TROUBLE STUDER M/C _S20CNC_21005360013

This m/c has trouble monitor not show up when turn on the power.
Part Name Part Spec Q’ty Trouble
1. PSU A16B-1212-0871 1 Old PSU burn out (before service)
2. MAIN BOARD A16B-2200-0900 1 For trouble monitor not show up
3. BACK PANEL A20B-2000-0640-R 1 For trouble monitor not show up
4. SERVO MODULE A20B-2902-0400 1 For trouble alarm 920
5. FAN MOTOR A90L-0001-0378 2 For trouble FAN dirty
6. MACRO ROM A20B-2900-0290 - ***Not use FANUC parts
(must be install data from MTB)
Please contact to MTB for this parts
Problem solution
1. For trouble monitor not show up replace all part in NC side.
2. Confirm parts faulty and return good part.
3. Found main board , back panel and MACRO ROM module faulty.
4. Not return PSU Because PSU burn out before service.
5. Found fan dirty and replace fan motor. And Restore data.
6. Found trouble 920 when test move m/c.
7. Replace servo module for Alarm 920.
8. Test move m/c is okay.
9. Now m/c don’t has MACRO ROM MODULE can’t run m/c only test move m/c.
*** Please contact to MTB for MACRO ROM module A20B-2900-0290 must be install
SOFTWARE from MTB.

***REFERENT SERVICE REPORT NO.60971 DATE 16/1/2020