Introduction
Floors and ceilings
British Gypsum offers a full range of specifications
from simple plasterboard ceilings through to a
range of gypsum-based, acoustic suspended
ceilings and lay-in grid systems. They cover all
building categories, including private and social
housing, apartments, healthcare, educational
facilities, recreational and industrial properties in
both new-build and refurbishment and can satisfy
the most demanding performance requirements.
C06
satisfy your project requirements.
Fire Installed
Acoustic performance
performance cavity depth System Page
mins mm RwdB Rw + CtrdB Ln,w dB αw
1
Where the floor can only be accessed from above, the fire and accoustic performances can be upgraded with the GypFloor silent system.
2
Indicative first test performance only.
Table 1 – Recommended laboratory performance to meet requirements of Building Regulations Approved Document E
(England and Wales)
Where applicable Minimum airborne Recommended Maximum impact Recommended
sound insulation performance Rw + Ctr sound transmission performance
DnT,w + Ctr (site test result) (laboratory test result) L’nT,w (site test result) Ln,w (laboratory test result)
Separating walls between new homes 45dB 54dB - -
Separating walls between purpose-built 43dB 52dB - -
rooms for residential purposes
Separating walls between rooms created by 43dB 52dB - -
a change of use or conversion
Separating floors between new homes and 45dB 54dB 62dB 57dB - 52dB
purpose-built rooms for residential purposes (depending on
construction method)
Separating floors between rooms created by 43dB 52dB 64dB 59dB - 54dB
a change of use or conversion (depending on
construction method)
Table 2 – Recommended laboratory performance to meet requirements of Technical Handbook Section 5 (Scotland)
Where applicable Minimum airborne Recommended Maximum impact Recommended
sound insulation performance Rw sound transmission performance
DnT,w (site test result) (laboratory test result) L’nT,w (site test result) Ln,w (laboratory test result)
Floors and ceilings
1
Definition of traditional buildings.
A building or part of a building of a type constructed before or around 1919:
a) using construction techniques that were commonly in use before 1919; and
b) with permeable components, in a way that promotes the dissipation of moisture from the building fabric.
Introduction
Table 3 – Sound absorption data for Gyptone boards
1.0
0.6
0.4
125 250 500 1k 2k 4k αW AC1 NRC2
0.0
C06
125 250 500 1000 2000 4000
Frequency (Hz)
1.0
Gyptone quattro 46 (plenum depth 400mm)
0.8 Gyptone quattro 46 (plenum depth 400mm plus
0.6
100mm Isover Spacesaver Ready-Cut)
0.4
1
AC - Absorption Class.
2
NRC - Noise Reduction Coefficient.
3
Due to installation limitations the minimum cavity size that can be constructed with CasoLine mf or CasoLine curve system is 100mm. The sound absorption
performance for these systems is estimated to be equivalent to that of the same system built with a 50mm plenum.
All products have been tested to BS EN 20354 and ISO 354. The single figure rating practical sound absorption coefficient αw is calculated in accordance
with EN ISO 11654. Suffix letters indicate where performance is limited at either low, medium or high frequencies.
0.2
0.0
125 250 500 1k 2k 4k αW AC1 NRC2
125 250 500 1000 2000 4000
Frequency (Hz)
0.45 0.50 0.45 0.40 0.30 0.25 0.35(L) D 0.40
System reference
C10A016 0.50 0.55 0.50 0.40 0.30 0.30 0.40(L) D 0.45
C10A017
Floors and ceilings
1.0
0.8
Gyptone line 6 (plenum depth 400mm plus
100mm Isover Spacesaver Ready-Cut)
0.6
0.2
αW
C06
1.0
0.6
0.4
125 250 500 1k 2k 4k αW AC1 NRC2
0.2
0.35 0.60 0.70 0.60 0.55 0.55 0.60 C 0.60
0.0
125 250 500 1000 2000 4000
Frequency (Hz)
System reference
C10A115
1
AC - Absorption Class.
2
NRC - Noise Reduction Coefficient.
All products have been tested to BS EN 20354 and ISO 354. The single figure rating practical sound absorption coefficient αw is calculated in accordance
with EN ISO 11654. Suffix letters indicate where performance is limited at either low, medium or high frequencies.
Introduction
Table 4 – Sound absorption data for Rigitone boards
0.8
Rigitone 8-15-20 super (plenum depth 200mm)
0.6
Rigitone 8-15-20 super (plenum depth 200mm plus
0.4 50mm Isover Frame Batt 32)
0.2
0.0
Practical absorption coefficient αp
125 250 500 1000 2000 4000
System reference C10A058 0.15 0.40 0.70 0.75 0.45 0.40 0.50(M) D 0.55
C10A059
0.35 0.75 0.75 0.55 0.40 0.30 0.45(LM) D 0.60
C10A069
0.60 0.85 0.80 0.65 0.45 0.30 0.45(LM) D 0.70
1.0
0.8
Rigitone 8/18 (plenum depth 200mm)
Rigitone 8/18 (plenum depth 200mm plus 50mm Isover Frame Batt 32)
0.6
0.2
αW AC1 NRC2
C06
125 250 500 1k 2k 4k
0.0
125 250 500 1000 2000 4000
Frequency (Hz)
0.10 0.30 0.65 0.85 0.55 0.30 0.50(M) D 0.55
System reference C10A036 0.35 0.75 0.90 0.60 0.50 0.40 0.55(LM) D 0.70
C10A037
C10A060 0.60 0.95 0.95 0.80 0.70 0.50 0.70(LM) C 0.85
1.0
0.8
Rigitone 8/18 q (plenum depth 200mm)
Rigitone 8/18 q (plenum depth 200mm plus
0.6
0.2
Practical absorption coefficient αp
0.0
125 250 500 1000
Frequency (Hz)
2000 4000
125 250 500 1k 2k 4k αW AC1 NRC2
1
AC - Absorption Class.
2
NRC - Noise Reduction Coefficient.
3
Due to installation limitations the minimum cavity size that can be constructed with CasoLine mf or CasoLine curve system is 100mm. The sound absorption
performance for these systems is estimated to be equivalent to that of the same system built with a 50mm plenum.
All products have been tested to BS EN 20354 and ISO 354. The single figure rating practical sound absorption coefficient αw is calculated in accordance
with EN ISO 11654. Suffix letters indicate where performance is limited at either low, medium or high frequencies.
0.8
Rigitone 10/23 (plenum depth 200mm)
Rigitone 10/23 (plenum depth 200mm plus
0.6
αW AC1 NRC2
0.0
125 250 500 1000 2000 4000 125 250 500 1k 2k 4k
Frequency (Hz)
1.0
αW AC1 NRC2
0.0
125 250 500 1000 2000 4000 125 250 500 1k 2k 4k
Frequency (Hz)
1.0
0.2
Practical absorption coefficient αp
0.0
125 250 500 1000 2000 4000
125 250 500 1k 2k 4k αW AC1 NRC2
Frequency (Hz)
1
AC – Absorption Class.
2
NRC – Noise Reduction Coefficient.
3
Due to installation limitations the minimum cavity size that can be constructed with CasoLine mf or CasoLine curve system is 100mm. The sound absorption
performance for these systems is estimated to be equivalent to that of the same system built with a 50mm plenum.
All products have been tested to BS EN 20354 and ISO 354. The single figure rating practical sound absorption coefficient αw is calculated in accordance
with EN ISO 11654. Suffix letters indicate where performance is limited at either low, medium or high frequencies.
Introduction
Table 4 (continued) – Sound absorption data for Rigitone boards
0.2
Practical absorption coefficient αp
0.0
αW AC1 NRC2
125 250 500 1000 2000 4000
Frequency (Hz)
125 250 500 1k 2k 4k
System reference C10A131 0.10 0.30 0.65 0.90 0.80 0.60 0.60(M) C 0.65
C10A130
C10A132 0.35 0.75 0.90 0.70 0.65 0.50 0.65(LM) C 0.75
1.0
0.8
Rigitone 15/30 (plenum depth 200mm)
Rigitone 15/30 (plenum depth 200mm plus
0.6
0.2
Practical absorption coefficient αp
C06
αW
0.0
125 250 500 1000 2000 4000
125 250 500 1k 2k 4k AC1 NRC2
Frequency (Hz)
1
AC – Absorption Class.
2
NRC – Noise Reduction Coefficient.
3
Due to installation limitations the minimum cavity size that can be constructed with CasoLine mf or CasoLine curve system is 100mm. The sound absorption
performance for these systems is estimated to be equivalent to that of the same system built with a 50mm plenum.
All products have been tested to BS EN 20354 and ISO 354. The single figure rating practical sound absorption coefficient αw is calculated in accordance
with EN ISO 11654. Suffix letters indicate where performance is limited at either low, medium or high frequencies.
CasoLine curve
Concealed grid curved ceiling system
curved ceilings and soffit linings. It can be used Refer to C02. S01. P49
interior design.
Key benefits
— Can be used to create a unique, creative ceiling
design using concave or convex curves down to
a minimum radius of 600mm depending on
board used
— Compatible with a wide range of British Gypsum
C06
CasoLine curve comprises Gypframe MF7C Curved Support Refer to C08. S03. P04 – Finishes.
Channels, Gypframe MF5 Ceiling Sections and Gypframe MF7
Primary Support Channels. Whilst a good quality finish can be achieved using normal jointing
techniques, a plaster skim finish may be considered (with the exception of
Gyptone and Rigitone boards), particularly where there are a number of
Planning – key factors butt-end joints on the curve.
Gypframe MF7C Curved Support Channel is supplied pre-formed Refer to British Gypsum Ceiling Installation Guide.
to the radius required. Board joints should be avoided on the apex
of the curve for the exposed layer of board. Gypframe MF5 Ceiling
Section positions should therefore be pre-determined at the
design stage. SpecSure®
Degree of curvature All our systems are covered by SpecSure® when
In common with other sheet materials, board-ends have a tendency using genuine British Gypsum and Saint-Gobain
to remain straight, and so the minimum achievable radius will be Isover products.
influenced by the board characteristics, the length of curve, the
support centres, and the occurrence of board joints.
Refer to table 1.
Board type Thickness Minimum radius1 MF52 centres Span (suspension points) of MF7C3 MF7C3 centres
mm mm mm mm mm
1
Concave or convex.
2
Gypframe MF5 Ceiling Section.
3
Gypframe MF7C Curved Support Channel.
4
ACTIVair technology as standard.
CasoLine curve
1 2
2
4
7
2
6
m
0m
30
10
1
3 4
C06
4
11
7
3
3
7
Hanger - Gypframe MF7C Curved Support Channel Alternative hanger - Gypframe MF7C Curved Support Channel
connection using strap connection using Gypframe FEA1 Steel Angle
1 Gypframe MF6 Perimeter Channel 7 British Gypsum Wafer Head Jack-Point Screw
2 Gypframe MF5 Ceiling Section 8 Fixing to structure
3 Gypframe MF7C Curved Support Channel 9 Gypframe FEA1 Steel Angle
4 Gypframe MF8 Strap Hanger 10 Gypframe MF6 Perimeter Channel, cut and bent to required curve
5 Timber fillet 11 Gypframe FEA1 Steel Angle, cut and bent
6 British Gypsum lining board
3 2
10 10
0m
0m
m m
Method: where curvature changes from convex to
concave an additional hanger is required.
6
A
Floors and ceilings
3 Section A-A
3
A
1
C06
2
2
1
Concave curvature
7
2
1
B
B
Section B-B
B 2
B
4 3
3 4
Convex curvature
CasoLine curve
Gypframe metal components ( Refer to C10. S02. P02 for details)
C06
Standard gypsum plasterboard. Gypsum plasterboard with fire resistant additives.
Ceiling boards
A full range of Gyptone2 and Rigitone2 boards are
available to meet specific aesthetic and/or acoustic
requirements.
2
ACTIVair technology as standard.
3
Also available in Moisture Resistant (mr) version. mr boards are specified in intermittent wet use areas.
British Gypsum Drywall Screws British Gypsum Wafer Head Jack-Point Screws
Corrosion resistant self-tapping steel screws Corrosion resistant self-tapping steel screws
for fixing board to metal framing less than for fixing metal to metal framing 0.8mm thick
0.8mm thick. and greater, for example connecting Gypframe
components to the Gypframe MF7C Courved
Support Channel.
Protecting and enhancing board edges and corners. A paper tape designed for reinforcement of flat
joints or internal angles.
CasoLine curve
Ceiling products ( Refer to C10. S08. P02 for details)
C06
Rigitone 8/18 q1 Rigitone 12/25 q1
Acoustic board with a perforated pattern of Acoustic board with a perforated pattern of
8mm squares capable of providing Class B 12mm squares capable of providing Class B
absorption. absorption.
1
ACTIVair technology as standard.
Gypframe MF6 Perimeter Channel is fixed Suspension for a flat soffit Gypframe MF5 Ceiling sections are screw
at wall positions to the line of the curve. Gypframe MF12 Soffit Cleats are secured to fixed at right angles to the underside of the
Timber fillets are installed where required to the soffit using appropriate fixings. pre-formed support channel to form the
pack out the channel. Gypframe FEA1 Steel Angle hangers are pre- secondary grid, with two British Gypsum
cut and secured to the soffit cleats. Wafer Head Jack-Point Screws per junction.
Pre-formed Gypframe MF7C Curved Support
Channel is installed over the perimeter For convex curvature, insert a small section
of Gypframe MF7 Primary Support Channel to
channels and secured to the hangers. provide a flat, positive fixing at the apex. Refer to
construction detail 7.
Suspension from timber joists
Floors and ceilings
When using Gyptone or Rigitone products please refer to the current British Gypsum Ceiling Installation Guide.
Additional information
For full installation details, refer to the
British Gypsum Ceiling Installation Guide, available to
download from british-gypsum.com