Test Specification(s): IEC 60068-2-60, Test Ke: Flowing mixed gas corrosion test
[covered by accreditation]
The results relate only to the items tested as described in this test report.
Obermaier
Senior Test Engineer Lab eMobility Jan 30, 2018
SGS Germany GmbH, Hofmannstr. 50, D-81379 Munich is testing facility for
ELECTRO-MECH. COMPONENTS TESTING ENVIRONMENTAL SIMULATION ELECTROMAGNETIC COMPATIBILITY
MEDICAL DEVICE TESTING BATTERY TESTING PRODUCT SAFETY TELECOM CONFORMANCE TESTS
Phone +49 89-787475-100, Fax +49 89-787475-114, Internet www.sgs-cqe.de
Test Report No.:
M38T0004
CONTENTS
1 Summary ..................................................................................................................................4
2 References ...............................................................................................................................4
2.1 Specifications ......................................................................................................................4
3 General Information ................................................................................................................5
3.1 Identification of Client ..........................................................................................................5
3.2 Test Laboratory ...................................................................................................................5
3.3 Time Schedule ....................................................................................................................5
3.4 Participants .........................................................................................................................5
4 Equipment Under Test ............................................................................................................6
5 Test Equipment ........................................................................................................................7
5.1 Test Facility .........................................................................................................................7
5.2 Measuring Equipment .........................................................................................................7
The test report shall not be reproduced except in full without
LIST OF FIGURES
1 Summary
2 References
2.1 Specifications
3 General Information
3.4 Participants
Name Function
Michael Dermühl Testing
Florian Hüller Editor, Testing
Fig. 5 Label Easergy P3G32, method 1 Fig. 6 Label Easergy P3U30, method 1
Fig. 7 Label Easergy P3G32, method 4 Fig. 8 Label Easergy P3U30, method 4
5 Test Equipment
S5523 Data Logger Ahlborn chk Dec 16, 2016 Dec 2017
Temp./Humidity
the written approval of the testing laboratory
Fig. 9 EUTs in the flowing mixed gas chamber (only the framed test samples are part of this
test report
Fig. 10 EUTs in the flowing mixed gas chamber (only the framed test samples are part of this
test report)
The mass increase of coupons 3 and 4 is slightly above the value required by the standard.
The test report shall not be reproduced except in full without
After the test, a short functional test was performed according to customers instructions.
the written approval of the testing laboratory
Due to a malfunction of the climatic chamber the climatic conditions were not met during the
complete test duration. Because of that the mass increase of the coupons is below the required
value.
The test report shall not be reproduced except in full without
After the test, a short functional test was performed according to customers instructions.
the written approval of the testing laboratory
7 Disclaimer
This document is issued by the Company subject to its General Conditions of Service
(www.sgsgroup.de/agb). Attention is drawn to the limitations of liability, indemnification and
jurisdictional issues established therein.
Any holder of this document is advised that information contained hereon reflects the
Company’s findings at the time of its intervention only and within the limits of client’s
instructions, if any. The Company’s sole responsibility is to its Client and this document does not
exonerate parties to a transaction from exercising all their rights and obligations under the
transaction documents. Any unauthorized alteration, forgery or falsification of the content or
appearance of this document is unlawful and offenders may be prosecuted to the fullest extent
of the law.
The test report shall not be reproduced except in full without
the written approval of the testing laboratory