Professional Documents
Culture Documents
Alamat : JL.DUKU211,RT3/1,DESADUKU
Disk
No. Elev. H Foot Side Azimuth Ket.
Diameter
[m] [m] [Deg]
1 41.40 1.40 B 30 SECTORAL TSEL
2 41.30 1.40 A 210 SECTORAL TSEL
3 41.30 1.40 D 270 SECTORAL TSEL
4 41.30 1.40 A 40 SECTORAL TSEL
5 41.30 1.40 B 120 SECTORAL TSEL
6 41.30 1.40 C 300 SECTORAL TSEL
7 40.20 0.49 A 210 RRU TSEL
8 40.20 0.49 D 270 RRU TSEL
9 38.80 0.49 A 40 RRU TSEL
10 38.80 0.49 B 120 RRU TSEL
11 38.80 0.49 C 300 RRU TSEL
12 37.30 1.30 A 30 SECTORAL TSEL
13 37.30 1.30 B 260 SECTORAL TSEL
14 37.30 1.30 C 300 SECTORAL TSEL
15 35.30 0.49 A 30 RRU TSEL
16 35.30 0.49 B 260 RRU TSEL
17 35.30 0.49 C 300 RRU TSEL
18 31.70 0.60 C 180 MW RADOME TSEL
19 31.70 0.25 C 180 ODU TSEL
20 30.50 2.00 A 300 SECTORAL XL
21 30.50 2.00 B 90 SECTORAL XL
22 30.50 2.00 D 200 SECTORAL XL
23 29.80 0.49 A 300 RRU XL
24 29.80 0.49 B 90 RRU XL
25 29.80 0.49 D 200 RRU XL
Disk
No. Elev. H Foot Side Azimuth Ket.
Diameter
[m] [m] [Deg]
- - - -
- - - -
- - - -
- - - -
- - - -
Daftar Ketidaksesuaian
Keadaan permukaan : Baik
Keadaan cat besi tower : Baik
Kondisi karat besi tower : Baik
Detail Baseplate : Baik
Penangkal Petir : Ada
Lampu Tower : Baik
Grounding dan Pentanahan : Baik ( 0.89 < 1ohm)
VII. KESIMPULAN
Tower membutuhkan perkuatan (eksisting tower sudah ada perkuatan redundant), Anchor Bolt
dan Base Plate masih aman dan tidak memerlukan perkuatan
Jakarta, 06 / 10 / 2020
................................................
Denny Yatmadi ................................................