You are on page 1of 5

BOQ of Material for Fire Hydrant Detection and Foam System

SUPER PETROCHEMICAL LIMITED


DANGARCHAR, JULDHA, KARNAPHULI, CHITTAGONG.

Qty Unit
Sl No Specification Of Products Sample Picture

1 Fire Alarm Control Panel 2 Set


Conventional Fire Detection Panel
(Panel for Total 30 Deluge Valve + 30 MCP + 30 Sounder)

2 Foam Bledder Tank 3 Set


1400 Ltr
(Additional Tank for Cover whole 06 Tanks)

3 Explosion-proof Ultraviolet Flame Detector 35 Set


Working Angle: 120 0
Working Temperature: -10℃-+55℃
Sensor: Career Exploration AE-S708 / 4 & S708/ 5

4 Explosion proof manual alarm button 30


Operating voltage: DC24V (Power LED) (no polarity)
Contact capacity: 0.5A
Indicator: Normal standby: green; Alarm status: red

5 Explosion Weather-Proof Strobe Sounder 30 Set


Explosion-proof mark: Exd ibⅡCT6
Working voltage: DC24V
Alarm current: ≤650mA
Sound intensity: 110dB ~ 120dB

6 Syren 1 pc
220 VAC

7 Fire Proof Cable mtr


FR 2x1.5 rm

8 Deluge Valve 30 Set


Size: 150 mm
Material : SS304
Operating Voltage: 220 VAC
Qty Unit
Sl No Specification Of Products Sample Picture

9 Gate Valve 12 Nos


Size: 150 mm
Material: CI

10 Gate Valve 30 Nos


Size: 100 mm
Material: CI

11 MS Pipe 1100 mtr


Size: 150 mm
Schedule 40

12 MS Pipe 200 mtr


Size: 100 mm
Schedule 40

13 Fire Hose Box 15 Nos


Size: 40 mm
Accessories- Dia 40 mm
a) Angle Valve
b) Hose Pipe
c) Nozzle
d) Hose Rack
e) Hose Box (800 x 700 x 250)

14 Landing Valve 8 Nos


Size: 65 mm

15 Lightning Mast 13 Set


Ground Grid for Lightning Protection System
Coverage Area Radious-196'
(Proposed, Existing qnty will be Deducted)

16 Addressable Smoke Detector Nos Nos


(Balance
with
stock
and
Installati
on)
17 Addressable Heat Detector

18 Addressable Multi Detector


Qty Unit
Sl No Specification Of Products Sample Picture

19 Addressable Manual Call Point

20 Addressable Input / Output Module

21 Conventional Sounder / Strobe

21 FM 200 Suppression System 2 Nos


Tank Size 60 Ltr
MCC -1 Room Size 19 x 36 x 10

22 FM 200 Suppression System 1 Nos


Tank Size 60 Ltr
MCC -2 Room Size 20 x 30 x 10

23 FM 200 Suppression System 1 Nos


Tank Size 60 Ltr
MCC -2 Room Size 20 x 30 x 10

24 FM 200 Suppression System 1 Nos


Tank Size 60 Ltr
Control Room. Room Size 35 x 30 x 12

25 FM 200 Suppression System 2 Nos


Tank Size 60 Ltr
Sub Station & Switch Gear Room
Room Size 35 x 30 x 13

26 Fire Rated Door 3 Nos


2 Hrs Fire Rated Door
6' x 7'

27 Fire Rated Door 10 Nos


2 Hrs Fire Rated Door
4'' x 7'

27 Pump Room 6000 CFT


Positive Suction
20' x 30' x 10' , Level (-)10
1 Feet Mtr
L 455 138.7195 140.2 1.5
W 250.25 76.29573 76.4 0.1
0.0
0.0
2 Feet Mtr
L 455 138.7195 140.2 1.5
W 138 42.07317 42.21 0.1

3 Feet Mtr
L 351.5 107.1646 107.2 0.0
W 241.5 73.62805 73.7 0.1

Pipe 6'' 430 40 370 265 265


   Dyke1-
L-
140.2m,
W-76.4
m
    Dyke2
-L-
140.2m,
W-
42.1m  
    Dyke3
-L-
107.2m,
W-
73.7m

480 80 200 470 480 3080 939.0244 1032.927