Professional Documents
Culture Documents
Rev 2 – 01-10-18
SAFETY FIRST
PSYCHOLOGICAL
SAFETY
2
GLOBAL INTERNAL CONTROLS
Control leads to
Ensure
compliance
We all need to
with all relevant
be compliant
internal and
external rules
and regulation
Conducting
business with
‘Power of ethics and
Sandvik’ are integrity
the guidelines
for all
employees
QUALITY FOCUS
4
HEALTH AND SAFETY
5
FAULT CODE 800104 FEEDER RADIO STOP ACTIVATED
COMPONENT LOCATION
Socket location
6
FAULT CODE 800104 FEEDER RADIO STOP ACTIVATED
SYSTEM LOGIC 2017
Fault 800104
7
FAULT CODE 800104 FEEDER RADIO STOP ACTIVATED
SYSTEM LOGIC 2017 The radio receiver, receives
signals from the radio control.
These signals are sent to the
system via a can bus system
Cntrol
Panel
8
FAULT CODE 800104 FEEDER RADIO STOP ACTIVATED
CIRCUIT LAYOUT
Radio Receiver In Out Module Breakout Out Module
Fuse/Relay Module
Panel Module
FAULT CODE 800104 FEEDER RADIO STOP ACTIVATED
TESTING (2017)
Test Points:
Radio Receiver
Radio CAN – Wired Track Control
• Network resistance is
60 Ohms if system is healthy
10
FAULT CODE 800104 FEEDER RADIO STOP ACTIVATED
TESTING RESISTANCE
Test for resistance between pin 1 and 3 Test for resistance between pin 22 and 23
11
ROCKTECHNOLOGY.SANDVIK