You are on page 1of 8

4016-61 TRG Generating Sets

Features & Benefits


Overview

FG Wilson Power Solutions are pleased to


introduce the 4016-61TRG powered range of
Generating Sets

Complements current product range and


extends up to 2500 kVA Standby, 50 Hz

Enhanced levels of Performance & Reliability


as well as reduction in operating and
installation costs

Range of Cooling System, Control Panel and


Enclosure Options available upon request

Available to order NOW through FG Wilson


Power Solutions
Ratings Summary

* Current product will remain available to order


Building on Success

4016-61 TRG built on success of 4012-46 product

• Performance
– New exhaust manifolds
– Revised turbo arrangement
– Optimised fuel system
– New digital governor

• Reliability & Durability


– Improved rocker assembly and
fixing
– Revised cam follower assembly
– Improved pushrods
– New intake manifolds
Introduction

• Perkins 4000 Series 6, 8, 12, & 16


Cylinder Engine Range
– 6, 12, & 16 cylinder refresh models

• Alternators with AREP Excitation


– 7000 – 9000 Series Alternators

• Electronic Governing
• Engine Mounted Fuel/Water Separator
• Fuel Cooler (integral to cooling system)
• Lifting Points on Baseframe
• Charge Air Cooled
Product Range

• 730 – 2500kVA Gensets


4006 Series
P730P1 / P800E1 4006-23TAG2A
P800P1 / P900E1 4006-23TAG3A 4016 Series
P1750 / P1925E 4016TAG
4008 Series P1825 / P2000E 4016TAG1A
P910P1 / P1000E1 4008TAG1A P2000 / P2200E 4016TAG2A
P1000P1 / P1100E1 4008TAG2A
4016 Series Refresh
4012 Series P1850P1 / P2000E1 4016-61TRG1
P1250P3 / P1375E3 4012-46TWG2A P2000P1 / P2250E1 4016-61TRG2
P1350P1 / P1500E1 4012-46TWG3A P2250P1 / P2500E1 4016-61TRG3
P1500P3 / P1650E3 4012-46TAG2A
P1700P1 / P1875E1 4012-46TAG3A
4016 Refresh

• New Node Introduced


– 2250kVA Prime & 2500 kVA Standby
• Improved Ambient/Altitude Capability
– 50°
°C at 0m / 40°C at 1000m
– Unaided cold starting capability at 0°C

• New Charge Air Pipe Arrangement


– Charge Air to Water Intercooler
• Branched Exhaust Manifolds
– Increased turbo airflow & efficiency
• High Efficiency Turbochargers:
– Increased power density & ambient capability
• Optimised Cooling System
– Engine mounted charge air coolers
– Reduced radiator size for shipping/packing
• Standard Service Interval extended to
500hrs
Key Product Improvements

• Introduction of 2500 kVA Standby Rating


– Key market power node
• Improved Ambient/Altitude Capability
– 50°
°C at 0m / 40°C at 1000m
– Unaided cold starting capability at 0°C
• Optimised Cooling System
– Engine mounted charge air coolers
– Reduced radiator size for shipping/packing
• Extended Service Intervals
– 500 hr service interval - Oil and Filters