL =1.5 kip/ft, and clear span is 24 ft.
P4. Design the reinforcement for a column on the first floor of a four-story building following the
provisions for special moment-resisting frame reinforcement. The column is 30 × 30 in. and 12 ft
high. Nominal flexural strength of the beam framing into the column Mn =650 Kip ⋅ ft. The axial
load acting on the second-floor column is Pu =1,920 Kip, axial load acting on the first floor is Pu
=2000 Kip, and minimum axial load in load combination is 1050 K. The shear force is V u =150 Kip.
Draw the detail of reinforcement.