You are on page 1of 49

Dongguan Dongdian Testing Service Co., Ltd. Report No.

: DDT-R19022803-1E1

■Report No.: DDT-R19022803-1E1


■Issued Date: Jun. 03, 2019

ARIB STD-T108 TEST REPORT

FOR

Applicant : RATOC Systems,Inc.


1-6-14, Shikitsu-higashi, Naniwa-ku, Osaka city,
Address : 556-0012 Japan
Equipment under Test : Z-Wave Smart IR Repeater

Model No. : RS-ZWIREX1


Trade Mark : RATOC
Manufacturer : Power7 Technology (Dong Guan) Co., Ltd.
No.28 Binjiang Blvd.Shishuikou Village,Qiaotou
Address : Town,Dongguan City,GuangDong Province
P.R.China

Issued By: Dongguan Dongdian Testing Service Co., Ltd.

Add: No. 17, Zongbu Road 2, Songshan Lake Sci&Tech, Industry Park, Dongguan
City, Guangdong Province, China, 523808
Tel: +86-0769-38826678, E-mail: ddt@dgddt.com, http://www.dgddt.com

Page 1 of 49
Dongguan Dongdian Testing Service Co., Ltd. Report No.: DDT-R19022803-1E1

TABLE OF CONTENTS

Test report declares........................................................................................................4


1. Summary of test results ................................................................................................. 6
2. General test information................................................................................................. 7
2.1. Description of EUT ......................................................................................................... 7
2.2. Antenna specifications ................................................................................................... 7
2.3. Assembly ........................................................................................................................ 9
2.4. Accessories of EUT ....................................................................................................... 9
2.5. Assistant equipment used for test.................................................................................. 9
2.6. Block diagram of EUT configuration for test .................................................................. 9
2.7. Test environment conditions .......................................................................................... 9
2.8. Deviations of test standard .......................................................................................... 10
3. Test laboratory ............................................................................................................. 10
3.1. Measurement uncertainty ............................................................................................ 10
4. Equipment used during test ......................................................................................... 11
5. Frequency Tolerance ................................................................................................... 12
5.1. Limit .............................................................................................................................. 12
5.2. Block diagram of test setup ......................................................................................... 12
5.3. Test Procedure ............................................................................................................. 12
5.4. Test result..................................................................................................................... 12
5.5. Original test data .......................................................................................................... 13
6. Occupied Frequency Bandwidth .................................................................................. 14
6.1. Limit .............................................................................................................................. 14
6.2. Block diagram of test setup ......................................................................................... 14
6.3. Test Procedure ............................................................................................................. 14
6.4. Test result..................................................................................................................... 14
6.5. Original test data .......................................................................................................... 15
7. Antenna Power and Tolerances for Antenna Power ................................................... 16
7.1. Limit .............................................................................................................................. 16
7.2. Block diagram of test setup ......................................................................................... 16
7.3. Test Procedure ............................................................................................................. 16
7.4. Test result..................................................................................................................... 16
8. Adjacent channel leakage power ................................................................................. 18
8.1. Limit .............................................................................................................................. 18
8.2. Block diagram of test setup ......................................................................................... 18
8.3. Test Procedure ............................................................................................................. 18
8.4. Test result..................................................................................................................... 19

Page 2 of 49
Dongguan Dongdian Testing Service Co., Ltd. Report No.: DDT-R19022803-1E1

9. Transmitter Spurious Emissions .................................................................................. 21


9.1. Limit .............................................................................................................................. 21
9.2. Block diagram of test setup ......................................................................................... 21
9.3. Test Procedure ............................................................................................................. 21
9.4. Test result..................................................................................................................... 22
9.5. Original test data .......................................................................................................... 23
10. Secondary Radiated Emissions ................................................................................... 32
10.1. Limit .............................................................................................................................. 32
10.2. Block diagram of test setup ......................................................................................... 32
10.3. Test Procedure ............................................................................................................. 32
10.4. Test result..................................................................................................................... 32
10.5. Original test data .......................................................................................................... 34
11. Controller Measurement .............................................................................................. 40
11.1. Limit .............................................................................................................................. 40
11.2. Block diagram of test setup ......................................................................................... 41
11.3. Test Procedure ............................................................................................................. 41
11.4. Test result..................................................................................................................... 41
11.5. Original test data .......................................................................................................... 42
12. Interference prevention function .................................................................................. 43
13. Test setup photograph ................................................................................................. 44
14. Photos of the EUT ........................................................................................................ 45

Page 3 of 49
Dongguan Dongdian Testing Service Co., Ltd. Report No.: DDT-R19022803-1E1

TEST REPORT DECLARE

Applicant : RATOC Systems,Inc.


1-6-14, Shikitsu-higashi, Naniwa-ku, Osaka city, 556-0012
Address : Japan
Equipment under Test : Z-Wave Smart IR Repeater

Model No. : RS-ZWIREX1

Trade mark : RATOC

Manufacturer : Power7 Technology (Dong Guan) Co., Ltd.


No.28 Binjiang Blvd.Shishuikou Village,Qiaotou Town,Dongguan
Address : City,GuangDong Province P.R.China

Test Standard Used: ARIB STD-T108 Version 1. 2

We Declare:
The equipment described above is tested by Dongguan Dongdian Testing Service Co., Ltd. and
in the configuration tested the equipment complied with the standard specified above. The test
results are contained in this test report and Dongguan Dongdian Testing Service Co., Ltd. is
assumed of full responsibility for the accuracy and completeness of these tests.

After test and evaluation, our opinion is that the equipment provided for test
compliance with the requirement of the above ARIB standard.

Report No.: DDT-R19022803-1E1


Date of Receipt: Mar. 04, 2019 Date of Test: Mar. 04, 2019 ~ Apr. 25, 2019

Prepared By: Approved By:

_______________ ______________________
Ella Gong/Engineer Damon Hu/EMC Manager

Note: This report applies to above tested sample only. This report shall not be reproduced in
parts without written approval of Dongguan Dongdian Testing Service Co., Ltd.

Page 4 of 49
Dongguan Dongdian Testing Service Co., Ltd. Report No.: DDT-R19022803-1E1

Revision history

Rev. Revisions Issue Date Revised By

--- Initial issue Jun. 03, 2019

Page 5 of 49
Dongguan Dongdian Testing Service Co., Ltd. Report No.: DDT-R19022803-1E1

1. Summary of test results

CLAUSE TEST PARAMETER RESULTS


(ARIB STD-T108)

3.2.1 Antenna Power PASS

3.2.2 Tolerances for Antenna Power PASS

3.2.4 Frequency Tolerance PASS

3.2.6 Permissible Value for Occupied Bandwidth PASS

3.2.7 Adjacent channel leakage power PASS


Permissible Values for Spurious Emission /
3.2.8 PASS
Unwanted Emission Intensity

3.3 Secondary Radiated Emissions PASS

3.4.1 Transmission time control equipment PASS

3.4.2 Carrier sense PASS

3.4.3 Skipping carrier sense in a response N/A

3.4.4 Interference prevention function PASS

Note: N/A= Note Application.

Page 6 of 49
Dongguan Dongdian Testing Service Co., Ltd. Report No.: DDT-R19022803-1E1

2. General test information

2.1. Description of EUT

EUT* Name : Z-Wave Smart IR Repeater


Model Number : RS-ZWIREX1
EUT function description : Please reference user manual of this device
Power supply : DC 5V
Operation frequency : 922.50MHz, 923.90MHz, 926.30MHz
Modulation : 2GFSK
Number of Channel :3
Transfer Rate : 100kbps
Communication Method : Simplex
Frequency switching method : Fixed type
Sample Type : Series production
Note: EUT is the ab. of equipment under test.

2.2. Antenna specifications

Antenna Type Gain( dBi)


Helical antenna 2.37

Antenna pattern

2D
Radiation
patterns test
results

Page 7 of 49
Dongguan Dongdian Testing Service Co., Ltd. Report No.: DDT-R19022803-1E1

3D
Radiation
patterns test
results

Page 8 of 49
Dongguan Dongdian Testing Service Co., Ltd. Report No.: DDT-R19022803-1E1

2.3. Assembly
RF and Modulation parts are mounted on PCB with surface mount technology, and there is no
any adjustable parts on PCB or adjustable parts are not exposed.

2.4. Accessories of EUT


Assistant Model Serial
Manufacturer Other
equipment number No.
Shenzhen Mingxinhui
USB cable 30130-01733 N/A Length: 1.5m, unshielded
Technology Co., LTD

2.5. Assistant equipment used for test


Assistant
Manufacturer Model number EMC Compliance SN
equipment
Notebook DELL Latitude D610 FCC DOC 00045-534-136-300

2.6. Block diagram of EUT configuration for test

EUT

Test software: PuTTY and Silabs Micro RF Link


The test software was used to control EUT work in Continuous TX mode, and select test channel,
Power Level Setting as below table.
Tested mode, channel, information
Frequency Power Level Setting
Mode Channel
(MHz)
1 922.50 63
TX mode 2 923.90 63
3 926.30 63

2.7. Test environment conditions


During the measurement the environmental conditions were within the listed ranges:

/ Normal Conditions
Temperature range 23℃
Humidity range 46%
Pressure range 100.1kPa
DC 5V
(When the input voltage to equipment fluctuated ±10%, the RF unit
Power supply
circuit voltage fluctuation under 1%, therefore all test performed on the
rated voltage for equipment.)

The measurement result of the voltage fluctuation at RF circuit when DC 5V +/- 10%.
Input voltage RF module voltage

Page 9 of 49
Dongguan Dongdian Testing Service Co., Ltd. Report No.: DDT-R19022803-1E1

DC 4.5V DC 3.30V
DC 5.0V DC 3.30V
DC 5.5V DC 3.30V

2.8. Deviations of test standard


No Deviation.

3. Test laboratory
Dongguan Dongdian Testing Service Co., Ltd
Add: No. 17, Zongbu Road 2, Songshan Lake Sci&Tech, Industry Park, Dongguan City,
Guangdong Province, China, 523808
Tel: +86-0769-38826678, http://www.dgddt.com, Email: ddt@dgddt.com
CNAS Accreditation No. L6451; A2LA Accreditation No. 3870.01
FCC Designation Number: CN1182; FCC Test Firm Registration Number: 540522
Industry Canada site registration number: 10288A-1

3.1. Measurement uncertainty

Test Item Uncertainty


Occupied Channel Bandwidth ±1%
Uncertainty for radio frequency 1×10-9
RF Output power, conducted ±0.6dB
Power Spectral Density, Conducted ±1.2dB
Unwanted Emissions, Conducted ±0.6dB
Temperature ±0.2℃
Humidity ±1%
DC and Low frequency voltage ±0.5%
Time ±1%
Duty Cycle ±1%
Note: This uncertainty represents an expanded uncertainty expressed at approximately the
95% confidence level using a coverage factor of k=2.

Page 10 of 49
Dongguan Dongdian Testing Service Co., Ltd. Report No.: DDT-R19022803-1E1

4. Equipment used during test


Cal. Calibratio
Equipment Manufacturer Model No. Serial No. Last Cal.
Interval n body
RF Connected Test (Tonscend RF Measurement System)
Spectrum
R&S FSU26 200071 Oct. 12, 2018 1 Year CEPREI
analyzer
Power Sensor Agilent U2021XA MY55150010 Oct. 21, 2018 1 Year CEPREI
Power Sensor Agilent U2021XA MY55150011 Oct. 23, 2018 1 Year CEPREI
Power Meter Agilent E4417A MY45100568 Nov. 12, 2018 1 Year CEPREI
Power Sensor Agilent E9304A MZ55040005 Oct. 12, 2018 1 Year CEPREI
DC Power
MATRIS MPS-3005L-3 D813058W Aug. 18, 2018 1 Year CEPREI
Source
Attenuator Mini-Circuits BW-S10W2 101109 Aug. 18, 2018 1 Year CEPREI
RF Cable Micable C10-01-01-1 100309 Oct. 21, 2018 1 Year CEPREI
MULTIMETER FLUKE 179 11400838 Jun. 20, 2018 1 Year CEPREI
Test Software JS Tonscend JS1120-3 Ver.2.7 N/A N/A CEPREI
Remark: Calibration conducted in countries except Japan, which shall be equivalent to the
calibration conducted by the NICT or a designated calibration agency under Article 102-18
paragraph (1).

Page 11 of 49
Dongguan Dongdian Testing Service Co., Ltd. Report No.: DDT-R19022803-1E1

5. Frequency Tolerance

5.1. Limit
It shall be within 20 X 10-6.

5.2. Block diagram of test setup

Spectrum EUT and Assistant


Attenuator
Analyzer System

5.3. Test Procedure


(1) Test Conditions: Spectrum Analyzer is used for measurement.
Centre Frequency: The centre frequency of the channel under test.
Resolution BW: 1 kHz.
Video BW: 1 kHz.
Span: 0.3 MHz.
Sweep Time: Auto
Detector mode: Positive peak
Indication mode: Max hold
(2) When the trace is complete, find the peak value of the power envelope and record the
frequency.

5.4. Test result


Result Limit
Frequency
Mode Measured Tolerance Tolerance
(MHz) ppm
(MHz) (kHz) (ppm)
922.5 922.4970 -30 -3.25 +/-20
Carrier Tx mode 923.9 923.8967 -33 -3.57 +/-20
926.3 926.2970 -30 -3.24 +/-20
Conclusion: PASS

Page 12 of 49
Dongguan Dongdian Testing Service Co., Ltd. Report No.: DDT-R19022803-1E1

5.5. Original test data


NTNV_922.5 MHz
* RBW 1 kHz Marker 1 [T1 ]
* VBW 1 kHz 2.21 dBm
Ref 30 dBm * Att 40 dB SWT 500 ms 922.497000000 MHz

30 Offset 1 dB

A
20

1 PK
VIEW
10
LVL
1

-10

-20

3DB
-30

-40

-50

-60

-70

Center 922.5 MHz 30 kHz/ Span 300 kHz

Date: 7.MAR.2019 14:54:31

NTNV_923.9 MHz
* RBW 1 kHz Marker 1 [T1 ]
* VBW 1 kHz 2.17 dBm
Ref 30 dBm * Att 40 dB SWT 500 ms 923.896700000 MHz

30 Offset 1 dB

A
20

1 PK
VIEW
10
LVL
1

-10

-20

3DB
-30

-40

-50

-60

-70

Center 923.9 MHz 30 kHz/ Span 300 kHz

Date: 7.MAR.2019 14:56:17

NTNV_926.3 MHz
* RBW 1 kHz Marker 1 [T1 ]
* VBW 1 kHz 1.87 dBm
Ref 30 dBm * Att 40 dB SWT 500 ms 926.297000000 MHz

30 Offset 1 dB

A
20

1 PK
VIEW
10
LVL
1

-10

-20

3DB
-30

-40

-50

-60

-70

Center 926.3 MHz 30 kHz/ Span 300 kHz

Date: 7.MAR.2019 14:58:09

Page 13 of 49
Dongguan Dongdian Testing Service Co., Ltd. Report No.: DDT-R19022803-1E1

6. Occupied Frequency Bandwidth

6.1. Limit
It shall be (200 x n) kHz or less. However, in the case that the center frequency is from 928.15
MHz to 929.65 MHz, it shall be (100 x n) kHz or less. (n is a number of unit channels
constituting the radio channel and is an integer from 1 to 5.)
According to ARIB STD-T108 Version 1. 2 Table 3-12 Center frequency of radio channel using
two radio channels (Antenna power: 20mW or less (with carrier sense), Bandwidth: 400 kHz),
Occupied bandwidth shall less than 400 kHz.

6.2. Block diagram of test setup

Spectrum EUT and Assistant


Attenuator
Analyzer System

6.3. Test Procedure


(1) Connected the EUT’s antenna port to the Spectrum Analyzer by suitable attenuator, set the
Spectrum Analyzer as below:
Centre Frequency: The centre frequency of the channel under test.
Span: 0.3 MHz
Resolution BW: 1 kHz
Video BW: 1 kHz
Sweep Time: Auto
Detector mode: Positive peak
Indication mode: Max hold
(4) When the trace is complete, measure the occupied bandwidth (99% bandwidth) with
spectrum analyzer’s bandwidth measure function.

6.4. Test result

Test Frequency Result Limit


Mode
(MHz) kHz kHz
2GFSK 922.5 111.000 400
2GFSK 923.9 110.700 400
2GFSK 926.3 110.100 400
Conclusion: PASS

Page 14 of 49
Dongguan Dongdian Testing Service Co., Ltd. Report No.: DDT-R19022803-1E1

6.5. Original test data


NTNV_ 2GFSK _922.5 MHz
* RBW 1 kHz Marker 1 [T1 ]
* VBW 1 kHz -6.35 dBm
Ref 20 dBm * Att 20 dB SWT 500 ms 922.500900000 MHz

20 Offset 1 dB OBW111.000000000 kHz


Temp 1 [T1 OBW]
-21.30 dBm A
10
922.440900000 MHz
1 PK Temp 2 [T1 OBW]
VIEW
0 -22.24 dBm
LVL
1 922.551900000 MHz

-10

T1 T2
-20

-30

3DB
-40

-50

-60

-70

-80

Center 922.5 MHz 30 kHz/ Span 300 kHz

Date: 7.MAR.2019 09:19:41

NTNV_ 2GFSK _923.9 MHz


* RBW 1 kHz Marker 1 [T1 ]
* VBW 1 kHz -6.22 dBm
Ref 20 dBm * Att 20 dB SWT 500 ms 923.884100000 MHz

20 Offset 1 dB OBW110.700000000 kHz


Temp 1 [T1 OBW]
-18.18 dBm A
10
923.841500000 MHz
1 PK Temp 2 [T1 OBW]
VIEW
0 -20.53 dBm
LVL
1 923.952200000 MHz

-10

T1
T2
-20

-30

3DB
-40

-50

-60

-70

-80

Center 923.9 MHz 30 kHz/ Span 300 kHz

Date: 7.MAR.2019 09:29:53

NTNV_ 2GFSK _926.3 MHz


* RBW 1 kHz Marker 1 [T1 ]
* VBW 1 kHz -6.30 dBm
Ref 20 dBm * Att 20 dB SWT 500 ms 926.304500000 MHz

20 Offset 1 dB OBW110.100000000 kHz


Temp 1 [T1 OBW]
-18.94 dBm A
10
926.240900000 MHz
1 PK Temp 2 [T1 OBW]
VIEW
0 -21.75 dBm
LVL
1 926.351000000 MHz

-10

T1
T2
-20

-30

3DB
-40

-50

-60

-70

-80

Center 926.3 MHz 30 kHz/ Span 300 kHz

Date: 7.MAR.2019 09:37:51

Page 15 of 49
Dongguan Dongdian Testing Service Co., Ltd. Report No.: DDT-R19022803-1E1

7. Antenna Power and Tolerances for Antenna Power

7.1. Limit
Limit 20 mW
Tolerance +20%, -80%

7.2. Block diagram of test setup

Power Meter EUT

7.3. Test Procedure


(1) Connected the EUT’s antenna port to the Power Meter.
(2) The cable loss and attenuator loss have been put into the result.

7.4. Test result


Stated
Frequency Measured Tolerances Limit
Mode power
MHz
dBm mW % (mW) mW
922.5 4.53 2.84 -5.40 3 20
2GFSK
923.9 4.65 2.92 -2.75 3 20
Tx mode
926.3 4.55 2.85 -4.97 3 20
Tolerances for Antenna Power Limit: +20%, -80%
Conclusion: PASS

NTNV_ 2GFSK _922.5 MHz

NTNV_ 2GFSK _923.9 MHz

Page 16 of 49
Dongguan Dongdian Testing Service Co., Ltd. Report No.: DDT-R19022803-1E1

NTNV_ 2GFSK _926.3 MHz

Page 17 of 49
Dongguan Dongdian Testing Service Co., Ltd. Report No.: DDT-R19022803-1E1

8. Adjacent channel leakage power

8.1. Limit
Frequency band of signal in use is from 922.3MHz to 928.1MHz. (Antenna power is 20mW or
less (with carrier sense).)
Leakage power in unit channel adjacent to a radio channel: It shall be –15dBm or less.

8.2. Block diagram of test setup

Spectrum EUT and Assistant


Attenuator
Analyzer System

8.3. Test Procedure


(1) Connected the EUT’s antenna port to the Spectrum Analyzer by suitable attenuator, set the
Spectrum Analyzer as below:
Centre Frequency: The centre frequency of the channel under test.
Resolution BW: 1 kHz.
Video BW: 3 kHz.
Span: 800 kHz.
Detector: Peak.
Trace Mode: Max Hold.
(2) When the trace is complete, search the frequency of peak power
Note: The cable loss and attenuator loss have been put into spectrum analyzer as amplitude
offset.

Page 18 of 49
Dongguan Dongdian Testing Service Co., Ltd. Report No.: DDT-R19022803-1E1

8.4. Test result


Channel Adjacent Measured Limit
Mode
unit channel dBm dBm
Lower adjacent
-36.27 -15
CH1 unit channel
(922.5 MHz) Upper adjacent
-37.64 -15
unit channel
Lower adjacent -15
-34.55
2GFSK CH2 unit channel
Tx mode (923.9 MHz) Upper adjacent -15
-37.93
unit channel
Lower adjacent -15
-34.21
CH3 unit channel
(926.3 MHz) Upper adjacent -15
-36.70
unit channel
Tolerances for Antenna Power Limit: +20%, -80%
Conclusion: PASS

TNVN_2GFSK _922.5 MHz


* RBW 1 kHz
* VBW 3 kHz
Ref 10 dBm * Att 10 dB SWT 800 ms

Offset 1 dB
0

-10 A

-20
1 RM *
VIEW -30
LVL
-40

-50

-60

-70

-80 3DB

Center 922.5 MHz 80 kHz/ Span 800 kHz

Tx Channel
Bandwidth 200 kHz
Power 5.58 dBm
Adjacent Channel
Bandwidth 200 kHz Lower -36.27 dB
Spacing 200 kHz
Upper -37.64 dB

Date: 7.MAR.2019 16:10:20

TNVN_2GFSK _923.9 MHz


* RBW 1 kHz
* VBW 3 kHz
Ref 10 dBm * Att 10 dB SWT 800 ms

Offset 1 dB
0

-10 A

-20
1 RM *
VIEW -30
LVL
-40

-50

-60

-70

-80 3DB

Center 923.9 MHz 80 kHz/ Span 800 kHz

Tx Channel
Bandwidth 200 kHz
Power 5.75 dBm
Adjacent Channel
Bandwidth 200 kHz Lower -34.55 dB
Spacing 200 kHz
Upper -37.93 dB

Date: 7.MAR.2019 16:06:26

Page 19 of 49
Dongguan Dongdian Testing Service Co., Ltd. Report No.: DDT-R19022803-1E1

TNVN_2GFSK _926.3 MHz


* RBW 1 kHz
* VBW 3 kHz
Ref 10 dBm * Att 10 dB SWT 800 ms

Offset 1 dB
0

-10 A

-20
1 RM *
VIEW -30
LVL
-40

-50

-60

-70

-80 3DB

Center 926.3 MHz 80 kHz/ Span 800 kHz

Tx Channel
Bandwidth 200 kHz
Power 4.55 dBm
Adjacent Channel
Bandwidth 200 kHz Lower -34.21 dB
Spacing 200 kHz
Upper -36.70 dB

Date: 7.MAR.2019 16:12:43

Page 20 of 49
Dongguan Dongdian Testing Service Co., Ltd. Report No.: DDT-R19022803-1E1

9. Transmitter Spurious Emissions

9.1. Limit
Table 3-16 Permissible Values for Spurious Emission / Unwanted Emission Intensity (Antenna
input)
Spurious emission /
Unwanted Emission
Frequency band Reference bandwidth
Intensity(average
power)
f <= 710 MHz -36 dBm 100 kHz
710 MHz < f <= 900 MHz -55 dBm 1 MHz
900 MHz < f <= 915 MHz -55 dBm 100 kHz
915 MHz < f <= 930 MHz
(Except for |f-fc| <= (200+100×n) kHz
if bandwidth of unit channel is 200 kHz,
except for |f-fc| <= (100+50×n) kHz if
bandwidth of unit channel is 100 kHz.
Except for |f-fc| <= (100+100×n) kHz
-36 dBm 100 kHz
If frequency band is
915.9MHz <= f <=916.9MHz and
920.5MHz <= 922.3MHz.
Where n is a number of unit channels
constituting the radio channel and is an
integer from 1 to 5)
930 MHz < f <= 1000 MHz -55 dBm 100 kHz
1000MHz < f <= 1,215 MHz -45 dBm 1 MHz
1,215 MHz < f -30 dBm 1 MHz

9.2. Block diagram of test setup

Spectrum EUT and Assistant


Attenuator
Analyzer System

9.3. Test Procedure


(1) Connected the EUT’s antenna port to the Spectrum Analyzer by suitable attenuator, set the
Spectrum Analyzer as below:
Detector: Peak.
Trace Mode: Max Hold.
(2) When the trace is complete, search the frequency of peak power
(3) All the emissions from 30MHz to 5GHz were measured and record.

Page 21 of 49
Dongguan Dongdian Testing Service Co., Ltd. Report No.: DDT-R19022803-1E1

9.4. Test result


Test Test Channel Result Limit
Freq. Range Freq.[MHz] Verdict
Condition Mode Freq.[MHz] [dBm] [dBm]
NTNV 2GFSK 922.5 30~710 MHz 548.16 -55.27 -36 PASS
NTNV 2GFSK 922.5 710~900 MHz 854.21 -67.57 -55 PASS
NTNV 2GFSK 922.5 900~915 MHz 911.45 -63.88 -55 PASS
NTNV 2GFSK 922.5 915~920.3 MHz 917.05 -48.35 -36 PASS
920.3~|f-fc| <=
NTNV 2GFSK 922.5 922.19 -42.83 -36 PASS
(200+100×n) kHz
|f-fc| <= (200+100×n)
NTNV 2GFSK 922.5 922.80 -43.69 -36 PASS
kHz~930
NTNV 2GFSK 922.5 930~1000 MHz 933.43 -57.93 -55 PASS
NTNV 2GFSK 922.5 1000~1215 MHz 1020.55 -67.26 -45 PASS
NTNV 2GFSK 922.5 1215~5000 MHz 2767.61 -38.60 -30 PASS
NTNV 2GFSK 923.9 30~710 MHz 391.08 -56.08 -36 PASS
NTNV 2GFSK 923.9 710~900 MHz 861.43 -67.94 -55 PASS
NTNV 2GFSK 923.9 900~915 MHz 911.75 -64.48 -55 PASS
NTNV 2GFSK 923.9 915~920.3 MHz 919.86 -48.63 -36 PASS
920.3~|f-fc| <=
NTNV 2GFSK 923.9 923.59 -43.10 -36 PASS
(200+100×n) kHz
|f-fc| <= (200+100×n)
NTNV 2GFSK 923.9 924.20 -42.08 -36 PASS
kHz~930
NTNV 2GFSK 923.9 930~1000 MHz 932.03 -59.77 -55 PASS
NTNV 2GFSK 923.9 1000~1215 MHz 1160.05 -67.46 -45 PASS
NTNV 2GFSK 923.9 1215~5000 MHz 2771.77 -38.00 -30 PASS
NTNV 2GFSK 926.3 30~710 MHz 605.28 -55.37 -36 PASS
NTNV 2GFSK 926.3 710~900 MHz 783.34 -68.22 -55 PASS
NTNV 2GFSK 926.3 900~915 MHz 914.67 -64.83 -55 PASS
NTNV 2GFSK 926.3 915~920.3 MHz 919.86 -48.63 -36 PASS
920.3~|f-fc| <=
NTNV 2GFSK 926.3 924.64 -40.32 -36 PASS
(200+100×n) kHz
|f-fc| <= (200+100×n)
NTNV 2GFSK 926.3 928.00 -39.75 -36 PASS
kHz~930
NTNV 2GFSK 926.3 930~1000 MHz 931.47 -57.96 -55 PASS
NTNV 2GFSK 926.3 1000~1215 MHz 1194.73 -67.12 -45 PASS
NTNV 2GFSK 926.3 1215~5000 MHz 2778.96 -41.42 -30 PASS

Page 22 of 49
Dongguan Dongdian Testing Service Co., Ltd. Report No.: DDT-R19022803-1E1

9.5. Original test data


NTNV_2GFSK _922.5_30~710
* RBW 100 kHz Marker 1 [T1 ]
* VBW 100 kHz -55.27 dBm
Ref 20 dBm * Att 20 dB SWT 70 ms 548.160000000 MHz

20 Offset 1 dB

A
10

1 PK
MAXH
0
LVL

-10

-20

-30

D1 -36 dBm 3DB


-40

-50
1

-60

-70

-80

Start 30 MHz 68 MHz/ Stop 710 MHz

Date: 7.MAR.2019 09:21:40

NTNV_2GFSK _922.5_710~900
* RBW 1 MHz Marker 1 [T1 ]
* VBW 1 MHz -67.57 dBm
Ref 10 dBm * Att 10 dB SWT 5 ms 854.210000000 MHz

10 Offset 1 dB

A
0

1 PK
MAXH
-10
LVL

-20

-30

-40

3DB
-50

D1 -55 dBm

-60

-70

-80

-90

Start 710 MHz 19 MHz/ Stop 900 MHz

Date: 7.MAR.2019 09:21:51

NTNV_2GFSK _922.5_900~915
* RBW 100 kHz Marker 1 [T1 ]
* VBW 100 kHz -63.88 dBm
Ref 10 dBm * Att 10 dB SWT 10 ms 911.445000000 MHz

10 Offset 1 dB

A
0

1 PK
MAXH
-10
LVL

-20

-30

-40

3DB
-50

D1 -55 dBm

-60 1

-70

-80

-90

Start 900 MHz 1.5 MHz/ Stop 915 MHz

Date: 7.MAR.2019 09:22:02

Page 23 of 49
Dongguan Dongdian Testing Service Co., Ltd. Report No.: DDT-R19022803-1E1

NTNV_2GFSK _922.5_915~920.3
* RBW 100 kHz Marker 1 [T1 ]
* VBW 100 kHz -48.35 dBm
Ref 10 dBm * Att 10 dB SWT 5 ms 917.045800000 MHz

10 Offset 1 dB

A
0

1 PK
MAXH
-10
LVL

-20

-30

D1 -36 dBm
-40

1
3DB
-50

-60

-70

-80

-90

Start 915 MHz 530 kHz/ Stop 920.3 MHz

Date: 7.MAR.2019 09:22:17

NTNV_2GFSK _922.5_920.3~922.2
* RBW 100 kHz Marker 1 [T1 ]
* VBW 100 kHz -42.83 dBm
Ref 10 dBm * Att 10 dB SWT 45 ms 922.193920000 MHz

10 Offset 1 dB

A
0

1 PK
MAXH
-10
LVL

-20

-30

D1 -36 dBm
-40 1

3DB
-50

-60

-70

-80

-90

Start 920.3 MHz 190 kHz/ Stop 922.2 MHz

Date: 7.MAR.2019 09:22:28

NTNV_2GFSK _922.5_922.8~930
* RBW 100 kHz Marker 1 [T1 ]
* VBW 100 kHz -43.69 dBm
Ref 10 dBm * Att 10 dB SWT 5 ms 922.800000000 MHz

10 Offset 1 dB

A
0

1 PK
MAXH
-10
LVL

-20

-30

D1 -36 dBm

1 -40

3DB
-50

-60

-70

-80

-90

Start 922.8 MHz 720 kHz/ Stop 930 MHz

Date: 7.MAR.2019 09:22:39

NTNV_2GFSK _922.5_930~1000

Page 24 of 49
Dongguan Dongdian Testing Service Co., Ltd. Report No.: DDT-R19022803-1E1

* RBW 100 kHz Marker 1 [T1 ]


* VBW 100 kHz -57.93 dBm
Ref 10 dBm * Att 10 dB SWT 10 ms 933.430000000 MHz

10 Offset 1 dB

A
0

1 PK
MAXH
-10
LVL

-20

-30

-40

3DB
-50

1 D1 -55 dBm

-60

-70

-80

-90

Start 930 MHz 7 MHz/ Stop 1 GHz

Date: 7.MAR.2019 09:22:54

NTNV_2GFSK _922.5_1000~1215
* RBW 1 MHz Marker 1 [T1 ]
* VBW 1 MHz -67.26 dBm
Ref 10 dBm * Att 10 dB SWT 45 ms 1.022553500 GHz

10 Offset 1 dB

A
0

1 PK
MAXH
-10
LVL

-20

-30

-40

D1 -45 dBm
3DB
-50

-60
1

-70

-80

-90

Start 1 GHz 21.5 MHz/ Stop 1.215 GHz

Date: 7.MAR.2019 09:23:05

NTNV_2GFSK _922.5_1215~5000
* RBW 1 MHz Marker 1 [T1 ]
* VBW 1 MHz -38.60 dBm
Ref 10 dBm * Att 10 dB SWT 45 ms 2.767607000 GHz

10 Offset 1 dB

A
0

1 PK
VIEW
-10
LVL

-20

-30 D1 -30 dBm

-40

3DB
-50

-60

-70

-80

-90

Start 1.215 GHz 378.5 MHz/ Stop 5 GHz

Date: 7.MAR.2019 09:23:24

Page 25 of 49
Dongguan Dongdian Testing Service Co., Ltd. Report No.: DDT-R19022803-1E1

NTNV_2GFSK _923.9_30~710
* RBW 100 kHz Marker 1 [T1 ]
* VBW 100 kHz -56.08 dBm
Ref 20 dBm * Att 20 dB SWT 70 ms 391.080000000 MHz

20 Offset 1 dB

A
10

1 PK
MAXH
0
LVL

-10

-20

-30

D1 -36 dBm 3DB


-40

-50
1

-60

-70

-80

Start 30 MHz 68 MHz/ Stop 710 MHz

Date: 7.MAR.2019 09:30:17

NTNV_2GFSK _922.5_710~900
* RBW 1 MHz Marker 1 [T1 ]
* VBW 1 MHz -67.94 dBm
Ref 10 dBm * Att 10 dB SWT 5 ms 861.430000000 MHz

10 Offset 1 dB

A
0

1 PK
MAXH
-10
LVL

-20

-30

-40

3DB
-50

D1 -55 dBm

-60

-70

-80

-90

Start 710 MHz 19 MHz/ Stop 900 MHz

Date: 7.MAR.2019 09:30:28

NTNV_2GFSK _923.9_900~915
* RBW 100 kHz Marker 1 [T1 ]
* VBW 100 kHz -64.48 dBm
Ref 10 dBm * Att 10 dB SWT 10 ms 911.745000000 MHz

10 Offset 1 dB

A
0

1 PK
MAXH
-10
LVL

-20

-30

-40

3DB
-50

D1 -55 dBm

-60
1

-70

-80

-90

Start 900 MHz 1.5 MHz/ Stop 915 MHz

Date: 7.MAR.2019 09:30:38

NTNV_2GFSK _923.9_915~920.3

Page 26 of 49
Dongguan Dongdian Testing Service Co., Ltd. Report No.: DDT-R19022803-1E1

* RBW 100 kHz Marker 1 [T1 ]


* VBW 100 kHz -48.63 dBm
Ref 10 dBm * Att 10 dB SWT 5 ms 919.860100000 MHz

10 Offset 1 dB

A
0

1 PK
MAXH
-10
LVL

-20

-30

D1 -36 dBm
-40

1 3DB
-50

-60

-70

-80

-90

Start 915 MHz 530 kHz/ Stop 920.3 MHz

Date: 7.MAR.2019 09:30:54

NTNV_2GFSK _923.9_920.3~923.6
* RBW 100 kHz Marker 1 [T1 ]
* VBW 100 kHz -43.10 dBm
Ref 10 dBm * Att 10 dB SWT 45 ms 923.589110000 MHz

10 Offset 1 dB

A
0

1 PK
MAXH
-10
LVL

-20

-30

D1 -36 dBm
-40 1

3DB
-50

-60

-70

-80

-90

Start 920.3 MHz 330 kHz/ Stop 923.6 MHz

Date: 7.MAR.2019 09:31:05

NTNV_2GFSK _923.9_924.2~930
* RBW 100 kHz Marker 1 [T1 ]
* VBW 100 kHz -42.08 dBm
Ref 10 dBm * Att 10 dB SWT 5 ms 924.200000000 MHz

10 Offset 1 dB

A
0

1 PK
MAXH
-10
LVL

-20

-30

D1 -36 dBm
1
-40

3DB
-50

-60

-70

-80

-90

Start 924.2 MHz 580 kHz/ Stop 930 MHz

Date: 7.MAR.2019 09:31:16

NTNV_2GFSK _923.9_930~1000

Page 27 of 49
Dongguan Dongdian Testing Service Co., Ltd. Report No.: DDT-R19022803-1E1

* RBW 100 kHz Marker 1 [T1 ]


* VBW 100 kHz -59.77 dBm
Ref 10 dBm * Att 10 dB SWT 10 ms 932.030000000 MHz

10 Offset 1 dB

A
0

1 PK
MAXH
-10
LVL

-20

-30

-40

3DB
-50

D1 -55 dBm
1
-60

-70

-80

-90

Start 930 MHz 7 MHz/ Stop 1 GHz

Date: 7.MAR.2019 09:31:31

NTNV_2GFSK _923.9_1000~1215
* RBW 1 MHz Marker 1 [T1 ]
* VBW 1 MHz -67.46 dBm
Ref 10 dBm * Att 10 dB SWT 45 ms 1.160046000 GHz

10 Offset 1 dB

A
0

1 PK
MAXH
-10
LVL

-20

-30

-40

D1 -45 dBm
3DB
-50

-60

-70

-80

-90

Start 1 GHz 21.5 MHz/ Stop 1.215 GHz

Date: 7.MAR.2019 09:31:42

NTNV_2GFSK _923.9_1215~5000
* RBW 1 MHz Marker 1 [T1 ]
* VBW 1 MHz -38.00 dBm
Ref 10 dBm * Att 10 dB SWT 45 ms 2.771770500 GHz

10 Offset 1 dB

A
0

1 PK
VIEW
-10
LVL

-20

-30 D1 -30 dBm

-40

3DB
-50

-60

-70

-80

-90

Start 1.215 GHz 378.5 MHz/ Stop 5 GHz

Date: 7.MAR.2019 09:32:02

Page 28 of 49
Dongguan Dongdian Testing Service Co., Ltd. Report No.: DDT-R19022803-1E1

NTNV_2GFSK _926.3_30~710
* RBW 100 kHz Marker 1 [T1 ]
* VBW 100 kHz -55.37 dBm
Ref 20 dBm * Att 20 dB SWT 70 ms 605.280000000 MHz

20 Offset 1 dB

A
10

1 PK
MAXH
0
LVL

-10

-20

-30

D1 -36 dBm 3DB


-40

-50
1

-60

-70

-80

Start 30 MHz 68 MHz/ Stop 710 MHz

Date: 7.MAR.2019 13:48:50

NTNV_2GFSK _926.3_710~900
* RBW 1 MHz Marker 1 [T1 ]
* VBW 1 MHz -68.22 dBm
Ref 10 dBm * Att 10 dB SWT 5 ms 783.340000000 MHz

10 Offset 1 dB

A
0

1 PK
MAXH
-10
LVL

-20

-30

-40

3DB
-50

D1 -55 dBm

-60

-70

-80

-90

Start 710 MHz 19 MHz/ Stop 900 MHz

Date: 7.MAR.2019 13:49:00

NTNV_2GFSK _926.3_900~915
* RBW 100 kHz Marker 1 [T1 ]
* VBW 100 kHz -64.83 dBm
Ref 10 dBm * Att 10 dB SWT 10 ms 914.670000000 MHz

10 Offset 1 dB

A
0

1 PK
MAXH
-10
LVL

-20

-30

-40

3DB
-50

D1 -55 dBm

-60
1

-70

-80

-90

Start 900 MHz 1.5 MHz/ Stop 915 MHz

Date: 7.MAR.2019 13:49:11

NTNV_2GFSK _926.3_915~920.3

Page 29 of 49
Dongguan Dongdian Testing Service Co., Ltd. Report No.: DDT-R19022803-1E1

* RBW 100 kHz Marker 1 [T1 ]


* VBW 100 kHz -48.63 dBm
Ref 10 dBm * Att 10 dB SWT 5 ms 919.860100000 MHz

10 Offset 1 dB

A
0

1 PK
MAXH
-10
LVL

-20

-30

D1 -36 dBm
-40

1 3DB
-50

-60

-70

-80

-90

Start 915 MHz 530 kHz/ Stop 920.3 MHz

Date: 7.MAR.2019 09:30:54

NTNV_2GFSK _926.3_920.3~926
* RBW 100 kHz Marker 1 [T1 ]
* VBW 100 kHz -40.32 dBm
Ref 10 dBm * Att 10 dB SWT 45 ms 924.640550000 MHz

10 Offset 1 dB

A
0

1 PK
MAXH
-10
LVL

-20

-30

D1 -36 dBm 1
-40

3DB
-50

-60

-70

-80

-90

Start 920.3 MHz 570 kHz/ Stop 926 MHz

Date: 7.MAR.2019 13:49:38

NTNV_2GFSK _926.3_926.6~930
* RBW 100 kHz Marker 1 [T1 ]
* VBW 100 kHz -39.75 dBm
Ref 10 dBm * Att 10 dB SWT 5 ms 927.997400000 MHz

10 Offset 1 dB

A
0

1 PK
MAXH
-10
LVL

-20

-30

D1 -36 dBm 1
-40

3DB
-50

-60

-70

-80

-90

Start 926.6 MHz 340 kHz/ Stop 930 MHz

Date: 7.MAR.2019 13:49:48

NTNV_2GFSK _926.3_930~1000

Page 30 of 49
Dongguan Dongdian Testing Service Co., Ltd. Report No.: DDT-R19022803-1E1

* RBW 100 kHz Marker 1 [T1 ]


* VBW 100 kHz -57.96 dBm
Ref 10 dBm * Att 10 dB SWT 10 ms 931.470000000 MHz

10 Offset 1 dB

A
0

1 PK
MAXH
-10
LVL

-20

-30

-40

3DB
-50

1 D1 -55 dBm

-60

-70

-80

-90

Start 930 MHz 7 MHz/ Stop 1 GHz

Date: 7.MAR.2019 13:50:04

NTNV_2GFSK _926.3_1000~1215
* RBW 1 MHz Marker 1 [T1 ]
* VBW 1 MHz -67.12 dBm
Ref 10 dBm * Att 10 dB SWT 45 ms 1.194725500 GHz

10 Offset 1 dB

A
0

1 PK
MAXH
-10
LVL

-20

-30

-40

D1 -45 dBm
3DB
-50

-60
1

-70

-80

-90

Start 1 GHz 21.5 MHz/ Stop 1.215 GHz

Date: 7.MAR.2019 13:50:15

NTNV_2GFSK _926.3_1215~5000
* RBW 1 MHz Marker 1 [T1 ]
* VBW 1 MHz -41.42 dBm
Ref 10 dBm * Att 10 dB SWT 45 ms 2.778962000 GHz

10 Offset 1 dB

A
0

1 PK
VIEW
-10
LVL

-20

-30 D1 -30 dBm

1
-40

3DB
-50

-60

-70

-80

-90

Start 1.215 GHz 378.5 MHz/ Stop 5 GHz

Date: 7.MAR.2019 13:50:47

Page 31 of 49
Dongguan Dongdian Testing Service Co., Ltd. Report No.: DDT-R19022803-1E1

10. Secondary Radiated Emissions

10.1. Limit
Table 3-16 Permissible Values for Spurious Emission / Unwanted Emission Intensity (Antenna
input)
Limit on Secondary
Frequency band Radiated Emissions Reference bandwidth
(Antenna input)
f <= 710 MHz -54 dBm 100 kHz
710 MHz < f <= 900 MHz -55 dBm 1 MHz
900 MHz < f <= 915 MHz -55 dBm 100 kHz
915 MHz < f <= 930 MHz -54 dBm 100 kHz
930 MHz < f <= 1000 MHz -55 dBm 100 kHz
1000MHz < f -47 dBm 1 MHz

10.2. Block diagram of test setup

Spectrum EUT and Assistant


Attenuator
Analyzer System

10.3. Test Procedure


(1) (1) Connected the EUT’s antenna port to the Spectrum Analyzer by suitable attenuator, set
the Spectrum Analyzer as below:
Detector: Peak.
Trace Mode: Max Hold.
(2) When the trace is complete, search the frequency of peak power
(3) All the emissions from 30MHz to 5GHz were measured and record.

10.4. Test result


Test Channel Freq. Range Freq. Result Limit
Antenna Verdict
Condition Freq.[MHz] [MHz] [MHz] (dBm) (dBm)
NTNV ANT1 922.5 30.0~710.0 124.01 -76.51 -54 PASS
NTNV ANT1 922.5 710.0~900.0 728.35 -78.93 -55 PASS
NTNV ANT1 922.5 900.0~915.0 912.09 -76.68 -55 PASS
NTNV ANT1 922.5 915.0~930.0 925.57 -76.98 -54 PASS
NTNV ANT1 922.5 930.0~1000 931.94 -76.10 -55 PASS
NTNV ANT1 922.5 1000~5000 2844.60 -77.78 -47 PASS
NTNV ANT1 923.9 30.0~710.0 62.22 -76.22 -54 PASS
NTNV ANT1 923.9 710.0~900.0 807.02 -78.11 -55 PASS

Page 32 of 49
Dongguan Dongdian Testing Service Co., Ltd. Report No.: DDT-R19022803-1E1

NTNV ANT1 923.9 900.0~915.0 911.00 -77.26 -55 PASS


NTNV ANT1 923.9 915.0~930.0 926.97 -77.06 -54 PASS
NTNV ANT1 923.9 930.0~1000 963.83 -76.15 -55 PASS
NTNV ANT1 923.9 1000~5000 2655.60 -77.50 -47 PASS
NTNV ANT1 926.3 30.0~710.0 208.93 -75.73 -54 PASS
NTNV ANT1 926.3 710.0~900.0 750.99 -78.74 -55 PASS
NTNV ANT1 926.3 900.0~915.0 909.41 -76.67 -55 PASS
NTNV ANT1 926.3 915.0~930.0 915.91 -76.17 -54 PASS
NTNV ANT1 926.3 930.0~1000 988.14 -77.01 -55 PASS
NTNV ANT1 926.3 1000~5000 2608.80 -77.98 -47 PASS

Page 33 of 49
Dongguan Dongdian Testing Service Co., Ltd. Report No.: DDT-R19022803-1E1

10.5. Original test data


NTNV_2GFSK _922.5_30~710
* RBW 100 kHz Marker 1 [T1 ]
* VBW 100 kHz -76.51 dBm
Ref 0 dBm * Att 0 dB SWT 70 ms 124.010000000 MHz

0 Offset 1 dB

A
-10

1 PK
MAXH
-20
LVL

-30

-40

-50
D1 -54 dBm
3DB
-60

-70
1

-80

-90

-100

Start 30 MHz 68 MHz/ Stop 710 MHz

Date: 7.MAR.2019 14:36:45

NTNV_2GFSK _922.5_710~900
* RBW 1 MHz Marker 1 [T1 ]
* VBW 1 MHz -78.93 dBm
Ref 0 dBm * Att 0 dB SWT 85 ms 728.354000000 MHz

0 Offset 1 dB

A
-10

1 PK
MAXH
-20
LVL

-30

-40

-50

D1 -55 dBm
3DB
-60

-70

-80

-90

-100

Start 710 MHz 19 MHz/ Stop 900 MHz

Date: 7.MAR.2019 14:36:54

NTNV_2GFSK _922.5_900~915
* RBW 100 kHz Marker 1 [T1 ]
* VBW 100 kHz -76.68 dBm
Ref 0 dBm * Att 0 dB SWT 35 ms 912.088125000 MHz

0 Offset 1 dB

A
-10

1 PK
MAXH
-20
LVL

-30

-40

-50

D1 -55 dBm
3DB
-60

-70
1

-80

-90

-100

Start 900 MHz 1.5 MHz/ Stop 915 MHz

Date: 7.MAR.2019 14:37:03

NTNV_2GFSK _922.5_915~930

Page 34 of 49
Dongguan Dongdian Testing Service Co., Ltd. Report No.: DDT-R19022803-1E1

* RBW 100 kHz Marker 1 [T1 ]


* VBW 100 kHz -76.98 dBm
Ref 0 dBm * Att 0 dB SWT 85 ms 925.567500000 MHz

0 Offset 1 dB

A
-10

1 PK
MAXH
-20
LVL

-30

-40

-50
D1 -54 dBm
3DB
-60

-70
1

-80

-90

-100

Start 915 MHz 1.5 MHz/ Stop 930 MHz

Date: 7.MAR.2019 14:37:12

NTNV_2GFSK _922.5_930~1000
* RBW 100 kHz Marker 1 [T1 ]
* VBW 100 kHz -76.10 dBm
Ref 0 dBm * Att 0 dB SWT 35 ms 931.942500000 MHz

0 Offset 1 dB

A
-10

1 PK
MAXH
-20
LVL

-30

-40

-50

D1 -55 dBm
3DB
-60

-70
1

-80

-90

-100

Start 930 MHz 7 MHz/ Stop 1 GHz

Date: 7.MAR.2019 14:37:21

NTNV_2GFSK _922.5_1000~5000
* RBW 1 MHz Marker 1 [T1 ]
* VBW 1 MHz -77.78 dBm
Ref 0 dBm * Att 0 dB SWT 85 ms 2.844600000 GHz

0 Offset 1 dB

A
-10

1 PK
VIEW
-20
LVL

-30

-40

D1 -47 dBm
-50

3DB
-60

-70

-80

-90

-100

Start 1 GHz 400 MHz/ Stop 5 GHz

Date: 7.MAR.2019 14:37:48

Page 35 of 49
Dongguan Dongdian Testing Service Co., Ltd. Report No.: DDT-R19022803-1E1

NTNV_2GFSK _923.9_30~710
* RBW 100 kHz Marker 1 [T1 ]
* VBW 100 kHz -76.22 dBm
Ref 0 dBm * Att 0 dB SWT 70 ms 62.215000000 MHz

0 Offset 1 dB

A
-10

1 PK
MAXH
-20
LVL

-30

-40

-50
D1 -54 dBm
3DB
-60

-70
1

-80

-90

-100

Start 30 MHz 68 MHz/ Stop 710 MHz

Date: 7.MAR.2019 14:41:32

NTNV_2GFSK _923.9_710~900
* RBW 1 MHz Marker 1 [T1 ]
* VBW 1 MHz -78.11 dBm
Ref 0 dBm * Att 0 dB SWT 85 ms 807.023500000 MHz

0 Offset 1 dB

A
-10

1 PK
MAXH
-20
LVL

-30

-40

-50

D1 -55 dBm
3DB
-60

-70

-80

-90

-100

Start 710 MHz 19 MHz/ Stop 900 MHz

Date: 7.MAR.2019 14:41:41

NTNV_2GFSK _923.9_900~915
* RBW 100 kHz Marker 1 [T1 ]
* VBW 100 kHz -77.26 dBm
Ref 0 dBm * Att 0 dB SWT 35 ms 911.000625000 MHz

0 Offset 1 dB

A
-10

1 PK
MAXH
-20
LVL

-30

-40

-50

D1 -55 dBm
3DB
-60

-70
1

-80

-90

-100

Start 900 MHz 1.5 MHz/ Stop 915 MHz

Date: 7.MAR.2019 14:41:50

NTNV_2GFSK _923.9_915~930

Page 36 of 49
Dongguan Dongdian Testing Service Co., Ltd. Report No.: DDT-R19022803-1E1

* RBW 100 kHz Marker 1 [T1 ]


* VBW 100 kHz -77.06 dBm
Ref 0 dBm * Att 0 dB SWT 85 ms 926.967750000 MHz

0 Offset 1 dB

A
-10

1 PK
MAXH
-20
LVL

-30

-40

-50
D1 -54 dBm
3DB
-60

-70
1

-80

-90

-100

Start 915 MHz 1.5 MHz/ Stop 930 MHz

Date: 7.MAR.2019 14:41:59

NTNV_2GFSK _923.9_930~1000
* RBW 100 kHz Marker 1 [T1 ]
* VBW 100 kHz -76.15 dBm
Ref 0 dBm * Att 0 dB SWT 35 ms 963.845000000 MHz

0 Offset 1 dB

A
-10

1 PK
MAXH
-20
LVL

-30

-40

-50

D1 -55 dBm
3DB
-60

-70
1

-80

-90

-100

Start 930 MHz 7 MHz/ Stop 1 GHz

Date: 7.MAR.2019 14:42:08

NTNV_2GFSK _923.9_1000~5000
* RBW 1 MHz Marker 1 [T1 ]
* VBW 1 MHz -77.50 dBm
Ref 0 dBm * Att 0 dB SWT 85 ms 2.655600000 GHz

0 Offset 1 dB

A
-10

1 PK
VIEW
-20
LVL

-30

-40

D1 -47 dBm
-50

3DB
-60

-70

-80

-90

-100

Start 1 GHz 400 MHz/ Stop 5 GHz

Date: 7.MAR.2019 14:43:09

Page 37 of 49
Dongguan Dongdian Testing Service Co., Ltd. Report No.: DDT-R19022803-1E1

NTNV_2GFSK _926.3_30~710
* RBW 100 kHz Marker 1 [T1 ]
* VBW 100 kHz -75.73 dBm
Ref 0 dBm * Att 0 dB SWT 70 ms 208.925000000 MHz

0 Offset 1 dB

A
-10

1 PK
MAXH
-20
LVL

-30

-40

-50
D1 -54 dBm
3DB
-60

-70
1

-80

-90

-100

Start 30 MHz 68 MHz/ Stop 710 MHz

Date: 7.MAR.2019 14:46:15

NTNV_2GFSK _926.3_710~900
* RBW 1 MHz Marker 1 [T1 ]
* VBW 1 MHz -78.74 dBm
Ref 0 dBm * Att 0 dB SWT 85 ms 750.992500000 MHz

0 Offset 1 dB

A
-10

1 PK
MAXH
-20
LVL

-30

-40

-50

D1 -55 dBm
3DB
-60

-70

-80

-90

-100

Start 710 MHz 19 MHz/ Stop 900 MHz

Date: 7.MAR.2019 14:46:24

NTNV_2GFSK _926.3_900~915
* RBW 100 kHz Marker 1 [T1 ]
* VBW 100 kHz -76.67 dBm
Ref 0 dBm * Att 0 dB SWT 35 ms 909.414375000 MHz

0 Offset 1 dB

A
-10

1 PK
MAXH
-20
LVL

-30

-40

-50

D1 -55 dBm
3DB
-60

-70
1

-80

-90

-100

Start 900 MHz 1.5 MHz/ Stop 915 MHz

Date: 7.MAR.2019 14:46:33

NTNV_2GFSK _926.3_915~930

Page 38 of 49
Dongguan Dongdian Testing Service Co., Ltd. Report No.: DDT-R19022803-1E1

* RBW 100 kHz Marker 1 [T1 ]


* VBW 100 kHz -76.17 dBm
Ref 0 dBm * Att 0 dB SWT 85 ms 915.912000000 MHz

0 Offset 1 dB

A
-10

1 PK
MAXH
-20
LVL

-30

-40

-50
D1 -54 dBm
3DB
-60

-70
1

-80

-90

-100

Start 915 MHz 1.5 MHz/ Stop 930 MHz

Date: 7.MAR.2019 14:46:42

NTNV_2GFSK _926.3_930~1000
* RBW 100 kHz Marker 1 [T1 ]
* VBW 100 kHz -77.01 dBm
Ref 0 dBm * Att 0 dB SWT 35 ms 988.143750000 MHz

0 Offset 1 dB

A
-10

1 PK
MAXH
-20
LVL

-30

-40

-50

D1 -55 dBm
3DB
-60

-70
1

-80

-90

-100

Start 930 MHz 7 MHz/ Stop 1 GHz

Date: 7.MAR.2019 14:46:51

NTNV_2GFSK _926.3_1000~5000
* RBW 1 MHz Marker 1 [T1 ]
* VBW 1 MHz -77.98 dBm
Ref 0 dBm * Att 0 dB SWT 85 ms 2.608800000 GHz

0 Offset 1 dB

A
-10

1 PK
VIEW
-20
LVL

-30

-40

D1 -47 dBm
-50

3DB
-60

-70

-80

-90

-100

Start 1 GHz 400 MHz/ Stop 5 GHz

Date: 7.MAR.2019 14:47:21

Page 39 of 49
Dongguan Dongdian Testing Service Co., Ltd. Report No.: DDT-R19022803-1E1

11. Controller Measurement

11.1. Limit
Table 3-18 Possible combinations of sending control parameters specified by 3.4.1
Sending control, 3.4.2 Carrier sense and 3.4.3 Skipping carrier sense in a response

(Note1) It may emit again without waiting 50ms, if it is within 4s after its first transmission.
The transmission shall start after carrier sense is performed for 128μs or more and the
transmission shall finish within this 4s interval.
(Note2) It may emit again without waiting 100ms, if it is within 100ms after its first
transmission and the transmission is finished within this 100ms interval.
(Note3) It may emit again without waiting 50ms, if it is within 50ms after its first
transmission and the transmission is finished within this 50ms interval.
(Note4) Transmission time of a response that satisfies the conditions is not included in the
sum of transmission time per arbitrary one hour.
(Note5) 250mW or less is allowed given the RF circuit and modulation modules except for
antenna are shielded inside the metal cabinet and shall be structured not to be opened easily
without special tool, and its EIRP (Note) is 16dBm or 3dBm or less (value when
applying 20mW or 1mW of antenna power to the transmitting antenna having absolute
gain of 3dBi). Here, EIRP is the value when antenna power is applied to the antenna
gain and it includes the deviation of the antenna power.
(Note6) When a transmission using different center frequency is used after the previous
transmission is completed, transmission in a different frequency channel is allowed after
2ms of the completion of transmission in the former channel without waiting for ten
times or more of the former transmission time.

Page 40 of 49
Dongguan Dongdian Testing Service Co., Ltd. Report No.: DDT-R19022803-1E1

11.2. Block diagram of test setup

EUT Attenuator Distributor Spectrum


analyzer

Signal generator

11.3. Test Procedure


(1) Set the standard signal generator as follow:
Carrier frequency: Center of reception frequency band of the EUT
Output level: -80dBm.

(2) Set the spectrum analyzer as follow:


Carrier frequency: Center of reception frequency band to be used
Frequency sweep width: 3 MHz
Resolution bandwidth: 100 kHz
Video bandwidth: 300 kHz
Y-axis scale: 10 dB/Div
Trigger condition: Free run
Detection mode: Positive peak

11.4. Test result


Transmission time control equipment

In case the 128μs or more and less than 5ms carrier sense time
Limit
The sum of
Frequency (MHz) Transmission of radio
transmission time per
wave
arbitrary one hour
3.205 ms 3.205 ms
922.4 to 928.0
less than 100 ms shall be 360 s or less
Note: The sum of transmission time declared by client is less than 360s one hour
Conclusion: PASS

Page 41 of 49
Dongguan Dongdian Testing Service Co., Ltd. Report No.: DDT-R19022803-1E1

Carrier sense
Carrier sense level
Frequency (MHz) Result
[dBm]
Radio equipment stop emit any
922.5 -80
radio wave

Not: Test is carried out with 922.5MHz because there are no differences between Frequency.

11.5. Original test data


Mode (Tx Freq.
Transmission of radio wave
Mode) (MHz)

2GFSK 922.5

Mode (Tx Freq.


Carrier sense
Mode) (MHz)
RBW 100 kHz Delta 1 [T1 ]
* VBW 300 kHz 53.47 dB
Ref 5 dBm * Att 0 dB SWT 100 ms 1.602564 ms

Marker 1 [T1 ]
0 -61.97 dBm
45.512821 ms A
1
SGL
1 AP -10
CLRWR

-20

-30

-40

-50
3DB

2GFSK 922.5 -60


1

-70

-80

-90

Center 922.5 MHz 10 ms/

Date: 8.MAR.2019 15:20:46

Page 42 of 49
Dongguan Dongdian Testing Service Co., Ltd. Report No.: DDT-R19022803-1E1

12. Interference prevention function

12.1. Limit
N/A

12.2. Block diagram of test setup

Receiver
EUT Attenuator
equipment

12.3. Test result


Link Mode Result
Normal Pass

Page 43 of 49
Dongguan Dongdian Testing Service Co., Ltd. Report No.: DDT-R19022803-1E1

13. Test setup photograph

Page 44 of 49
Dongguan Dongdian Testing Service Co., Ltd. Report No.: DDT-R19022803-1E1

14. Photos of the EUT

Page 45 of 49
Dongguan Dongdian Testing Service Co., Ltd. Report No.: DDT-R19022803-1E1

Page 46 of 49
Dongguan Dongdian Testing Service Co., Ltd. Report No.: DDT-R19022803-1E1

Page 47 of 49
Dongguan Dongdian Testing Service Co., Ltd. Report No.: DDT-R19022803-1E1

Page 48 of 49
Dongguan Dongdian Testing Service Co., Ltd. Report No.: DDT-R19022803-1E1

END OF REPORT

Page 49 of 49