You are on page 1of 185

Draft DRAFT

Lecture Notes in:

Mechanics and Design of


REINFORCED CONCRETE
CVEN4555


c VICTOR E. SAOUMA,

Fall 2001

Dept. of Civil Environmental and Architectural Engineering


University of Colorado, Boulder, CO 80309-0428

May 18, 2002


Draft
0–2

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft

Contents

1 INTRODUCTION 1–1
1.1 Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–1
1.1.1 Concrete . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–1
1.1.1.1 Mix Design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–1
1.1.1.1.1 Constituents . . . . . . . . . . . . . . . . . . . . . . . . 1–1
1.1.1.1.2 Preliminary Considerations . . . . . . . . . . . . . . . . 1–5
1.1.1.1.3 Mix procedure . . . . . . . . . . . . . . . . . . . . . . . 1–5
1.1.1.1.4 Mix Design Example . . . . . . . . . . . . . . . . . . . 1–8
1.1.1.2 Mechanical Properties . . . . . . . . . . . . . . . . . . . . . . . . 1–9
1.1.2 Reinforcing Steel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–13
1.2 Design Philosophy, USD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–14
1.3 Analysis vs Design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–15
1.4 Basic Relations and Assumptions . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–16
1.5 ACI Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–16

2 FLEXURE 2–1
2.1 Uncracked Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2–1
E 2-1 Uncracked Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2–2
2.2 Section Cracked, Stresses Elastic . . . . . . . . . . . . . . . . . . . . . . . . . . . 2–3
2.2.1 Basic Relations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2–3
2.2.2 Working Stress Method . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2–4
E 2-2 Cracked Elastic Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2–5
E 2-3 Working Stress Design Method; Analysis . . . . . . . . . . . . . . . . . . . 2–6
E 2-4 Working Stress Design Method; Design . . . . . . . . . . . . . . . . . . . 2–7
2.3 Cracked Section, Ultimate Strength Design Method . . . . . . . . . . . . . . . . . 2–8
2.3.1 Whitney Stress Block . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2–8
2.3.2 Balanced Design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2–10
2.3.3 Review . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2–11
2.3.4 Design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2–11
2.4 Practical Design Considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2–12
2.4.1 Minimum Depth . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2–12
2.4.2 Beam Sizes, Bar Spacing, Concrete Cover . . . . . . . . . . . . . . . . . . 2–13
2.4.3 Design Aids . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2–13
2.5 USD Examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2–15
E 2-5 Ultimate Strength; Review . . . . . . . . . . . . . . . . . . . . . . . . . . 2–15
E 2-6 Ultimate Strength; Design I . . . . . . . . . . . . . . . . . . . . . . . . . . 2–16
E 2-7 Ultimate Strength; Design II . . . . . . . . . . . . . . . . . . . . . . . . . 2–17
Draft
0–2

2.6 T Beams, (ACI 8.10) . . . . . . . . . . . . . . . . . . . . . . . . . . .


CONTENTS

. . . . . . 2–17
2.6.1 Review . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2–19
2.6.2 Design, (balanced) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2–19
E 2-8 T Beam; Moment Capacity I . . . . . . . . . . . . . . . . . . . . . . . . . 2–20
E 2-9 T Beam; Moment Capacity II . . . . . . . . . . . . . . . . . . . . . . . . . 2–21
E 2-10 T Beam; Design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2–22
2.7 Doubly Reinforced Rectangular Beams . . . . . . . . . . . . . . . . . . . . . . . . 2–23
2.7.1 Tests for fs and fs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2–24
2.7.2 Moment Equations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2–26
E 2-11 Doubly Reinforced Concrete beam; Review . . . . . . . . . . . . . . . . . 2–28
E 2-12 Doubly Reinforced Concrete beam; Design . . . . . . . . . . . . . . . . . . 2–30
2.8 Bond & Development Length . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2–31
2.8.1 Moment Capacity Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . 2–35

3 SHEAR 3–1
3.1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3–1
3.2 Shear Strength of Uncracked Section . . . . . . . . . . . . . . . . . . . . . . . . . 3–2
3.3 Shear Strength of Cracked Sections . . . . . . . . . . . . . . . . . . . . . . . . . . 3–4
3.4 ACI Code Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3–6
3.5 Examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3–7
E 3-1 Shear Design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3–7
3.6 Shear Friction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3–8
E 3-2 Shear Friction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3–11
3.7 Brackets and Corbels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3–11
3.8 Deep Beams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3–12

4 CONTINUOUS BEAMS 4–1


4.1 Continuity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4–1
4.2 Methods of Analysis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4–2
4.2.1 Detailed Analysis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4–2
4.2.2 ACI Approximate Method . . . . . . . . . . . . . . . . . . . . . . . . . . . 4–2
4.3 Effective Span Design Moment . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4–4
4.4 Moment Redistribution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4–4
4.4.1 Elastic-Perfectly Plastic Section . . . . . . . . . . . . . . . . . . . . . . . . 4–4
4.4.2 Concrete . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4–5
E 4-1 Moment Redistribution . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4–6
4.5 Buildings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4–7

5 SERVICEABILITY 5–1
5.1 Control of Cracking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5–1
E 5-1 Crack Width . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5–3
5.2 Deflections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5–4
5.2.1 Short Term Deflection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5–4
5.2.2 Long Term Deflection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5–5
E 5-2 Deflections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5–7

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
CONTENTS

6 APPROXIMATE FRAME ANALYSIS


0–3

6–1
6.1 Vertical Loads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6–1
6.2 Horizontal Loads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6–4
6.2.1 Portal Method . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6–4
E 6-1 Approximate Analysis of a Frame subjected to Vertical and Horizontal
Loads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6–6

7 ONE WAY SLABS 7–1


7.1 Types of Slabs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7–1
7.2 One Way Slabs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7–4
7.3 Design of a One Way Continuous Slab . . . . . . . . . . . . . . . . . . . . . . . . 7–5

8 COLUMNS 8–1

9 COLUMNS 9–1
9.1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9–1
9.1.1 Types of Columns . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9–1
9.1.2 Possible Arrangement of Bars . . . . . . . . . . . . . . . . . . . . . . . . . 9–1
9.2 Short Columns . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9–3
9.2.1 Concentric Loading . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9–3
9.2.2 Eccentric Columns . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9–3
9.2.2.1 Balanced Condition . . . . . . . . . . . . . . . . . . . . . . . . . 9–4
9.2.2.2 Tension Failure . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9–5
9.2.2.3 Compression Failure . . . . . . . . . . . . . . . . . . . . . . . . . 9–6
9.2.3 ACI Provisions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9–7
9.2.4 Interaction Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9–8
9.2.5 Design Charts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9–8
E 9-1 R/C Column, c known . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9–8
E 9-2 R/C Column, e known . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9–10
E 9-3 R/C Column, Using Design Charts . . . . . . . . . . . . . . . . . . . . . . 9–14
9.2.6 Biaxial Bending . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9–15
E 9-4 Biaxially Loaded Column . . . . . . . . . . . . . . . . . . . . . . . . . . . 9–18
9.3 Long Columns . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9–19
9.3.1 Euler Elastic Buckling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9–19
9.3.2 Effective Length . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9–20
9.3.3 Moment Magnification Factor; ACI Provisions . . . . . . . . . . . . . . . 9–22
E 9-5 Long R/C Column . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9–25
E 9-6 Design of Slender Column . . . . . . . . . . . . . . . . . . . . . . . . . . . 9–26

10 PRESTRESSED CONCRETE 10–1


10.1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10–1
10.1.1 Materials . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10–1
10.1.2 Prestressing Forces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10–4
10.1.3 Assumptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10–4
10.1.4 Tendon Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10–4
10.1.5 Equivalent Load . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10–4
10.1.6 Load Deformation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10–4
10.2 Flexural Stresses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10–6

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
0–4

E 10-1 Prestressed Concrete I Beam . . . . . . . . . . . . . . . . . . .


CONTENTS

. . . . . . 10–8
10.3 Case Study: Walnut Lane Bridge . . . . . . . . . . . . . . . . . . . . . . . . . . . 10–10
10.3.1 Cross-Section Properties . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10–12
10.3.2 Prestressing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10–12
10.3.3 Loads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10–13
10.3.4 Flexural Stresses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10–13

11 FOOTINGS 11–1

12 DEEP BEAMS 12–1

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft

List of Figures

1.1 Schematic Representation of Aggregate Gradation . . . . . . . . . . . . . . . . . 1–2


1.2 MicroCracks in Concrete under Compression . . . . . . . . . . . . . . . . . . . . 1–10
1.3 Concrete Stress Strain Curve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–11
1.4 Modulus of Rupture Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–11
1.5 Split Cylinder (Brazilian) Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–11
1.6 Biaxial Strength of Concrete . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–12
1.7 Time Dependent Strains in Concrete . . . . . . . . . . . . . . . . . . . . . . . . . 1–13

2.1 Strain Diagram Uncracked Section . . . . . . . . . . . . . . . . . . . . . . . . . . 2–1


2.2 Transformed Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2–2
2.3 Stress Diagram Cracked Elastic Section . . . . . . . . . . . . . . . . . . . . . . . 2–3
2.4 Desired Stress Distribution; WSD Method . . . . . . . . . . . . . . . . . . . . . . 2–4
2.5 Cracked Section, Limit State . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2–8
2.6 Whitney Stress Block . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2–10
2.7 Bar Spacing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2–15
2.8 T Beams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2–18
2.9 T Beam as Rectangular Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2–18
2.10 T Beam Strain and Stress Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . 2–18
2.11 Decomposition of Steel Reinforcement for T Beams . . . . . . . . . . . . . . . . . 2–19
2.12 Doubly Reinforced Beams; Strain and Stress Diagrams . . . . . . . . . . . . . . . 2–24
2.13 Different Possibilities for Doubly Reinforced Concrete Beams . . . . . . . . . . . 2–24
2.14 Strain Diagram, Doubly Reinforced Beam; is As Yielding? . . . . . . . . . . . . . 2–25
2.15 Strain Diagram, Doubly Reinforced Beam; is As Yielding? . . . . . . . . . . . . . 2–26
2.16 Summary of Conditions for top and Bottom Steel Yielding . . . . . . . . . . . . . 2–27
2.17 Bond and Development Length . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2–31
2.18 Actual Bond Distribution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2–32
2.19 Splitting Along Reinforcement . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2–32
2.20 Development Length . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2–33
2.21 Development Length . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2–33
2.22 Hooks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2–35
2.23 Bar cutoff requirements of the ACI code . . . . . . . . . . . . . . . . . . . . . . . 2–36
2.24 Standard cutoff or bend points for bars in approximately equal spans with uni-
formly distributed load . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2–37
2.25 Moment Capacity Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2–38

3.1 Principal Stresses in Beam . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3–1


3.2 Types of Shear Cracks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3–1
3.3 Shear Strength of Uncracked Section . . . . . . . . . . . . . . . . . . . . . . . . . 3–2
Draft
0–2

3.4 Mohr’s Circle for Shear Strength of Uncracked Section . . . . . . .


LIST OF FIGURES

. . . . . . . . 3–3
3.5 Shear Strength of Uncracked Section . . . . . . . . . . . . . . . . . . . . . . . . . 3–4
3.6 Free Body Diagram of a R/C Section with a Flexural Shear Crack . . . . . . . . 3–5
3.7 Equilibrium of Shear Forces in Cracked Section . . . . . . . . . . . . . . . . . . . 3–5
3.8 Summary of ACI Code Requirements for Shear . . . . . . . . . . . . . . . . . . . 3–7
3.9 Corbel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3–9
3.10 Shear Friction Mechanism . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3–9
3.11 Shear Friction Across Inclined Reinforcement . . . . . . . . . . . . . . . . . . . . 3–10

4.1 Continuous R/C Structures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4–1


4.2 Load Positioning on Continuous Beams . . . . . . . . . . . . . . . . . . . . . . . 4–1
4.3 ACI Approximate Moment Coefficients . . . . . . . . . . . . . . . . . . . . . . . . 4–3
4.4 Design Negative Moment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4–4
4.5 Moment Diagram of a Rigidly Connected Uniformly Loaded Beam . . . . . . . . 4–4
4.6 Moment Curvature of an Elastic-Plastic Section . . . . . . . . . . . . . . . . . . . 4–5
4.7 Plastic Moments in Uniformly Loaded Rigidly Connected Beam . . . . . . . . . . 4–5
4.8 Plastic Redistribution in Concrete Sections . . . . . . . . . . . . . . . . . . . . . 4–6
4.9 Block Diagram for R/C Building Design . . . . . . . . . . . . . . . . . . . . . . . 4–8

5.1 Crack Width Equation Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . 5–2


5.2 Uncracked Transformed and Cracked Transformed X Sections . . . . . . . . . . . 5–4
5.3 Time Dependent Deflection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5–5
5.4 Time Dependent Strain Distribution . . . . . . . . . . . . . . . . . . . . . . . . . 5–6
5.5 Short and long Term Deflections . . . . . . . . . . . . . . . . . . . . . . . . . . . 5–6

6.1 Approximate Analysis of Frames Subjected to Vertical Loads; Girder Moments . 6–2
6.2 Approximate Analysis of Frames Subjected to Vertical Loads; Column Axial Forces6–3
6.3 Approximate Analysis of Frames Subjected to Vertical Loads; Column Moments 6–3
6.4 Approximate Analysis of Frames Subjected to Lateral Loads; Column Shear . . . 6–5
6.5 Approximate Analysis of Frames Subjected to Lateral Loads; Girder Moment . . 6–5
6.6 Approximate Analysis of Frames Subjected to Lateral Loads; Column Axial Force6–6
6.7 Example; Approximate Analysis of a Building . . . . . . . . . . . . . . . . . . . . 6–7
6.8 Approximate Analysis of a Building; Moments Due to Vertical Loads . . . . . . . 6–9
6.9 Approximate Analysis of a Building; Shears Due to Vertical Loads . . . . . . . . 6–10
6.10 Approximate Analysis for Vertical Loads; Spread-Sheet Format . . . . . . . . . . 6–12
6.11 Approximate Analysis for Vertical Loads; Equations in Spread-Sheet . . . . . . . 6–13
6.12 Approximate Analysis of a Building; Moments Due to Lateral Loads . . . . . . . 6–14
6.13 Portal Method; Spread-Sheet Format . . . . . . . . . . . . . . . . . . . . . . . . . 6–16
6.14 Portal Method; Equations in Spread-Sheet . . . . . . . . . . . . . . . . . . . . . . 6–17

7.1 Types of Slabs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7–1


7.2 One vs Two way slabs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7–2
7.3 Load Distribution in Slabs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7–2
7.4 Load Transfer in R/C Buildings . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7–3

9.1 Types of columns . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9–1


9.2 Tied vs Spiral Reinforcement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9–2
9.3 Possible Bar arrangements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9–2
9.4 Sources of Bending . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9–3

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
LIST OF FIGURES

9.5 Load Moment Interaction Diagram . . . . . . . . . . . . . . . . . . . . . . . . .


0–3

. 9–4
9.6 Strain and Stress Diagram of a R/C Column . . . . . . . . . . . . . . . . . . . . 9–5
9.7 Column Interaction Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9–8
9.8 Failure Surface of a Biaxially Loaded Column . . . . . . . . . . . . . . . . . . . . 9–15
9.9 Load Contour at Plane of Constant Pn , and Nondimensionalized Corresponding
plots . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9–16
9.10 Biaxial Bending Interaction Relations in terms of β . . . . . . . . . . . . . . . . . 9–17
9.11 Bilinear Approximation for Load Contour Design of Biaxially Loaded Columns . 9–17
9.12 Euler Column . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9–19
9.13 Column Failures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9–20
9.14 Critical lengths of columns . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9–21
9.15 Effective length Factors Ψ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9–22
9.16 Standard Alignment Chart (ACI) . . . . . . . . . . . . . . . . . . . . . . . . . . . 9–23
9.17 Minimum Column Eccentricity . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9–23
9.18 P-M Magnification Interaction Diagram . . . . . . . . . . . . . . . . . . . . . . . 9–24

10.1 Pretensioned Prestressed Concrete Beam, (?) . . . . . . . . . . . . . . . . . . . . 10–2


10.2 Posttensioned Prestressed Concrete Beam, (?) . . . . . . . . . . . . . . . . . . . . 10–2
10.3 7 Wire Prestressing Tendon . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10–3
10.4 Alternative Schemes for Prestressing a Rectangular Concrete Beam, (?) . . . . . 10–5
10.5 Determination of Equivalent Loads . . . . . . . . . . . . . . . . . . . . . . . . . . 10–5
10.6 Load-Deflection Curve and Corresponding Internal Flexural Stresses for a Typi-
cal Prestressed Concrete Beam, (?) . . . . . . . . . . . . . . . . . . . . . . . . . . 10–6
10.7 Flexural Stress Distribution for a Beam with Variable Eccentricity; Maximum
Moment Section and Support Section, (?) . . . . . . . . . . . . . . . . . . . . . . 10–7
10.8 Walnut Lane Bridge, Plan View . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10–11
10.9 Walnut Lane Bridge, Cross Section . . . . . . . . . . . . . . . . . . . . . . . . . . 10–12

11.1 xxx . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11–1


11.2 xxx . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11–2
11.3 xxx . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11–2
11.4 xxx . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11–3
11.5 xxx . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11–3

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft

List of Tables

1.1 ASTM Sieve Designation’s Nominal Sizes Used for Concrete Aggregates . . . . . 1–3
1.2 ASTM C33 Grading Limits for Coarse Concrete Aggregates . . . . . . . . . . . . 1–3
1.3 ASTM C33 Grading Limits for Fine Concrete Aggregates . . . . . . . . . . . . . 1–3
1.4 Example of Fineness Modulus Determination for Fine Aggregate . . . . . . . . . 1–5
1.5 Recommended Slumps (inches) for Various Types of Construction . . . . . . . . 1–6
1.6 Recommended Average Total Air Content as % For Different Nominal Maximum
Sizes of Aggregates and Levels of Exposure . . . . . . . . . . . . . . . . . . . . . 1–6
1.7 Approximate Mixing Water Requirements, lb/yd3 of Concrete For Different
Slumps and Nominal Maximum Sizes of Aggregates . . . . . . . . . . . . . . . . . 1–7
1.8 Relationship Between Water/Cement Ratio and Compressive Strength . . . . . . 1–7
1.9 Volume of Dry-Rodded Coarse Aggregate per Unit Volume of Concrete for Dif-
ferent Fineness Moduli of Sand . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–8
1.10 Creep Coefficients . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–13
1.11 Properties of Reinforcing Bars . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–14
1.12 Strength Reduction Factors, Φ . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–14

2.1 Total areas for various numbers of reinforcing bars (inch2 ) . . . . . . . . . . . . . 2–14
2.2 Minimum Width (inches) according to ACI Code . . . . . . . . . . . . . . . . . . 2–14

4.1 Building Structural Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4–7

6.1 Columns Combined Approximate Vertical and Horizontal Loads . . . . . . . . . 6–18


6.2 Girders Combined Approximate Vertical and Horizontal Loads . . . . . . . . . . 6–19

7.1 Recommended Minimum Slab and Beam Depths . . . . . . . . . . . . . . . . . . 7–4


Draft
0–2 LIST OF TABLES

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
LIST OF TABLES

Tentative Schedule
0–3

Fall 1994
1 Aug. 28 Intro; Material
Aug. 30 Concrete mix design
2 Sep. 4 Elastic Uncracked
Sep. 6 WSD; USD singly reinforced
3 Sep. 11 USD singly, examples
Sep. 13 T Beams
4 Sep. 18 T Beams, Doubly Reinf
Sep. 20 Doubly Reinf Development length
5 Sep. 25 Shear
Sep. 27 Shear
6 Oct. 2 TP Lab
Oct. 4 Fall Break
7 Oct. 9 Crack width
Oct. 11 EXAM I
8 Oct. 16 Deflection
Oct. 18 Crack Width-Defelction
9 Oct. 23 Deflection, Continuous Systems
Oct. 25 Continuous Systems; One way slabs
10 Oct. 30 Columns; Intro
Nov. 1 Columns
11 Nov. 6 LAB
Nov. 8 Columns
12 Nov. 13 Biaxial bending
Nov. 15 Long column
13 Nov. 20 Lab
Nov. 22 Thanksgiving

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
0–4 LIST OF TABLES

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft

Chapter 1

INTRODUCTION

1.1 Material
1.1.1 Concrete
This section is adapted from Concrete by Mindess and Young, Prentice Hall, 1981

1.1.1.1 Mix Design


1.1.1.1.1 Constituents

1 Concrete is a mixture of Portland cement, water, and aggregates (usually sand and crushed

stone).
2 Portland cement is a mixture of calcareous and argillaceous materials which are calcined in
a kiln and then pulverized. When mixed with water, cement hardens through a process called
hydration.
3 Ideal mixture is one in which:

1. A minimum amount of cement-water paste is used to fill the interstices between the
particles of aggregates.

2. A minimum amount of water is provided to complete the chemical reaction with cement.
Strictly speaking, a water/cement ratio of about 0.25 is needed to complete this reaction,
but then the concrete will have a very low “workability”.

In such a mixture, about 3/4 of the volume is constituted by the aggregates, and the remaining
1/4 being the cement paste.
4 Smaller particles up to 1/4 in. in size are called fine aggregates, and the larger ones being

coarse aggregates.
5 Portland Cement has the following ASTM designation

I Normal

II Moderate sulfate resistant, moderate heat of hydration

III High early strength (but releases too much heat)


Draft
1–2

111
000
000 11
111 000
111
000 111
00111 000 11
00
00111
11 11
00
00
11 111
000
000 11
111
0
1 11
00
00
11
INTRODUCTION

00
11
00000 00
111
000 0000
1111
0000
1111 000 0000
1111
0000
1111 000
11100
11 0000
11110
1 000
111 0
1 0000
1111
00
11
0 1111
1 0000 0 1111
00
11 0000
000
111
000
111
0000 111
1111 000
0000
1111
0000
1111
0000
1111 000
111 00
11
000011
111100
111
000
111
000
111 000
111
0000
1111
0000
1111
0000
1111 11
1
0
0
1 000
111
000
111
0000
1111
000
111
000
111
000
111 00
11
001
110
0
1
0000
1111
0000
1111
0000
1111000 111
111 00
11
000
11
00
00
11
000
111
111
000
000
111
0000 111
1111 00
11
1
00
11
00
11
0000
1111
0000
1111
0000
1111
0000
1111
0000
1111
0001111
111 0000
1111
0000 0000
1111
000
111
0000
111100
11
00
11
000011
0001111
111 0000
1111
0000 0
1
00
11 000
111
0000
1111
000
111
0000
1111
000
11100
11
0000
1111
00
11 0000
1111
00
11
000
111
0
1 000
111
00
11
0000
1111
00
11
0000
1111
0001111
0
1 0000
1111
0000
0
1 0
1
00
11
0000
1111 0000
1111
0000
1111
0000
1111 0000
1111
000
111 00 0000
1111
0000
1111
0000
1111
001111
11 000
111
0000
1111
0000 1111
00 111
11 000
00000000
1111
0000
1111 00
11
000 111
00 1
0
000
0000
1111
0000 111000 0000
1111
0000
1111 0
1
00
11
111 111 00
11
0000 1111
1111 0000
0000
1111 1111 0000
1111
0000
1111 1111 0000
11110000
1111 11 0
1 1111 000
111 0000 1
1111 0
00
11
0000
1111
0000
1111
0000
1111
0000
1111
000
111
0000
1111
0000
1111
0000
1111
000000
11 00
11 00 111
11 000
0000
1111
0000
1111
0000
11110000
1111
0
1 000 000
111 00
11
0000
1111
000
111
000
111 0000
1111
00
11 11
00
0000
1111
0000
1111
0000
1111
0000 1111
1111 0000
0000
1111
0000
1111
0000
1111
0000
1111
0000
1111
0000 111
1111
00
11
000
000
111
000
111
0000
1111
0000
1111
0
1
0000
1111
0
1
0000
1111
0
1
0
1
0
1
00
11
00 1
11
0
1
0
1 000
111
0 111
1 000
000
111
0001
111
0
1
0
0000
1111
0000
1111
00
11
0000
1111
00
11
00
11
00
11
00
11
000
111
0
100
11
00
11
011
1
00
11
00 111
11 000
000
111
000
111
00
11
00
11
00011
00 111 000
111 00
11
0000
1111 0000
1111 0000
1111 0 111 0000
1111 00 111
0000 111
1111 000
000
111 0000
1111 000
111
0000 111
1111 000 000
111 0000
1111 000
111
000
111 000 0000
1111 000
111
000
111 000
000 1111
0000 000 0
1 0111
000
00010 00
11 00111
00000
11
0000
1111
111
000
111
000
111
0000
1111
0000
1111
111
0000111
000
000
111
000
111 00 11
11 00
000
111 1
0
1
0
0000
1111
0
1
11
00 000 111
111
000 1
111
000
111
0 111
1 000 000
0
1
0
1
111 0
1 11
00
11
00000
111
00
11
111
000 11 11
00
000 11
111
000
111
00 111
11 000 00
00
11
00
11
000
11100
11
0000
1111
0000
1111 0000
1111
0000
1111
0000
1111
1111
0000
1111000
111 0000
1111
0000
1111
0000
1111 00
11 0000
1111
0000
1111 00
11 00
11
0000
1111
00
11 000
111
0000
1111
0000
1111
000
111
000
111 000
111 0
1
000
111
0
1 11
00
0000
1111
0000
1111
0000
1111
0000
1111000
111
0000
1111
0000
1111
0000
1111
0000
1111
000
111 0000
1111
0000
1111
000
111
0000
1111
0000
1111
0000
1111
0000
1111
0000
1111
0000
1111000
111
000
111
000
111
000
111
0000
1111
0000
1111
0000
1111
0000
1111
0000
1111
0000
1111
0000
1111
0000
1111
0000
1111
0000
1111
0000
1111
0
1
0000
1111
0
1
0
1
00
11
0
1
00
11
000
111
000
111
000
111
0000
1111
0000
1111
0000
1111
0000
1111
0000
1111
0000
1111
0
1
0000
1111
0000
1111
0000
1111
0000
1111
00
11000
111
00111
11000
00 1
11
00
11 0
000
111
000
111
000
111
000
111
000
111
000111
111 000
0000
1111
0000
1111
0000
1111
00
11
0000
1111
0000
1111
0000
1111
0000
1111
0000
1111 0000
1111 0000
1111 0000
1111 0000
1111 0
1 000
111 00
11
0000
1111000
111
0000
1111
000
111 0000
1111 000
111
111
000 0000
1111
0000
1111
000
111
00111
11
0
1
000
111000
000
1110000
1111 01111
0000
0000
1111
1 1
0 00
11 0111
1
000
111000
000111
111 000 001111
0000
0000
1111
11 11
00
0000
1111 0000
1111 000
111 0000
1111 000
111 1 11
0000
111100 000
111 0000
1111 0
1
0000
1111
0000
1111 0000
1111
0000
1111 000
111
000
111
000
111 0000
1111
000
111
0000
1111 00
11 000
111
000
111 00
11
000 111
00
111
11
00 000
11 1111
0
0000
1
0
0000
1111
00 0
11 1 000
111
000
111 00
11
000
1111
0 00
11
1 1111
0 1
0
0000
1
0
0000
1111
000
111
0000
1111
0000
1111
0000
1111
0000
1111
0000
1111
0000
1111
000
111 111
000 111
000
000
111
0000
1111
000
111
0000
1111
0000
1111
000
111
0000
1111 00
11 000
111
11
00
1
0000
111 00
11
000 111
000
111
111
000
111 000
0000
1111
0
1
0000
1111
0
1 0
1 0
1
0
1
000
111
11
00
11
00000
111 11
00
000 11
111
000
111
000
111 00
11
0000
1111
00
11
0000
1111
0000
11 00
11
00
11
0000
1111 0001111
0000 0000
11110000
1111
00001111
0000 11111
000 0000
11110 1111
1 0000
0
1 1111
0000000
1111
00
1100
11 000
111
0000
1111
111
0000 111
1111 000 0000
1111
0000
1111 000 11
1110000
1111
0000
1111
1111
0000
11110000
1111
0000
1111 00111
11
1
0 00
11
00000
111
000
111
0000
1111
0000
1111 0000
1111
0
1
0000
1111
0
1
00 11
11
11
00 0
1
0 000
111
000
111
0000
1111
0000
1111 00111
11 00
11
000
111
000
0000 111
1111 000
000
111 0000
1111
0001111
0000 000 00
1110000
11110000
1111
0000
11110000
1111
00001111
00 111
11
0000 00000
1100
11000
111
000
111
0000
1111
0000
1111
00
11
0000
1111
0000
1111 0
1 00 00
11 0
1000
111
00
11
0000
1111
0000
1111
0
1
000
111
000
111
00
11
00 000 00
11 00
11
0000
1111
0000
1111 111 0000
1111 000
111
000
111 11110000
1111 000
111
00 11
11
000
111 00001111
1111
00 0000 0
1 000
111
000
1110
1 0000
1111
0
1 000
111
00
11
0000
1111
0000 1111
1111
0000
1111 0000
0000
1111
0000
1111
0000 1111
0000
000
111
11
00
11
000
111
000
111 000
111
0000
1111
000
111
0000
1111
000 1111
0000 000
111
000
111
000
111
000 1
111
000
111
00 1
11
0111
0
1 00
11
000
0
1
0
1
11
00
0 1111
0000
11
00
0000
1111
0000
1111
000
111
00
11
00
11
00011
111
000
111
0 1
1
00111
00
11 000
0
00
11
0
1
0
1
1
0
000
111
1
0
000
111
000
111
1111
0000 1111
1111 0000 0000
1111
0000
1111 00
11
000
111 111
000
111 00
11
0000
1111
0000
1111 000 111
111
000 1
111
000
000 1111
111
0111
000 0000
0000
1111 00
11
00011
111 00111
00
11
000
111
000 000
111
000
111
0000
1111
0000 1111
1111 0000
00
11
000
111
111 00
11
000 1111
0000
000
111
11
00
11
00 000
111
000
111
000 1111
111 0000
1
0
1
0 1
0
1
0
1
0
1
000
11 00
11
000
111
000 00
111 000
111
11 00
00
11 11
00
11

Figure 1.1: Schematic Representation of Aggregate Gradation

IV Low heat Portland cement, minimizes thermal cracking but must control initial temper-
ature

V Sulfate resistant (marine environment)

6 Aggregate usually occupy 70% to 80% of the volume of concrete. They are granular material

derived, for the most part, from natural rock, crushed stone, natural gravels and sands.
7 ASTM C33 (Standard Specifications for Concrete Aggregates) governs the types of rock which
can produce aggregates.
8 The shape can be rounded, irregular, angular, flaky, or elongated.
9 The surface texture can be glassy, smooth, granular, rough, crystalline or honeycombed.
10 The particle size distribution or grading of aggregates is very important as it determines
the amount of paste for a workable concrete, Fig. 1.1. Since cement is the most expensive
component, proper gradation is of paramount importance.
11The grading of an aggregate supply is determined by a sieve analysis. A representative
sample of the aggregate is passed through a stack of sieves aranged in order of decreasing size
opening of the sieve.
12 We divide aggregates in two categories

Coarse aggregate fraction is that retained on the No. 4 sieve, Table 1.1.

Fine aggregate fraction is that passing the No. 4 sieve.

13 ASTM C33 sets grading limits for coarse and fine aggregates, Table 1.2 and 1.3 respectively.
14If a concrete does not comply with these limits, than there will be a need for more paste,
and there will be the possibility of aggregate segregation.
15Since aggregates contain some porosity, water can be absorbed. Also water can be retained
on the surface of the particle as a film or moisture. Hence, it is necessary to quantify the
moisture content of the aggregates in order to make adjustments to the water. Because dry
aggregates will remove water from the paste, then the w/c is effectively reduced. On the other
hand moist aggregates may effectively increase the w/c ratio.

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
1.1 Material 1–3

ASTM Size
Design. mm in.
Coarse Aggregate
3 in. 75 3
21/2 in. 63 2.5
2 in. 50 2
11/2 in. 37.5 1.5
1 in. 25 1
3/4 in. 19 0.75
1/2 in. 12.5 0.50
3/8 in. 9.5 0.375
Fine Aggregate
No. 4 4.75 0.187
No. 8 2.36 0.0937
No. 16 1.18 0.0469
No. 30 0.60 (600 µm) 0.0234
No. 50 300 µm 0.0124
No. 100 150 µm 0.0059

Table 1.1: ASTM Sieve Designation’s Nominal Sizes Used for Concrete Aggregates

Sieve Size % (Nominal Maximum Size)


11/2 in. 1 in. 3/4 in. 1/2 in.
11/2 in. 95-100 100 - -
1 in. - 95-100 100 -
3/4 in. 35-70 - 90-100 100
1/2 in. - 25-60 - 90-100
3/8 in. 10-30 - 20-55 40-70
No. 4 0-5 0-10 0-10 0-15
No. 8 - 0-5 0-5 0-5

Table 1.2: ASTM C33 Grading Limits for Coarse Concrete Aggregates

Sieve Size % Passing


3/4 in. 100
No. 4 95-100
No. 8 80-100
No. 16 50-85
No. 30 25-60
No. 50 10-30
No. 100 2-10

Table 1.3: ASTM C33 Grading Limits for Fine Concrete Aggregates

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
1–4

16 Moisture states are defined as


INTRODUCTION

Oven-dry (OD): all moisture is removed from the aggregate.

Air-dry (AD): all moisture is removed from the surface, but internal pores are partially full.

Saturated-surface-dry (SSD): All pores are filled with water, but no film of water on the
surface.

Wet: All pores are completely filled with a film of water on the surface.

17 Based on the above, we can determine

Absorption capacity (AC): is the maximum amount of water the aggregate can absorb

WSSD − WOD
AC = × 100% (1.1)
WOD

most normal -weight aggregates (fine and coarse) have an absorption capacity in the range
of 1% to 2%.

Surface Moisture (SM): is the water in excess of the SSD state

WW et − WSSD
SM = × 100% (1.2)
WSSD

18 The fineness modulus is a parameter which describe the grading curve and it can be used
to check the uniformity of the grading. It is usually computed for fine aggregates on the basis
of 
cumulative percent retained on standard sieves
F.M. = (1.3)
100
where the standard sieves used are No. 100, No. 50, No. 30, No. 16, No. 8, and No. 4, and
3/8 in, 3/4 in, 11/2 in and larger.
19 The fineness modulus for fine aggregate should lie between 2.3 and 3.1 A small number
indicates a fine grading, whereas a large number indicates a coarse material.
20 Table 1.4 illustrates the determination of the fineness modulus.
21 Fineness modulus of fine aggregate is required for mix proportioning since sand gradation
has the largest effect on workability. A fine sand (low fineness modulus) has much higher paste
requirements for good workability.
22 The fineness modulus of coarse aggregate is not used for mix design purposes.
23 no-fines concrete has little cohesiveness in the frsh state and can not be compacted to a
void-free condition. Hence, it will have a low strength, high permeability. Its only advantage is
low density, and high thermal insulation which can be used if structural requirements are not
high.

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
1.1 Material

Sieve Weight Amount Cumulative Cumulative


1–5

Size Retained Retained Amount Amount


(g) (wt. %) Retained (%) Passing (%)
No. 4 9 2 2 98
No. 8 46 9 11 89
No. 16 97 19 30 70
No. 30 99 20 50 50
No. 50 120 24 74 26
No. 100 91 18 92 8

= 259
Fineness modulus=259/100=2.59

Table 1.4: Example of Fineness Modulus Determination for Fine Aggregate

1.1.1.1.2 Preliminary Considerations

24 There are two fundamental aspects to mix design to keep in mind:

1. Water/Cement ratio: where the strength in inversely proportional to the water to cement
ratio, approximately expressed as:
A
fc = (1.4)
B 1.5w/c
For fc in psi, A is usually taken as 14,000 and B depends on the type of cement, but may
be taken to be about 4. It should be noted that w/c controls not only the strength, but
also the porosity and hence the durability.

2. Aggregate Grading: In order to minimize the amount of cement paste, we must maximize
the volume of aggregates. This can be achieved through proper packing of the granular
material. The “ideal” grading curve (with minimum voids) is closely approximated by
the Fuller curve  q
d
Pt = (1.5)
D
where Pt is the fraction of total solids finer than size d, and D is the maximum particle
size, q is generally taken as 1/2, hence the parabolic grading.

1.1.1.1.3 Mix procedure

25Before starting the mix design process, the following material properties should be deter-
mined:

1. Sieve analysis of both fine and coarse aggregates

2. Unit weight of the coarse aggregate

3. bulk specific gravities

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
1–6

4. absorption capacities of the aggregates


INTRODUCTION

1. Slump1 must be selected for the particular job to account for the anticipated method
of handling and placing concrete, Table 1.5 As a general rule, adopt the lowest possible

Type of Construction Max Min


Foundation walls and footings 3 1
Plain footings, caissons 3 1
Beams and reinforced walls 4 1
Building columns 4 1
Pavement and slabs 3 1
Mass concrete 3 1

Table 1.5: Recommended Slumps (inches) for Various Types of Construction

slump.

2. Maximum aggregate size: in general the largest possible size should be adopted.
However, it should be noted that:

(a) For reinforced concrete, the maximum size may not exceed one-fifth of the mini-
mum dimensions between the forms, or three-fourths of the minimum clear spacing
between bars, or between steel and forms.
(b) For slabs on grade, the maximum size may not exceed one-third the slab depth.

In general maximum aggregate size is 3/4 in or 1 in.

3. Water and Air content Air content will affect workability (some time it is better to
increase air content rather than increasing w/c which will decrease strength). Air content
can be increased through the addition of admixtures. Table 1.6 tabulates recommended
values of air content (obtained through such admixtures) for different conditions (for
instance under severe freezing/thawing air content should be high).
Recommended water requirements are given by Table 1.7.

Sizes of Aggregates
Exposure 3/8 in. 1/2 in. 3/4 in. 1 in. 11/2 in.
Mild 4.5 4.0 3.5 3.5 3.0
Moderate 6.0 5.5 5.0 4.5 4.4
Extreme 7.5 7.0 6.0 6.05 5.5

Table 1.6: Recommended Average Total Air Content as % For Different Nominal Maximum
Sizes of Aggregates and Levels of Exposure

1
The slump test (ASTM C143) is a measure of the shear resistance of concrete to flowing under its own weight.
It is a good indicator of the concrete “workability”. A hollow mold in the form of a frustum of a cone is filled
with concrete in three layers of equal volume. Each layer is rodded 25 times. The mold is then lifted vertically,
and the slump is measured by determining the difference between the height of the mold and the height of the
concrete over the original center of the base of the specimen.

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
1.1 Material

Slump Sizes of Aggregates


1–7

in. 3/8 in. 1/2 in. 3/4 in. 1 in. 11/2 in.
Non-Air-Entrained Concrete
1-2 350 335 315 300 275
3-4 385 365 340 325 300
6-7 410 385 360 340 315
Air-Entrained Concrete
1-2 305 295 280 270 250
3-4 340 325 305 295 275
6-7 365 345 325 310 290

Table 1.7: Approximate Mixing Water Requirements, lb/yd3 of Concrete For Different Slumps
and Nominal Maximum Sizes of Aggregates

4. Water/cement ratio: this is governed by both strength and durability. Table 1.8
provides some guidance in terms of strength.

28 days w/c Ratio by Weight


fc Non-air-entrained Air-entrained
6,000 0.41 -
5,000 0.48 0.40
4,000 0.57 0.48
3,000 0.68 0.59
2,000 0.82 0.74

Table 1.8: Relationship Between Water/Cement Ratio and Compressive Strength

For durability, if there is a severe exposure (freeze/thaw, exposure to sea-water, sulfates),


then there are severe restrictions on the W/C ratio (usually to be kept just under 0.5)

5. Cement Content: Once the water content and the w/c ratio are determined, the amount
of cement per unit volume of concrete is determined simply by dividing the estimated
water requirement by the w/c ratio.

6. Coarse Aggregate Content: Volume of coarse aggregate required per cubic yard of
concrete depends on its maximum size and the fineness modulus of the fine aggregate,
Table 1.9. The oven dry (OD) volume of coarse aggregate in ft3 required per cubic yard
is simply equal to the value from Table 1.9 multiplied by 27. This volume can then be
converted to an OD weight by multiplying it by the dry-rodded2 weight per cubic foot of
coarse aggregate.

7. The fine aggregate content can be estimated by subtracting the volume of cement,
water, air and coarse aggregate from the total volume. The weight of the fine aggregate
can then be obtained by multiplying this volume by the density of the fine aggregate.
2
Dry Rodded volume (DRV) is the normal volume of space a material occupies.

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
1–8

Agg. Size Sand Fineness Moduli


INTRODUCTION

in 2.40 2.60 2.80 3.00


3/8 0.50 0.48 0.46 0.44
1/2 0.59 0.57 0.55 0.53
3/4 0.66 0.64 0.62 0.60
1 0.71 0.69 0.67 0.65
11/2 0.76 0.74 0.72 0.70

Table 1.9: Volume of Dry-Rodded Coarse Aggregate per Unit Volume of Concrete for Different
Fineness Moduli of Sand

8. Adjustment for moisture in the aggregates: is necessary. If aggregates are air


dry, they will absorb some water (thus effectively lowering the w/c), or if aggregates are
too wet they will release water (increasing the w/c and the workability but reducing the
strength).

1.1.1.1.4 Mix Design Example

Concrete is required for an exterior column to be located above ground in an area where
substantial freezing and thawing may occur. The concrete is required to have an average 28-
day compressive strength of 5,000 psi. For the conditions of placement, the slump should be
between 1 and 2 in, the maximum aggregate size should not exceed 3/4 in. and the properties
of the materials are as follows:

Cement: Type I specific gravity = 3.15

Coarse Aggregates: Bulk specific gravity (SSD) = 2.70; absorption capacity= 1.0%; Total
moisture content = 2.5%; Dry-rodded unit weight = 100 lb/ft3

Fine Aggregates: Bulk specific gravity (SSD) = 2.65; absorption capacity = 1.3 %; Total
moisture content=5.5%; fineness modulus = 2.70

The sieve analyses of both the coarse and fine aggregates fall within the specified limits. With
this information, the mix design can proceed:

1. Choice of slump is consistent with Table 1.5.

2. Maximum aggregate size (3/4 in) is governed by reinforcing details.

3. Estimation of mixing water: Because water will be exposed to freeze and thaw, it must
be air-entrained. From Table 1.6 the air content recommended for extreme exposure is
6.0%, and from Table 1.7 the water requirement is 280 lb/yd3

4. From Table 1.8, the water to cement ratio estimate is 0.4

5. Cement content, based on steps 4 and 5 is 280/0.4=700 lb/yd3

6. Coarse aggregate content, interpolating from Table 1.9 for the fineness modulus of
the fine aggregate of 2.70, the volume of dry-rodded coarse aggregate per unit volume of
concrete is 0.63. Therefore, the coarse aggregate will occupy 0.63 × 27 = 17.01 ft3 /yd3 .

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
1.1 Material

The OD weight of the coarse aggregate is 17.01 × 100 = 1, 701 lb. The SSD weight is
1–9

1, 701 × 1.01 = 1, 718 lb.

7. Fine aggregate content Knowing the weights and specific gravities of the water, cement,
and coarse aggregate, and knowing the air volume, we can calculate the volume per yd3
occupied by the different ingredients.
Water 280/62.4 = 4.49 ft3
Cement 700/(3.15)(62.4) = 3.56 ft3
Coarse Aggregate (SSD) 1,718/(2.70)(62.4) = 1.62 ft3
Air (0.06)(27) = 1.62 ft3
19.87 ft3
Hence, the fine aggregate must occupy a volume of 27.0 − 19.87 = 7.13 ft3 . The required
SSD weight of the fine aggregate is 7.13 × 2.65 × 62.4 = 1, 179 lb.

8. Adjustment for moisture in the aggregate. Since the aggregate will be neither SSD or
OD in the field, it is necessary to adjust the aggregate weights for the amount of water
contained in the aggregate. Only surface water need be considered; absorbed water does
not become part of the mix water. For the given moisture contents, the adjusted aggre-
gate weights become:

Coarse aggregate (wet)=1,718(1.025-0.01) = 1,744 lb/yd3


Fine aggregate (wet)=1,179(1.055-0.013) = 1,229 lb/yd3

Surface moisture contributed by the coarse aggregate is 2.5-1.0 = 1.5%; by the fine ag-
gregate: 5.5-1.3 = 4.2%; Hence the additional water required is then
280-1,718(0.015)-1,179(0.042) = 205 lb/yd3 .

Thus, the estimated batch weight per yd3 are

Water 205 lb
Cement 700 lb
Wet coarse aggregate 1,744 lb
Wet fine aggregate 1,229 lb
3,878 lb/yd3
3,878
27 143.6 lb/ft3

1.1.1.2 Mechanical Properties

26 Contrarily to steel to modulus of elasticity of concrete depends on the strength and is given
by

E = 57, 000 fc (1.6)

or

E = 33γ 1.5 fc (1.7)

where both fc and E are in psi and γ is in lbs/ft3 .

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
1–10

27
INTRODUCTION

Normal weight and lightweight concrete have γ equal to 150 and 90-120 lb/ft3 respectively.
28 Poisson’s ratio ν = 0.15.
29Typical concrete (compressive) strengths range from 3,000 to 6,000 psi; However high strength
concrete can go up to 14,000 psi.
30 Stress-strain curve depends on

1. Properties of aggregates

2. Properties of cement

3. Water/cement ratio

4. Strength

5. Age of concrete

6. Rate of loading, as rate, strength 

31 Non-linear part of stress-strain curve is caused by micro-cracking around the aggregates, Fig.
1.2

f’
c

Non-Linear

~ 0.5 cf’

Linear

εu

Figure 1.2: MicroCracks in Concrete under Compression

32 Irrespective of fc , maximum strain under compression is ≈ 0.003, Fig. 1.3


33 Full strength of concrete is achieved in about 28 days

 t
fct = f
4.0 + .85t c,28
or
t (days) 1 2 4 7 10 15

%fc,28 20 35 54 70 80 90

34 Concrete always gain strength in time, but a decreasing rate

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
1.1 Material

σ
1–11

f’
c

f’ / 2
c

εu = 0.003 ε

Figure 1.3: Concrete Stress Strain Curve

35 The tensile strength of concrete ft is very difficult to measure experimentally. Accepted
values

ft ≈ 0.07 − 0.11fc (1.8-a)



≈ 3 − 5 fc (1.8-b)

36 Rather than the tensile strength, it is common to measure the modulus of rupture fr , Fig.
1.4

11
00
00
11 11
00
00
11 00
11
00
11

Figure 1.4: Modulus of Rupture Test

σ
σ

Figure 1.5: Split Cylinder (Brazilian) Test


fr ≈ 7.5 fc (1.9)

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
1–12

f’t
INTRODUCTION

f’c
1

f’t
σ2

σ1 σ1

σ2

f’c

~ 20% increase in strength


2

Figure 1.6: Biaxial Strength of Concrete



37 Using split cylinder (or brazilian test), Fig. 1.5 ft ≈ 6−8 fc . For this test, a nearly uniform
tensile stress
2P
σ=
πdt
where P is the applied compressive load at failure, d and t are diameter and thickness of the
specimen respectively.
38 In most cases, concrete is subjected to uniaxial stresses, but it is possible to have biaxial
(shells, shear walls) or triaxial (beam/column connections) states of stress.
39 Biaxial strength curve is shown in Fig. 1.6
40 Concrete has also some time-dependent properties
Shrinkage: when exposed to air (dry), water tends to evaporate from the concrete surface, ⇒
shrinkage. It depends on the w/c and relative humidity. εsh ≈ 0.0002 − 0.0007. Shrinkage
can cause cracking if the structure is restrained, and may cause large secondary stresses.
If a simply supported beam is fully restrained against longitudinal deformation, then
σsh = Eεsh
√ 3, 000
= 57, 000 3, 000(0.0002) = 624 psi >
 10
 
ft

if the concrete is restrained, then cracking will occur3 .


Creep: can be viewed as the “squeezing” out of water due to long term stresses (analogous to
consolidation in clay), Fig. 1.7.
Creep coefficient, Table 1.10
εci ≈ 2 −
εct
Cu = 3
t0.6
Ct = C
10+t0.6 u

3
For this reason a minimum amount of reinforcement is always necessary in concrete, and a 2% reinforcement,
can reduce the shrinkage by 75%.

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
1.1 Material

ε
1–13

Elastic recovery
creep
Creep recovery

Residual

no load constant load no load

Figure 1.7: Time Dependent Strains in Concrete

fc 3,000 4,000 6,000 8,000


Cu 3.1 2.9 2.4 2.0

Table 1.10: Creep Coefficients

41 Coefficient of thermal expansion is 0.65 × 10−5 /deg F for normal weight concrete.

1.1.2 Reinforcing Steel

42 Steel is used as reinforcing bars in concrete, Table 1.11.


43Bars have a deformation on their surface to increase the bond with concrete, and usually
have a yield stress of 60 ksi.
44 Maximum allowable fy is 80 ksi.
45 Stirrups, used as vertical reinforcement to resist shear, usually have a yield stress of only 40
ksi
46Steel loses its strength rapidly above 700 deg. F (and thus must be properly protected from
fire), and becomes brittle at −30 deg. F
47 Prestressing Steel cables have an ultimate strength up to 270 ksi.
48 Welded wire fabric is often used to reinforce slabs and shells. It has both longitudinal and
transverse cold-drawn steel. They are designated by A×A−W B ×B, such as 6×6−W 1.4×1.4
where spacing of the wire is 6 inch, and a cross section of 0.014 in2 .

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
1–14

Bar Designation Diameter Area Perimeter


INTRODUCTION

Weight
(in.) ( in2 ) in lb/ft
No. 2 2/8=0.250 0.05 0.79 0.167
No. 3 3/8=0.375 0.11 1.18 0.376
No. 4 4/8=0.500 0.20 1.57 0.668
No. 5 5/8=0.625 0.31 1.96 1.043
No. 6 6/8=0.750 0.44 2.36 1.5202
No. 7 7/8=0.875 0.60 2.75 2.044
No. 8 8/8=1.000 0.79 3.14 2.670
No. 9 9/8=1.128 1.00 3.54 3.400
No. 10 10/8=1.270 1.27 3.99 4.303
No. 11 11/8=1.410 1.56 4.43 5.313
No. 14 14/8 =1.693 2.25 5.32 7.650
No. 18 18/8 =2.257 4.00 7.09 13.60

Table 1.11: Properties of Reinforcing Bars

1.2 Design Philosophy, USD

49ACI refers to this method as the Strength Design Method, (previously referred to as the
Ultimate Strength Method).

ΦRn ≥ Σαi Qi (1.10)

where

Φ is a strength reduction factor, less than 1, and must account for the type of structural
element, Table 1.12 (ACI 9.3.2)

Type of Member Φ
Axial Tension 0.9
Flexure 0.9
Axial Compression, spiral reinforcement 0.75
Axial Compression, other 0.70
Shear and Torsion 0.85
Bearing on concrete 0.70

Table 1.12: Strength Reduction Factors, Φ

Rn is the nominal resistance (or strength).

Ru = Rd = ΦRn is the design strength.

αi is the load factor corresponding to Qi and is greater than 1.

Σαi Qi is the required strength based on the factored load:

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
1.3 Analysis vs Design

i is the type of load


1–15

ΦMn ≥ Mu
ΦVn ≥ Vu
ΦPn ≥ Pu

50 Note that the subscript d and u are equivalent.


51 The various factored load combinations which must be considered (ACI: 9.2) are

1. 1.4D+1.7L

2. 0.75(1.4D+1.7L+1.7W)

3. 0.9D+1.3W

4. 1.05D+1.275W

5. 0.9D+1.7H

6. 1.4D +1.7L+1.7H

7. 0.75(1.4D+1.4T+1.7L)

8. 1.4(D+T)

where D= dead; L= live; Lr= roof live; W= wind; E= earthquake; S= snow; T= temperature;
H= soil. We must select the one with the largest limit state load.
52 Serviceability Limit States must be assessed under service loads (not factored). The

most important ones being

1. Deflections

2. Crack width (for R/C)

3. Stability

1.3 Analysis vs Design

53 In R/C we always consider one of the following problems:

Analysis: Given a certain design, determine what is the maximum moment which can be
applied.

Design: Given an external moment to be resisted, determine cross sectional dimensions (b and
h) as well as reinforcement (As ). Note that in many cases the external dimensions of the
beam (b and h) are fixed by the architect.

54 We often consider the maximum moment along a member, and design accordingly.

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
1–16

1.4 Basic Relations and Assumptions


INTRODUCTION

55 In developing a design/analysis method for reinforced concrete, the following basic relations
will be used:
1. Equilibrium: of forces and moment at the cross section. 1) ΣFx = 0 or Tension in the
reinforcement = Compression in concrete; and 2) ΣM = 0 or external moment (that is the
one obtained from the moment envelope) equal and opposite to the internal one (tension
in steel and compression of the concrete).

2. Material Stress Strain: We recall that all normal strength concrete have a failure strain
#u = .003 in compression irrespective of fc .

56 Basic assumptions used:


Compatibility of Displacements: Perfect bond between steel and concrete (no slip). Note
that those two materials do also have very close coefficients of thermal expansion under
normal temperature.

Plane section remain plane ⇒ strain is proportional to distance from neutral axis.

Neglect tensile strength in all cases.

1.5 ACI Code


Attached is an unauthorized copy of some of the most relevant ACI-318-89 design code provi-
sions.
8.1.1 - In design of reinforced concrete structures, members shall be proportioned for ad-
equate strength in accordance with provisions of this code, using load factors and strength
reduction factors Φ specified in Chapter 9.
8.3.1 - All members of frames or continuous construction shall be designed for the maximum
effects of factored loads as determined by the theory of elastic analysis, except as modified
according to Section 8.4. Simplifying assumptions of Section 8.6 through  8.9 may be used.
8.5.1 - Modulus of elasticity Ec for concrete may be taken as Wc1.5 33 fc ( psi) for values
of Wc  between 90 and 155 lb per cu ft. For normal weight concrete, Ec may be taken as
57, 000 fc .
8.5.2 - Modulus of elasticity Es for non-prestressed reinforcement may be taken as 29,000
psi.
9.1.1 - Structures and structural members shall be designed to have design strengths at all
sections at least equal to the required strengths calculated for the factored loads and forces in
such combinations as are stipulated in this code.
9.2 - Required Strength
9.2.1 - Required strength U to resist dead load D and live load L shall be at least equal to

U = 1.4D + 1.7L

9.2.2 - If resistance to structural effects of a specified wind load W are included in design,
the following combinations of D, L, and W shall be investigated to determine the greatest
required strength U
U = 0.75(1.4D + 1.7L + 1.7W )

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
1.5 ACI Code 1–17

where load combinations shall include both full value and zero value of L to determine the more
severe condition, and
U = 0.9D + 1.3W
but for any combination of D, L, and W, required strength U shall not be less than Eq. (9-1).
9.3.1 - Design strength provided by a member, its connections to other members, and its
cross sections, in terms of flexure, axial load, shear, and torsion, shall be taken as the nominal
strength calculated in accordance with requirements and assumptions of this code, multiplied
by a strength reduction factor Φ.
9.3.2 - Strength reduction factor Φ shall be as follows:
9.3.2.1 - Flexure, without axial load 0.90
9.4 - Design strength for reinforcement Designs shall not be based on a yield strength of
reinforcement fy in excess of 80,000 psi, except for prestressing tendons.
10.2.2 - Strain in reinforcement and concrete shall be assumed directly proportional to
the distance from the neutral axis, except, for deep flexural members with overall depth to
clear span ratios greater than 2/5 for continuous spans and 4/5 for simple spans, a non-linear
distribution of strain shall be considered. See Section 10.7.
10.2.3 - Maximum usable strain at extreme concrete compression fiber shall be assumed
equal to 0.003.
10.2.4 - Stress in reinforcement below specified yield strength fy for grade of reinforcement
used shall be taken as Es times steel strain. For strains greater than that corresponding to fy ,
stress in reinforcement shall be considered independent of strain and equal to fy .
10.2.5 - Tensile strength of concrete shall be neglected in flexural calculations of reinforced
concrete, except when meeting requirements of Section 18.4.
10.2.6 - Relationship between concrete compressive stress distribution and concrete strain
may be assumed to be rectangular, trapezoidal, parabolic, or any other shape that results in
prediction of strength in substantial agreement with results of comprehensive tests.
10.2.7 - Requirements of Section 10.2.5 may be considered satisfied by an equivalent rect-
angular concrete stress distribution defined by the following:
10.2.7.1 - Concrete stress of 0.85fc shall be assumed uniformly distributed over an equiva-
lent compression zone bounded by edges of the cross section and a straight line located parallel
to the neutral axis at a distance (a = β1 c) from the fiber of maximum compressive strain.
10.2.7.2 - Distance c from fiber of maximum strain to the neutral axis shall be measured
in a direction perpendicular to that axis.
10.2.7.3 - Factor β1 shall be taken as 0.85 for concrete strengths fc up to and including
4,000 psi. For strengths above 4,000 psi, β1 shall be reduced continuously at a rate of 0.05 for
each 1000 psi of strength in excess of 4,000 psi, but β1 shall not be taken less than 0.65.
10.3.2 - Balanced strain conditions exist at a cross section when tension reinforcement
reaches the strain corresponding to its specified yield strength fy just as concrete in compression
reaches its assumed ultimate strain of 0.003.
10.3.3 - For flexural members, and for members subject to combined flexure and compres-
sive axial load when the design axial load strength (ΦPn ) is less than the smaller of (0.10fc Ag )
or (ΦPb ), the ratio of reinforcement p provided shall not exceed 0.75 of the ratio ρb that would
produce balanced strain conditions for the section under flexure without axial load. For mem-
bers with compression reinforcement, the portion of ρb equalized by compression reinforcement
need not be reduced by the 0.75 factor.
10.3.4 - Compression reinforcement in conjunction with additional tension reinforcement
may be used to increase the strength of flexural members.

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
1–18 INTRODUCTION

10.5.1 - At any section of a flexural member, except as provided in Sections 10.5.2 and
10.5.3, where positive reinforcement is required by analysis, the ratio ρ provided shall not be
less than that given by
200
ρmin =
fy

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft

Chapter 2

FLEXURE

1 This is probably the longest chapter in the notes, we shall cover in great details flexural
design/analysis of R/C beams starting with uncracked section to failure conditions.

1. Uncracked elastic (uneconomical)

2. cracked elastic (service stage)

3. Ultimate (failure)

2.1 Uncracked Section


εc

h d

As
εs

Figure 2.1: Strain Diagram Uncracked Section

2 Assuming perfect bond between steel and concrete, we have εs = εc Fig. 2.1
fs fc Es
ε s = εc ⇒ = ⇒ fs = fc ⇒ fs = nfc (2.1)
Es Ec Ec
Es
where n is the modular ratio n = Ec

3 Tensile force in steel Ts = As fs = As nfc


4 Replace steel by an equivalent area of concrete, Fig. 2.2.
Draft
2–2

11111111111111111
00000000000000000
00000000000000000
11111111111111111
FLEXURE

00000000000000000
11111111111111111
00000000000000000
11111111111111111
00000000000000000
11111111111111111
00000000000000000
11111111111111111
00000000000000000
11111111111111111
00000000000000000
11111111111111111
00000000000000000
11111111111111111
(n-1)A S 11111111111111111
00000000000000000
00000000000000000
11111111111111111 (n-1)A S
00000000000000000
11111111111111111
2 00000000000000000
11111111111111111
00000000000000000
11111111111111111 2
00000000000000000
11111111111111111

Figure 2.2: Transformed Section

5 Homogeneous section & under bending


Mc
fc = ⇒ fs = nfc (2.2)
I

6
+
Make sure that σmax < ft

Example 2-1: Uncracked Section

Given fc = 4,000 psi; ft = 475 psi; fy = 60,000 psi; M = 45 ft-k = 540,000 in-lb; As = 2.35
in2
+ , f − , and f
Determine fmax max s

yt
25" 23"

2
yb
As = 2.35 in

10"

Solution:

29, 000
n = √ = 8 ⇒ (n − 1)As = (8 − 1)(2.35) = 16.45 in2 (2.3-a)
57 4, 000
(10)(25)( 25
2 ) + (16.45)(2)
yb = (2.3-b)
(25)(10) + 16.45
yb = 11.8 in (2.3-c)
y t = 25 − 11.8 = 13.2 in (2.3-d)
(10)(25)3
I = + (25)(10)(13.2 − 12.5)2 + (16.45)(23 − 13.2)2 (2.3-e)
12
= 14, 722 in2 (2.3-f)
Mc (540, 000) lb.in(13.2)in
fcc = = = 484 psi (2.3-g)
I (14, 722) in4

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
2.2 Section Cracked, Stresses Elastic

Mc (540, 000) lb.in(25 − 13.2) in √


2–3

fct = = 4
= 433 psi < 475 psi (2.3-h)
I (14, 722) in
Mc (540, 000)(23 − 13.2) in
fs = n = (8) = 2, 876 psi (2.3-i)
I (14, 722)

2.2 Section Cracked, Stresses Elastic

7 This is important not only as an acceptable alternative ACI design method, but also for the

later evaluation of crack width under service loads.

2.2.1 Basic Relations

8If fct > fr , fcc <≈ .5fc and fs < fy we will assume that the crack goes all the way to the
N.A and we will use the transformed section, Fig. 2.3
fc
11111111111111111
00000000000000000 111111111
000000000
00000000000000000
11111111111111111 000000000
111111111 kd/3
00000000000000000
11111111111111111 000000000
111111111 C
00000000000000000
11111111111111111 000000000
111111111 kd
00000000000000000
11111111111111111 000000000
111111111
00000000000000000
11111111111111111 000000000
111111111 d
00000000000000000
11111111111111111 000000000
111111111
00000000000000000
11111111111111111 000000000
111111111 (1-k/3)d=jd
00000000000000000
11111111111111111
(n-1)A S 11111111111111111
00000000000000000
00000000000000000
11111111111111111 (n-1)A S
00000000000000000
11111111111111111 11111111111111111
00000000000000000 T
00000000000000000
11111111111111111 00000000000000000
11111111111111111
2
00000000000000000
11111111111111111 2
00000000000000000
11111111111111111
00000000000000000
11111111111111111
b

Figure 2.3: Stress Diagram Cracked Elastic Section

9 To locate N.A, tension force = compressive force (by def. NA) (Note, for linear stress distri-

bution and with ΣFx = 0; σ = by ⇒ bydA = 0, thus b ydA = 0 and ydA = yA = 0, by
definition, gives the location of the neutral axis)


Es
10 Note, N.A. location depends only on geometry & n
Ec

11 Tensile and compressive forces are equal to C = bkd 2 fc & T = As fs and neutral axis is
determined by equating the moment of the tension area to the moment of the compression
area
 
kd
b(kd) = nAs (d − kd) 2nd degree equation (2.4-a)
2
M
M = T jd = As fs jd ⇒ fs (2.4-b)
As jd
bkd bd2 M
M = Cjd = fc jd = kjfc ⇒ fc = 1 2 (2.4-c)
2 2 2 bd kj

where j = (1 − k/3).

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
2–4

2.2.2 Working Stress Method


FLEXURE

12 Referred to as Alternate Design Method (ACI Code Appendix A); Based on Working
Stress Design method.
13 Places a limit on stresses and uses service loads (ACI A.3).

fcc ≤ .45fc
fst ≤ 20 ksi for grade 40 or 50 steel (2.5)
fst ≤ 24 ksi for grade 60 steel

14 Location of neutral axis depends on whether we are analysing or designing a section.

Review: We seek to locate the N.A by taking the first moments:



ρ = Abds  
⇒ k = 2ρn + (ρn)2 − ρn (2.6-a)

b(kd) (kd)
2 = nAs (d − kd)

Design: Objective is to have fc & fs preset & determine As , Fig. 2.4, and we thus seek the
optimal value of k in such a way that concrete and steel reach their respective limits
simultaneously.
εc fc

C kd/3
kd
d
(1-k/3)d=jd

T
εs fs

Figure 2.4: Desired Stress Distribution; WSD Method


 
εc
= kd  

εs d−kd  f c Es
= k 
fc Ec f s 1−k n
εc = Es k= (2.7)
Ec 
 n = 

n+r
εs = fs
Es
Ec
fs 

r = fc

15 Balanced design in terms of ρ: What is the value of ρ such that steel and concrete will both

reach their maximum allowable stress values simultaneously


C = bkd
2 fc 
 
 fc
T = As fs 2 bkd = ρb fs bd n
ρb = (2.8-a)
C = T 

n
k = n+r 2r(n+r)

ρ = Abds
Victor Saouma Mechanics and Design of Reinforced Concrete
Draft
2.2 Section Cracked, Stresses Elastic 2–5

16 Governing equations

Review Start by determining ρ,

• If ρ < ρb steel reaches max. allowable value before concrete, and

M = As fs jd (2.9)

• If ρ > ρb concrete reaches max. allowable value before steel and


bkd
M = fc jd (2.10)
2
or
1
M = fc jkbd2 = Rbd2 (2.11)
2

where

k = 2ρn + (ρn)2 − ρn

Design We define
1
R = fc kj (2.12)
2
solve for bd2 from
M
bd2 = (2.13)
R
assume b and solve for d. Finally we can determine As from

As = ρb bd (2.14)

17 Summary

Review Design
√ √
b, d, As M
M? b, d, As ?
ρ = Abds k = n+r n

 j = 1 − k3
k = 2ρn + (ρn)2 − ρn r = ffsc
r = ffsc R = 12 fc kj
n n
ρb = 2r(n+r) ρb = 2r(n+r)
ρ < ρb M = As fs jd bd2 = M R
ρ > ρb M = 12 fc bkd2 j As = ρb bd or As = M
fs jd

Example 2-2: Cracked Elastic Section

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
2–6

Same problem as example 2.1 fc = 4,000 psi; ft = 475 psi; fy = 60,000 psi; As = 2.35 in2
FLEXURE

however, M is doubled to M = 90 k.ft (instead of 45).


Solution:

Based on previous example, fct would be 866 psi >> fr and the solution is thus no longer
valid.
The neutral axis is obtained from
As 2.35
ρ = = = 0.0102 (2.15-a)
bd (10)(23)
ρn = (0.010)(8) = 0.08174 (2.15-b)

k = 2ρn + (ρn)2 − ρn (2.15-c)

= 2(0.08174) + (0.08174)2 − (0.08174) = 0.33 (2.15-d)
kd = (.33)(23) = 7.6 in (2.15-e)
 
0.33
jd = 1− (23) = 20.47 in (2.15-f)
3
M
fs = (2.15-g)
As jd
(90)(1, 000)(12)
= = 22, 400 psi (2.15-h)
(2.35)(20.47)
2M
fc = (2.15-i)
bjkd2
(2)(90)(12, 000)
= = 1, 390 psi (2.15-j)
(10) (20.47) (7.6)
     
jd kd
 2
(10)(7.6)3 7.6
I = + (10)(7.6) + 8(2.35)(23 − 7.6)2 = 5, 922 in4 (2.15-k)
12 2

Uncracked Cracked Cracked/uncracked


M k.ft 45 90 2
N.A in 13.2 7.6
fcc psi 485 1,390 (< .5fc ) 2.9
I in4 14,710 5,910 .4 (δα I1 )
fs psi 2,880 22,400 (≈ 7 )
δ in 1 ≈4 4

Example 2-3: Working Stress Design Method; Analysis

Same problem as example 2.1 fc = 4,000 psi; ft = 475 psi; fy = 60,000 psi; As = 2.35 in2 .
Determine Moment capacity.
Solution:

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
2.2 Section Cracked, Stresses Elastic 2–7

As 2.35
ρ = = = .0102 (2.16-a)
bd (10)(23)
fs = 24 ksi (2.16-b)
fc = (.45)(4, 000) = 1, 800 psi (2.16-c)
 
k = 2ρn + (ρn)2 − ρn = 2(.0102)8 + (.0102)2 − (8)(.0102) = .331 (2.16-d)
k
j = 1 − = .889 (2.16-e)
3
N.A. @ (.331)(23) = 7.61 in (2.16-f)
n 8
ρb = = = .014 > ρ ⇒ Steel reaches elastic (2.16-g)
limit
2r(n + r) (2)(13.33)(8 + 13.33)
M = As fs jd = (2.35)(24)(.889)(23) = 1, 154 k.in = 96 k.ft (2.16-h)

Note, had we used the alternate equation for moment (wrong) we would have overestimated
the design moment:
1
M = = fc bkd2 j (2.17-a)
2
1
= (1.8)(10)(0.33)(0.89)(23)2 = 1, 397 k.in > 1, 154 k.in (2.17-b)
2
If we define αc = fc /1, 800 and αs = fs /24, 000, then as the load increases both αc and αs
increase, but at different rates, one of them αs reaches 1 before the other.

αs αc
1

Load

Example 2-4: Working Stress Design Method; Design

Design a beam to carry LL = 1.9 k/ft, DL = 1.0 k/ft with fc = 4, 000 psi, fy = 60, 000 psi,
L = 32 ft.
Solution:

fc = (.45)(4, 000) = 1, 800 psi (2.18-a)

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
2–8

fs = 24, 000 psi


FLEXURE

(2.18-b)
Es 29, 000
n = = √ =8 (2.18-c)
Ec 57 4, 000
fs 24
r = = = 13.33 (2.18-d)
fc 1.8
n 8
k = = = .375 (2.18-e)
n+r 8 + 13.33
d .375
j = 1− =1− = .875 (2.18-f)
3 3
1 1
R = fc kj = (1, 800)(.375)(.875) = 295 psi (2.18-g)
2 2
n 8
ρb = = = .01405 (2.18-h)
2r(n + r) 2(13.33)(8 + 13.33)

Estimate beam weight at .5 k/ft, thus

(32)2
M = [(1.9) + (1.0 + .5)] = 435 k.ft (2.19-a)
8
M 435 k.ft in2 (12, 000) lb.in
bd2 = = = 17, 700 in3 (2.19-b)
R (295) lbs ft k

Take b = 18 in & d = 31.4 in ⇒ h = 36 in


Check beam weight (18)(36) (.15) in2 ft2 k = .675 k/ft√
145 2 3
in ft
As = (.01405)(18)(31.4) = 7.94 in2 ⇒ use 8# 9 bars in 2 layers ⇒ As = 8.00 in2

2.3 Cracked Section, Ultimate Strength Design Method


2.3.1 Whitney Stress Block

ε
γ f’c
βc a/2 = β c
c= a a
c β1
C=α f’cb
c C=γ f’ab
c
h d

As
fs fs

ε Actual
b

Figure 2.5: Cracked Section, Limit State

Figure

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
2.3 Cracked Section, Ultimate Strength Design Method 2–9

18 At failure we have, linear cross strain distribution (ACI 10.2.2) (except for deep beams),

non-linear stress strain curve for the concrete, thus a non-linear stress distribution.
19 Two options:

1. Analytical expression of σ ⇒ exact integration

2. Replace exact stress diagram with a simpler and equivalent one, (ACI 10.2.6)

Second approach adopted by most codes.


20For the equivalent stress distribution, all we we need to know is C & its location, thus α and
β We adopt a rectangular stress, with depth a = β1 c, and stress equal to γfc (ACI 10.2.7.1)

C = αfc bc = γfc ab (2.20-a)


fav
α = (2.20-b)
fc
a = β1 c (2.20-c)

Thus
α
γ= (2.21)
β1
But the location of the resultant forces must be the same, hence

β1 = 2β (2.22)

21 From Experiments

fc ( psi) <4,000 5,000 6,000 7,000 8,000


α .72 .68 .64 .60 .56
β .425 .400 .375 .350 .325
β1 = 2β .85 .80 .75 .70 .65
γ = α/β1 0.85 0.85 0.85 0.86 0.86

22 Thus we have, (ACI-318 10.2.7.3):

β1 = .85 if fc ≤ 4, 000


(2.23)
= .85 − (.05)(fc − 4, 000) 1,000
1
if 4, 000 < fc < 8, 000

23 Failure can occur by either

yielding of steel: εs = εy ; Progressive

crushing of concrete: εc = .003; Sudden; (ACI 10.3.2).

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
2–10

ε u=0.003 0.85 f’c


FLEXURE

a= β1c
C=0.85f’c ab
c

h d
d
As
εs T

Figure 2.6: Whitney Stress Block

2.3.2 Balanced Design


Tension Failure:

fs = fy 
As fs = .85fc ab = .85fc bβ1 c c=
ρfy
.85fc β1 d (2.24-a)
As 
ρ = bd

Compression Failure:

εc = .003 (2.25-a)
fs
εs = (2.25-b)
Es
c .003
= ⇒ c= fs
.003
d (2.25-c)
d .003 + εs Es
+.003

Balanced Design:

24Balanced design occurs if we have simultaneous yielding of the steel and crushing of the
concrete. Hence, we simply equate the previous two equations
ρfy .003
 ρbf 2d .003
 

.85fc β1 d = fs +.003
d 
.85fc β1 = fs +.003
d ρb = .85β1 ffyc 87,000+f
87,000
Es E−s y (2.26-a)
ρ = ρb Es = 29, 000 ksi (ACI 8.4.3)

25 To ensure failure by yielding,

ρ < .75ρb (2.27)

26 ACI strength requirements

U = 1.4D + 1.7L (ACI 9.2.1)


U = 0.75(1.4D + 1.7L + 1.7W ) (ACI 9.2.2)
(2.28)
Md = M u = φMn (ACI 9.1.1)
φ = .90 (ACI 9.3.2.2)

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
2.3 Cracked Section, Ultimate Strength Design Method

27 Also we need to specify a minimum reinforcement ratio


2–11

200
ρmin ≥ (ACI 10.5.1) (2.29)
fy

to account for temperature & shrinkage


28 Note, that ρ need not be as high as 0.75ρb . If steel is relatively expensive, or deflection is of

concern, can use lower ρ.


29 As a rule of thumb, if ρ < 0.5ρb , there is no need to check for deflection.

2.3.3 Review

30 Given, b, d, As , fc , fy , determine the moment capacity M .

ρact = Abds
 (2.30)
ρb = (.85)β1 ffyc 87+f
87
y

• ρact < ρb : Failure by yielding and

s y A f
a = .85f  ΣFx = 0
cb (2.31)
Md = φAs fy (d − a2 ) ΣM = 0

• ρact > ρb is not allowed by code, in this case we have an extra unknown fs .

31 We now have one more unknown fs , and we will need an additional equation (from strain
diagram).
As f s
c = .85f  ΣFx = 0
c bβ1
c .003 (2.32)
d = .003+εs From strain diagram
β1 c
Md = φAs fs (d − 2 ) ΣM = 0

We can solve by iteration, or substitution and solution of a quadratic equation.

2.3.4 Design

32 We consider two cases:

I b d and As , unknown; Md known;


   
As f y ρfy
ΣFx = 0 a = 0.85f b a = 0.85f  fy
c c  Md = Φ ρfy 1 − .59ρ  bd 2
(2.33-a)
ρ = Abds Md = As fy d − a2 fc
  
R

or
 
fy
R = ρfy 1 − .59ρ  (2.34)
fc

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
2–12

which does not depend on unknown quantities. Then solve for bd2 :
FLEXURE

Md
bd2 = (2.35)
ΦR

Solve for b and d (this will require either an assumption on one of the two, or on their
ratio).
As = ρbd
II b & d known & Md known ⇒ there is no assurance that we can have a design with ρb
If the section is too small, then it will require too much steel resulting in an over-reinforced
section.
Iterative approach
(a) Since we do not know if the steel will be yielding or not, use fs .
(b) Assume an initial value for a (a good start is a = d5 )
(c) Assume initially that fs = fy
(d) Check equilibrium of moments (ΣM = 0)
M
As =  d  (2.36)
Φfs d − a2

(e) Check equilibrium of forces in the x direction (ΣFx = 0)


As fs
a= (2.37)
.85fc b
(f) Check assumption of fs by either comparing ρ with ρb , or from the strain diagram
εs .003 d−c
= ⇒ fs = Es .003 < fy (2.38)
d−c c c
a
where c = β1 .
(g) Iterate until convergence is reached.

2.4 Practical Design Considerations


2.4.1 Minimum Depth

33 ACI 9.5.2.1 stipulates that the minimum thickness of beams should be


Simply One end Both ends Cantilever
supported continuous continuous
Solid One
way slab L/20 L/24 L/28 L/10
Beams or
ribbed One way slab L/16 L/18.5 L/21 L/8
where L is in inches, and members are not supporting partitions.
34 Smaller values can be taken if deflections are computed.

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
2.4 Practical Design Considerations

2.4.2 Beam Sizes, Bar Spacing, Concrete Cover


2–13

35 Beam sizes should be dimensioned as


1
1. Use whole inches for overall dimensions, except for slabs use 2 inch increment.
2. Ideally, the overall depth to width ratio should be between 1.5 to 2.0 (most economical).
3. For T beams, flange thickness should be about 20% of overall depth.

36 Reinforcing bars
1. Minimum spacing between bars, and minimum covers are needed to
(a) Prevent Honeycombing of concrete (air pockets)
(b) Concrete (usually up to 3/4 in MSA) must pass through the reinforcement
(c) Protect reinforcement against corrosion and fire
2. Use at least 2 bars for flexural reinforcement
3. Use bars #11 or smaller for beams.
4. Use no more than two bar sizes and no more than 2 standard sizes apart (i.e #7 and #9
acceptable; #7 and #8 or #7 and #10 not).
5. Use no more than 5 or 6 bars in one layer.
6. Place longest bars in the layer nearest to face of beam.
7. Clear distance between parallel bars not less that db (to avoid splitting cracks) nor 1 in.
(to allow concrete to pass through).
8. Clear distance between longitudinal bars in columns not less that 1.5db or 1.5 in.
9. Minimum cover of 1.5 in.
10. Summaries in Fig. 2.7 and Table 2.1, 2.2.

2.4.3 Design Aids

37 Basic equations developed in this section can be easily graphed.


Review Given b d and known steel ratio ρ and material strength, φMn can be readily obtained
from φMn = φRbd2
Design in this case
1. Set Md = φRbd2
2. From tabulated values, select ρmax and ρmin often 0.5ρb is a good economical choice.
3. Select R from tabulated values of R in terms of fy , fc and ρ. Solve for bd2 .
4. Select b and d to meet requirements. Usually depth is about 2 to 3 times the width.
5. Using tabulated values select the size and number of bars giving preference to larger
bar sizes to reduce placement cost (careful about crack width!).
6. Check from tables that the selected beam width will provide room for the bars chosen
with adequate cover and spacing.

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
2–14 FLEXURE

Bar Nominal Number of Bars


Size Diam. 1 2 3 4 5 6 7 8 9 10
#3 0.375 0.11 0.22 0.33 0.44 0.55 0.66 0.77 0.88 0.99 1.10
#4 0.500 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 1.80 2.00
#5 0.625 0.31 0.62 0.93 1.24 1.55 1.86 2.17 2.48 2.79 3.10
#6 0.750 0.44 0.88 1.32 1.76 2.20 2.64 3.08 3.52 3.96 4.40
#7 0.875 0.60 1.20 1.80 2.40 3.00 3.60 4.20 4.80 5.40 6.00
#8 1.000 0.79 1.58 2.37 3.16 3.95 4.74 5.53 6.32 7.11 7.90
#9 1.128 1.00 2.00 3.00 4.00 5.00 6.00 7.00 8.00 9.00 10.00
#10 1.270 1.27 2.54 3.81 5.08 6.35 7.62 8.89 10.16 11.43 12.70
#11 1.410 1.56 3.12 4.68 6.24 7.80 9.36 10.92 12.48 14.04 15.60
#14 1.693 2.25 4.50 6.75 9.00 11.25 13.50 15.75 18.00 20.25 22.50
#18 2.257 4.00 8.00 12.00 16.00 20.00 24.00 28.00 32.00 36.00 40.00

Table 2.1: Total areas for various numbers of reinforcing bars (inch2 )

Bar Number of bars in single layer of reinf.


Size 2 3 4 5 6 7 8
#4 6.8 8.3 9.8 11.3 12.8 14.3 15.8
#5 6.9 8.5 10.2 11.8 13.4 15.1 16.7
#6 7.0 8.8 10.5 12.3 14.0 15.8 17.5
#7 7.2 9.1 11.0 12.8 14.7 16.6 18.5
#8 7.3 9.3 11.3 13.3 15.3 17.3 19.3
#9 7.6 9.9 12.1 14.4 16.6 18.9 21.2
#10 7.8 10.3 12.9 15.4 18.0 20.5 23.0
#11 8.1 10.9 13.7 16.6 19.4 22.2 25.0
#14 8.9 12.3 15.7 19.1 22.5 25.9 29.3
#18 10.6 15.1 19.6 24.1 28.6 33.2 37.7

Table 2.2: Minimum Width (inches) according to ACI Code

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
2.5 USD Examples 2–15

Figure 2.7: Bar Spacing

2.5 USD Examples

Example 2-5: Ultimate Strength; Review

Determine the ultimate moment capacity of example 2.1 fc = 4,000 psi; ft = 475 psi; fy =
60,000 psi; As = 2.35 in2

yt
25" 23"

2
yb
As = 2.35 in

10"

Solution:

As 2.35
ρact = = = .0102 (2.39-a)
bd (10)(23)
f  87 4 87 √
ρb = .85β1 c = (.85)(.85) = .0285 > ρact (2.39-b)
fy 87 + fy 60 87 + 60
As fy (2.35)(60)
a = = = 4.15 in (2.39-c)
.85fc b (.85)(4)(10)

 
a 4.15
Mn = As fy d − = (2.35)(60) 23 − = 2, 950 k.in (2.39-d)
2 2
Md = φMn = 0.9(2, 950) = 2, 660 k.in (2.39-e)

Note:

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
2–16

1. From equilibrium, ΣFx = 0 ⇒ c =


As f y
= (2.35)(60)
= 4.87 in
FLEXURE

.85β1 bfc (.85)(.85)(4)(10)

2. Comparing with previous analysis

uncracked cracked ultimate


c 13.2 7.61 4.87
245
M 45 90 1.7 = 144

3. Alternative solution:
fy
Mn = ρact fy bd2 (1 − .59ρact ) (2.40-a)
fc
fy
= As fy d(1 − 59ρact ) (2.40-b)
fc
60
= (2.35)(60)(23)[1 − (.59) (.0102)] = 2, 950 k.in = 245 k.ft (2.40-c)
4
Md = φMn = (.9)(2, 950) = 2, 660 k.in (2.40-d)

Example 2-6: Ultimate Strength; Design I

Design a R/C beam with L = 15 ft; DL = 1.27 k/ft; LL = 2.44 k/ft; fc = 3,000 psi; fy =
40 ksi; Neglect beam own’s weight; Select ρ = 0.75ρb
Solution:

wu = 1.4(1.27) + 1.7(2.44) = 5.92 k/ft Factored load (2.41-a)


wu L 2 (5.92)(15) 2
Md = = = 166.5 k.ft(12) in/ft = 1, 998 k.in (2.41-b)
8 8
f  87
ρ = 0.75ρb = (0.75)(0.85)β1 c (2.41-c)
fy 87 + fy
3 87
= (0.75)(.85)2 = .0278 (2.41-d)
 40 87+ 40
fy
R = ρfy 1 − .59ρ  (2.41-e)
f
 c 
40
= (.0278)(40) 1 − (0.59)(.0278) = 0.869 psi (2.41-f)
3
Md 1, 998
bd2 = = = 2, 555 in3 (2.41-g)
φR (0.9)(0.869)

Take b = 10 in, d = 16 in ⇒ As = (.0278)(10)(16) = 4.45 in2 ⇒ use 3 # 11

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
2.6 T Beams, (ACI 8.10) 2–17

Example 2-7: Ultimate Strength; Design II

Design a R/C beam for b = 11.5 in; d = 20 in; fc = 3 ksi; fy = 40 ksi; Md = 1, 600 k.in
Solution:

d 20
Assume a = 5 = 5 = 4 in

Md (1, 600)
As = a = = 2.47 in2 (2.42)
φfy (d − 2 ) (.9)(40)(20 − 42 )
check assumption,
As fy (2.47)(40)
a= 
= = 3.38 in (2.43)
(.85)fc b (.85)(3)(11.5)
Thus take a = 3.3 in.

(1, 600)
As = = 2.42 in2 (2.44-a)
(.9)(40)(20 − 3.32 )
(2.42)(40) √
⇒a = = 3.3 in (2.44-b)
(.85)(3)(11.5)
2.42
ρact = = .011 (2.44-c)
(11.5)(20)
3 87
ρb = (.85)(.85) = .037 (2.44-d)
40 87 + 40 √
ρmax = .75ρb = .0278 > ρact (2.44-e)

2.6 T Beams, (ACI 8.10)

38 Equivalent width for uniform stress, Fig. 2.8 must satisfy the following requirements (ACI

8.10.2):

1. 1
2 (b − bw ) ≤ 8hf

2. b < 4bw for isolated T beams only


bw
3. hf > 2
L
4. b < 4

39 Two possibilities:

1. Neutral axis within the flanges (c < hf ) ⇒ rectangular section of width b, Fig. 2.9.

2. Neutral axis in the web (c > hf ) ⇒ T beam.

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
2–18 FLEXURE

be

hf 1111111111
0000000000
0000000000
1111111111
0000000000
1111111111
0000000000
1111111111
0000000000
1111111111
0000000000
1111111111
0000000000
1111111111
bw

Figure 2.8: T Beams

h
00000000000000000
11111111111111111
11111111111111111
00000000000000000
f

h d

As

Figure 2.9: T Beam as Rectangular Section

b
ε u =0.003 0.85 f’c

hf 11111111111111111
00000000000000000
00000000000000000
11111111111111111 a=β1 c
00000000000000000
11111111111111111
00000000000000000
11111111111111111 c
C=0.85f’ a
c
00000000000000000
11111111111111111
00000000000000000
11111111111111111
hd 00000000000000000
11111111111111111
d
As
εs T=As yf

bw

Figure 2.10: T Beam Strain and Stress Diagram

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
2.6 T Beams, (ACI 8.10)

40
2–19

For T beams, we have a large concrete area, start by assuming that failure will occur by steel
yielding, Fig. 2.10.
41 The approach consists in decomposing As into 2 components Fig. 2.11.

1. Asf → resists compression force in (b − bw )hf

2. (As − Asf ) → resists compression force in bw c

2.6.1 Review

42 Given, b, d, hf , As , fc , fy , determine the moment capacity M , Fig. 2.11.


b

00000
11111
00000
11111 00000
11111
00000
11111 11111
00000
hf
00000
11111 00000
11111 00000
11111
00000
11111
00000
11111 00000
11111 00000
11111
00000
11111 c
00000
11111
00000
11111
00000
11111
= + 00000
11111

bw A sf A s − A sf
As (b−b w)h f bwc

Figure 2.11: Decomposition of Steel Reinforcement for T Beams

43 The moment is obtained from

Flanges:
.85fc (b−bw )hf
Asf = fy ΣF = 0
h
(2.45)
Mn1 = Asf fy (d − 2f ) ΣM = 0

Web:
s (A −A
sf y )f
a = .85fc bw ΣF = 0
(2.46)
Mn2 = (As − Asf )fy (d − 2 ) ΣM = 0
a

Total moment:
Mn = Mn1 + Mn2 (2.47)

2.6.2 Design, (balanced)

44 Let us derive an expression for ρb and use it for design


c
d = εuε+ε
u
y
Strain Compatibility
 
As fy = .85fc β1 cbw + .85fc (b − bw )hf ΣF = 0 (2.48)
  
Asf fy

thus,
 ρb
As fy = .85fc β1 cbw + Asf fy    
 
fc εu
As
ρ w = bw d ρw = .85 β1 +ρf (2.49)
Asf 
 fy εu + εy
ρf = bwd
Victor Saouma Mechanics and Design of Reinforced Concrete
Draft
2–20

Hence,
FLEXURE

ρwb = ρb + ρf (2.50)
ρw,max = .75(ρb + ρf ) (2.51)

Example 2-8: T Beam; Moment Capacity I

For the following beam: As = 8 # 11 ( 12.48 in2 ); fc =3,000 psi; fy = 50,000 psi. Determine
Mn
30"
ε u=0.003 0.85 f’c
11111111111111111
00000000000000000 a= β1c
7" 00000000000000000
11111111111111111
00000000000000000
11111111111111111 C=0.85f’c ab
00000000000000000
11111111111111111 c
00000000000000000
11111111111111111
00000000000000000
11111111111111111
36" 00000000000000000
11111111111111111
d
εs T=Asfy

14"

Solution:

1. Check requirements for isolated T sections



(a) bw = 30 in should not exceed 4bw = 4(14) = 56 in

(b) hf ≥ b2u ⇒ 7 ≥ 14
2

2. Assume Rectangular section


As fy (12.48)(50)
a= 
= = 8.16 in > hf (2.52)
.85fc b (0.85)(3)(30)

3. For a T section
.85fc hf (b − bw )
Asf = (2.53-a)
fy
(.85)(3)(7)(30 − 14)
= = 5.71 in2 (2.53-b)
50
Asf 5.71
ρf = = = .0113 (2.53-c)
bwd (14)(36)
Asw = As − Asw = 12.48 − 5.71 = 6.77 in2 (2.53-d)
Asw 12.48
ρw = = = .025 (2.53-e)
bw d (14)(36)
f  87
ρb = .85β1 c (2.53-f)
fy 87 + fy
3 87
= (.85)(.85) = .0275 (2.53-g)
50 87 + 50

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
2.6 T Beams, (ACI 8.10)

4. Maximum permissible ratio


2–21

ρmax = .75(ρb + ρf ) (2.54-a)



= .75(.0275 + .0113) = .029 > ρw (2.54-b)

5. The design moment is then obtained from


 
7
Mn1 = (5.71)(50) 36 − = 9, 280 k.in (2.55-a)
2
(As − Asf )fy
a = (2.55-b)
.85fc bw
(6.77)(50)
= = 9.48 in (2.55-c)
(.85)(3)(14)
9.48
Mn2 = (6.77)(50)(36 − ) = 10, 580 k.in (2.55-d)
2
Md = (.9)(9, 280 + 10, 580) = 17, 890 k.in → 17, 900 k.in (2.55-e)

Example 2-9: T Beam; Moment Capacity II

Determine the moment capacity of the following section, assume flange dimensions to satisfy
ACI requirements; As = 6#10 = 7.59 in2 ; fc = 3 ksi; fy =60 ksi.
28"
ε u=0.003 0.85 f’c
11111111111111111
00000000000000000 a= β1c
6" 00000000000000000
11111111111111111
00000000000000000
11111111111111111 C=0.85f’c ab
00000000000000000
11111111111111111
00000000000000000
11111111111111111
c
00000000000000000
11111111111111111
26" 00000000000000000
11111111111111111
d
εs T=Asfy

10"

Solution:

Assume rectangular beam


7.59
ρ = = .0104 (2.56-a)
(28)(26)
  
3 87
ρb = (.85)(.85) = .0214 > ρ ⇒ fs = fy (2.56-b)
60 87 + 60
(As − Asf )fy
a = (2.56-c)
.85fc bw

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
2–22

(7.59)(60)
FLEXURE

= = 6.37 in > 6 in ⇒ T beam (2.56-d)


(.85)(3)(28)
(.85)(3)(18)(6)
Asf = = 4.59 in2 (2.56-e)
60
Asw = 7.59 − 4.59 = 3.00 in2 (2.56-f)
7.59
ρw = = .0292 (2.56-g)
(26)(10)
4.59
ρf = = .0177 (2.56-h)
(26)(10)
ρmax = .75(.0214 + .0177) = .0294 > .0292 ⇒ Ductile failure (2.56-i)
Mn1 = (4.59)(60)(26 − 3) = 6, 330 k.in (2.56-j)
As − Asf= 7.59 − 4.59 = 3. in 2
(2.56-k)
(3)(60)
a = = 7.07 in (2.56-l)
(.85)(3)(10)
7.07
Mn2 = (3.00)(60)(26 − ) = 4, 050 k.in (2.56-m)
2
Md = (.9)(6, 330 + 4, 050) = 9, 350 k.in (2.56-n)

Example 2-10: T Beam; Design

given L = 24 ft; fy = 60 ksi; fc = 3 ksi; Md = 6, 400 k.in; Design a R/C T beam.

3"
20"

11"
47"
Solution:

1. Determine effective flange width:



1
− bw ) ≤ 8hf
2 (b 


16hf + bw = (16)(3) + 11 = 59 in
b = 47 in (2.57-a)
L 24
4 = 4 12 = 72 in 


Center Line spacing = 47 in

2. Assume a = 3 in
Md 6, 400
As = a = = 6.40 in2 (2.58-a)
φfy (d − 2 ) 0.9)(60)(20 − 32 )
Victor Saouma Mechanics and Design of Reinforced Concrete
Draft
2.7 Doubly Reinforced Rectangular Beams

As fy (6.4)(60)
2–23

a = 
= = 3.20 in > hf (2.58-b)
(.85)fc b (.85)(3)(47)

3. Thus a T beam analysis is required.


.85fc (b − bw )hf (.85)(3)(47 − 11)(3)
Asf = = = 4.58 in2 (2.59-a)
fy 60
hf 3
Md1 = φAsf fy (d − ) = (.90)(4.58)(60)(20 − ) = 4, 570 k.in (2.59-b)
2 2
Md2 = Md − Md1 = 6, 400 − 4, 570 = 1, 830 k.in (2.59-c)
(2.59-d)

d 20
4. Now, this is similar to the design of a rectangular section. Assume a = 5 = 5 = 4. in

1, 830
As − Asf =   = 1.88 in2 (2.60)
(.90)(60) 20 − 42

5. check
1.88)(60)
a = = 4.02 in ≈ 4.00 (2.61-a)
(.85)(3)(11)
As = 4.58 + 1.88 = 6.46 in2 (2.61-b)
6.46
ρw = = .0294 (2.61-c)
(11)(20)
4.58
ρf = = .0208 (2.61-d)
(11)(20)
  
3 87
ρb = (.85)(.85) = .0214 (2.61-e)
60 87 + 60

ρmax = .75(.0214 + .0208) = .0316 > ρw (2.61-f)

6. Note that 6.46 in2 (T beam) is close to As = 6.40 in2 if rectangular section was assumed.

2.7 Doubly Reinforced Rectangular Beams

45 Negative steel reinforcement is needed to


1. Increase internal moment resistance capacity (not very efficient)

2. Support stirrups

3. Reverse moments (moving load)

4. Provide ductility (earthquake)

5. Reduce creep (long term deflections)

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
2–24

ε u=0.003 0.85 f’c 0.85 f’c


FLEXURE

A’s f’s A’s f’s


A’s d’ εs’ a= β1c a= β1c
c

h d d−d’
= +
d

As εs Asfs (As− A’s )f s


Asfs

Figure 2.12: Doubly Reinforced Beams; Strain and Stress Diagrams

46 Approach will again be based on a strain compatibility analysis & equilibrium equation, Fig.
2.12.
47 If ρ ≤ ρmax = .75ρb we can disregard compression steel
48 As for T beams, we decompose the tension steel into two components

1. As to resist the force in the top steel (assuming both yield)

2. As − As to resist compression in the concrete.

and we define
As
ρ = (2.62)
bd

2.7.1 Tests for fs and fs

49 Different possibilities: Fig. 2.13

Yes Not Allowed by ACI


As yield? No

Yes A’s yield? No Yes A’s yield? No

I II III IV
f = fy f = fy f < fy f < fy
s s s s
f’ = f y f’ < f f’ = f f’ < f y
s s y s y s

Figure 2.13: Different Possibilities for Doubly Reinforced Concrete Beams

Test 1 fs = fy ?
Assuming εs = εy , and fs = fy , we have from the strain diagram, Fig. ??

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
2.7 Doubly Reinforced Rectangular Beams

ε u =0.003
2–25

d’ εs’
A’s

h d

εs = εy
As

Figure 2.14: Strain Diagram, Doubly Reinforced Beam; is As Yielding?

d
εs = εu − (εu + εy ) (2.63-a)
d
fs = Es εs (2.63-b)
εu
c = d (2.63-c)
ε u + εy
(2.63-d)

From equilibrium:
ρbdfy = ρ bdfs + .85fc β1 bc (2.64)
Combining:
fs f εu
ρb = ρ1 = ρ + .85 c β1 (2.65)
fy fy εu + εy
  
ρb

thus

fs
ρb = ρ1 = ρ + ρb (2.66)
fy
f
ρmax = 0.75ρb + ρ s (2.67)
fy

Note that 0.75 premultiplies only one term as in the other failure is ipso facto by yielding.
We also note the similarity with ρmax of T Beams (where 0.75 premultiplied both terms).

Test 2 fs = fy is fs = fy ?
We set εs = εy , and from the strain diagram
εu
c= d (2.68)
εu − ε y

from equilibrium
ρbdfy = ρ bdfy + .85fc β1 cb (2.69)

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
2–26

ε u =0.003
FLEXURE

d’ εs’ = εy
A’s

h d

εs > εy
As

Figure 2.15: Strain Diagram, Doubly Reinforced Beam; is As Yielding?

combining
fc d 87
ρmin ≡ ρ2 = ρ + .85β1 (2.70)
fy d 87 − fy
which corresponds to the minimum amount of steel to ensure yielding of compression steel
at failure. Thus, if ρ < ρmin then fs < fy .
Test 3 fs < fy , is fs = fy ?
From strain diagram:
εu
c = d (2.71-a)
εu − ε y
d−c
εs = εy (2.71-b)
c − d
From equilibrium
ρbdfs = ρ bdfy + .85fc β1 bc (2.72-a)
combining
 
c − d  f c
ρ = ρ3 = ρ + .85β1 c (2.73)
d−c fy d

Summary of the tests are shown in Fig. 2.16

2.7.2 Moment Equations


Case I fs = fy and fs = fy , (small bottom and top reinforcement ratios)

As fy = As fy + .85fc ab (2.74-a)


(As − As )fy
a = (2.74-b)
.85fc b


a
MnI = .85fc ab d − + As fy (d − d ) (2.75)
2

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
2.7 Doubly Reinforced Rectangular Beams

Test 2 Test 1 Test 3


2–27

ρmin ρ ρ
ρ
II I III IV

f’ < fy f’ = f y f=fy f <fy f’ < f y f’ = f y


s s s s s s

Figure 2.16: Summary of Conditions for top and Bottom Steel Yielding

Case II We have fs = fy and fs < fy (small bottom and large top reinforcement ratios, most
common case)

c − d
εs = εu (2.76-a)
c
fs = Es εs (2.76-b)
As fy = As fs + .85fc bβ1 c (2.76-c)
solve for c and fs by iteration.
Using a = β1 c

a
MnII = .85fc ab d − + As fs (d − d ) (2.77)
2

Case III fs < fy and fs = fy (large bottom and small top reinforcement ratios, rare)

d−c
ε s = εu (2.78-a)
c
fs = E s εs (2.78-b)
As fs = As fy + .85fc ab (2.78-c)
a = β1 c (2.78-d)
solve for a


a
MnIII = .85fc ab d − + As fy (d − d ) (2.79)
2

Case IV fs < fy and fs < fy (large bottom and top reinforcement ratios, rare)

c − d
εs = εu (2.80-a)
c
d−c
εs = εu (2.80-b)
c
As fs = As fs + .85fc ab (2.80-c)
a = β1 c (2.80-d)

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
2–28

solve for a
FLEXURE


a
MnIV = .85fc ab d − + As fs (d − d ) (2.81)
2

50 Note that in most beams of normal size and proportions, it will be found that fs < fy when
fs = fy . We nevertheless use As in order to ensure ductility, stiffness and support for the
stirrups.

Example 2-11: Doubly Reinforced Concrete beam; Review

Given, fc = 4, 000 psi, fy = 60,000 psi, As = 3 (1.56) = 4.68 in2 , As = 4 (1.56) = 6.24 in2 ,
determine the moment carrying capacity of the following beam.
A’s = 3 # 11 ε u =0.003 0.85 cf’ 0.85 f’
c
A’s f’s A’s f’y
3" εs’ a=β c a=β1 c
c 1

27.3" = d−d’ +
d

εs As sf (As − A’ )
s s
As yf

16"
As = 4 # 11

Solution:

1. Determine ρ:

fc 87 4 87
ρb = (.85)β1 = (.85)(.85) = .0285 (2.82-a)
fy 87 + fy 60 87 + 60
6.24
ρ = = .0143 (2.82-b)
(16)(27.3)
4.68
ρ = = .0107 (2.82-c)
(16)(27.3)

2. Check for ρmin

fc d εu
ρmin = ρ + .85 β1 (2.83-a)
fy d εu − εy
4 3 .003
= .0107 + (.85) (.85) = .0278 > ρ (2.83-b)
60 27.3 .003 − 29,000
60

Hence
ρ < ρmin < ρb
(2.84)
.0143 < .0278 < .0285
and thus fs = fy and fs < fy and we have case II

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
2.7 Doubly Reinforced Rectangular Beams

3. We have two equations (strain compatibility and summation of forces) and two unknowns
2–29

c and fs
c − d c−3
fs = Es εu = (29, 000)(.003) (2.85-a)
c c
c−3
= 87 (2.85-b)
c
As fy = As fs + .85fc bβ1 c (2.85-c)
(6.24)(60) = (4.68)fs + (.85)(4)(16)(.85)c (2.85-d)
374.4 = 4.68fs + 46.24c (2.85-e)
fs = −9.9c + 80.2 (2.85-f)
Note that if we were to plott those two equations,

50

25

2 3 4 5 6

-25

-50

-75

-100

We note that f  s increases with c from the strain diagram, but fs decreases with c from
equilibrium. Graphically the solution is around 4.9.
4. Combining those two equations1
c2 + .7085c − 26.42 = 0 (2.86)
we obtain c = 4.80 in a = 0.85(4.8) = 4.078 in, and fs = (.003)(29, 000) 4.80−3
4.80 = 32.6 ksi

5. Substituting into the moment equation



a
Mn = .85fc ab d − + As fs (d − d ) (2.87-a)
2  
4.078
= (.85)(4)(4.078)(16) 27.3 − + (4.68)(32.62)(27.3 − 3) (2.87-b)
2
= 9, 313 k.in (2.87-c)
Md = 0.9(9, 313) = 8, 382 k.in = 699 k.ft (2.87-d)

6. Check
fs 
ρmax = .75ρb + ρ (2.88-a)
fy
32.6 √
= (.75)(.0285) + (.0107) = 
.027 (2.88-b)
60
ρ

1
In this problem, unfortunately an iterative method diverges if we were to start with a = d5 .

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
2–30 FLEXURE

Example 2-12: Doubly Reinforced Concrete beam; Design

Given Md = 505 k.ft, fc = 4 ksi, fy = 60 ksi, b = 12 in, h = 24.5 in, d = 21 in, and
d= 2.5 in, determine the reinforcement As and possibly As .
Solution:

1. Check if T or rectangular:

Md = (505)(12) = 6, 060 k.in (2.89-a)


f  87 4 87
ρb = .85β1 c = (.85)(.85) = .0285 (2.89-b)
fy 87 + fy 60 87 + 60
ρmax = .75ρb = (.75)(.0285) = .0213 (2.89-c)
Amax
s = (.0213)(12)(21) = 5.37 in 2
(2.89-d)
As fy (5.37)(60)
a = = = 7.89 in (2.89-e)
.85fc b (.85)(4)(12)

 
a 7.89
Mmax = (0.9)As fy d − = (.9)(5.37)(60) 21 − = 4, 943 k.in < 6, 060
(2.89-f)
k.in
2 2
Thus compression steel is required.
2. Assuming that fs = fy

Md2 = 6, 060 − 4, 943 = 1, 117 k.in (2.90-a)


Md2 1, 117
As = 
= = 1.12 in2 (2.90-b)
φfy (d − d ) (0.9)(60)(21 − 2.5)
⇒ As = 1.12 in2 (2.90-c)
As = 5.37 + 1.12 = 6.49 in2 (2.90-d)

3. Check that fs = fy


1.12
ρ = = .00444 (2.91-a)
(12)(21)
6.49
ρ = = .0257 (2.91-b)
(12)(21)
f  d  εu
ρmin = ρ + .85β1 c (2.91-c)
fy d εu − εy
4 2.5 87 √
= .00444 + (.85)(.85) = .0229 < ρ(.0257) (2.91-d)
60 21.0 87 − 60

Note that if it turned out that fs < fy , then we will need to make an assumption on As (such
as As = A2s , as we will have three equations (2 of equilibrium and one of strain compatibility)
and four unknowns (As , As , fs and c).

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
2.8 Bond & Development Length

2.8 Bond & Development Length


2–31

51Considering the equilibrium of forces acting on an infinitesimal portion of a rebar, Fig. 2.17,
and defining U as the force per unit length, we have
M M +∆M
111
000
000
111
000
111
111
000 111
000
C C + dC
T 000000000000000000
111111111111111111 T+dT
Z 000000000000000000
111111111111111111
000000000000000000
111111111111111111
V V+dV
T T+dT
dx
dx

Figure 2.17: Bond and Development Length

dT
U dx = dT ⇒ U = (2.92)
dx

52 The tensile force is a function of the moment

M = T jd (2.93-a)
dM
dT = (2.93-b)
jd

53 But the shear is related to the moment


dM
V = (2.94)
dx
Combing those equations together, we obtain
V
U= (2.95)
jd

54 We define u as the bond stress, and is equal to


U
u= (2.96)
Σ0
where Σ0 is the sum of all the bars perimeters.
55 If plain bar → weak adhesion → slip → need end anchorage → no bond → u = 0 → dT = 0 →
steel stress is constant over entire length → T = Mjd
max
→ total steel elongation >than if bond
present → large deflection and large crack width.
56 Actual stress distribution along steel bar is quite complex, Fig. 2.18.
57 If bond stress is too large ⇒ splitting along reinforcement, Fig. 2.19.

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
2–32 FLEXURE

u stresses on concrete
M M

u stresses on rebar

1111111111111111111111111111111111
0000000000000000000000000000000000
0000000000000000000000000000000000
1111111111111111111111111111111111
1111111111111111111111111111111111
0000000000000000000000000000000000

Steel tension slope =dT


dx

Bond stress u

Figure 2.18: Actual Bond Distribution

Figure 2.19: Splitting Along Reinforcement

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
2.8 Bond & Development Length

58

Failure will initiate at points of high shear large dM

.
2–33

dx

59It frequently starts at diagonal cracks ⇒ dowel action increases the tendancy of splitting ⇒
shear and bond failures are often interrelated.
60Basedon tests with one single bar, ultimate average bond force/inch of length of bar is
Un ≈ 35 fc .
61If we have several bars in one layer spaced 6 in or less, then the ultimate bond capacity is
80% of the single bar case.
62 In terms of bond stress, Fig. 2.20 
35 fc
un = (2.97)
Σ0

1111111111111111111111111111111111
0000000000000000000000000000000000

Ts = 0 Ld Ts= A yf
b

Figure 2.20: Development Length

63 Putting it differently, the minimum length necessary to develop through bond a force As fy
is, Fig. ??. 
A f
Ld = Ubny   0.028Ab fy
Un = un√ Σ0 ld =  (2.98)
35 fc 
 fc
un = Σ0

U
A sf y

L
d

Figure 2.21: Development Length

64 For small bar spacing, we have to decrease the bond stress


1 0.028Ab fy 0.035Ab fy
ld =  =  (2.99-a)
0.8 
fc fc

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
2–34

65
FLEXURE

If actual development length l is smaller than ld , then we must provide anchorage in order
to avoid a bond failure.
66 Note:

1. Un is independent of diameter

2. For a given fs

T = Ab fs 
πd2 fs πd2b
= fs 4 b ld = (2.100-a)
Ab f s 
4Un
ld = Un 

ld increases with the square of db ⇒ small bar diameters require shorter development
length.

67Top bars, with more than 12 inch of concrete below them, will have a reduced bond stress
(due to rise of water during vibration). This reduction in bond results in an increase of ld by
40%
68 ACI 12.2.2 may be obtained from above but rather than use φ we increase ld by 15% for
safety.

ldb = .04 √b
A fy
#11 or smaller; and deformed wire
fc
.085 √ 
fy
= #14
fc (2.101)
.125 √y 
f
= #18
fc
> 12 in. in all cases

Consult ACI 12.5 code for hooks geometry, and corrections to this basic equation.
69 Check ACI code for modifications related to top reinforcement, lightweight aggregate, high
strength reinforcement, excess reinforcement, and spiral confinement.

ld = λd λdd ldb (2.102)

70 If not enough development length can be provided ⇒ provide hooks, Fig. 2.22 at

1. 90 degrees: bar must extend by 12db

2. 180 degrees: see code.

where
lhb = 1200 √db 
fc (2.103)
ldh = λd lhb
and λd is given in the ACI code.

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
2.8 Bond & Development Length 2–35

db
As in part (b)

Critical
section 12db

ldh

(a)

db

Critical
section 4db or 2 1/2 4db Nos. 3 through 8
in. min.
5db Nos. 9, 10, 11
ldh 6db Nos. 14 and 18

(b)

Figure 2.22: Hooks

2.8.1 Moment Capacity Diagram

71 Ideally, the steel should be everywhere as nearly fully stressed as possible. Since the steel
force is proportional to the moment, then the steel area is nearly proportional to the moment
diagram.
72 Requirements include, Fig. 2.23:
1. At least A3s in simple beams and As
4 for continuous beams should be extended at least 6
in. into support.
2. If negative bars are cut, they must extend at least ld beyond face of support.
3. Negative bars must extend d or 12db beyond theoretical cutoff point defined by moment
diagram.
4. At least one third of top reinforcement at support must extend at least ld beyond the-
ln
oretical cutoff point of other bars, and d, 12db or 16 beyond the inflection point of the
negative moment diagram.

73 Determination of cutoff points can be rather tedious, for nearly equal spans uniformly loaded,
in which no more than about one half the tensile steel is to be cut off or bent, locations shown
in Fig. 2.24 are satisfactory (note that left support is assumed simply supported).
74 Fig. 2.25 is an illustration of the moment capacity diagram for a beam.

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
2–36 FLEXURE

Theoretical
positive
moment
Face of support

Inflection point
for (+As) Moment Capacity
of bars O

of span
Theoretical
negative
Inflection point
moment for (-As)

L
Moment capacity

C
of bars M

Greatest of d, 12 d , ln/16 b

d or 12 db for at least 1/3 of (-AS)

ld

Bars M ld Bars N

Bars L ld Bars O

ld d or 12 db
6" for at least
1/4 of (+AS)
(1/3 for simple spans)

Figure 2.23: Bar cutoff requirements of the ACI code

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
2.8 Bond & Development Length 2–37

L1 L1 L2 L2
4 3 3 3

0" 0" L2
L1 L2
6"
8
6" 6" 8
8
L1 L2

L1 L1 L2 L2
4 3 3 3

0" 0" L2
6" L1 L1 L2
7 4 6" 6" 4
4
L1 L2

Figure 2.24: Standard cutoff or bend points for bars in approximately equal spans with uni-
formly distributed load

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
2–38 FLEXURE

A B C

5 bars
2 bars 4 bars AA

A B C
BB
Ld

Ld Mcap of 5 bars

CC
Mcap of 4 bars
Md=φMn
Ld

Mcap of 2 bars

d or 12’’

Figure 2.25: Moment Capacity Diagram

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft

Chapter 3

SHEAR

3.1 Introduction

1 Beams are subjected to both flexural and shear stresses. Resulting principal stresses (or stress
trajectory) are shown in Fig. 3.1.

Tension trajectories
Compression trajectories
90 α
45

τ τ τ τ
σ1 σ2
τ
τ σ τ σ
α
τ
σ
τ σ τ
τ ο
45 τ σ2 σ1

Figure 3.1: Principal Stresses in Beam

2 Due to flexure, vertical flexural cracks develop from the bottom fibers.
3 As a result of the tensile principal stresses, two types of shear cracks may develop, Fig. 3.2:
Large V Large V
Small M Large M

Web Shear Cracks Web Shear Cracks Flexural Cracks


Flexural Cracks

Figure 3.2: Types of Shear Cracks

Web shear cracks: Large V, small M. They initiate in the web & spread up & down at ≈ 45o .

Flexural shear cracks: Large V, large M. They initiate as an extension of a pre-existing


flexural crack, initially vertical, then curve.
Draft
3–2

4 Shear failure is sudden ⇒ φ = 0.85


SHEAR

5 Some of the important parameters controlling shear failure:


M
1. Shear span ratio Vd

2. Steel ratio ρ = Abds


 
3. ft = 4 fe note that fr = 7.5 fc

6 We shall first examine the shear strength of uncracked sections, then the one of cracked

sections (with shear reinforcement).

3.2 Shear Strength of Uncracked Section

7 Q: What is the maximum shear force which can be applied before a flexural crack develop

into a flexural shear crack?

1. Apply M → flexural crack

2. Apply V → flexural shear crack

8 Note that all shear resistance is provided by the concrete. As with flexural reinforcement,
steel is ineffective as long as the section is uncracked.
C vc τ
σ
jd +

Flexure Shear
T

Figure 3.3: Shear Strength of Uncracked Section

9 Solution strategy:
1. Determine the flexural compressive stress fc in terms of M

2. Determine shear stress v in terms of V

3. Compute the principal stresses

4. Equate principal tensile stress to the tensile strength

10 Using a semi-analytical approach


1. Assume that fc is directly proportional to steel stress

fc = α fns  f = α Mn  αMn Mn
c nAs jd fc = = F1 (3.1)
 ρ = As
nρjbd 2 ρnbd 2
Mn = As fs jd ⇒ fs = AMs jdn bd

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
3.2 Shear Strength of Uncracked Section

2. Shear stress
3–3

Vn
vn = F2 (3.2)
bd
3. From Mohr’s circle, the tensile principal stress is
τ

vn

fc f1
σ

Figure 3.4: Mohr’s Circle for Shear Strength of Uncracked Section

 2
fc fc
f1 = + + vn2 (3.3)
2 2

4. Set f1 equal to the tensile strength


Vn Vn
f1 = ft ⇒ f1 = ft (3.4-a)
bd bd
Vn ft Vn
= (3.4-b)
bd f1 bd
ft
= f1 bd
(3.4-c)
Vn

Combining Eq. 3.1, 3.2, and 3.3

Vn ft
=  2 1/2 (3.5)
bd
 F E  
F1 Ec Mn  1 c Mn  2 
+   + F2 
2 E ρVn d  2 Es ρVn d  
  s    C 2
C1 C1

5. set ft = 4 fc
Vn 1
 =  2 (3.6)
bd fc √ √
fc Mn C1 fc Mn
C1 ρ Vn d + ρ Vn d + C2


Mn fc
6. Let the variables be √n
V
&
bd fc ρVn d

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
3–4 SHEAR

7. This is how far we can go analytically. To determine the exact factors associated with
this equation, one has to undertake a series of tests.

8. From 440 tests, Fig. 3.5 it is found that

Vn

bd f’c
3.5

2.0
1.9

Vn d
M f’
n c

Figure 3.5: Shear Strength of Uncracked Section

Vn ρVn d
 = 1.9 + 2, 500  ≤ 3.5 (3.7)
bd fc Mn fc

Vn
or if we set vc = bd , then

 ρVn d 
vc = 1.9 fc + 2, 500 ≤ 3.5 fc (ACI 11.3.2.1) (3.8)
Mn

Vn d
9. Note that vc is in terms of M or inverse of shear span ( M
V )

10. This equation is usually found acceptable for predicting the flexure shear cracking load
for shear span/depth ratio VMnnd of 2.5 to 6 & is found to be very conservative for lower
values

11. Increasing ρ has a beneficial effort as a larger amount of steel results in narrower & smaller
flexural tension cracks before formation of diagonal cracks ⇒ larger area of uncracked
concrete can resist the shear.
Vu Mu
12. Use of Vu & Mu instead of Vn = φ & Mn = φ

3.3 Shear Strength of Cracked Sections



11If the shear stress exceeds 1.9 fc + 2, 500ρ VMndd , then the flexural crack will extend into a
flexural shear crack, Fig. 3.6. and if
1. No shear reinforcements ⇒ failure

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
3.3 Shear Strength of Cracked Sections

s
3–5

C
Vc

A v fv z
Va
T=As fs
Vd

Figure 3.6: Free Body Diagram of a R/C Section with a Flexural Shear Crack

2. Stirrups are present ⇒ stirrups will carry part of shear force

12 If the section is cracked, Fig. 3.7


Vext = Vc + Σn Av fv + Vd + Vay (3.9)
  
Vint

where
Vc Shear resisted by uncracked section
p
n # of stirrup traversing the crack n = s
Av Area of shear reinforcement
fv Shear reinforcement stress
Vd Dowel force in steel
Va Aggregate interlock
V int

V cz
t
in

Vd
ΣV

V ay

Vs
Vext
Yield of stirups
Flexural cracking

Inclined cracking

Failure

Figure 3.7: Equilibrium of Shear Forces in Cracked Section

13 We must determine the internal (resisting) shear forces at failure where fv = fy

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
3–6

1. Due to yielding → large separation between 2 sides of cracks ⇒ Va → 0


SHEAR

2. Neglect Vd
3. Vext = Vn = Vc +nAv fy

unknown
4. We will assume that at failure the shear force provided
 by concrete is equal to the one
which caused the diagonal crack to form ⇒ va = 1.9 fc + 2, 500ρ VMndd . Thus, Vc = va bw d
5. Finally, if we assume p = d (implying a crack at 45◦ )

d
Vn = Vc + Av fy (ACI 11.1.1) (3.10)
  s
Vs

3.4 ACI Code Requirements


#
14 The ACI code requirements ( 11) are summarized by Fig. 3.8:
1. Design for Vu (factored shear) rather than Vn = Vu
φ (ACI 11.1.1), ⇒ plot Vu diagram.
2. Determine φVc (nominal shear carried by the concrete) where

Vc = 2 fc bw d (ACI 11.3.1.1)
or  
Vc = [1.9 fc + 2, 500ρw VMuud ]bw d ≤ 3.5 fc bw d (ACI 11.3.2.1) (3.11)
where
Vu d
Mu < 1

3. If Vu <0.5 φVc no shear reinforcement is needed (ACI 11.5.5.1)


4. If 0.5φVc < Vu ≤ φVc use minimum shear reinforcement; select Av (usually #3 bars) and
determine
Av f y
s = 50b w
(ACI 11.5.5.3)
d (3.12)
s < 2 (ACI 11.5.4.1)
s < 24 in (ACI 11.5.4.1)
5. If Vu > φVc ⇒ provide stirrup such that
Vu Av fy d
= Vn = Vc + Vs = Vc + (ACI 11.17) (3.13)
φ s
or
Av fy d φAv fy
s = = (3.14)
Vu
φ − Vc (vu − φvc )b

6. If Vu − Vc > 4 fc bw d, then s < d
4 and s < 12 in, (ACI 11.5.4.3).
7. Upper limit: 
Vu − Vc < 8 fc bw d (ACI 11.5.6.8) (3.15)
8. fy ≤ 60 ksi, (ACI 11.5.2)
9. Critical section is at d from support (reduces design shear force), (ACI 11.1.3.1)

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
3.5 Examples

d
3–7

V
b wd

Vu
φ
10 f ’c
f ’c

6 f ’c Steel
8

f ’c
4

2 f ’c
f ’c Concrete

not allowable s max=d/4 or 12" s max=d/2 or 24"

min. stirups

no stirups
A vfy d φ Avfy
s= Vu = (v u−φv c) b

50b w
−Vc

A v fy
φ
distance from support

s =
Figure 3.8: Summary of ACI Code Requirements for Shear

3.5 Examples

Example 3-1: Shear Design

b = 12 in.; d=22 in.; wu = 8.8 k/ft; L= 20 ft.; As = 3# 11; fc = 4 ksi; fy = 40 ksi;
Design vertical stirrup
Solution:

1. At support: Vu = 8.8 (20)


2 = 88 k and vu =
88
(12)(22) = .333 ksi

2. At d from support Vu = 88 − 22
12 (8.8) = 71.9 k and vu = 71.9
(12)(22) = .272 ksi
 √
3. vc = 2 fc = 2 4, 000 = 126 psi; φvc = (0.85)(126) = 107.1 psi

4. vc = 4 fc = 2(126) = 252 psi; φv2 c = 53.6 psi
 √
5. vu − vc = 272 − 126 = 146 psi < 4 fc

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
3–8

psi d
SHEAR

333
Vu

272

107.1 φv c

φv c
53.6
2
x

19"
min. reinforcement no reinforcement

38.6"

6. vu − φvc = 0 ⇒ 333
(10)(12) x = 107.1 ⇒ x = 38.6 in = 3.2 ft from mid-span
φvc
7. vu − 2 =0⇒ 333
(10)(12) x = 53.6 ⇒ x = 19.3 in = 1.6 ft

8. Selecting #3 bars, Av = 2(.11) = .22 in2



Av f y (.22)(40,000)
smax = 50bw = (50)(12) = 14.66 in
d 22
smax = 11 in (3.16)
2 = 2 = 11 in

9. at support
Av fy d φAv fy
s = = (3.17-a)
− Vc u − φvc )b
Vu (v
φ
(.85)(.22)(40, 000)
= (3.17-b)
(272 − 107.1)(12)
= 3.78 in (3.17-c)
(3.17-d)

3.6 Shear Friction

15 Previous design procedure was applicable to diagonal tension cracks (where tension was
induced by shear), for those cases where we do have large pure shear, Fig. 3.9 use shear friction
concept.
16The crack for which shear-friction reinforcement is required may not have been caused by
shear. However once the crack has occurred a shear transfer mechanism must be provided, Fig.

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
3.6 Shear Friction 3–9

#7 Vu
N uc
An=
φfy
weld
Nuc
A n part of A v f

close sriru
(usually #3)
Avf
assumed crack
+ shear plane
remainder of A v f
assumed crack
Vu

Figure 3.9: Corbel

Vn Vn
Vn

crack
crack separation

µ A vf f y
due to slip

Vn Vn

Shear−transfer
reinforcement A fy
vf
Avf f y Avf f y
2 2

Figure 3.10: Shear Friction Mechanism

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
3–10 SHEAR

3.10. The shear friction theory is based on the assumption that a crack will occur and then
reinforcement across it will resist relative displacement along the crack.
17 If we assume separation to be sufficient⇒ steel will yield
Vn = µAvf fy (3.18)

18 If the shear reinforcement is inclined with respect to the crack, Fig. 3.11
Tsin α f
Tcos α f
assumed crack

applied shear=Vn

A vf fy
µC

C=Tsin α f
αf
T

Figure 3.11: Shear Friction Across Inclined Reinforcement

19Component of tensile force in reinforcement gives rise to compression force at interface C ⇒


µc vertical force due to friction;
 
Vn = T cos αf + µC Vn = T (cos αf − µ sin αf )
Vn = Avf fy (cos αf + µ sin (3.19-a)
αf
C = T sin αf T = Avf fy

20 Note: Vu = φVn and φ = 0.85


21 The preceding equation can be rewritten as
Vu
Avf = (3.20)
φµfy
Vu
Avf = ACI − 11.27 (3.21)
φfy (cos αf + µ sin αf )

22 ACI-11.7.4.3 specifies µ as such that


concrete cast monolithically µ = 1.4λ
concrete against hardened concrete µ = 1.0λ
concrete against steel µ = 0.7λ
where λ = 1.0 for normal weight concrete and λ = .75 for lightweight concrete. and
$
0.2fc Ac
Vn < (3.22)
800Ac
Victor Saouma Mechanics and Design of Reinforced Concrete
Draft
3.7 Brackets and Corbels

and Ac ( in2 ) is the area of concrete resisting shear.


3–11

Example 3-2: Shear Friction

Design reinforcement needed at the bearing region of a precast beam 14” wide & 28” deep
supported on a 4” bearing pad. Vu = 105k, horizontal force due to restraint, shrinkage, creep
is 0.3 Vu

possible crack
A vf
20
3#6
15

N uc
2#6 15

Vu N uc
4"
24" Vuc

Solution:

1. Assume all the shear Vu will be acting parallel to crack (small angle 20◦ )
2. Assume all Vu is parallel to crack ⇒ required Avf = Vu
φfy µ = 105
(0.85)(60)(1.4) = 1.47 in2
(0.3)(105)
3. As = N 2
φfy = (0.85)(60) = 0.62 in for horizontal force
ac

⇒ As = Avf + An = 1.47 + 0.62 in2 = 2.09 in2 ⇒ use 5# 6 (As = 2.20 in2 )
4. Note: ACI 11-9-3-4 Nuc > 0.2 Vu for Corbels;

3.7 Brackets and Corbels

23 Nu might be due to shrinkage, prestressing · · ·

24 Design based on truss analogy


25 A.C.I. provisions (Chapter 11)
a
1. For d < 12 , use shear friction theory
a
2. For d > 1, use ordinary beam theory
3. For 1
2 ≤ a
d ≤1
% & % 
Nuc α Nu 3 
Vn = [6.5 − 5.1 ](1 − 0.5 ) 1 + [64 + 160 ( ) ]ρ fc bw d (3.23)
Vu d Vu

where ρ = A??s ; and ρ ≤ 0.13 ffyc ; N
Vu not to be taken < 0.20 in calculating vu ; Nu = (+ve)
u

compression, and (-ve) tension; Ah < As also Ah ≥ 0.50As distributed uniformly; thru
fc
3 d adjacent to As ; ρ = bd ≥ .04 fy .
2 As

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
3–12

3.8 Deep Beams


SHEAR

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft

Chapter 4

CONTINUOUS BEAMS

4.1 Continuity

1 R/C bldgs constructions commonly have floor slabs, beams, girders and columns continuously
placed to form a monolithic system

Figure 4.1: Continuous R/C Structures

2
+ve
In a continuous system, load must be placed in such a way to maximize desired effect (Mmax
−ve V
Mmax max , Fig. 4.2

Max +ve M @
AB_CD_EF
A B C D E F G

Max -ve M @ B

Min -ve @ B

Max -ve @ C

Min -ve @ C

Max -ve @ D

Min -ve @ D

Figure 4.2: Load Positioning on Continuous Beams

3 Given the moment diagram for various load cases, a designer should draw the moment
enveloppe and design for the maximum negative and positive moments (eventhough they may
not be caused by the same load case).
Draft
4–2

4.2 Methods of Analysis


CONTINUOUS BEAMS

4 Two approaches:

1. Detailed analysis

(a) Moment distribution


(b) Computer analysis

2. Approximate (but conservative) based on ACI 8.3.3 moment coefficients

4.2.1 Detailed Analysis

5 Refer to CVEN3525/3535/4525

4.2.2 ACI Approximate Method

6 This method, Fig. 4.3 can be used if:

1. 2 or more spans

2. Spans are approximately equals, and the larger of adjacent ones not greater than the
shorter by more than 20%

3. Loads are uniformably distributed

4. LL < 3DL

5. Prismatic members

Positive Moment
End Spans
1 2
Continuous end unrestrained 11 wu Ln
1 2
Continuous end integral with support 14 wu Ln
1 2
Interior spans 16 wu Ln
Negative Moment
Negative moment at exterior face of first of first interior support
1 2
Two spans 9 wu Ln
1 2
> Two spans 10 wu Ln
1 2
Negative moment at other faces of interior support 11 wu Ln
...................................... ......
Shear
Shear in end member at face of first interior support 1.15 wu2Ln
wu Ln
Shear at face of all other supports 2

where wu is the factored load, and Ln is the cleas span.


7 These moment coefficients take into account some inelastic action.
8 They are conservative compared to an exact analysis.

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
4.2 Methods of Analysis 4–3

Figure 4.3: ACI Approximate Moment Coefficients

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
4–4 CONTINUOUS BEAMS

C
L column
C
L column
CL span
VaL
111
000 VaL
000
111
000
111 3
6
V
000
111
000
111
000
111 C
VaL VaL
L beam 2 VaL 3
aL 6
2
Column width aL
L
2
Moment curve based on prismatic member
aL
1111111111111111111111111
0000000000000000000000000
0000000000000000000000000
1111111111111111111111111
VaL
6
2
0000000000000000000000000
1111111111111111111111111
0000000000000000000000000
1111111111111111111111111
Adjusted Moment Curve
0000000000000000000000000 L
1111111111111111111111111 C beam
0000000000000000000000000
1111111111111111111111111
0000000000000000000000000
1111111111111111111111111
0000000000000000000000000
1111111111111111111111111
0000000000000000000000000
1111111111111111111111111
0000000000000000000000000
1111111111111111111111111
0000000000000000000000000 CL beam
1111111111111111111111111
0000000000000000000000000
1111111111111111111111111
0000000000000000000000000
1111111111111111111111111
0000000000000000000000000
1111111111111111111111111
0000000000000000000000000
1111111111111111111111111
0000000000000000000000000
1111111111111111111111111
0000000000000000000000000
1111111111111111111111111
0000000000000000000000000
1111111111111111111111111
0000000000000000000000000
1111111111111111111111111
0000000000000000000000000
1111111111111111111111111
0000000000000000000000000
1111111111111111111111111

Figure 4.4: Design Negative Moment

4.3 Effective Span Design Moment

9 Negative moments should be the one at the face of the columns which is, Fig. 4.4

Vb
Md−ve ≈ Mmax
−ve
− (4.1)
3

10 This can substantially reduce high M −ve .

4.4 Moment Redistribution


4.4.1 Elastic-Perfectly Plastic Section

11 Let us consider a uniformly loaded rigidly connected beam, Fig. 4.5


2
WL
W 24
1
0
0
1 11
00
00
11 2
+
2
0
1 00
11 WL − − WL
12 12

Figure 4.5: Moment Diagram of a Rigidly Connected Uniformly Loaded Beam

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
4.4 Moment Redistribution

M
4–5

Mp X

Curvature
Φy Φu

Figure 4.6: Moment Curvature of an Elastic-Plastic Section

12 The beam has an elastic plastic moment curvature relation, Fig. 4.6
13 |M −ve | > |M +ve | as w , M −ve → Mp first ⇒
wL2 12Mp
= Mp ⇒ w =
12 L2

14 Thus we will have a plastic hinge at the support however this is not synonymous with collapse.
15Collapse or failure occurs when we have a mechanism or 3 adjacent hinges (plastic or other-
wise). This can be easily determined from statics, Fig. 4.7
M
p

M p
M p

Figure 4.7: Plastic Moments in Uniformly Loaded Rigidly Connected Beam

wu L2
2Mp = 8
16Mp
wu = L2

16 Thus capacity was increased 33% after first plastic hinge occurred.
17This is accompanied by large rotation of the plastic hinges at the supports, and when com-
pared with the linear elastic solution M −ve  and M +ve 
18 The section must be designed to accomodate this rotation.

4.4.2 Concrete

19Concrete is brittle hence by itself no appreciable plastic deformation can occur, however in
R/C, Fig. 4.8
20 If certain rotation capacity exists (i.e., if ρ − ρ is low) M is controlled by yielding of the steel
while the concrete strain is still low compared to 0.003 ⇒ reserve rotation capacity θu − θy is
then available for a redistribution of moment to occur before ε → 0.003

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
4–6

ε ce
CONTINUOUS BEAMS

ε ce
fc fc

kd c

d−kd d−c

Asf y Asf y
ε s= ε y ε s> ε y
.003
M u
Steel yielding
εc
φ
M y

M cr
First crack

θcr θ y θu Strain caused by


moment redistribution θy
Unit rotation
θu
εy

Figure 4.8: Plastic Redistribution in Concrete Sections

21M −ve moment at support of continuous flexural members calculated by elastic theory can
be decreased by no more than

ρ − ρ
∆M = 20(1 − )% ACI 8.4.1 (4.2)
ρb


where ρb = 0.85β1 ffyc ( 87+f
87
y
) provided that

1. Moments are exactly determined (i.e., not ACI coefficients)

2. ρ or ρ − ρ < 0.5ρb

22 M +ve must be increased accordingly.


23 This capacity to redistribute moments (reduce M −ve and increase M +ve ) is a characterisitc
of ductile members.
24 Earthquake resistant structures must have a certain ductility to absorb the lateral oscillating
load ⇒ large amount of reinforcement at the joints.

Example 4-1: Moment Redistribution

Determine the moment redistribution for the following singly reinforced beam with ρ = 0.5ρb
2 2
WL WL
24 20

+ +
2 2
2 2 −
WL − − WL 0.9 WL − 0.9 W L
12 12 12 12

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
4.5 Buildings

Solution:
4–7

From above, amout of redistribution


ρ−ρ
∆M = 20(1 − ρb )%
= 20(1 − 0.5) = 10%
2
M −ve = 0.9 wL
12
2 wL2
M +ve = 1.2 wL
24 = 20

4.5 Buildings

25 Building types, Table 4.1

Structural System Number of Stories


Frame Up to 15
Shear Wall-Frame up to 40
Single framed tube up to 40
Tube in Tube up to 80

Table 4.1: Building Structural Systems

26 We analyse separately for vertical and horizontal loads.

Vertical loads: DL and LL. This is typically done for a floor, through a grid analysis. No
need to model the entire structure. We can use

ACI Approximate equations


Exact (Moment distribution, computer)

Lateral laod: WL, EL. This requires the analysis of a 2D or 3D frame. Two approaches:

Approximate method: Portal method, or cantilever method.


Exact Moment distribution, computer.

27 Recommended analysis/design procedures

1. Use ACI approximate equations for the design of the slab. Then, there is no need to worry
about optimal placement of load to maximize positive or negative moments, or moment
redistribution.

2. Once the slab is designed, use exact method for beams, girders. Reduce negative moments.

3. Tabulate maximum +ve and -ve moments for each beam.

4. Determine the column loads, tabulate.

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
4–8

5. Can use approximate or “exact” method of analysis for frames. Tabulate results.
CONTINUOUS BEAMS

6. Add maximum positive and negative moments due to vertical and lateral loads.

7. Design accordingly.

28 A block diagram for the various steps is shown in Fig. 4.9

E-W SLAB N-S BEAM E-W GIRDER N-S GIRDER


L b L b L L

h h h b
hf

DL w0 LL w0 PW PW WL w0 PW w0 WL

wu wu wu wu

M V M V
M V R M V R
L Span
hf Slab thickness N
h Beam/girder depth
M Flexure
V
R
Shear
Reation
Col
PW Partition wall W E
WL Wind load
W0
Wa
Self weight
Total factored load
Fou
Col Column
Fou Foundation S
R/C Bldg Design

Figure 4.9: Block Diagram for R/C Building Design

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft

Chapter 5

SERVICEABILITY

1 So far we have focused on the ultimate structural behaviour (failure), Vu & Mu , i.e the strength
of a member.
2 It is important to also control the behaviour of structural elements under service load (unfac-

tored)

1. Cracking

2. Deflection

5.1 Control of Cracking

3 As σy , εy ⇒ larger crack width is associated with large fy . This is why the ACI code

places a limitation on max fy = 80ksi. (ACI 9.4)


4 The concern is not the # of crack (we can not control it) but rather the crack width.
5 Crack width should be minimized because:

1. Appearance

2. Corrosion of steel

3. Redistributions of internal stresses

4. Effect on deflection

6 The controlling parameters are:

1. Surface of the reinforcing bar

(a) Round & smooth ⇒ few wide cracks (bad)


(b) Irregular & deformed ⇒ many small cracks (better)

2. Steel stress

3. Concrete cover
Draft
5–2

4. Distribution of steel over the tensile zone of concrete ←


SERVICEABILITY

7 Based on purely experimental research, the following emperical relation was determined, Fig.
5.1:

w = .076βfs 3 dc A Gergely & Lutz Eq. (5.1)

where
w width in 1/1,000 in
fs Steel service stress ksi (if not computed can be assumed as 0.6 fy )
dc Thickness of concrete cover measured from tension face to center of bar
closest to this face, in.
h2
β h1
A Area of concrete surrounding one bar = Total effective tensile area in2
# of bars

Neutral Axis

h
111
000 h1 2
000
111
000
111 Steel Centroid
2y
000
111
y 000
111
d
c
w

Figure 5.1: Crack Width Equation Parameters

8 ACI

1. Expresses the crack width indirectly by z where

w 
z= = fs 3 dc A (ACI 10.6.4) (5.2)
.076β

and assumes β = h2
h1 = 1.2 ⇒ w = .091z
Interior beams z ≤ 175 (w = .016 in)
Exterior beams z ≤ 145 (w = .013 in)
2. Only deformed bars can be used

3. Bars should be well distributed in tension zone

4. fy < 80ksi

5. In lieu of an accurate evaluation, fs = 0.6fy .

9 Maximum acceptable crack width (ACI Committee 224).

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
5.1 Control of Cracking

Exposure wmax (in.)


5–3

dry air, or protective membrane .016


humidity, moist air, soil .012
deicing chemicals .007
seawater, salt .006
water retaining structures .004

Example 5-1: Crack Width

fc = 3,000 ksi; fy = 40 ksi; As = 4 # 8; LL = 2.44 k/ft; DL = 1.27 k/ft; L = 15 ft.;


Determine z and crack width
22.5"

20"

11.5"

Solution:


1. w = .076βfs 3 dc A

2. Ec = 57 3, 000 = 3, 120 ksi
29×103
3. n = 3,120 = 9.29

b(kd)2
4. 2 − nAs (d − kd) = 0 ⇒ k = .393 ⇒ j = 1 − k
3 = .869 ⇒ kd = 7.85 in
2
5. fs = AM
s jd
⇒ fs = (1.27+2.44)(15) (12)
8(3.14)(.869)(20) = 22.9 ksi
Note that ACI allows 0.6fy = (0.6)(40) = 24 ksi conservative
22.5−7.85 14.65
6. β = 20−7.85 = 12.15 = 1.206 (note ACI stipulates 1.2)
(2.5)(2)(11.5)
7. A = 4 = 14.38 in2
 1
8. w = (.076)(1.206)(22.9) 3 (2.5)(14.38) 1,000 = .00696 in .
√ 
9. or z = fs3 dc A = (22.9) 3 (2.5)(14.38) = 75.64

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
5–4

5.2 Deflections
SERVICEABILITY

10 ACI Code Sect. 9.5


11 Every structural design must satisfy requirements of strength, stiffness & stability
12 With the increased usuage of: a) high strength material (resulting in smaller cross section)
& b) use of refined design methods, we can no longer rely on the factor of safety to “take care”
of deflection, ⇒ we but must detemine it
13 Deflection should be controlled because of:

1. Visually unacceptable

2. Possible ponding of water

3. Cracking in partition walls

4. Functional difficulties (windows, doors, etc · · ·)

5. Machine misalignment

6. Vibration

14 Deflection are computed for service loads only


15 Both long term & short term deflection should be considered.
16 As a rule of thumb, deflections seldom control if ρ < 0.5ρb

5.2.1 Short Term Deflection


f (w,L) 5wL4
17 In general δ = EI , i.e., uniform load over simply supported beam in 384EI

18 f (w, l) and E are known, but how do we determine I?, Fig. 5.2

Ε cΙ ut Ε cΙ e 1 Ε cΙ e 2 Ε cΙ cr

Μ2

Μ1

Μ cr

Α B Α B Α B Α B Α B ∆ ∆
1 2

Figure 5.2: Uncracked Transformed and Cracked Transformed X Sections

19 It would be too complicated to have I = I(M )

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
5.2 Deflections

20 ACI recommends to use a weighted average expression for I → Ieff


5–5

  '   (
Mcr 3 Mcr 3
Ieff = Ig + 1 − Icr (ACI 9.5.2.3) (5.3)
Ma Ma

where
Ieff ≤ Ig
Mcr = fr ygb
I

fr = 7.5 fc
and Ma is the maximum (service) moment at stage in which deflection is computed
21 For continuous beams average

Ieff = 0.70Im + 0.15(Ie1 + Ie2 )

22 For beams with one end continuous Ieff = 0.85Im + 15(Icon ) where Im , Ie are the moment of

inertia at the middle and the end respectively.


23 Note that Ig may be substituted for Iut
24Deflection evaluation is a nonlinear problem, as w  M  Mcr
Ma  Ieff  and for a continu-
ous beam $
5 wL4 w ∆
∆=
384 EI I ∆

5.2.2 Long Term Deflection

δt

δ inst.

Figure 5.3: Time Dependent Deflection

25 Creep coefficient:
εf
Cc = εi
σ σ Ec
Ect = ε = εi (1+Cc ) = 1+Cc

⇒ Creep tends to reduce the elastic modulus of concrete, Fig. 5.4


26 From Strain diagram:

1. Steel strain remains unchanged

2. As concrete undergoes creep, the N.A. moves down ⇒ larger area of concrete is under
compression but since C = T ⇒ stress in concrete is slightly reduced

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
5–6 SERVICEABILITY

fci
b εi εt
fct
Cracked
elastic φi
neutral axis d
φt
kd

As A s fs

εs

Figure 5.4: Time Dependent Strain Distribution

3. But since C is now lower and we still satisfy Mext = Mint both stresses in steel & concrete
must increase with time

27 According to ACI section 9.5.2.5:

1. Additional long term deflection δ t

δt = δi × λ (5.4)

where
ξ
λ = 1+50ρ
 
As
ρ = bd
and

Time (months) 3 6 12 ≥ 60
ξ 1.0 1.2 1.4 2.0

Thus compressive reinforcement can substantially reduce long term deflections

δtotal = δinitial (1 + λ) (5.5)

A B C
LL short
DL sustained

1111
0000 1111
0000
0000
1111 1111
0000

Figure 5.5: Short and long Term Deflections

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
5.2 Deflections

28 Short and long term deflections, Fig. 5.5


5–7

A → δi,sust
B → δi,sust + δt,sust
C → δsust + δi,short

and

δi, short = δi, sust + short − δi, sust (5.6)


     
Ieff (DL+LL) Ieff (DL)

29 ACI max. deflections (ACI 9.5.2.6)

L
Flat roof not supporting nonstructural elements likely to be damaged δi,sh < 180
L
Floors not supporting nonstructural elements likely to be damaged δi,sh < 360
L
Roofs or floors supporting nonstructural elements likely to be damaged δt,sust + δi,sh < 480
L
Floors not supporting nonstructural elements not likely to be damaged δt,sus + δi,sh < 240

Example 5-2: Deflections

b = 11.5 in.; h = 22.5 in,; d = 20 in.; As = 4 # 8; fc = 3,000 psi; fy = 40 ksi; DL = 1.27
k/ft; LL = 2.44 k/ft; L = 15 ft.

1. Determine the short term deflection

2. Find the creep portion of the sustained load deflection & immediate live load deflections

Solution:

1. δi, short = δi,short + sust − δi, sust


      
2.44 1.27 1.27

2. Moment of inertias:

3 
3 
Ieff = Mcr
Ma Ig + 1 − Mcr
Ma Ict
bh3 (11.5)(22.5)3
Ig = 12 = 12 = 10, 916 in4

3. to find Ict , need to locate N.A @ service

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
5–8 SERVICEABILITY

11.5"

7.85"

20"
12.15"

b(kd)2
− nAs (d − kd) = 0 ⇒ k = .393 ⇒ kd = 7.85 in
2
(11.5)(7.85)3  2
Ict = + (11.5)(7.85) 7.85 + (9.29) (3.14)(12.152 ) = 6, 130 in4
12 2      
√ n As
fr = 7.5 3, 000 = 410.8 psi
fI
Mcr = rybg
(410.8)(10,916)
= 11.25 = 33.2 k.ft = 399 k.in

4. Ma for sustained load


(1.27)(15)2 (12)
Masust = = 428.6 k.in = 35.72 k.ft
8
5. Ma for sustained and short load
(1.27 + 2.44)(15)2 (12)
Masust+short = = 1, 252 k.in = 104 k.ft
8
6. Moment of inertias
  )  33.2 3*
33.2 3
Ieff, sust + short = (10, 916) + 1 − 104.3 (6, 130) = 6, 209 in4
104.3
 33.2 3 )  33.2 3 *
Ieff, sust = 35.7 (10, 916) + 1 − 35.7 (6, 130) = 9, 993 in4

7. Deflections √
E = 57 3, 000 = 3, 120 ksi
5 wL4
δ = 384 EI
5 (1.27+2.44)[(15)(12)]4
δi, short + sust = 384 (3,120)(6,209) = .218 in
4
5 (1.27)[(15)(12)]
δi, sust = 384 (3,120)(9,993) = .046 in
δi = .218 − .046 = .172 in
8. δcreep = λδi, sust
2.
λ= = 2. ⇒ δcreep = (2)(.046) = .092 in
1+0

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft

Chapter 6

APPROXIMATE FRAME
ANALYSIS

1 Despite the widespread availability of computers, approximate methods of analysis are justi-

fied by
1. Inherent assumption made regarding the validity of a linear elastic analysis vis a vis of
an ultimate failure design.

2. Ability of structures to redistribute internal forces.

3. Uncertainties in load and material properties

2 Vertical loads are treated separately from the horizontal ones.


3 We use the design sign convention for moments (+ve tension below), and for shear (ccw +ve).
4 Assume girders to be numbered from left to right.
5 In all free body diagrams assume positivee forces/moments, and take algeebraic sums.

6.1 Vertical Loads

6 The girders at each floor are assumed to be continuous beams, and columns are assumed to

resist the resulting unbalanced moments from the girders.


7 Basic assumptions
1. Girders at each floor act as continous beams supporting a uniform load.

2. Inflection points are assumed to be at

(a) One tenth the span from both ends of each girder.
(b) Mid-height of the columns

3. Axial forces and deformation in the girder are negligibly small.

4. Unbalanced end moments from the girders at each joint is distributed to the columns
above and below the floor.
Draft
6–2

8
APPROXIMATE FRAME ANALYSIS

Based on the first assumption, all beams are statically determinate and have a span, Ls
equal to 0.8 the original length of the girder, L. (Note that for a rigidly connected member, the
inflection point is at 0.211 L, and at the support for a simply supported beam; hence, depending
on the nature of the connection one could consider those values as upper and lower bounds for
the approximate location of the hinge).
9 End forces are given by
Maximum positive moment at the center of each beam is, Fig. 6.1
w
rgt
lft M
M
rgt
V
lft
V

0.1L 0.1L
0.8L
L

111
000
000
0000
1111
111 0000
1111
1
0
0
1 11
00
00
11
0
1 00
11
0
1 00
11
0
1 00
11

Figure 6.1: Approximate Analysis of Frames Subjected to Vertical Loads; Girder Moments

1 1
M + = wL2s = w (0.8)2 L2 = 0.08wL2 (6.1)
8 8

Maximum negative moment at each end of the girder is given by, Fig. 6.1

w w
M lef t = M rgt = − (0.1L)2 − (0.8L)(0.1L) = −0.045wL2 (6.2)
2 2

Girder Shear are obtained from the free body diagram, Fig. 6.2

wL wL
V lf t = V rgt = − (6.3)
2 2

Column axial force is obtained by summing all the girder shears to the axial force transmit-
ted by the column above it. Fig. 6.2

rgt
P dwn = P up + Vi−1 − Vilf t (6.4)

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
6.1 Vertical Loads 6–3

above
P

rgt lft
V i−1 Vi

below
P

Figure 6.2: Approximate Analysis of Frames Subjected to Vertical Loads; Column Axial Forces

h/2

h/2
above
M col
lft lft rgt
M rgt
Mi−1 Mi M
i−1
i

rgt lft rgt


Vlft Vi−1 V
i
V
i
i−1
Mbelow
col
Li−1 Li
h/2

h/2

Figure 6.3: Approximate Analysis of Frames Subjected to Vertical Loads; Column Moments

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
6–4 APPROXIMATE FRAME ANALYSIS

Column Moment are obtained by considering the free body diagram of columns Fig. 6.3

rgt
M top = Mabove
bot
− Mi−1 + Milf t M bot = −top (6.5)

Column Shear Points of inflection are at mid-height, with possible exception when the columns
on the first floor are hinged at the base, Fig. 6.3

M top
V = h
(6.6)
2

Girder axial forces are assumed to be negligible eventhough the unbalanced column shears
above and below a floor will be resisted by girders at the floor.

6.2 Horizontal Loads

10 We must differentiate between low and high rise buildings.

Low rise buidlings, where the height is at least samller than the hrizontal dimension, the
deflected shape is characterized by shear deformations.

High rise buildings, where the height is several times greater than its least horizontal di-
mension, the deflected shape is dominated by overall flexural deformation.

6.2.1 Portal Method

11Low rise buildings under lateral loads, have predominantly shear deformations. Thus, the
approximate analysis of this type of structure is based on

1. Distribution of horizontal shear forces.

2. Location of inflection points.

12 The portal method is based on the following assumptions

1. Inflection points are located at

(a) Mid-height of all columns above the second floor.


(b) Mid-height of floor columns if rigid support, or at the base if hinged.
(c) At the center of each girder.

2. Total horizontal shear at the mid-height of all columns at any floor level will be dis-
tributed among these columns so that each of the two exterior columns carry half as
much horizontal shear as each interior columns of the frame.

13 Forces are obtained from

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
6.2 Horizontal Loads 6–5

H/2 H H H/2

Figure 6.4: Approximate Analysis of Frames Subjected to Lateral Loads; Column Shear

Column Shear is obtained by passing a horizontal section through the mid-height of the
columns at each floor and summing the lateral forces above it, then Fig. 6.4

ext F lateral
V = V int = 2V ext (6.7)
2No. of bays

Column Moments at the end of each column is equal to the shear at the column times half
the height of the corresponding column, Fig. 6.4

h
M top = V M bot = −M top (6.8)
2

Girder Moments is obtained from the columns connected to the girder, Fig. 6.5

h/2

h/2
above
M col
lft rgt lft rgt
M i−1 M i−1 Mi Mi

rgt rgt
lft
Vi−1 V Vlft Vi
i−1 i
below
M col
Li−1/2 Li−1/2 Li /2 Li /2
h/2

h/2

Figure 6.5: Approximate Analysis of Frames Subjected to Lateral Loads; Girder Moment

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
6–6 APPROXIMATE FRAME ANALYSIS

Milf t = Mcol
above
− Mcol
below rgt
+ Mi−1 Mirgt = −Milf t (6.9)

Girder Shears Since there is an inflection point at the center of the girder, the girder shear
is obtained by considering the sum of moments about that point, Fig. 6.5

2M
V lf t = − V rgt = V lf t (6.10)
L

Column Axial Forces are obtained by summing girder shears and the axial force from the
column above, Fig. ??
above
P

rgt lft
V i−1 Vi

below
P

Figure 6.6: Approximate Analysis of Frames Subjected to Lateral Loads; Column Axial Force

P = P above + P rgt + P lf t (6.11)

Example 6-1: Approximate Analysis of a Frame subjected to Vertical and Horizontal Loads

Draw the shear, and moment diagram for the following frame. Solution:

Vertical Loads

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
6.2 Horizontal Loads

0.25 k/ft
6–7

15 k
5 12 6 0.5 k/ft13 7 14 8
14
30 k
9 10 11
1 2 3 4 16
11
00 11
00 11
00 11
00
20’ 30’ 24’

Figure 6.7: Example; Approximate Analysis of a Building

1. Top Girder Moments


lf t
M12 = −0.045w12 L212 = −(0.045)(0.25)(20)2 =− 4.5 k.ft
cnt
M12 = 0.08w12 L212 = (0.08)(0.25)(20)2 = 8.0 k.ft
rgt lf t
M12 = M12 =− 4.5 k.ft
lf t
M13 = −0.045w13 L213 = −(0.045)(0.25)(30)2 =− 10.1 k.ft
cnt
M13 = 0.08w13 L213 = (0.08)(0.25)(30)2 = 18.0 k.ft
rgt lf t
M13 = M13 =− 10.1 k.ft
lf t
M14 = −0.045w14 L214 = −(0.045)(0.25)(24)2 =− 6.5 k.ft
cnt
M14 = 0.08w14 L214 = (0.08)(0.25)(24)2 = 11.5 k.ft
rgt lf t
M14 = M14 =− 6.5 k.ft

2. Bottom Girder Moments


M9lf t = −0.045w9 L29 = −(0.045)(0.5)(20)2 =− 9.0 k.ft
M9cnt = 0.08w9 L29 = (0.08)(0.5)(20)2 = 16.0 k.ft
M9rgt = M9lf t =− 9.0 k.ft
lf t
M10 = −0.045w10 L210 = −(0.045)(0.5)(30)2 =− 20.3 k.ft
cnt
M10 = 0.08w10 L210 = (0.08)(0.5)(30)2 = 36.0 k.ft
rgt lf t
M10 = M11 =− 20.3 k.ft
lf t
M11 = −0.045w12 L212 = −(0.045)(0.5)(24)2 =− 13.0 k.ft
cnt
M11 = 0.08w12 L212 = (0.08)(0.5)(24)2 = 23.0 k.ft
rgt lf t
M11 = M12 =− 13.0 k.ft

3. Top Column Moments

M5top = lf t
+M12 =− 4.5 k.ft
M5bot = −M5top = 4.5 k.ft
M6top = rgt
−M12 lf t
+ M13 = −(−4.5) + (−10.1) =− 5.6 k.ft
top
M6bot = −M6 = 5.6 k.ft
M7top = rgt
−M13 lf t
+ M14 = −(−10.1) + (−6.5) =− 3.6 k.ft
M7bot = −M7top = 3.6 k.ft
M8top = rgt
−M14 = −(−6.5) = 6.5 k.ft
M8bot = −M8top =− 6.5 k.ft

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
6–8

4. Bottom Column Moments


APPROXIMATE FRAME ANALYSIS

M1top = +M5bot + M9lf t = 4.5 − 9.0 =− 4.5 k.ft


M1bot = −M1top = 4.5 k.ft
M2top = +M6bot − M9rgt + M10 lf t
= 5.6 − (−9.0) + (−20.3) =− 5.6 k.ft
top
M2bot = −M2 = 5.6 k.ft
M3top = rgt
+M7bot − M10 + M11lf t
= −3.6 − (−20.3) + (−13.0) = 3.6 k.ft
top
M3bot = −M3 =− 3.6 k.ft
M4top = rgt
+M8bot − M11 = −6.5 − (−13.0) = 6.5 k.ft
M4bot = −M4top =− 6.5 k.ft

5. Top Girder Shear


lf t (0.25)(20)
V12 = w122L12 = 2 = 2.5 k
rgt lf t
V12 = −V12 =− 2.5 k
lf t (0.25)(30)
V13 = w132L13 = 2 = 3.75 k
rgt lf t
V13 = −V13 =− 3.75 k
lf t (0.25)(24)
V14 = w142L14 = 2 = 3.0 k
rgt lf t
V14 = −V14 =− 3.0 k
6. Bottom Girder Shear
V9lf t = w92L9 = (0.5)(20)
2 = 5.00 k
V9rgt = −V9lf t =− 5.00 k
lf t
V10 = w102L10 = (0.5)(30)
2 = 7.50 k
rgt lf t
V10 = −V10 =− 7.50 k
lf t
V11 = w112L11 = (0.5)(24)
2 = 6.00 k
rgt lf t
V11 = −V11 =− 6.00 k

7. Column Shears
M5top −4.5
V5 = H5 = 14 = − 0.64 k
2 2
M6top −5.6
V6 = H6 = 14 = − 0.80 k
2 2
M7top 3.6
V7 = H7 = 14 = 0.52 k
2 2
M8top 6.5
V8 = H8 = 14 = 0.93 k
2 2
M1top −4.5
V1 = H1 = 16 = − 0.56 k
2 2
M2top −5.6
V2 = H2 = 16 = − 0.70 k
2 2
M3top 3.6
V3 = H3 = 16 = 0.46 k
2 2
M4top 6.5
V4 = H4 = 16 = 0.81 k
2 2

8. Top Column Axial Forces


lf t
P5 = V12 = 2.50 k
rgt lf t
P6 = −V12 + V13 = −(−2.50) + 3.75 = 6.25 k
rgt lf t
P7 = −V13 + V14 = −(−3.75) + 3.00 = 6.75 k
rgt
Victor Saouma P8 = −V14 Mechanics and Design of=Reinforced
3.00 k Concrete
Draft
6.2 Horizontal Loads 6–9

0.25K/ft

5 12 6 13 7 14 8
0.50K/ft 14’
9 10 11
1 2 3 4 16’

20’ 30’ 24’

+8.0’k +18.0’k +11.5’k


-4.5’k -4.5’k
-10.1’k -10.1’k -6.5’
k
-6.5’k
+16.0’k +23.0’k
+32.0’k
-9.0’k -9.0’k
k k-13.0’ k
-13.0’k
-20.2’ -20.2’

-4.5’k -5.6’k +3.6’k +6.5’k

+4.5’k +5.6’k -3.6’k -6.5’k


-4.5’k -5.6’k +3.6’k +6.5’k

+4.5’k +5.6’k -3.6’k -6.5’k

Figure 6.8: Approximate Analysis of a Building; Moments Due to Vertical Loads

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
6–10 APPROXIMATE FRAME ANALYSIS

+2.5K +3.75K +3.0K

-2.5K -3.75K
K
-3.0K
+5.0 K +7.5 +6.0 K

-5.0K -6.0K
-7.5K

-0.64K -0.80K +0.51K +0.93K

-0.56K -0.70K +0.45K +0.81K

Figure 6.9: Approximate Analysis of a Building; Shears Due to Vertical Loads

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
6.2 Horizontal Loads

9. Bottom Column Axial Forces


6–11

P1 = P5 + V9lf t = 2.50 + 5.0 = 7.5 k


rgt
P2 = P6 − V10 + V9lf t = 6.25 − (−5.00) + 7.50 = 18.75 k
rgt lf t
P3 = P7 − V11 + V10 = 6.75 − (−7.50) + 6.0 = 20.25 k
rgt
P4 = P8 − V11 = 3.00 − (−6.00) = 9.00 k

Horizontal Loads, Portal Method

1. Column Shears
15
V5 = (2)(3) = 2.5 k
V6 = 2(V5 ) = (2)(2.5) = 5k
V7 = 2(V5 ) = (2)(2.5) = 5k
V8 = V5 = 2.5 k
15+30
V1 = (2)(3) = 7.5 k
V2 = 2(V1 ) = (2)(7.5) = 15 k
V3 = 2(V1 ) = (2)(2.5) = 15 k
V4 = V1 = 7.5 k
2. Top Column Moments
(2.5)(14)
M5top = V12H5 = 2 = 17.5 k.ft
M5bot = −M5top =− 17.5 k.ft
(5)(14)
M6top = V62H6 = 2 = 35.0 k.ft
M6bot = −M6top =− 35.0 k.ft
V up H (5)(14)
M7top = 7 2 7 = 2 = 35.0 k.ft
M7bot = −M7top = − 35.0 k.ft
V up H (2.5)(14)
M8top = 8 2 8 = 2 = 17.5 k.ft
M8bot = −M8top = − 17.5 k.ft
3. Bottom Column Moments
V dwn H (7.5)(16)
M1top = 1 2 1 = 2 = 60 k.ft
M1bot = −M1top = − 60 k.ft
V dwn H (15)(16)
M2top = 2 2 2 = 2 = 120 k.ft
M2bot = −M2top = − 120 k.ft
V dwn H (15)(16)
M3top = 3 2 3 = 2 = 120 k.ft
M3bot = −M3top = − 120 k.ft
V dwn H (7.5)(16)
M4top = 4 2 4 = 2 = 60 k.ft
M4bot = −M4top = − 60 k.ft
4. Top Girder Moments
lf t
M12 = M5top = 17.5 k.ft
rgt lf t
M12 = −M12 =− 17.5 k.ft
lf t rgt
M13 = M12 + M6top = −17.5 + 35 = 17.5 k.ft
rgt lf t
M13 = −M13 =− 17.5 k.ft
lf t rgt
M14 = M13 + M7top = −17.5 + 35 = 17.5 k.ft
rgt lf t
M14 = −M14 =− 17.5 k.ft

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
6–12 APPROXIMATE FRAME ANALYSIS

Approximate Analysis Vertical Loads APROXVER.XLS Victor E. Saouma

A B C D E F G H I J K L M N O P Q
1
2 L1 L2 L3
3 Height Span 20 30 24
4 14 Load 0.25 0.25 0.25
5 16 Load 0.5 0.5 0.5
6 MOMENTS
7 Bay 1 Bay 2 Bay 3
8 Col Beam Column Beam Column Beam Col
9 Lft Cnt Rgt Lft Cnr Rgt Lft Cnt Rgt
AAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAAA AAAAAAAA AAAAAAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAAA AAAA AAAA AAAAA AAAA
AAAAAAAAAAAA
AAAA AAAA
AAAAAAAAAAAAAAAAA A AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA AAAA
AAAAAAAA
10 AAAAAAAA
AAAAAAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAA -4.5 8.0 -4.5 AAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA AAAAAAAA -10.1 18.0 -10.1AAAA
AAAAAAAA
AAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA A -6.5
AAAAA 11.5 -6.5 AAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
A AAAAAAAAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAA
AAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAA
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
AAAAAAAA
AAAAAAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
A
A AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAA
AAAA AAAAAAAA
AAAAAAAA
AAAA
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAA
AAA AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
AAAAAAAA AAAAAAAA AAAA AAAAAAAAAAAA AA AAAA AAAAAAAA AAAAAAAA AAAAAAAAAAAA AAAAAAAA
11 -4.5 AAAA AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
-5.6 AAAAAAAA
AAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
AAA 3.6 AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
6.5
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAA
AAA AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
AAAAAAAA AAAAAAAA AAAA AAAAAAAAAAAA AA AAAA AAAAAAAA AAAAAAAA AAAAAAAAAAAA AAAAAAAA
12 4.5 AAAA AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
AAAA
AAAAAAAAAAAAAAAAAAAA
A
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
AAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAA
AA
5.6
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
AAAAAAAA
AAAA AAAAAAAA
AAAAAAAA
AAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAA
AAAAAAAA
AAA
AAAAAAA
AAA
AAAA
-3.6 AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
-6.5
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAA
AAAA AAAA
AAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAAA A AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA A AAAAAAAAAAAAAAAA
AAAAAAAA AAAAAAAA
AAAAA AAAAAAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAAAAAA
AAAAAAAA AAAAAAAAAAAAAAAAAAAAAAAA AAAA AAAA AAAAA AAAAAAAA AAAA
AAAAAAAA
AAAAAAAA
AAAAAAAAAAAA
AAAAAAAA
AAAAAAAAAAAA AAAA -20.3 36.0 -20.3AAAA AAAAAAAAAAAAAAAAAAAA AAAA AAAA AAAAA AAAAAAAA
13 AAAAAAAA
AAAAAA -9.0 16.0 -9.0 AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA A -13.0 23.0 -13.0 AAAA
AAAAA AAAAAAAAAAAA AAAA
AAAAAAAA
AAAAAAAA AAAA AAAAAAAA AAAA AAAA AAAA AAAA
AAAAAAAA
AAAA AAAAAAAA
AAAAAAAA
A
AAAAAAAA
A AAAAAAAAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAA
AAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
A AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA AAAA A AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA AAAA AAAA
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA AAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAA
AAA
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
14 -4.5 AAAA AAAAAAAA AAAAAAAA AAAA AAAAAAAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
AAAAAAAA AAAAAAAAAAAAAAAAAAAAAAAAAA
AA -5.6 AAAA AAAAAAAAAAAA AAAAAAAA AAAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
AAAA AAAAAAAAAAAA AAAAAAAA AAAAAAAA
AAA
AAA
3.6 AAAA
AAAA
AAAA
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
AAAAAAAA
AAAAAAAA AAAAAAAAAAAA AAAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAAAAAA
6.5
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAA
AAA AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
AAAAAAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA AA
AAAAAA AAAA AAAAAAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA AAAA
AAAAAAAA
15 4.5 AAAA AAAAAAAA AAAA
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
5.6 AAAA AAAAAAAAAAAA AAAAAAAA AAAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
AAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAA
AAAAAAA
AAA
-3.6 AAAAAAAA AAAA
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
-6.5
16 SHEAR
17 Bay 1 Bay 2 Bay 3
18 Col Beam Column Beam Column Beam Col
19 Lft Rgt Lft Rgt Lft Rgt
AAAAAAAAAAAAAAAAA AAAA AAAAAAAA AAAAAAAA AAAAAAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAA AAAA AAAAAAAAAAAAAAAAAAAAAAAA AAAA AAAA AAAAA AAAA AAAAAAAA AAAAAAAA AAAAAAAA
AAAAAAAAAAAAAAAAA A AAAAAAAAAAAA AAAA
AAAAAAAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAAAAAA
AAAA AAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAA AAAA
AAAAAAAAAAAA
AAAAAAAA
AAAA
AAAAAAAA
AAAAAAAAAAAA
AAAAAAAA A 2.50AAAA AAAAAAAA
AAAA
AAAA -2.50 AAAAAAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAAAAAA 3.75 AAAA AAAAAAAA
AAAAAAAA
AAAAAAAAAAAA
AAAAAAAAAAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAA
AAAAAAAA
AAAAAAAAAAAA -3.00 AAAAAAAA
AAAA
20 AAAAAAAA
AAAA
AAAAAAAAA
AAAA
AAAAAAAAAAAAA AAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA
AAAA AAAA AAAA -3.75AAAA
AAAAAAAA AAAAAAAAAAAAAAAAAAAA AAAAAAAA AAAAA 3.00 AAAA
A AAAAAAAA AAAAAAAA
AAAAAAAA
AAAA
AAAAAAAA
AAAAAAAAAAAA AAAA
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAA
AAAAAAAA AAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA A AAAAAAAAAAAA
AAAAAAAA AAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
A AAAAAAAA
AAAA AAAA
AAAA AAAA
AAAA AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAA AAAAAAAA
AAAAAAAA AAAAAAAAAAAAAAA AAAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
A AAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAA
AA AAAA AAAA AAAAAAAA AAAAAAAA AAA AAAA
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAA
AAA AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
21 -0.64 AAAA AAAAAAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA AA
AAAAAA -0.80 AAAA
AAAA AAAAAAAAAAAA AAAAAAAA AAAAAAAA AAA 0.52 AAAAAAAA
AAAAAAAA AAAAAAAA
AAAAAAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA AAAA
AAAAAAAA 0.93
AAAAAAAAAAAAAAAAAAAA
A AAAAAAAA
AAAAAAAA
AAAA
AAAA
AAAA
AAAA
AAAA
AAAA
AAAAAAAA
AAAA AAAAAAAA
AAAAAA
AA
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAA
AAAA AAAAAAAA
AAAAAAAAAAAAAAAAAAAA
AAAAAAAA AAAA
AAAAAAAA
AAAAAAA
AAA
AAAAAAAAAAAAAAAAAAAAAAAA AAAA AAAA AAAA
AAAAAAAA
AAAA
A AAAAAAAAAAAAAAAAAAAAAAAA
AAAAAAAA AAAAAAAA
AAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAAA A AAAAAAAAAAAA AAAA
AAAAAAAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAAAAAA
AAAA AAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAA AAAA
AAAAAAAAAAAA
AAAAAAAA
AAAA
AAAAAAAA
AAAAAAAAAAAA
AAAAAAAA A 5.00AAAA AAAAAAAA
AAAA
AAAA -5.00 AAAAAAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAAAAAA 7.50 AAAA AAAAAAAA
AAAAAAAA AAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAA
AAAAAAAA
AAAAAAAAAAAA -6.00 AAAAAAAA
AAAA
22 AAAAAAAA
AAAA
AAAAAAAAA
AAAA
AAAAAAAAAAAAA AAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA
AAAA AAAAAAAA AAAA -7.50AAAA
AAAA AAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAA AAAAA 6.00 AAAA
A AAAAAAAA AAAAAAAA
AAAAAAAA
AAAA
AAAAAAAA
AAAAAAAAAAAA AAAA
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA A AAAAAAAAAAAA
AAAAAAAA AAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
A AAAAAAAA
AAAA AAAA
AAAA AAAA
AAAA AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAA AAAAAAAA
AAAAAAAA AAAAAAAAAAAAAAAAAAA AAAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
A AAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAA
AA AAAA AAAAAAAAAAAAAAAA AAAAAAA AAAA
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAA
AAA AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
23 -0.56 AAAA AAAA AAAAAAAA AAAA AAAAAAAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
AAAAAAAA
AA -0.70 AAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAA
AAA 0.46 AAAAAAAA AAAAAAAA AAAAAAAAAAAA AAAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA 0.81
AAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAA
AA AAAA
AAAA AAAAAAAAAAAAAAAA AAAAAAAA AAAAAAA AAAAAAAA
AAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAA

24 AXIAL FORCE
25 Bay 1 Bay 2 Bay 3
26 Col
AAAAAAAAAAAAAAAAA
Beam Column
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
Beam AAAAAAAA
Column
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAA
A
Beam Col
AAAAAAAAAAAA
AAAAAAAAAAAAAAAAA AAAAAAAA AAAAAAAAAAAAAAAA AAAAAAAAAAAA AAAA AAAAAAAAAAAAAAAA
AAAA
AAAAAAAAAAAAAAAAA A AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAA
27 AAAAAAAA
AAAAAAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAAA
AAAA
A
AAAAAAAAAAAAAAAAAAAA
0.00 AAAAAAAA
AAAAAAAAAAAA
AAAAAAAA AAAAAAAA
AAAAAAAAAAAA
AAAAAAAAAAAA
AAAAAAAAAAAA
AAAA AAAAAAAA
AAAAAAAA
AAAA
AAAA
AAAAAAAA 0.00 AAAAAAAAAAAA
AAAAAAAA
AAAA AAAAAAAA
AAAAAAAAAAAAAAAA
AAAAAAAAAAAA
AAAAAAAAAAAA
AAAA AAAAAAAA
AAAA AAAAAAAA
AAAA AAAAA
AAAAA
A 0.00 AAAAAAAA
AAAAAAAAAAAA
AAAAAAAAAAAA
AAAA
AAAA
AAAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
A AAAAAAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
A AAAAAAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAA
AA AAAA AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA AAAA
AAAAAAAA AAAAAAAA AAAA AAAAAAAAAAAA AA AAAA AAAAAAAAAAAA AAAAAAAA AAAAAAAA AAA AAAAAAAA AAAAAAAA AAAAAAAAAAAA AAAAAAAA
28 2.50 AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAAAAAAAAAAAAAA
A
AAAA
AAAAAAAA
AAAA
AAAAAAAA
AAAA
AAAAAAAA
AAAA
AAAAAAAA
AAAA
AAAAAAAA
AAAA
AAAAAAAA
AA
AAAAAA
AA
6.25
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
AAAAAAAA
AAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
AAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAA
AAA
AAAAAAAA
AAAAAAAA
6.75
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA A
AAAA
AAAAAAAA
AAAA
AAAAAAAA
AAAA
AAAAAAAA
AAAA
AAAAAAAA
AAAA
AAAAAAAA
AAAA
AAAAAAAA
AAAA
AAAAAAAA
AAAA
3.00
AAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAAA AAAAAAAA AAAAAAAAAAAAAAAA AAAAAAAAAAAA AAAA A AAAAAAAA AAAAAAAA
AAAAAAAAAAAAAAAAA A AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAA
AAAAAAAA
AAAAAAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAA AAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAA
AAAAAAAA
AAAAAAAAAAAA
AAAA
29 AAAAAAAA
AAAAAAAA
AAAAAAAAA
AAAA
A 0.00 AAAAAAAA AAAAAAAAAAAAAAAA AAAAAAAA
AAAA
AAAAAAAA 0.00 AAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
A
A 0.00 AAAAAAAA AAAA
AAAA
AAAAAAAA
AAAA AAAAAAAA
AAAAAAAA A
AAAAAAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA AAAAAAAA
A AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
A AAAAAAAAAAAAAAAAAAAAAAAAAAAA AAAA AAAA
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAAA AAAA AAAA AAAA
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
A AAAAAAAAAAAAAAAAAAAAAAAAAAAA AAAA AAAA
AA AAAA AAAAAAAAAAAA AAAAAAAA AAAAAAAA AAA AAAA
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
30 7.50 AAAA AAAA AAAAAAAA AAAA AAAAAAAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
AA 18.75 AAAA AAAAAAAAAAAA AAAAAAAA AAAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
AAA 20.25 AAAAAAAA AAAAAAAA AAAAAAAAAAAA AAAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
9.00

Figure 6.10: Approximate Analysis for Vertical Loads; Spread-Sheet Format

Victor Saouma Mechanics and Design of Reinforced Concrete


Approximate Analysis Vertical Loads APROXVER.XLS Victor E. Saouma

A B C D E F G H I J K L M N O P Q
Draft

Victor Saouma
2 L1 L2 L3
3 Height Span 20 30 24
4 14 Load 0.25 0.25 0.25
5 16 Load 0.5 0.5 0.5
6.2 Horizontal Loads

6 MOMENTS
7 Bay 1 Bay 2 Bay 3
8 Col Beam Column Beam Column Beam Col
9 AAAAAAAA AAAAA
Lft Cnt Rgt AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAALft Cnr Rgt AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA Lft Cnt Rgt AAAA
AAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAAAA AAAA AAAA AAAA AAAA AAAA AAAA AAAA AAAA AAAA AAA
AAAAAAAAAAA
AAAA AAAA AAAAAAAA AAAA AAAA AAAAAAAA AAAA AAA
AAA
AAAAAAAA
AAAA AAAAAAAA
AAAAAAAAAAAA
AAAAAAAAAAAA
AAAAAAAA
AAAA
AAAAAAAAAAAA
AAAAAAAAAAAA AAAAAAAA
AAAA
AAAAAAAAAAAA
AAAAAAAAAAAA
AAAAAAAAAAAA AAAAAAAA
AAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAA AAAAAAAA
10 AAAAAAAAAAAA
AAAAAAAAAAAA
AAAAAAAAAAAA =-0.045*D4*D3^2 =0.08*D4*D3*D3 =+D10 AAAAAAAAAAAA
AAAAAAAAAAAA
AAAAAAAAAAAA
AAAAAAAAAAAA
AAAAAAA =-0.045*I4*I3^2 =0.08*I4*I3*I3 =+I10 =-0.045*N4*N3^2 =0.08*N4*N3*N3 =N10 AAAA
AAAAAAAAAAAA
AAAAAAAA
AAAAAAAA
AAAA
AAAA AAAAAAAAA AAAAAAAA AAAAAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA AAAAAAA
AAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAA
AAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAA
AAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAAAA AAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAAAA
AAAAAAAA AAAAAAAA AAAAA AAAAAAAA
AAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAA AAAAAAAA
AAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
A AAAA
AAAAAAAA
AAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAA
11 =+D10 AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA =-F10+I10 =-K10+N10 =-P10
AAAA
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
AAAA
AAAAAAAA
AAAA AAAAAAAAAAAA
AAAAAAAAAAAA
AAAAAAAAAAAA
AAAAAAAAAAAA
AAAAAAAAAAAA
AAAAAAAAAAAA
AAAAAAAAAAAA
AAAAAAAAAA
AAAA
AAAAAAAA
AAAAAAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAA
AAAAAAAAAAAA AAAA
AAAAAAAA
AAAAAAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAA AAAAAAAAAAAA
AAAAAAAAAAAA
AAAAAAAAAAAA
AAAAAAAAAAAA
AAAAAAAAAAAA
AAAAAAAAAAAA
AAAAAAAAAAAA
AAAAAAAAAAAA
AAAAA
12 =-C11 AAAA
AAAAAAAA
AAAAAAAA
AAAAAAAAAAAA
AAAAAAAAAAAA
AAAAAAAAAAAA
AAAAAAAAAAAA
AAAAAAAAAAAA
AAAAAAAAAAAA
AAAAAAAAAAAA
AAAAAAAAAAAA
AAAAAAAAAAAA
AAAAAAAAAAAA
AAAAAAAAAAAA
AAAAAAAAAAAA
AAAAAAAAAAAA
AAAAAAAA
AAAA
=-G11 AAAA
AAAAAAAA
AAAAAAAA
AAAAAAAAAAAA
AAAAAAAAAAAA
AAAAAAAAAAAA
AAAAAAAAAAAA
AAAAAAAAAAAA
AAAAAAAAAAAA
AAAAAAAAAAAA
AAAAAAAAAAAA
AAAAAAAAAAAA
AAAAAAAAAA =-L11
AAAAAAAAAAAA
AAAAAAAAAAAA
AAAAAA
AAAAAAAA
AAAA AAAAAAAAAAAA
AAAAAAAAAAAA
AAAAAAAAAAAA
AAAAAAAAAAAA
AAAAAAAAAAAA
AAAAAAAAAAAA
AAAAAAAAAAAA
AAAAAAAAAAAA
AAAAAAAAAAAA
AAAAAAAAAAAA
AAAAAAAAAAAA
AAAAAAAAAAAA
AAAAAAAAAAAA
AAAAAAAAAAAA
AAAAAAAAAA=-Q11
AAAAAAAAAAAA
AAAAA
AAAA AAAAAAAA
AAAAAAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAA
AAAAAAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
AAAAAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAA
AAAAAAAA AAAAAAAA AAAA
AAAAAAAA
AAAA AAAA AAAA AAAA AAAA AAAA AAAA
13 AAAA AAAAAAAA
AAAAAAAA AAAAAAAA
AAAA
AAAAAAAA
AAAA
AAAAAAAA
AAAA
AAAAAAAA
AAAA
AAAAAA
AAAA =-0.045*D5*D3^2 =0.08*D5*D3*D3 =+D13 AAAA AAAAAAAA
AAAAAAAA AAAAAAAA
AAAA
AAAAAAAA
AAAA
AAAAAAAA
AAAA
AAAAAAAA
AAAA
AAAAAAAA
AAAA
AAAAAAAA
AAAA AAAA =-0.045*I5*I3^2 =0.08*I5*I3*I3 =+I13
AAAAAAA
AAA
AAA
AAAAAAAA
AAAA
AAAAAAAA
AAAA
AAAAAAAA
AAAA
AAAAAAAA
AAAA
AAAAAAAA
AAAA
AAAAAAAA
AAAA
AAAAAAAA
AAAA
AAAAAAAA
AAAA AAAA =-0.045*N5*N3^2 =0.08*N5*N3*N3 =+N13
AAAAAAA
AAA
AAA AAAA AAAAAAAA
AAAAAAAA AAAAAAAA
AAAA
AAAAAAAA
AAAA AAAA
AAAA
AAAA AAAAAAAAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAA
AAAAAAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA AAAAAAAA
AAAAAAAA AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAA
AAAAAAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAA AAAA AAAA AAAA AAAA AAAA AAAA AAAA AAAA AAAA AAAA AAAA AAAA AAAA AAAA AAAA AAAA AAAA AAAA AAAA AAAA AAAA AAAA AAAA AAAA AAAA AAAA AAAA AAAA AAAA
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
AAAA A AAAAAAAA AAAAAAAA AAAA AAAAAAAA AAAAAAAA AAAA AAAAAAAAAAAA AAAA AAAA
AAAAAAAAAAAAAAAAAAAAAAAAAAA
14 =+D13+C12 =-F13+I13+G12 =-K13+N13+L12 AAAA =-P13+Q12
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
AAAA AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
AAAA AAAAAAAA AAAAAAAA AAAAAAAA AAAAAAAA AAAAAAAA AAAAAAAA AAAAAAAA AAAA AAAA AAAA AAAAAAAA AAAAAAAA AAAAAAAA AAAAAAAA AAAAAAAA AAAAAAAA A
AAAAAAAA
AAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAA
AAAA AAAA
AAAAAAAA
AAAAAAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAA AAAA AAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAA
AAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAA
15 =-C14 AAAA
AAAAAAAAAAAA AAAA AAAA AAAA AAAA AAAA AAAA AAAA AAAA AAAA AAAA AAAA
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
AAAA AAAA =-G14
AAAA
AAAAAAAA
AAAA
AAAAAAAAAAAA AAAA AAAA AAAA AAAA AAAA AAAA AAAA AAAA AAAA
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
AAAA AAAA
=-L14 AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA =-Q14
AAAA AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA AAAA AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
AAAAAAAA
AAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAA

16 SHEAR
17 Bay 1 Bay 2 Bay 3
18 Col Beam Column Beam Column Beam Col
19 Lft Rgt Lft Rgt Lft Rgt
AAAAAAAA
AAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAA AAAAAAAA
AAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAA AAAAAAAA
AAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA AAA
AAAAAAA AAAAAAAAAAAAAAAAAAAAAAA
AAA
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
AAA AAAAAAAA
AAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAA AAAAAAAA
AAAA AAAAAAAA AAAAAAAA
AAAAAAAA
AAAA AAAA AAAA AAAA AAAA AAAA AAAA A AAAA AAAA AAAA AAAA AAAA AAAA AAAA A AAAA AAAA AAAA AAAA AAAA AAAA AAAA AAAA AAAA AAA
AAAAAAAA
AAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAA AAAAAAAA
AAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAA
AAAA AAAA AAAA AAAA AAAA AAAA AAAA A AAAA AAAAAAAA AAAAAAAA
AAAAAAAAAAAAAAAAAAAA
AAAA
20 AAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA AAAAA =+D3*D4/2
AAAAAAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA AAAAA=-D20 AAAA
AAAAAAAA AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA=+I3*I4/2 AAAAAAAAAAAAAAAAAAAAAAA=-I20 AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA =+N3*N4/2
AAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA AAAAA =-N20 AAAA
AAAAAAAA
AAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAAAAAAA AAAA AAAAAAAA AAAAAAAA AAAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
AAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAA
AAAAAAAA
AAAAAAAA AAAAAAAA
AAAAAAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAA
AAA
AAAAAAAA AAAAAAAAA
AAAAAAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
AAAAAAA AAAAAAAA AAAAAAAA AAAAAAAA AAAA
A AAAAAAAAAAAAAAAAAAAAAAAAAAAAA
A AAAAAAAAAAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA AAAAAAAA
AAAAAAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA AAAAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
21 =2*C11/A4 AAAAAAAA
AAAA
AAAA AAAA
AAAAAAAA AAAA
AAAA AAAA
AAAA AAAA
AAAA AAAA
AAAA AAAA
AAAA AAAA
AAAA AAAA
AAAA AAAA
AAAA AAAA
AAAA AAAA
AAAA
AAAAAAAA
AAAA
AAAA AAAA
AAAAAAAA
AAAA =2*G11/A4
AAAA
AAAA
AAAAAAAA
AAAA
AAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA AAAA
AAAAAAAA AAAA
AAAA AAAA
AAAA AAAA
AAAA AAAA
AAAA
AAAAAAAA
AAAA
AAAA
AAAAAAAA
AAAAAAAA A =2*L11/A4
A
AAAA AAAAAAAA AAAAAAAA AAAA AAAAAAAA AAAA AAAA AAAA AAAA AAAA AAAA AAAA AAAA AAAAAAA
AAAA
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA=2*Q11/A4
AAAAAAAA
AAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
AAAAAAAA AAAA AAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA AAAAAAAA
AAAAAAAAAAAAAAAAAAAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
AAAAAAAA AAAA
AAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAAA AAAA AAAAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAA AAAAAAAA
AAAAAAAA AAAAAAAA
AAAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAAAA
AAAAAAAA AAAAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA AAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAA
AAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAA
AAA AAAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAA
AAAA
22 AAAA
AAAAAAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA =+D3*D5/2 AAAAAAAA
AAAAAAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA =-D22 AAAAAAAA
AAAAAAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAA =+I3*I5/2 AAAAAAAAAAAAAAAAAAAAAAA
AAA =-I22 AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA =+N3*N5/2 AAAAAAAA
AAAA AAAA AAAA AAAA AAAA AAAA AA
AAAAAAAA
AAAA
=-N22
AAAAAAAAAAAA
AAAAAAAA
AAAAAAAA
AAAA
AAAA AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAAAAAAA AAAA AAAA AAAAAAAA AAAAAAAA
AAAAAAAAAAAAAAAAAAAAAA
AAAAAAAA A AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
AAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAA
AAAAAAAA AAAAAAAA
AAAAAAAAAAAAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
AAAAAAA AAAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
A AAAA
AAAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAAAAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAAAAAA
AAAAA
23 =2*C14/A5 AAAAAAAA
AAAA AAAA AAAA AAAA AAAA AAAA AAAA AAAA AAAA AAAA AAAA AAAA AAAA
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA AAAA AAAA AAAA =2*G14/A5 AAAAAAAA
AAAA AAAA AAAA AAAA AAAA AAAA AAAA AAAA AAAA AAAA AAAA
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA AAAA AAAA A =2*L14/A5 AAAAAAAA
AAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
AAAAAAAA
AAAAAA
=2*Q14/A5
AAAAAAAA AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAA AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
24 AXIAL FORCE
25 Bay 1 Bay 2 Bay 3
26 Col Beam Column Beam Column Beam Col
AAAA AAAAAAAA
AAAAAAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAA AAAA AAAAAAAA
AAAAAAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA AAA
AAAAAAA
AAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAA
AAA AAAA AAAAAAAA
AAAAAAAA AAAAAAAA AAAA
AAAAAAAA
27 AAAA AAAA
AAAAAAAA
AAAA AAAA AAAA AAAA AAAA
AAAAAA0 AAAA AAAA AAAA AAAA AAAA AAAA AAAA AAAA AAAA 0
AAAAAAA
AAA
AAAA AAAA AAAAAAAA AAAA AAAA AAAAAAAA AAAA AAA
0
AAA AAAA AAAA AAAA AAAA
AAAAAAAA
AAAA
AAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA AAA
AAAAAAAA
AAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAA AAAAAAAA
AAAAAAAA
AAAAAAAA AAAA
AAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
AAAA AAAA AAAA AAAA AAAA AAAA AAAA AAAA AAAA AAAA AAAA AAAA AAAA AAAA AAAA AAAA AAAA AAAA AAAA AAAA AAAA AAAA AAAA AAAA AAAA AAAA AAAA AAAA AAAA AAAA AAAA A AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAAAA
28 =+D20
AAAA
=-F20+I20
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA =-K20+N20
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA =-P20
AAAAAAAAAAAAAAAAAAAAAAAAAA
AAAA
AAAAAAAA
AAAAAAAA
AAAA AAAAAAAA
AAAA AAAAAAAA
AAAA AAAAAAAA
AAAA AAAAAAAA
AAAA AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
AAAA AAAAAAAA
AAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA AAAAAAA AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
AAAAAAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA AAA
AAAAAAA AAAAAAAA
AAAA
AAAAAAAA AAAAAAAA
AAAAAAAA
29 AAAAAAAAAAAAAAAAAAAAAAAAAA
AAAAAAAA 0 AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA AAA
0 AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA 0 AAAAAAAAAAAAAAAA
AAAA
AAAA
AAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA AAAAA
AAAAAAAA AAAAAAAA
AAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA AAA
AAAAAAA AAAA AAAAAAAA
AAAAAAAAAAAA
AAAAAAAAAAAA AAAAAAA
AAAAAAAAAAAA AAAAAAAA
AAAA AAAAAAAA
AAAAAAAA AAAA
AAAAAAAA
AAAAAAAA AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA AAAAAAAA
AAAAAAAA AAAAAAAA AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA AAAAAAAAA
AAAAAAAA AAAAAAAA
AAAAAAAAAAAA
AAAAAAAAAAAA
AAAAAAAAAAAA
AAAAAAAAAAA
A
AAAAAAAAAAAAAAAA
AAAAAAA AAAAAAAA
AAAAAAAAAAAA
AAAAAAAAAAAA
AAAA AAAA
AAAAAAAAAAAAAAAA
AAAAAAAA
AAAAAAAAAAAAAAAA
AAAAAAAAAAAA
AAAA AAAA AAAA
AAAAAAAAAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAA
30 =+C28+D22 AAAA AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
AAAAAAAA =+G28-F22+I22 AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA =+L28-K22+N22 AAAAAAAAAAAAAAAAAAAAA =+Q28-P22
AAAA AAAA AAAA AAAA AAAA AAAA AAAA AAAA AAAA AAAA AAAA AAAA AAAA AAAA AAAA AAAA
AAAAAAAA AAAA AAAA AAAA AAAA AAAA AAAA AAAA AAAA AAAA AAAA AAAA AAAA A
AAAAAAAAAAAAAAAAAAAAAAAAAAAA
AAAA AAAAAAAA AAAAAAAA AAAA
AAAAAAAAAAAAAAAAAAAAAAAAAAAA
AAAA AAAAAAAA AAAA AAAA AAAA AAAA AAAA AAAA A
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA

Figure 6.11: Approximate Analysis for Vertical Loads; Equations in Spread-Sheet

Mechanics and Design of Reinforced Concrete


6–13
Draft
6–14

5. Bottom Girder Moments


APPROXIMATE FRAME ANALYSIS

M9lf t = M1top − M5bot = 60 − (−17.5) = 77.5 k.ft


M9rgt = −M9lf t =− 77.5 k.ft
lf t
M10 = M9rgt + M2top − M6bot = −77.5 + 120 − (−35) = 77.5 k.ft
rgt lf t
M10 = −M10 =− 77.5 k.ft
lf t
M11 = M10 + M3top − M7bot = −77.5 + 120 − (−35)
rgt
= 77.5 k.ft
rgt lf t
M11 = −M11 =− 77.5 k.ft

15K 14
5 12 6 13 7 8
14’

30K 9 10 11
1 2 3 4 16’

20’ 30’ 24’

+17.5’K +35’K +35’K +17.5’K

K
-17.5’K -35’K -35’K -17.5’K
+60’ +120’K +120’K +60’K

-60’K -120’K -120’K -60’K

+17.5’K +17.5’K +17.5’K


-17.5K -17.5K -17.5K
K K K
+77.5’ +77.5’ +77.5’

-77.5’K -77.5’K -77.5’K

Figure 6.12: Approximate Analysis of a Building; Moments Due to Lateral Loads

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
6.2 Horizontal Loads

6. Top Girder Shear


6–15

2M lf t
lf t
V12 = − L1212
= − (2)(17.5)
20 = −1.75 k
rgt lf t
V12 = +V12 = −1.75 k
2M lf t
lf t
V13 = − L1313
= − (2)(17.5)
30 = −1.17 k
rgt lf t
V13 = +V13 = −1.17 k
2M lf t
lf t
V14 = − L14
14
= − (2)(17.5)
24 = −1.46 k
rgt lf t
V14 = +V14 = −1.46 k

7. Bottom Girder Shear


2M lf t
V9lf t = − L12
9
= − (2)(77.5)
20 = −7.75 k
V9rgt = +V9lf t = −7.75 k
2M lf t
lf t
V10 = − L1010
= − (2)(77.5)
30 = −5.17 k
rgt lf t
V10 = +V10 = −5.17 k
2M lf t
lf t
V11 = − L1111
= − (2)(77.5)
24 = −6.46 k
rgt lf t
V11 = +V11 = −6.46 k

8. Top Column Axial Forces (+ve tension, -ve compression)


lf t
P5 = −V12 = −(−1.75) k
rgt lf t
P6 = +V12 − V13 = −1.75 − (−1.17) = −0.58 k
rgt lf t
P7 = +V13 − V14 = −1.17 − (−1.46) = 0.29 k
rgt
P8 = V14 = −1.46 k

9. Bottom Column Axial Forces (+ve tension, -ve compression)

P1 = P5 + V9lf t = 1.75 − (−7.75) = 9.5 k


rgt
P2 = P6 + V10 + V9lf t = −0.58 − 7.75 − (−5.17) = −3.16 k
rgt lf t
P3 = P7 + V11 + V10 = 0.29 − 5.17 − (−6.46) = 1.58 k
rgt
P4 = P8 + V11 = −1.46 − 6.46 = −7.66 k

Design Parameters On the basis of the two approximate analyses, vertical and lateral load,
we now seek the design parameters for the frame, Table 6.2.

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
6–16 APPROXIMATE FRAME ANALYSIS

Portal Method PORTAL.XLS Victor E. Saouma

A B C D E F G H I J K L M N O P Q R S
1 PORTAL METHOD
2 # of Bays 3 L1 L2 L3
3 20 30 24
4 MOMENTS
5 # of Storeys 2 Bay 1 Bay 2 Bay 3
6 Force Shear Col Beam Column Beam Column Beam Col
7 H Lat. Tot Ext Int AAAAAAAAAAAAAAAAA
Lft Rgt AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA Lft Rgt AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA Lft Rgt AAAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAAA A AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAA A
AAAAAAAA
AAAAAAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAA AAAAAAAA
AAAAAAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAA AAAAAAAA
AAAAAAAAAAAA
AAAAAAAA
8 AAAAAAAA
AAAAAAAA
AAAA
AAAA
AAAAAAAA
AAAAA
AAAA
AAAAAAAA A 17.5 -17.5 AAAA
A
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAA
AAAAAAAA
AAAA
AAAAAAAA
AAAA
AAAAAAAA
AAAA
AAAAAAAA
AAAA
AAAAAAAA
AAA
AAAAAAA
AAAAAAA
17.5 -17.5 AAAAAAAA
AAAAAAAA
AAAA
AAAAAAAA
AAAA
AAAAAAAA
AAAA
AAAAAAAA
AAAA
AAAAAAAA
AAAA
AAAAAAAA
AAAA
AAAAAAAA
AAAA
AAAAAAAA
AAAAAAAA
17.5 -17.5AAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAA
AAAA
AAAAAAAA
A
A
AAAAAAAAAAAAAAAAAAAAAAAA
A AAAAAAAAAAAAAAAA AAAA AAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA AAAA
AAAAAAAA
AAAA AAAA
AAAAAAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAA
AAAA AAAAA
AAAA AAAA AAAA
AAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAA AAAAAAAAAAAAAAAAAAAAAAAA
9 H1 14 15 15 2.5 5 17.5 AAAA AAAAAAAA AAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAAAAAA
35.0 AAAA
AAAAAAAA
AAAAAAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAA 35.0 AAAAAAAA AAAAAAAA AAAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAA 17.5
AAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAA
AAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAA AAAAAAAAAAAAAAAAAAAAAAAA
AAAA
AAAAAAAA AAAAAAAAAAAAAAAA AAAA AAAAAAAA AAAAAAAA AAAAAAAA
10 -17.5 AAAA AAAAAAAAAAAAAAAAAAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAAAAAA -35.0 AAAAAAAAAAAAAAAAAAAAAAAA
AAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
-35.0 AAAAAAAAAAAAAAAAAAAAAAAA
AAAAAAAA AAAAAAAAAAAAAAAA -17.5
AAAAAAAAAAAAAAAAAAAA
A AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAA
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAAA
AAAA AAAAAAAAAAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAAA AAA AAAA AAAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAAA A AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAA A
11 AAAAAAAA
AAAAAAAAAAAA
AAAAAAAA AAAAAAAA
AAAAAAAAA
AAAA
A 77.5 -77.5 AAAA AAAAAAAA
AAAA
AAAAAAAA
AAAA AAAAAAAA
AAAAAAAAAAAA
AAAAAAAAAAAA
AAAA AAAAAAAA
AAAAAAAAAAAA
AAAA AAAA
AAA 77.5 -77.5 AAAAAAAA
AAA
AAAAAAA AAAAAAAAAAAA
AAAAAAAA AAAAAAAA
AAAAAAAAAAAA
AAAA AAAAAAAA
AAAAAAAAAAAA
AAAA AAAAAAAA
AAAAAAAA
AAAA 77.5 -77.5AAAAAAAA
AAAA
AAAAAAAA AAAAAAAAAAAA
AAAAAAAA AAAAAAAA
AAAAAAAAA
AAAA
A
AAAAAAAAAAAAAAAAAAAA
A AAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAA AAAAAAAAAAAAAAAAAAAAAAAA
12 H2 16 30 45 7.5 15 60.0 AAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAA
AAAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAAAAAA
120.0 AAAA
AAAAAAAA
AAAAAAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAA 120.0 AAAAAAAA
AAAAAAAAAAAA
AAAAAAAA
AAAAAAAA
AAAA
AAAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAA 60.0
AAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAA AAAAAAAAAAAAAAAAAAAA
AAAA AAAA AAAAAAAAAAAAAAAAAAAAAAAA
AAAA
AAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA AAAAAAAAAAAAAAAAAAAAAAAA
13 -60.0 AAAA AAAAAAAA
AAAAAAAA
AAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAA
AAAAAAAA
AAAAAAAA
AAAA
-120.0 AAAA
AAAAAAAA
AAAAAAAAAAAA
AAAAAAAA
AAAAAAAA
AAAA
AAAAAAAAAAAAAAAAAAAAAAAA
AAAAAAAA
AAAA
-120.0 AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAA
AAAAAAAA
AAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAA
AAAAAAAA
AAAAAAAA
AAAA
-60.0
14 SHEAR
15 Bay 1 Bay 2 Bay 3
16 Col Beam Column Beam Column Beam Col
17 Lft Rgt Lft Rgt Lft Rgt
AAAAAAAAAAAAAAAAA AAAAAAAA AAAAAAAAAAAA AAAAAAAA AAAAAAA AAAAAAAA AAAAAAAA AAAAAAAA AAAAAAAA AAAA AAAAAAAA AAAAAAAAA
AAAAAAAAAAAAAAAAA A AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA AAAA
AAAAAAAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAAAAAA
AAAA AAAA
AAAAAAAAAAAA
AAAAAAAAAA
AAAAAAAA
AAAAAAAAAAAA
AAAAAAAA A -1.75 -1.75 AAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAA
18 AAAAA AAA -1.17 -1.17 AAAAAAAA
AAAAAAA AAAAAAAA
AAAAAAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA AAAA -1.46 -1.46AAAAAAAA
AAAAAAAA AAAAAAAA
AAAAAAAA AAAAAA
AAAAAAAA
AAAA AAAAAAAA
AAAAAAAA
AAAAAAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA AAAAAAAA
AAAAAAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA AAAAAAAA
AAAAAAAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAA
A AAAAAAAAAAAAAAAA AAAA AAAAAAA
AAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAA AAAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAA AAAA AAAAA
AAAA AAAA AAAAAAAAAAAAAAAAAAAAAAAA
AAAAAAAA AAAAAAAAAAAAAAAA AAAAAAAA AAAAAAAA AAAAAAAA AAAAAAAA AAAAAAAA AAAAAAAA
19 2.50 AAAA AAAAAAAAAAAAAAAAAAAAAAAA
AAAA
AAAAAAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAAAAAA
AAAAAAAA 5.00 AAAAAAAA
AAAAAAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAA
AAAAAAAAAAAAAAAAAAAAAAAA 5.00 AAAAAAAAAAAAAAAAAAAAAAAA
AAAAAAAA AAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAAAAAA
AAAAAAAA 2.50
AAAAAAAAAAAAAAAAAAAAAAAA
AAAAAAAAAAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAA AAAA
AAAAAAAAAAAAAAAAAAAAAAAA
AAAAAAAAAAAA
AAAA AAAA AAAA
AAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAA
AAAAAAAAAAAA
AAAAAAAAAAAA
AAAA AAAAAAAAAAAAAAAAAAAAAAAA
20 2.50 AAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAA
AAAAAAAA 5.00 AAAA
AAAAAAAAAAAA
AAAAAAAAAAAA
AAAAAAAA 5.00 AAAAAAAA
AAAAAAAAAAAA
AAAAAAAA
AAAAAAAA
AAAA
AAAAAAAA 2.50
AAAAAAAAAAAAAAAAAAAA
AAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA AAAAAAAAAAAAAAAAAAAAAAAA
AAAA
A AAAA
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
AAAA
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAAA A AAA AAAA
AAAAAAAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAAAAAA
AAAA AAAA
AAAAAAAAAAAA
AAAAAAAAAA
AAAAAAAA
AAAAAAAAAAAA
AAAAAAAA A -7.75 -7.75 AAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAA
21 AAAAA AAA -5.17 -5.17 AAAAAAAA
AAAAAAA AAAAAAAA
AAAAAAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA AAAA -6.46 -6.46AAAAAAAA
AAAAAAAA AAAAAAAA
AAAAAAAA AAAAAA
AAAAAAAA AAAAAAAA AAAAAAAA AAAAAAAAAAAA AAAAAAAA AAAA AAAAAAAA AAAA AAAAAAAA AAAAAAAA AAAAAAAA AAAA
AAAAAAAA
AAAA AAAAAAAA
AAAAAAAA A
AAAAAAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA AAAAAAAA
AAAAAAAA
AAAAAAAA A
AAAAAAAAAAAAAAAAAAAAAAAA
A AAAAAAAAAAAAAAAA AAAA AAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA AAAA
AAAAAAAA
AAAA AAAA
AAAAAAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAA
AAAA AAAAA
AAAA AAAA AAAA
AAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAA AAAAAAAAAAAAAAAAAAAAAAAA
22 7.50 AAAA AAAAAAAA AAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAAAAAA
15.00 AAAA
AAAAAAAAAAAAAAAAAAAAAAAA
AAAAAAAA AAAAAAAA AAAAAAAA
15.00 AAAAAAAA AAAAAAAA AAAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAA
7.50
AAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAAA
AAAAAAAA AAAA
AAAAAAAAAAAAAAAA AAAAAAAA AAAAAAAAAAAAAAAA AAAAAAAA AAAA
AAAAAAAAAAAAAAAA
23 7.50 AAAA AAAAAAAA AAAAAAAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAA
15.00 AAAAAAAA
AAAAAAAA
AAAA
AAAAAAAA AAAAAAAA
AAAAAAAAAAAAAAAAAAAA
AAAAAAAAAAAA AAAAAAAA
AAAAAAAAAAAAAAAA
AAAA
15.00 AAAAAAAA
AAAAAAAA
AAAAAAAA AAAA
AAAAAAAAAAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAA
7.50
24 AXIAL FORCE
25 Bay 1 Bay 2 Bay 3
26 Col Beam Column Beam Column Beam Col
AAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAAA A AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAA A
AAAAAAAA
AAAAAAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAA AAAAAAAA
AAAAAAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAA AAAAAAAA
27 AAAAAA 0.00 AAA
AAAAAAA 0.00 AAAA
AAAAAAAA 0.00 AAAAAAAAAAAA
AAAAAAAA
AAAAAA
AAAAAAAA AAAAAAAA
AAAAA AAAAAAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAA AAAAAAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA AAAAAAAA AAAAAAAA
AAAAA
AAAAAAAA AAAA
AAAAAAAAAAAAAAAAAAAA
A AAAAAAAAAAAAAAAAAAAA AAAAAAAA AAAA
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAA AAAA AAAAAAAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAA
AAAAAAAA AAAA
AAAAAAAA AAAA
AAAAAAAA AAAA
AAAAAAAA AAAA
AAAAAAAA
AAAA
AAAAAAAAAAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAA
28 1.75 AAAAAAAA
AAAAAAAA
AAAAAAAAAAAAAAAAAAAA
A
AAAAAAAAAAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAA
-0.58
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
AAAA
AAAAAAAA
AAAAAAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAA 0.29
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
AAAAAAAA
AAAAAAAA
AAAA
AAAAAAAAAAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAA
-1.46
AAAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAAA AAAAAAAA AAAAAAAAAAAA AAAAAAAA AAAAAAA AAAAAAAA AAAAAAAA AAAAAAAA AAAAAAAA AAAA AAAAAAAA AAAAAAAA A
AAAAAAAAAAAAAAAAA A AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAA A
AAAAAAAA
AAAAAAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAA AAAAAAAA
AAAAAAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAA AAAAAAAA
29 AAAAAA 0.00 AAA
AAAAAAA 0.00 AAAA
AAAAAAAA 0.00 AAAAAAAAAAAA
AAAAAAAA
AAAAAA
AAAAAAAA AAAAAAAA
AAAAA AAAAAAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAA AAAAAAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA AAAAAAAA AAAAAAAA
AAAAA
AAAAAAAAAAAA
AAAAAAAAAAAAAAAAAAAA
A AAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAA
AAAAAAAA AAAA
AAAAAAAA AAAA
AAAAAAAA AAAA
AAAAAAAA AAAA
AAAAAAAA
AAAA
AAAAAAAAAAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAA
30 9.50 AAAA AAAA
AAAA
AAAAAAAA
AAAA
AAAAAAAA
AAAA
AAAAAAAA
AAAA
AAAAAAAA
AAAA
AAAAAAAA
AAAA
-3.17 AAAA
AAAAAAAA
AAAAAAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAA 1.58 AAAAAAAA
AAAAAAAA
AAAA
AAAA
AAAAAAAA
AAAA
AAAAAAAA
AAAA
AAAAAAAA
AAAA
AAAAAAAA
AAAA
-7.92

Figure 6.13: Portal Method; Spread-Sheet Format

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
6.2 Horizontal Loads
Portal Method

A
A
A
B
A
A
C
A
A
D
A
A
E
A
A
F
A
A
G
A
A
H
A
A
I
PORTAL.XLS

A
A
J
A
A
K
A
A
L
AA
AA
M
A
A
N
A
A
O
A
A
P
A
A
Q
6–17

A
A
R
A
A
Victor E. Saouma

S
1 PORTAL METHOD A
A A
A A
A A
A A
A A
A A
A A
A A
A A
A A
A AA
AA A
A A
A A
A A
A A
A A
A
A A A A A A A A A A A AA A A A A A A
A A
AAAAAAAAAAAAAA A
AAAAAAAAAAAAAAAAAAAAA A
A AAAAAAAAAAAAAAAA
A3 A AL1 A A AAAAAAAA A A
A AAAAAAAAAAAAAAAAAAAAAAA
AA AA A A A A
2 AAAA
# ofAAAA
Bays
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAA
AAAAAA
AAAAAAAAA
AAAAAAAAAAAAAAAAAAAAA
A AAAAAAAAAAAAAAAA AAAAAAAA
AAAAA AAAAAAAA
AAAAAAAA
AAAAAAA
AAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAAAAAA
A AAAA AAAAAAAA
AAAA
A AAAAAAAA
A AAAAAAAAAAAAAAAAAAAAAAA L2 AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
AAAA
AA L3 AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
AAAAAAAA AAAA A A A A A A A AAAA
AA AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAA AAAAAAAAAAAAAAAAAA
A AAAAAAAAAAAAA
3 A
A A
A A
A A
A A
A A20
A A
A A
A AA30
AA A
A A
A A 24
A A
A
A
A A
A A
A A
A A
A A
A A
A A
A A
A A
A A
A AA
AA A
A A
A A
A A
A A
A A
A
4 A
A A
A A
A A
A A
A A
A A
A MOMENTS A
A A
A A
A A
A AA
AA A
A A
A A
A A
A A
A A
A
A
A A
A A
A A
A A
A
AAAAAAAAAAA A
A A
A A
A AA
AA A
A A
A A A A
5 # of Storeys A A A A A2 Bay 1 A A A Bay 2 AA A A Bay 3 AA A
A
A
A
A A A A A AAAAAAAAAAA A A A AA A A A A A
A A A A A
6 Force AA Shear A
A Col Beam A
A Column Beam A
A Column Beam A
A Col
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
A AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
A AAAAAAAAAAAAAAAAAAAA
A AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
A AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
A AAAAAAAAAAAAAA
7 H Lat. AAA Tot Ext AInt
A
A AAAAAAAAAAA AAAAAAAAAAAAAAAAAAAA
Lft A Rgt
A
A AAAA AAAA AAAAAAAAAAAA AAAAAAA
Lft A Rgt
A
A AAAAAAAAAAAAAAAAAAAAAAAAAAA
Lft A Rgt
A
A AAAAAAAAAAAAAA
A
A A
A
AAAAAAAAAAAAAAAAAAAA
AAAAAAAA AAAAAAAA AAAA=+H9 AAAAAAAA
AAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAA
AAA AAAAAAAAAAAAAAAAAAAAAAAAAAA
AAAAAAAA AAAAAAAAAAAA AAAAAAA =+N8+O9
AAAAAAAAAAAAAA
AAAAAAAA AAAAAA
8 A A AAAAAAAA =-I8 =+J8+K9 =-M8 =-Q8
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
A AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
A AAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAA
AAAAAAAAAAAAAAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAA
AAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAA AAAAAAAA
AAAAAAAA
AAAAAA
AAAAAAAAAAAAAAAAAAAA
AAAA AAAAAAAA
AAAAAAAAAAAA
AAAAAAAAAAAA AAAA
AAAAAA AAA
AAAAAAAAAAAAAAAAAAAAAAAA AAAA
AAAAAAAAAAAAAAAAAAAAAAAAAAA
AA
A
AAAAA A
A=2*E9
AAAA
AAAAAAAAAAAAAAAA=+F9*B9/2
AAAAAAAA AAAA
AAAAAAAAAAAA
AAAAAAAAAAAA
AAAAAAAAAA
AA =+K9
AAA
AAAAAAAAAAAAAAAAAAAAAAA=+H9
AAAAAAAA
H1
9 AAAA 14 AAAA15 =+C9 =+D9/(2*$F$2) AAAAAAAAAAAAAAAAA =+E9*B9/2
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAA
AAAAAAAAAAAAA A AAAAAAAAAAAAAAA
AAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
A AAAA
AAAAAAAAAAAAAAAAAAAA
AAAAAAAA AAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAA
AAAA
AAAAAAAAAAAAAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAA AAAA
A AAAAAAAAAAAAAAAAA AAAA AA AAA
10 A A =-H9 AAAAAAAA AAAAAAAAAAAA=-K9 AAAA AAAA AAAAAAAA AAAA AAAAAA =+K10 AAAAAAAA AAAAAAAAAAAAAAAAAAA=+H10
A A AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAA
AA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAA
A
A A
A
AAAAAAAAAAA AAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAAAAAA
AAAA
AAAA
AAAA
AAAAAAAA
AAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA AAAA
AAAAAAA
AAA AAAAAAAAAAAAAAAAAAAAAAAA AAAA
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
AAA
AAAAAAAAAAAA
AAAAAAAAAAAAAA
AA
11 A
A A
A
AAAAAAAAAAAAAAAAAAAA=+H12-H10 =-I11 AAAAAAAAAAAAAAAAAAAAAAAAAAA=+K12-K10+J11 =-M11 AAAAAAAAAAAAAAAAAAAAAAAAAAA =+O12-O10+N11 =-Q11 AAAAAAAAAAAAAA
AAAA AAAAAAAAAAAAAAAA AAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAA AAAAAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
A AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
A AAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAA AAA
AAAAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAA
A
A A
A
AAAAAAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAAAAAA=+F12*B12/2 AAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAA
AA
AAAAAAAAAAAAAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAAAAA=+H12
H2 16 30 A =SUM($C$9:C12) A=+D12/(2*$F$2)
12 AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA A=2*E12
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA =+E12*B12/2 AAAAAAAAAAAAAAAA AA =+K12
AAAAAAAAAAAAAAAAAAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAA AAAAAAAAAAAAAAAAAAAAAAAA
A A AAAA AAAA AAAAAAAAAAAAAAAAAAAAAAAAAAA AAA
13 A
A A
A =-H12 AAAAAAAAAAAAAAAAAAAA=-K12
AAAA AAAAAAAAAAAA AAAA AAAAAAAA
AAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAA
AA =+K13 AAAAAAAAAAAAAAAAAAAAAAAAAAA=+H13
AAAA AAAAAAAA AAAAAAAA AAAAAAA
A
A A
A A
A A
A A
A AAAAAAAAAAAA
A
A
A
AAAAAAAAAAAAA
A
A
AAAAAAAA
A
A
A
A
A
AAAAAAAAAAAAAAAAAAAA
AA
AA
A AAAAAA
A
A
A
A
A
AAAAAAAAAAAAAAAAAAAA
A
A
A AAAAAAA
A
A
A
14 A A A A A A A
A SHEAR A
A A
A A
A A
A AA
AA A
A A
A A
A A
A A
A A
A
A
A A
A A
A A
A A
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
A A
A A A A A A AA A A A A A A
A A A A A A A A A AA A
A A A A A
15 AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA A Bay 1 A
A A
A A
A
Bay 2 AA
AA A
A
Bay 3
A
A A
A A
A A
A A
A A
A
16 A
A A
A A
A A
A A
A A
A Col Beam Column Beam Column Beam Col
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
A A A A A A A
A A A A A A A
A
17 A A A A A A Lft Rgt Lft Rgt A Lft Rgt
A A A A A
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA A AAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAAAAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAA
AAA
A A A A A A AAAAAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAA
A A A A A A AAAA=-2*I8/I$3 =+I18 AAAA =+M18AAAA AAAAAAAA AAAAAAAA AAAAAAA =+Q18AAAA AAAAAAAA AA
18 A A A A A
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA A AAAAAAAA
AAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAA
AAAAAAAAAAAAAAAAAAAA AAAAAAAA
AAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAA
AAA=-2*M8/M$3 AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAA
=-2*Q8/Q$3 AAAAAAAA
AAAAAAAA
AAAAAA
A A A A A A AAAAAAAAAAAAAAAAAAAA AAAA AAAA AAAAAAAA AAAA AAAA AAAA
AA AAA
AAAAAAAAAAAAAAAAAAAAAAAAAAA AAAA AA
A A A A A A AAAAAAAA AAAAAAAA
AAAAAAAAAAAA
AAAAAAAAAAAA
AAAAAA AAAAAAAAAAAAAAAAAAAAAAAAAAA
AAAAAAAA
AAAAAAAA
AAAA AAAA
AAAAAAAAAAAA
AAAAAAAAAAAA
AAAAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
19 A A A A A A =+E9 AAA
A A A A A A AAAAAAAA AAAAAAAA=+F9 AA =+F9 AAAAAAAA AAAAAAA =+E9
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
A A A A A A AAAA AAAAAAAAAAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAA
AA AAAA AAAAAAAAAAAAAAAAAAA
A A A A A A AAAA AAAAAAAAAAAA AAAA AAAA AAAA AAAAAAAA AAAAAAAA AAAAAAA
20 A A A A A A =+H19 AAAAAAAAAAAAAAAAAAAA=+K19 AAAAAAAAAAAAAAAAAAAAAAAAAA =+O19 AAAAAAAAAAAAAAAAAAAAAAAAAAA=+S19
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
A A A A A A AAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAA AAAA AAAA AAAAAAAAAAAA AAAA AAAAAAAAAAAAAAAAAAAAAAAAAA
AAA AAAAAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAA
A A A A A A AAAAAAAAAAAAAAAAAAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAA
AAA AAAAAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAA
21 A A A A A A AAAAAAAA AAAAAAAA AAAA=-2*I11/I$3 =+I21 AAAA
AAAAAAAA =-2*M11/M$3 =+M21AAAA AAAAAAAA AAAAAAAA
AAAAAAAA
AAAAAAAA AAA =-2*Q11/Q$3
AAAAAAA =+Q21AAAAAAAA
AAAAAAAA AA
AAAAAA
A A A A A
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA A AAAA AAAAAAAA
AAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAA AAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAA
AAAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAA AAAA
AAAAAAAAAAAAAAAAAAAA
AAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA AAAAAAAAAAAAAAAAAAAAAAAAAAA
AAAAAA
AA AAAAAAAAAAAAAAAAAAAAAAAAAAA
A A A A A A AAAAAAAAAAAAAA
A A A A A A AAAA AAAA AAA
22 A A A A A A =+E12 AAAAAAAAAAAAAAAAAAAA=+F12 AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAA
AA =+F12 AAAAAAAAAAAAAAAAAAAAAAAAAAA =+E12
A A A A A
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA A AAAA AAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAA AAAA AAAA AAAAAAAAAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAAAAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAA
AA AAAAAAAAAAAAAAAAAAAAAAAA
A
A A
A A
A A
A A
A A
A AAAA=+K22 AAAA AAAAAAAAAAAAAAAAAAAAAAAAAAA AAA=+S22
23 A A A A A
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA A =+H22 AAAA AAAAAAAAAAAA AAAA AAAA AAAA AAAAAAAA AAAA AAAAAA =+O22 AAAA AAAAAAAA AAAAAAAA AAAAAAA
A A A A A A A AAAAAAAAAAAAA
A AAAAAAAAA A AAAAAAAAAAAAAAAAAAAA
AA A AAAAAA A A AAAAAAAAAAAAAAAAAAAA
A A AAAAAAA A
A A A A A A A
A AXIAL FORCE A
A A
A A
A A
A AA
AA A
A A
A A
A A
A A
A A
A
24 A
A A
A A
A A
A A
A A
A A A A A A AA A A A A A A
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
A A A A A A A A A A A AA A A A A A A
A A A A A A A
A A
A A
A AA A
25 A
A
A
A
A
A
A
A
A
A
A
A Bay 1 A A A Bay 2 AA
AA
A
A Bay 3
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
A A A A A A
26 A
A A
A A
A A
A A
A A
A Col Beam Column Beam Column Beam Col
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
A A A A A A AAAAAAAAAAAAAAAAAAAA AAAA AAAA AAAAAAAAAAAA AAAAAAA AAAAAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAA
A A A A A A AAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAA
27 A
A A
A A
A A
A A
A A
A
AAAA AAAAAAAAAAAA AAAA
AAAAAAAAAAAAAAAAAAAA0 AAAA AAAA AAAAAAAAAAAA AAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAAAAA0
AAAAAAAA AAAAAAAAAAAA AAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAAAAA 0
AAAAAAAA AAAAAA
AAAAAAAAAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
A A A A A A AAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAAAAAA AAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAA
AAAAAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAA
28 AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
A
A
A AAAA AAAA AAAA
A
A
AAAA
A AAAA
A
A
AAAA
A AAAAAAAA =-I18
AAAA
AAA AAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAAAAAA
AAAAAAAA
AAAA AAAAAAAAAAAA
AAAA
AAAA=+J18-M18
AAAAAAAA
AAAA AAAA AAAAAAAAAAAA AAAA
AAAA
AAAA
AAA
AAAA
AAAA AAAA
AAAAAAAA
AAAA AAAA
AAAA AAAA
AAAA
AA
AA =+N18-Q18
AAAA
AA AAAA AAAAAAAAAAAA AAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAAAAA
AAAAAAAA
AAAA AAAAAAAAAAAA
AAAA AAAAAAAA
AAAAAAAA AAA=+R18
AAAAAAAAAAA
AAAAAAAAAAAAAA
AAAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAAAAAA AAAAAA AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA AAAAAAAAAAAAAAAAAAAAAAAAAA
AAAAAAA
AAA AAAAAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAAAAAA AA
A
A A A
A A
A A
A A
A
AAAA AAAA
AAAAAAAA
AAAAAAAA AAAA AAAA AAAAAAAA AAAAAAAAAAAA AAAAAAA AAAAAAAA AAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAA
AAA0 AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAA AAAAAAAA
AAAAAAAA
AAAAAA
29 0 0
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
A A A A A A AAAA AAAA
AAAAAAAAAAAAAAAAAAAA AAAA AAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAA
AAAA AAA
AAAAAAAAAAAAAAAAAAAAAAAAAAA AAAA AA
A
A A
A A
A A
A A
A A
A
AAAAAAAAAAAAAAAAAAAA
AAAAAAAA AAAAAAAAAAAA AAAA AAAA AAAAAAAA AAAA AAAAAA
AA
AAAAAAAAAAAAAAAAAAAAAAAAAAA
AAAAAAAA AAAAAAAAAAAAAAAAAAA
30 A A A A A A =+H28-I21 AAAA AAAAAAAAAAAAAAAA=+K28+J21-M21 AAAA =+O28+N21-Q21 AAAAAAAAAAAAAAAAAAAAAAA=+S28+R21
A A A A A A AAAAAAAAAAAAAAAAAAAA AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAA
AA AAAA
AAAAAAAAAAAAAAAAAAAAAAAAAAA

Figure 6.14: Portal Method; Equations in Spread-Sheet

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
6–18 APPROXIMATE FRAME ANALYSIS

Mem. Vert. Hor. Design


Values
Moment 4.50 60.00 64.50
1 Axial 7.50 9.50 17.00
Shear 0.56 7.50 8.06
Moment 5.60 120.00 125.60
2 Axial 18.75 15.83 34.58
Shear 0.70 15.00 15.70
Moment 3.60 120.00 123.60
3 Axial 20.25 14.25 34.50
Shear 0.45 15.00 15.45
Moment 6.50 60.00 66.50
4 Axial 9.00 7.92 16.92
Shear 0.81 7.50 8.31
Moment 4.50 17.50 22.00
5 Axial 2.50 1.75 4.25
Shear 0.64 2.50 3.14
Moment 5.60 35.00 40.60
6 Axial 6.25 2.92 9.17
Shear 0.80 5.00 5.80
Moment 3.60 35.00 38.60
7 Axial 6.75 2.63 9.38
Shear 0.51 5.00 5.51
Moment 6.50 17.50 24.00
8 Axial 3.00 1.46 4.46
Shear 0.93 2.50 3.43

Table 6.1: Columns Combined Approximate Vertical and Horizontal Loads

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
6.2 Horizontal Loads 6–19

Mem. Vert. Hor. Design


Values
-ve Moment 9.00 77.50 86.50
9 +ve Moment 16.00 0.00 16.00
Shear 5.00 7.75 12.75
-ve Moment 20.20 77.50 97.70
10 +ve Moment 36.00 0.00 36.00
Shear 7.50 5.17 12.67
-ve Moment 13.0 77.50 90.50
11 +ve Moment 23.00 0.00 23.00
Shear 6.00 6.46 12.46
-ve Moment 4.50 17.50 22.00
12 +ve Moment 8.00 0.00 8.00
Shear 2.50 1.75 4.25
-ve Moment 10.10 17.50 27.60
13 +ve Moment 18.00 0.00 18.00
Shear 3.75 1.17 4.92
-ve Moment 6.50 17.50 24.00
14 +ve Moment 11.50 0.00 11.50
Shear 3.00 1.46 4.46

Table 6.2: Girders Combined Approximate Vertical and Horizontal Loads

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
6–20 APPROXIMATE FRAME ANALYSIS

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft

Chapter 7

ONE WAY SLABS

7.1 Types of Slabs

1 Types of slabs, Fig. 7.1

Beam
Beam

Beam
Beam

Beam

Beam

one−way slab two−way slab Grid slab

Flat slab
one−way slab Flat plate slab

Figure 7.1: Types of Slabs

2 Two types of slabs, Fig. 7.2


1. One way slab: long span/short span > 2. Load is transmitted along the short span.

2. Two Way slab: Long span/short span <2. Load is transmitted along two orthogonal
directions.

L
3 If s > 2 than most of the load (≈ ρ5%) is carried in the short directions, Fig. 7.3
4 Load transfer in one way slabs is accomplished hierarchically through an interaction of slab,

beam, girder, column and foundations, Fig. 7.4


Draft
7–2 ONE WAY SLABS

11111
00000
00000
11111 11111
00000
00000
11111
00000
11111 Beam 1 00000
11111
00000
11111 00000
11111
1111
0000 1111
0000
0000
1111
0000
1111 0000
1111
1111
0000 0000
1111
0000
1111

B B

Beam 2
Beam 1

Beam 2
Beam 1

1’−0" Strip 1’−0" Strip


B B

S S
L
1111
0000
0000
1111 0000
1111
0000
1111
0000
1111
0000 0000
1111
1111 0000
1111
11111
00000 11111
00000
00000
11111
00000
11111 Beam 1 00000
11111
11111
00000
00000
11111 11111
00000

Figure 7.2: One vs Two way slabs

ρB B
111
000
000
111

P ρA

A 1010 1
0
0
1A
0
1 0
1

000
111
B111
000

Figure 7.3: Load Distribution in Slabs

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
7.1 Types of Slabs 7–3

Figure 7.4: Load Transfer in R/C Buildings

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
7–4

Simply One end Both ends


ONE WAY SLABS

Cantilever
supported continuous continuous
Solid One
way slab L/20 L/24 L/28 L/10
Beams or
ribbed One way slab L/16 L/18.5 L/21 L/8

Table 7.1: Recommended Minimum Slab and Beam Depths

7.2 One Way Slabs

5 Preliminary considerations for one way slabs:


1. Load on slabs ksf.
2. Design an imaginary 12 in strip.
3. The area of reinforcement is As /ft of width or
 
As 12 in
= Ab (7.1)
ft bar spacing in inches

where Ab is the area of one bar. or


12Ab
Bar spacing in inches = (7.2)
As
4. Slab thickness t is usually assumed, and we design reinforcement. ACI 9.5.2.1 recom-
mended minimum thickness of beams/slabs are given by Table 7.1. where L is in inches,
and members are not supporting partitions. If a slab is so dimensioned
(a) Deflection need not be checked
(b) Usually, neither flexure, nor shear controls
a
5. In reinforcement design, a good initial guess for d is 0.15.
6. Slab thickness are rounded to the neares 1/4 inch for slabs less than 6 inch, and 1/2 for
thicker ones.
7. ACI Sect. 7.7.1 gives minimum cover for corrosion control
(a) Concrete not exposed to weather or in contact with ground, No.11 or smaller 3/4
inch.
(b) Concrete exposed to weather or in contact with ground:
i. No. 5 bars and smaller, 1.5 inch.
ii. No. 6 and larger, 2. inch.
8. Transverse reinforcement (shrinkage, temperature) must be provided

As 
0.002 Grade 40 and 50 bars
= ACI 7.12.2.1 (7.3)
bh 
0.0018 Grade 60 and welded wire fabric

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
7.3 Design of a One Way Continuous Slab


9. Shear does not usually control & no minimum reinforcement is needed (vc = 2 fc )
7–5

10. Principal reinforcement shall not be spaced at more than 3 times the slab thickness nor
18 in (ACI 7.6.5).

11. Usually No. 4 and larger bars are used for flexural reinforcement, as No. 3 may be
bent out of position by workers walking on it. This is more critical for top than bottom
reinforcement.

12. Sometimes, No.3 is used for bottom, and No. 4 for top.

13. Shrinkage/temperature reinforcement shall not be spaced at more than 5 times the slab
thickness nor 18 in (ACI 7.12.2.2).

7.3 Design of a One Way Continuous Slab


Design an 8 span floor slab. Each span is 15 ft long, fc = 3, 750 psi, fy = 60 ksi, wl =100 psf,
floor cover is 0.5 psf, mechanical equipment 4 psf, and ceiling 2 psf. Interior supporting beams
have a width of 14 inch, and exterior ones 16 inches. First span is measured from exterior of
exterior beam to center of first interior beam.

Thickness: of the floor is based on ACI recommendation:


16 14
le = (15)(12) − − = 165 in (7.4-a)
2 2
14
li = (15)(12) − 2 = 166 in (7.4-b)
2
l 165
hemin = = = 6.88 in (7.4-c)
24 24
l 166
himin = = = 5.93 in (7.4-d)
28 28
We round h up to h = 7.25 in. Assuming 3/4 in. cover and No. 4 bars
 
0.5
d = 7.25 − 0.75 + = 6.25 in (7.5)
2

Factored Loads Slab


7.25
wd = (150) = 90.6 psf of floor surface (7.6)
12
Total dead load 90.6 + 0.5 + 4 + 2 = 97.1 psf
Factored load
wu = 1.4(97.1) + 1.7(100) = 306 psf (7.7)
The load per foot of strip is 306 lbs/ft
Since wl < 3wd we can use the ACI 8.3.3 coefficients to compute the moments.

Net spans

1. First interior span ln = (15)(12) − 16


2 − 14
2 = 165 in = 13.75 ft

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
7–6

2. Second interior span ln = (15)(12) − 14 = 166 in = 13.83 ft


ONE WAY SLABS

3. Average span ln = 12 (165 + 166) 12


1
= 13.79 ft

Flexural Design

ai = 0.15d = 0.15(6.25) = 0.9375 in (7.8-a)


Mu 12Mu 0.222
As = = = Mu (7.8-b)
φfy (d − a2 ) 0.9(60)(6.25 − a2 ) 6.25 − a2
As fy 60
a = 
= As = 1.569As (7.8-c)
0.85fc b (0.85)(3.75)(12)
Amin
s = 0.0018bh = 0.0018(12)(7.25) = 0.157 in2 /f t (7.8-d)

For maximum spacing, ACI specifies 3h = 3(7.25) = 21.75 in but no more than 18 in,
⇒ smax = 18 in.

Support Midspan Support Midspan Support Midspan


ln , ft 13.75 13.75 13.79 13.83 13.83 13.83
wu ln2 57.85 57.85 58.19 58.53 58.53
M Coeff. 1/24 1/14 1/10 1/11 1/16 1/11 1/16

Mu ft-kip/ft 2.41 4.13 5.82 5.82 5.29 3.66 5.32 3.66
a 0.937 0.937 0.937 0.937 0.937
As 0.092 0.159 0.223 0.141 0.204
a 0.145 0.249 0.351 0.221 0.320
As 0.087 0.150 0.213 0.132 0.194
a 0.136 0.235 0.334 0.207 0.304
√ √
As 0.087 0.150 0.212 0.132 0.194
√ √ √
Amin
s 0.157 0.157 0.157 0.157 0.157
Reinf. #4@15 #4 @15 #4@12 #4@15 #4@12
Aprov
s 0.16 0.16 0.20 0.16 0.20

Shear Since we have unequal spans we must check at

1. Exterior face of the first interior support

ln (1.15)(306)(157)
Vu = 1.15wu = = 2, 302 lb/ft of width (7.9)
2 2
2. Typical interior span

ln (1.0)(306)(166)
Vu = 1.0wu = = 2, 117 lb/ft of width (7.10)
2 2
The shear resistance is
 
φVc = (0.85)2 f  cbw d = (0.85)(2) 3, 750(12)(6.25) = 7, 808lb/f t (7.11)

hence the slab is adequate for shear.

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
7.3 Design of a One Way Continuous Slab

Shrinkage and Temperature Reinforcement must be provided perpendicular to the span


7–7

of the slab
As = 0.0018bh = 0.0018(12)(7.25) = 0.157 in2 /f t (7.12)
and maximum spacing is 18 in. Therefore, we can provide # 4 bars at 15 in. as shrinkage
and temperature reinforcement. They should be placed on top of the lower layer of steel.

Note that in this problem a 6.5 in. thickness was acceptablee for the six interior spans, but a
7.25 in. thickness was required for the end spans.
If the entire floor were made of 6. in. thick slab instead of 7.25 in. about 45 cubic yards of
concrete could have been saved (for a total floor width of about 90 ft) per flor or 180 kips of
dead load per floor. This would represent a considerable saving in say a 20 story building.
In this case, it would be advisable to use 6., and check for delfections in the end spans.

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
7–8 ONE WAY SLABS

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft

Chapter 8

COLUMNS
Draft

Chapter 9

COLUMNS

9.1 Introduction

1 Columns resist a combination of axial P and flexural load M , (or M = P e for eccentrically
applied load).

9.1.1 Types of Columns


Types of columns, Fig. 9.1

Tied column Composite colu

tie steel
main longitudinal steel reinforcement
Pipe column

Spiral column

Figure 9.1: Types of columns

2 Lateral reinforcement, Fig. 9.2


1. Restrains longitudinal steel from outward buckling

2. Restrains Poisson’s expansion of concrete

3. Acts as shear reinforcement for horizontal (wind & earthquake) load

4. Provide ductility
very important to resist earthquake load.

9.1.2 Possible Arrangement of Bars

3 Bar arrangements, Fig. 9.3


Draft
9–2 COLUMNS

P
Spiral
X Tied X

Figure 9.2: Tied vs Spiral Reinforcement

4 bars 6 bars 8 bars

Corner column

10 bars
12 bars

Wall column

16 bars

14 bars

Figure 9.3: Possible Bar arrangements

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
9.2 Short Columns

9.2 Short Columns


9–3

9.2.1 Concentric Loading

4 No moment applied,
Elastic Behaviour
P = fc Ac + fs As
= fc (Ac + nAs )

Ultimate Strength
Pd = φPn
Pn = .85fc Ac + fy As
note:
1. 0.85 is obtained also from test data
2. Matches with beam theory using rect. stress block
3. Provides an adequate factor of safety

9.2.2 Eccentric Columns

5 Sources of flexure, Fig. 9.4


P
n

e P L R
M M
ML MR

L R
e=
M − M
P
n

Figure 9.4: Sources of Bending

1. Unsymmetric moments M L = M R
2. Uncertainty of loads (must assume a minimum eccentricity)
3. Unsymmetrical reinforcement

6 Types of Failure, Fig. 9.5


1. Large eccentricity of load ⇒ failure by yielding of steel
2. Small eccentricity of load ⇒ failure by crushing of concrete
3. Balanced condition

As
7 Assumptions As = As ; ρ = As
bd = bd = fs = fy

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
9–4

Pn
COLUMNS

ε cu
ε cu
P
0

Compression
8 failure range
e = 0; a = h; c =
Radial lines show
Mn Balanced Failure
constant e=
e small Pn ε cu
ε
y

Load path for


givin e Tension failure
eb range
c e
e large ε cu
ε > εy
c ~ h; e=
Mn su
8

M
0

Figure 9.5: Load Moment Interaction Diagram

9.2.2.1 Balanced Condition

M
8 There is one specific eccentricity eb = P such that failure will be triggered by simultaneous
1. steel yielding
2. concrete crushing

9 From the strain diagram (and compatibility of concrete and steel strains), Fig. 9.6

εc = .003 (9.1-a)
fy
εy = (9.1-b)
Es
εu .003
c = d= fy
d (9.1-c)
εu + εy + .003
Es
(9.1-d)
Furthermore,
εs εc
= (9.2-a)
c − d c
c − d
⇒ εs = εc (9.2-b)
c
thus the compression steel will be yielding (i.e. εs = εy ) for εc = .003 and d = 2 in if c > 6 in
10 Equilibrium:
 Pn 
Pn = .85fc ab + As fy − As fs  a = .85fc b 
 .003
fs = fy a = β1 cb Pn,b = .85β1 fc bd fy (9.3)
  c = .003
d 
 + .003
As = As b fy
+.003
Es
Es

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
9.2 Short Columns

d’
9–5

d
h/2

A A’
s s
b

εs εcs ε’s

A sf y Pn
A sf s
c
c
A sf s

0.85f’c
A’sf s
A’sf y
a
e
e’

Figure 9.6: Strain and Stress Diagram of a R/C Column

or
87, 000
Pnb = .85β1 fc bd (9.4)
fy + 87, 000

11To obtain Mnb we take moment about centroid of tension steel As of internal forces, this
must be equal and opposite to the externally applied moment, Fig. 9.6.

a
Mnb = Pnb eb = .85fc ab(d − ) + As fy (d − d )
   2  (9.5)
M
 
ext
Mint

12 Note: Internal moments due to As fy and As fy cancel each other for symmetric columns.

9.2.2.2 Tension Failure


Case I, e is known and e > eb

In this case a and Pn are unknowns, and for failure to be triggered by fy in As we must
have e > eb .
Can still assume As fy = As fy
Pn
ΣFy = 0 ⇒ Pn = .85fc ab ⇒ a = (9.6-a)
.85fc b

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
9–6

a
COLUMNS

ΣM = 0 ⇒ Pn e = Pn (d − ) + As fy (d − d ) (9.6-b)


2

Two approaches

1. Solve iteratively for those two equations


(a) Assume a (a < h2 )
(b) From strain compatibility solve for fsc , center steel stress if applicable.
(c) ΣFy = 0 ⇒ solve for Pn
(d) ΣM = 0 with respect to tensile reinforcement,⇒ solve for Pn
(e) If no convergence among the two Pn , iterate by solving for a from ΣFy = 0
2. Combine them into a quadratic equation in Pn
  
  
2   
 

e e d e
Pn = .85fc bd −ρ − ( − 1) + 1− + 2ρ µ 1 − + (9.7)
 d d d d 

where
As As
ρ = bd = bd
fy
µ = .85fc

Case II c is known and c < cb ; Pn is unknown

In this case, we only have two unknown, Pn and fs .

a = β1 c (9.8-a)
def
fs = fy (9.8-b)
c− d
fs = εc E s ≤ fy (9.8-c)
c

C = 0.85fc ab (9.8-d)
Pn = C+ As fs
− As fy (9.8-e)
   
h−a   h  h
Mn = C + as fs − d + As fs d − (9.8-f)
2 2 2
Mn
e= (9.8-g)
Pn
Note this approach is favoured when determining the interaction diagram.

9.2.2.3 Compression Failure


Case I e is known and e < eb ; Pn , a and fs are unknown

Compression failure occurs if e < eb ⇒ εu = .003, assume fs = fy , and fs < fy
From geometry
εu
c = fs
d
Es + εu

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
9.2 Short Columns

d−c
9–7

⇒ fs = Es εu
c
d − βa1
= E s εu a (9.9-a)
β1
Pn = .85fc ab + As fy − As fs (9.9-b)
a
Pn e = .85fc ab(d − ) + As fy (d − d ) (9.9-c)
2
this would yield a cubic equation in Pn , which can be solved analytically or by iteration.

1. Assume a (a  h)
2. Solve for ΣM = 0 with respect to tensile reinforcement & solve for Pn
3. From strain compatibility solve for fs
4. Check that ΣFy = 0 & solve for a
5. If ai+1 = ai go to step 2

Case II: c is known and c > cb ; fs , fs , and Pn are unknown

In this case

a = β1 c (9.10-a)
d−c
fs = εc Es ≤ fy (9.10-b)
c
c − d
fs = εc Es ≤ fy (9.10-c)
c
C = 0.85fc ab (9.10-d)
Pn = C + As fs + As fs (9.10-e)
   
h−a   h  h
Mn = C + As fs − d + As fs d − (9.10-f)
2 2 2

9.2.3 ACI Provisions


1. Governing equations

ρmin = 1% ACI 10.9.1


ρmax = 8%
A 
ρs = 0.45( Agc − 1) ffyc ACI 10.5 (9.11)
φ = 0.7 for tied columns
φ = 0.75 for spiral columns

where
ρs minimum ratio of spiral reinforcement
Ag gross area of section
Ac area of core
2. A minimum of 4 bars for tied circular and rect

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
9–8

3. A minimum of 6 bars for spirals (ACI10.9.2)


COLUMNS

4. φ increases linearly to 0.9 as φPn decreases from 0.10fc Ag or φP0 , whichever is smaller,
to zero (ACI 9.3.2).

5. Maximum strength is 0.8φP0 for tied columns (φ = 0.7) and 0.85φP0 for spirally reinforced
columns (φ = 0.75).

9.2.4 Interaction Diagrams

13 Each column is characterized by its own interaction diagram, Fig. 9.7

Tied: Pn(max) = 0.80 P0


P
Spir. reinf: P n(max) = 0.85 P0
Compression
control region
P0
A 1
P n(max) e
re
df ailu
n’ Pn ) ance
P n−M n (M
Bal
φ Pn(max)

P d −M d Tension
n
mi

(M Pnb )
control region
e

nb’
eb

0.10f’ c A g

0 φM n Mn M

Figure 9.7: Column Interaction Diagram

9.2.5 Design Charts

14 To assist in the design of R.C. columns, design charts have been generated by ACI in term
Pn Mn χe As +As
of non dimensionalized parameters χ = bhf  vs bh2 f  = h for various ρt where ρt = bh and
c c
fy
µ= .85fc

Example 9-1: R/C Column, c known

A 12 by 20 in. column is reinforced with four No. 4 bars of area 1.0 in2 each, at each
corner. fc = 3.5 ksi, fy = 50 ksi, d = 2.5 in. Determne: 1) Pb and Mb ; 2) The load and moment
for c = 5 in; 3) load and moment for c = 18 in.
Solution:

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
9.2 Short Columns

Balanced Conditions is derived by revisiting the fundamental equations, rather than mere
9–9

substitution into previously derived equation.

d = h − d = 20 − 2.5 = 17.5 in (9.12-a)


.003 .003
cb = fy
d = 50 17.5 = 11.1 in (9.12-b)
E + .003 29,000 + .003
s

a = β1 cb = (0.85)(11.1) = 9.44 in (9.12-c)


def
fs = fy = 50 ksi (9.12-d)
c−d  11.1 − 2.5
fs = Es εc = (29, 000)( (0.003) = 67.4 ksi > fy ⇒ fs = 50(9.12-e)
ksi
c 11.1
C = 0.85fc ab = (0.85)(3.5)(9.44)(12) = 337 k (9.12-f)
Pnb = C + As fs − As fs = 337 + (2.0)(50) + (2.0)(−50) = 337 k (9.12-g)
a
Mnb = Pnb e = .85fc ab(d − ) + As fy (d − d ) (9.12-h)
  2
9.44
= 337 17.5 − + (2.0)(50)(17.5 − 2.5) = 5, 807 k.in = 484 k.ft (9.12-i)
2
5, 807
eb = = 17.23 in (9.12-j)
337

Tension failure, c = 5 in
def
fs = fy = 50 ksi (9.13-a)
c − d
fs = εc E s ≤ fy (9.13-b)
c
5.0 − 2.5
= (0.003)(29, 000) = 43.5 ksi (9.13-c)
5.0
a = β1 c = 0.85(5.0) = 4.25 in (9.13-d)
C = 0.85fc ab (9.13-e)
= (0.85)(3.5)(4.25)(12) = 152 k (9.13-f)
Pn = C+ As fs − As fy (9.13-g)
= 152 + (2.0)(43.5) − (2.0)(50) = 139 k (9.13-h)
   
h−a h h
Mn = C + As fs − d + As fs d − about section centroid (9.13-i)
2 2 2
     
20 − 4.25 20 20
= (152) + (2.0)(43.5) − 2.5 + (2.0)(50) 17.5 − (9.13-j)
2 2 2
= 2, 598 k.in = 217 k.ft (9.13-k)
2, 598
e = = 18.69 in (9.13-l)
139

Compression failure, c = 18 in

a = β1 c = 0.85(18) = 15.3 in (9.14-a)


d−c
fs = εc Es ≤ fy (9.14-b)
c
Victor Saouma Mechanics and Design of Reinforced Concrete
Draft
9–10

17.5 − 18.0
COLUMNS

= (0.003)(29, 000) = −2.42 ksi As is under compression (9.14-c)


18.0
c − d
fs = εc Es ≤ fy (9.14-d)
c
18.0 − 2.5
= (0.003)(29, 000) = 75 ksi > fy ⇒ fs = 50 ksi (9.14-e)
18.0
C = 0.85fc ab = (0.85)(3.5)(15.3)(12) = 546 k (9.14-f)
Pn = C + As fs + As fs (9.14-g)
= 546 + (2.0)(50) + (−2.42)(2) = 650 k (9.14-h)
   
h−a h h
Mn = C + As fs − d + As fs d − about section centroid (9.14-i)
2 2 2
     
20 − 15.3 20 20
= (546) + (2.0)(50) − 2.5 + (2.0)(−2.42) 17.5 − (9.14-j)
2 2 2
= 2, 000 k.in = 167 k.ft (9.14-k)
2, 000
e = = 3.07 in (9.14-l)
650

Example 9-2: R/C Column, e known

For the following column, determine eb , Pb , Mb ; Pn and Mn for e = 0.1h and e = h.


fc = 3, 000 psi and fy = 40, 000 psi. The area of each bar is 1.56 in2 .

12"

20"

3" 3"

24"

c
εy
.003

Cc

Balanced Condition:
fy 40
εy = = = .001379 (9.15-a)
Es 29, 000
Victor Saouma Mechanics and Design of Reinforced Concrete
Draft
9.2 Short Columns

εu .003
9–11

cb = d= .003 = 14.4 in (9.15-b)


εu + εy .003 + .001379
a = β1 cb = (.85)(14.4) = 12.2 in (9.15-c)
Cc = .85fc ab
= (.85)(3)(12.2)(20) = 624 k (9.15-d)
14.4 − 12
εsc = .003 = .0005 (9.15-e)
14.4
fsc = (29, 000)(.0005) = 15 ksi center bars (9.15-f)
Cs = (.0005)(29, 000)(2)(1.56) = 46.8 k (9.15-g)
Pnb = 624 + 46.8 = 670.8 k (9.15-h)

Note that the co0mpression steel is yielding because d > 2” and c > 6” (as previously
proven)
Taking moment about centroid of section

Mnb = Pnb e (9.16-a)


     
h a h h
= .85fc ab −
+ As fy − d + As fy − d (9.16-b)
2 2 2 2
 
12.2
= (.85)(3)(12.2)(20) 12 − + 4(1.56)(9)(40)
2
+4(1.56)(40 − .85 × 3)(12 − 3) (9.16-c)
= 3, 671 + 2, 246 + 2, 246 (9.16-d)
= 8, 164 k.in; 680 k.ft (9.16-e)
8, 164
eb = = 12.2 in (9.16-f)
670.8

e= .1 h e = (.1)(24) = 2.4 in < eb ⇒ failure by compression. Pn , a and fs are unknown

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
9–12 COLUMNS

12"

20"

3" 3"

h−c−d’ 24"

c=23.5"
εy
ε ε ε
s sc y
.003
e=2.4"
9"
Pn
e’=11.4 h/2=12"

.85f’c
A sf s
A scf Cc A’ sf y
sc

a=20" a/2

1. Assume a = 20 in
a 20
c= = = 23.5 in (9.17)
β1 .85
2. For center steel (from geometry)
εsc .003
= (9.18-a)
c − h2 c
c − h2
⇒ εsc = .003 (9.18-b)
c
fsc = Es εsc (9.18-c)
c− h
2
= Es .003 (9.18-d)
c
23.5 − 12
= 29, 000 .003 = 42.5 ksi > fy ⇒ fsc = fy (9.18-e)
23.5
3. Take moment about centroid of tensile steel bar
a h
Pn e = 0.85fc ab(d − ) + As fy (h − 2d ) + Asc fy ( − d ) (9.19-a)
2 2
Victor Saouma Mechanics and Design of Reinforced Concrete
Draft
9.2 Short Columns

20
9–13

Pn (9 + 2.4) = (.85)(3)(20)(20)(21 − ) + 4(1.56)(40)(24 − 6) + 2(1.56)(40)(9)


(9.19-b)
2
= 11, 220 + 4, 493 + 259.7 (9.19-c)
⇒ Pn = 1, 476 k (9.19-d)

4. Get εs in tension bar


εs .003
= (9.20-a)
d
h − − 23.5 c
.003
⇒ εs = (24 − 3 − 23.5) (9.20-b)
23.5
= −.000319 (9.20-c)
fs = Eεs = (29, 000)(0.000319) = 9.25 ksi (9.20-d)

5. Take ΣF = 0 to check assumption of a


Pn = 0.85fc ab + As fy + Asc fsc + As fy (9.21-a)
1, 476 k = (.85)(3)(a)(20) + (4)(1.56)(40) + (2)(1.56)(40) + (4)(1.56)(9.25)
(9.21-b)
1, 476 = 51a + 432.1 (9.21-c)

⇒ a = 20.4 in (9.21-d)
Pn = 1, 476 k (9.21-e)
Mn = (1, 476)(2.4) = 3, 542 k.in = 295 k.ft (9.21-f)

e=h 1. In this case e = 24 in > eb ⇒ failure by tension. Pn and a are unknown.


2. Assume a = 7.9 in ⇒ c = a
β1 = 7.9
.85 = 9.3 in
3. Steel stress at centroid
c 12 − c
= (9.22-a)
.003 εsc
12 − 9.3
⇒ εsc = .003 = .00087 (9.22-b)
9.3
⇒ fsc = (29, 000)(0.00087) = 25.3 ksi (9.22-c)

4. Iterate
ΣF = 0 ⇒ Pn = (.85)fc ab + Asc fsc (9.23-a)
= (.85)(3)(7.9)(20) − 2(1.56)(25.3) (9.23-b)
= 403 − 79 = 324 k (9.23-c)
a
ΣM = 0 ⇒ Pn (e + h/2 − d ) = .85fc ab(d − ) + As fy (d − d )
2
d − d
−Asc fsc ( ) (9.23-d)
2
7.9
Pn (24 + 9) = (.85)(3)(7.9)(20)(21 − ) + 4(1.56)(40)(21 − 3)
2
+2(1.56)(25.3)(9) (9.23-e)
Pn (33) = 6, 870 + 4, 493 − 710 = 10, 653 k.in (9.23-f)

⇒ Pn = 323 k (9.23-g)

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
9–14

5. Determine Mn
COLUMNS

Mn = Pn e = (323)(24) = 7, 752 k.in = 646 k.ft (9.24)

Example 9-3: R/C Column, Using Design Charts

Design the reinforcement for a column with h = 20 in, b = 12 in, d = 2.5 in, fc = 4, 000 psi,
fy = 60, 000 psi, to support PDL = 56 k, PLL = 72 k, MDL = 88 k.ft, MLL = 75 k.ft,
Solution:

1. Ultimate loads
201
Pu = (1.4)(56) + (1.7)(72) = 201 k ⇒ Pn = = 287 k (9.25-a)
0.7
251
Mu = (1.4)(88) + (1.7)(75) = 251 k.ft ⇒ Mn = = 358 k.ft (9.25-b)
0.7

2. Chart parameters

e (358)(12)
= = 0.75 (9.26-a)
h (287)(20)
h − 2d 20 − (2)(2.5)
γ = = 0.75 ⇒ interpolate between A3 and A(9.26-b)
4
h 20
Pn 287
κ = 
= = 0.3 (9.26-c)
bhfc (12)(20)(4)
e
κ = (0.3)(0.75) = 0.225 (9.26-d)
h

3. Interpolating between A.3 and A.4 ⇒ ρt µ = 0.4

4. Reinforcement

ρt = At
bh (0.4)(b)(h)(.85)(fc ) 1 2
fy At = = (0.4)(12)(20)(.85)(4) = 5.45 in(9.27-a)
µ = .85fc fy (60)

⇒ use 4 # 9 & 2 # 8, ⇒ At = 5.57 in2

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
9.2 Short Columns

Pn
9–15

1111111
0000000
0000000
1111111
0000000
1111111
0000000
1111111
0000000
1111111
0000000
1111111
0000000
1111111
0000000
1111111
0000000
1111111 M0y
M0x 0000000
1111111
0000000
1111111
0000000
1111111
0000000
1111111
0000000
1111111
0000000
1111111
0000000
1111111
0000000
1111111
0000000
1111111
0000000
1111111 Mny
0000000
1111111
0000000
1111111
Mnx

Figure 9.8: Failure Surface of a Biaxially Loaded Column

9.2.6 Biaxial Bending

15 Often columns are subjected to biaxial moments (such as corner columns)


16 An exact approach entails the trial and eror determination of an inclined neutral axis, this
is an exact method but too cumbersome to use in practice.
Hence, we seek an approximate solution, the most widely used method is the load contour
17

method or Bresler-Parme method.


18The failure surface of a biaxialy loaded column is shown in Fig. 9.8, and the general nondi-
mensional equation for the moment contour at a constant Pn may be expressed as
   
Mnx α1 Mny α1
+ = 1.0
M0x M0y

where
Mnx = Pn ey
Mny = Pn ex
M0x = Mnx capacity at axial load Pn when Mny (or ex ) is zero
M0y = Mny capacity at axial load Pn when Mnx (or ey ) is zero
and α1 and α2 are exponent which depend on geometry and strength.
19 Bresler suggested that we set α1 = α2 = α. For practical purposes, a value of α = 1.5 for
rectangular columns, and between 1.5 and 2.0 for square sections has proven acceptable.
20 An improvement of Bresler equation was devised by Parme. The main assumption is that at
any load Pn , Fig. 9.9
Mny M0y
=
Mnx M0x
or
Mnx = βM0x ; Mny = βM0y

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
9–16

M ny /M0y
COLUMNS

M ny βM 1.0
0x C
M 0y C
β B
B

M 0y βM 0y β
M0x
A
M0x M nx 45
o
A
1.0Mnx /M0x

Figure 9.9: Load Contour at Plane of Constant Pn , and Nondimensionalized Corresponding


plots

21 Thus, β is the portion of the uniaxial moment strength permitted to act simultaneously on
the column section. It depends on the cross section, strength, and layout.
22 The usual range is between 0.55 and 0.70, with a recommended value of 0.65 for design.
23 Hence, once β is selected, we can substitute in Bresler’s equation

α

M0x M0y α
βM 0x
+ β M0y = 1.0
β α = 12
α log β = log 0.5
α = log 0.5
log β

thus,
 log 0.5/logβ  log 0.5/logβ
Mnx Mny
+ = 1.0 (9.28)
M0x M0y

24 Effect of β is shown in Fig. 9.10.


25 Gouwens proposed to replace the above curves, by a bilinear model, Fig. 9.11

Review of a section
 
Mny Mnx 1 − β Mny Mnx
+ = 1 If ≥ (9.29-a)
M0y M0x β M0y M0x
 
Mnx Mny 1 − β Mny Mnx
+ = 1 If ≤ (9.29-b)
M0x M0y β M0y M0x

Design of a column
 
M0y 1−β Mny M0y
Mny + Mnx = M0y If ≥ (9.30-a)
M0x β Mnx M0x
  
M0x 1−β Mny M0y
Mnx + Mny = M0x If ≤ (9.30-b)
M0y β Mnx M0x

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
9.2 Short Columns 9–17

Biaxial Bending Interaction Diagram


1.0 0.90
0.
0.8 85
0.7 0
5
0.7
0
0.8 0.6
5
0.6
0
0.
be 55
ta
0.6 =0
.5
0
Nny/M0y

0.4

0.2

0.0
0.0 0.2 0.4 0.6 0.8 1.0
Mnx/M0x

Figure 9.10: Biaxial Bending Interaction Relations in terms of β

Pn β
111111
000000
000000
111111 C
000000
111111
000000
111111
M ny /M 0y + M nx /M 0x (1− β/ β ) =1

000000
111111
000000
111111
1.0
α α

000000
111111
000000
111111
1−β
B
(M nx /M 0x ) +(M ny /M 0y) =1

000000
111111
000000
111111
M0y β
M0x 000000
111111
0y

000000
111111
M ny /M

000000
111111
000000
111111
M nx /M 0x + M ny /M 0y (1− β/ β) =1
000000
111111
000000
111111
β
β
000000
111111
000000
111111
000000
111111
000000
111111
Mny 1−β

000000
111111
o
45
A
Mnx M nx /M 0x 1.0

Figure 9.11: Bilinear Approximation for Load Contour Design of Biaxially Loaded Columns

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
9–18

26 Note, circular or square columns with symmetric reinforcement should always be considered
COLUMNS

first for biaxially loaded columns.

Example 9-4: Biaxially Loaded Column

Determine the adequacy of a 16 in. square tied column with 8 # 9 bars. d = 2.5in, and there
are 3 bars on each side. The section is to carry factored loads of Pu = 144 k, Mux = 120 k.ft
and Muy = 54 k.ft, fc = 3 ksi and fy = 40 ksi. P0 = 952 k, M0x = M0y = 207 k.ft.
Solution:

Mux (120)(12)
ey = Pu = 144 = 10.0 in
Muy (54)(12)
ex = Pu = 144 = 4.5 in

The interaction diagram for e = 10 in, e = 4.5 in and e = 0 will give Pn equal to 254, 486, and
952 kips respectively.
The required load Pn = 144
0.7 = 205 k, the corresponding moments are M0x = M0y = 207 k.ft
from the interaction diagram. Using β = 0.65
120
Required Mnx 0.7
M0x = 207 = 0.828
54
Required Mny 0.7
M0y = 207 = 0.373

We shall use both solutions

Bresler-Parme which is exact solution


log(0.5) log 0.5
log β = log 0.65 = 1.609

log 0.5/logβ
log 0.5/logβ
Mnx M
M0x + Mny 0y
=

(0.828)1.609 + (0.373)1.609 = 0.943

Mnx Mny
Note that we could have first solved for M0x , and then determined M0y from Fig. 9.10.
Mny
This would have given M0y ≈ 0.45 which is greater than the actual value, hence the design
is safe.

Gouwens which is an approximate solution




Mny 1−β
Mnx
M0x + M0y β ≤1
 1−0.65 
0.828 + 0.337 0.65 = 0.828 + 0.1815 = 1.0095

which indicates a slight overstress.

We note that the approximate method is on the conservative side.

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
9.3 Long Columns

9.3 Long Columns


9–19

9.3.1 Euler Elastic Buckling

27Column buckling theory originated with Leonhard Euler in 1744. An initially straight mem-
ber is concentrically loaded, and all fibers remain elastic until buckling occur.
28 For buckling to occur, it must be assumed that the column is slightly bent as shown in Fig.
9.12. Note, in reality no column is either perfectly straight, and in all cases a minor imperfection
P P
x
x and y are
principal axes
x

Slightly bent position


L

Figure 9.12: Euler Column

is present.
29At any location x along the column, the imperfection in the column compounded by the
concentric load P , gives rise to a moment

Mz = −P y (9.31)

Note that the value of yis irrelevant.


30 Recalling that
d2 y Mz
2
= (9.32)
dx EI
upon substitution, we obtain the following differential equation

d2 y P
2
− =0 (9.33)
dx EI

P
31 Letting k 2 = EI , the solution to this second-order linear differential equation is

y = −A sin kx − B cos kx (9.34)

32 The two constants are determined by applying the essential boundary conditions

1. y = 0 at x = 0, thus B = 0

2. y = 0 at x = L, thus
A sin kL = 0 (9.35)

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
9–20

This last equation can e satisfied if: 1) A = 0, that is there is no deflection; 2) kL = 0, that is
COLUMNS

no applied load; or 3)
kL = nπ (9.36)
P
 2
Thus buckling will occur if EI = nπ L or

n2 π 2 EI
P =
L2

33The fundamental buckling mode, i.e. a single curvature deflection, will occur for n = 1; Thus
Euler critical load for a pinned column is

π 2 EI
Pcr = (9.37)
L2

The corresponding critical stress is


π2E
σcr =  2 (9.38)
L
r
where I = Ar.
34 Note that buckling will take place with respect to the weakest of the two axis.

9.3.2 Effective Length


kL kL
35 Large r column buckling, small r column crushing, Fig. 9.13.
Pfail
f
Pn
−1
tan E t

fp Pcr

Crushing Buckling
−1
tan E
ε (kl/r) lim (kl/r)

Figure 9.13: Column Failures

36 Recall from strength of material slenderness ratio


Le
λ=
r
.
I
where Le is the effective length and is equal to L
[ e = kL and r the radius of gyration (r = A ).

37 Le is the distance between two adjacent (fictitious or actual) inflection points, Fig. 9.13

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
9.3 Long Columns 9–21

P cr P cr Pcr

i.p.
l/4 i.p.
i.p.

<kl<l
kl=l kl= l l l
2

2
l
i.p.
l/4
i.p.
i.p.

P cr Pcr P cr

k=1 k=1/2 1/2<k<1

P Pcr P
cr cr
i.p.

l l<kl<
l i.p.
l 8

kl=21
kl=1
Pcr
Pcr Pcr
i.p.
l<kl<
8

i.p.

k=2 k=1

Figure 9.14: Critical lengths of columns

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
9–22

38 k is known for some simple highly idealized cases, but for most cases k depends on ΨA + ΨB
COLUMNS

(relative stiffnesses of columns to connected beams), Fig. 9.15

Σ( EI
L )of columns
Ψ= EI
(9.39)
Σ( L )of floor members

and k is then determined from the chart shown in Fig. 9.16.

P ( EI
( P P
2
( EI
( ln ∆
1
ln

A ψA
A ψA A ψA
( EI
(
2
ln
( EI
(
1
ln
MA MA
MA
MB
MB MB

B ψB
B ψB B ψB

Single curvature Double curvature

Braced Unbraced

Figure 9.15: Effective length Factors Ψ

9.3.3 Moment Magnification Factor; ACI Provisions

39 The critical stress in a column is given by


 
P π2E
=  2
A cr kL
r

40 Code recommends some minimum eccentricity to account for imperfectly placed load, Fig.
9.17
41 For an eccentrically placed load
1
Mmax = M0 (9.40)
1 − 1−P
P
  
cr

Moment magnification factor

42 The moment magnification factor reflects the amount by which the beam moment M0 is

magnified by the presence of an axial load, Fig. 9.18


43The previous equation assumes the presence of hinges at each end (Euler column). In the
most general case we will have
Cm
Mmax = M0 (9.41-a)
1 − PPcr
Victor Saouma Mechanics and Design of Reinforced Concrete
Draft
9.3 Long Columns 9–23

Sidesway Inhibited Sidesway Uninhibited

Ga K Gb Ga K Gb
∞ 1.0 ∞ ∞ ∞ ∞
50. 50. 20.
10. 10. 100. 10. 100.
50. 50.
5. 5.
30. 5. 30.
3. 0.9 3. 20. 20.
4.
2. 2.
10. 3. 10.
0.8 9. 9.
8. 8.
1. 1. 7. 7.
6. 6.
0.8 0.8
0.7 0.7 5. 5.
0.6 0.6 4. 2. 4.
0.7
0.5 0.5
0.4 0.4 3. 3.

0.3 0.3 2. 2.
0.6 1.5
0.2 0.2
1. 1.
0.1 0.1

0. 0.5 0. 0 1. 0

Figure 9.16: Standard Alignment Chart (ACI)

P e

Figure 9.17: Minimum Column Eccentricity

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
9–24

P
COLUMNS

φP 0

P0(max)
M P
C
P cr
M Pu
B
Pu e Pu ∆
Pn
P∆

in
em
M 0

M 0 M c = δM 2
kl/r
M0 Mn M 0 M2 Mc M

Figure 9.18: P-M Magnification Interaction Diagram

M1
Cm = .6 + .4 ≥ .4 (9.41-b)
M2
where
M1 is numerically smaller than M2 (not algebracially)
M1
M2 >0 if single curvature
M1
M2 <0 if double curvature
Cm < 1 if members are braced against sidesway
Cm =1 if members are not braced against sidesway
44 ACI Code
Lu unsupported length ACI 10.11.1
k ≤ 1.0 braced columns ACI 10.11.2
k ≥ 1.0 unbraced columns ACI 10.11.2
r = .3h rectangular x section ACI 10.11.3
r = .25d circular cross section
r < 34 − 12 M2
kLu M1
braced, neglect slenderness ACI 10.11.4
kL
r < 22 unbraced, neglect slenderness
45 From conventional elastic analysis get Pn &Mn

Mc = δM2 (9.42)
Cm
δ = ≥ 1.0 (9.43)
1 − φP
Pn
cr

π 2 EI
Pn = 10.11.5 (9.44)
(kLu )2
M1
Cm = .6 + 4 (9.45)
M2
Ec Ig
5 + Es Is
EI = (9.46)
1 + βd
Ec Ig
2.5
or EI = (9.47)
1 + βd
MD
βd = (9.48)
MD + ML

βd is the ratio of maximum design load moment to maximum design total load moment (always

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
9.3 Long Columns

+ve) as β  EI ⇒ dead load has a detrimental effect (creep)


9–25

Example 9-5: Long R/C Column

A 15 ft long, 14” circular column is connected to 40 ft long 14” by 22” beams. The column
is on the last floor, below it the column is circular and has a 16” diameter.
Given, Pn = 500 k, 14 × 22 has ρ = .015, fc = 5, 000 psi, fy = 40, 000 psi
Solution:

22
Lu = 15 ft − = 13.17 ft (9.49-a)
12
r = .25d = (.25)(14 in) = 3.5 in (9.49-b)
 
Ec = 57, 000 fc = 57, 000 5, 000 = 4, 030 ksi (9.49-c)
πd4 π(14)4
Ig = = = 1, 886 in4 (9.49-d)
64 64

Ec Ig 
EIcol = 2.5 1
1+βd EIcol = (4, 030)(1, 886) = 3, 040, 000 ksi (9.50-a)
βd = 0 2.5

 
EI 3, 040, 000
= = 16, 890 k.in (9.51-a)
L c (15)(12)
Ig (14)(22)3 1
Ibeam = Icr  = = 6, 210 in4 (9.51-b)
  2 12 2
EI (4, 030)(6, 210)
= = 52, 140 k.in (9.51-c)
L beam (12)(40)
Σ(EI/L)col 2(16, 890)
ΨA = = = .324 (9.51-d)
Σ(EI/L)beam 2(52, 140)
π(16)4
bottom column I = 64 = 3, 217 in4

(4, 030)(3, 217)


EI = = 5, 186, 000 (9.52-a)
  2.5
EI 5, 186, 000
= = 28, 800 k.in (9.52-b)
L col (15)(12)
16, 890 + 28, 800
ΨB = = .438 (9.52-c)
2(52, 140)
From ACI commentary ΨA = .324, ΨB = .438, ⇒ k  .65 and
kLu (.65)(13.16)(12)
= = 29.3 (9.53-a)
r 3.5
M1
34 − 12 = 34 − 12 = 22 assuming M1 = M2 (9.53-b)
M2
kL
> 22 ⇒ consider column instability (9.53-c)
r
Victor Saouma Mechanics and Design of Reinforced Concrete
Draft
9–26

π 2 EI π 2 (3, 040, 000)


COLUMNS

Pcr = = = 2, 848 k (9.53-d)


(kl) 2
[(.65)(13.16)(12)]2
M1
CM = .6 + .4 =1 (9.53-e)
M2
1 1
δ = = = 1.3 (9.53-f)
1 − φPcr
Pu
1 − (.75)(2,848)
500

Example 9-6: Design of Slender Column

Given: frame not braced, design AB as square column. PD = 46 k, MD = 92 k.ft, PL = 94 k,


ML = 230 k.ft, fc = 4 ksi, fy = 60 ksi

L 3
Lu =18’ l =43.3in

111
000
000
111 111
000
000
111
000
111 000
111

Solution:

Pu = 1.4 × 46 + 1.7 × 94 = 224 k (9.54-a)


Mu = 1.4 × 92 + 1.7 × 230 = 520 k.ft (9.54-b)
(1.4)92
βd = = .24 (9.54-c)
520
Assume a 22 × 22 inch column and ρt = .03
2.5

8.5

22"

22"

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
9.3 Long Columns

224
9–27

If = = 19, 500 in4 (9.55-a)


12
Is = (2)(.015)(22)2 (8.5)2 = 1, 050 in4 (9.55-b)

Ec = 57, 000 4, 000 = 3.6 × 106 psi (9.55-c)
Es = 29 × 10 ksi 6
(9.55-d)
Ec Ig
5 + Es Is
EI =
1 + βd
(3.6×106 )(19,500)
+ (29 × 106 )(1, 050)
= 5
= 3.59 × 1010 (9.55-e)
1 + .24
EIc 3.59 × 1010
= = 1.66 × 108 (9.55-f)
L 12 × 18
EIb
= (3.6 × 106 )(43.3) = 1.56 × 108 (9.55-g)
L
2(1.66 × 108 )
AtA&B Ψ = = 2.13 from ACI commentary k = 1.65 (9.55-h)
1.56 × 108
kL
if r = 22 neglect slenderness

r = (.3)(22) = 6.6 ∈ (9.56-a)


kL (1.65)(18)(12)
⇒ = = 54 > 22 (9.56-b)
r 6.6
π 2 EI π 2 (3.59 × 1010 )
Pcr = = = 279 × 106 lbs (9.56-c)
(kL)2 [(1.65)(18)(12)]2
Pu = 2.24 × 105 lb (9.56-d)
Cm = 1.0(unbraced) (9.56-e)
1 1
Moment Magnification δ = = (2.24×105 )
(9.56-f)
1 − φP
Pu
1−
cr (.7)(2.79×106 )
= 1.13 (9.56-g)

⇒ Moment for which the column is to be designed (1.13) (520) = 587 k.ft and Pu = 224

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
9–28 COLUMNS

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft

Chapter 10

PRESTRESSED CONCRETE

10.1 Introduction

1 Beams with longer spans are architecturally more appealing than those with short ones.
However, for a reinforced concrete beam to span long distances, it would have to have to be
relatively deep (and at some point the self weight may become too large relative to the live
load), or higher grade steel and concrete must be used.
2 However, if we were to use a steel with fy much higher than ≈ 60 ksi in reinforced concrete

(R/C), then to take full advantage of this higher yield stress while maintaining full bond between
concrete and steel, will result in unacceptably wide crack widths. Large crack widths will in
turn result in corrosion of the rebars and poor protection against fire.
3 One way to control the concrete cracking and reduce the tensile stresses in a beam is to
prestress the beam by applying an initial state of stress which is opposite to the one which will
be induced by the load.
4 For a simply supported beam, we would then seek to apply an initial tensile stress at the
top and compressive stress at the bottom. In prestressed concrete (P/C) this can be achieved
through prestressing of a tendon placed below the elastic neutral axis.
5 Main advantages of P/C: Economy, deflection & crack control, durability, fatigue strength,

longer spans.
6 There two type of Prestressed Concrete beams:

Pretensioning: Steel is first stressed, concrete is then poured around the stressed bars. When
enough concrete strength has been reached the steel restraints are released, Fig. 10.1.

Postensioning: Concrete is first poured, then when enough strength has been reached a steel
cable is passed thru a hollow core inside and stressed, Fig. 10.2.

10.1.1 Materials

7 P/C beams usually have higher compressive strength than R/C. Prestressed beams can have

fc as high as 8,000 psi.


8 The importance of high yield stress for the steel is illustrated by the following simple example.
Draft
10–2 PRESTRESSED CONCRETE

Vertical Harping
bulkhead Harping
hold-up hold-down
point point

Anchorage Jacks

Precast Concrete Continuous Casting bed


Prestressing
bed slab element tendon

Jacks Tendon
Jacks
anchorage

Casting bed Tendon


Support Hold-down
force force

Figure 10.1: Pretensioned Prestressed Concrete Beam, (?)

Anchorage Anchorage Jack


Intermediate Beam
diaphragms Jack

Tendon in conduct

Anchorage
Slab Jack

Wrapped tendon

Figure 10.2: Posttensioned Prestressed Concrete Beam, (?)

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
10.1 Introduction

If we consider the following:


10–3

1. An unstressed steel cable of length Ls


2. A concrete beam of length Lc
3. Prestress the beam with the cable, resulting in a stressed length of concrete and steel
equal to Ls = Lc .
4. Due to shrinkage and creep, there will be a change in length
∆Lc = (εsh + εcr )Lc (10.1)
we want to make sure that this amout of deformation is substantially smaller than the
stretch of the steel (for prestressing to be effective).
5. Assuming ordinary steel: fs = 30 ksi, Es = 29, 000 ksi, εs = 30
29,000 = 1.03 × 10−3 in/ in

6. The total steel elongation is εs Ls = 1.03 × 10−3 Ls


7. The creep and shrinkage strains are about εcr + εsh  .9 × 10−3
8. The residual stress which is left in the steel after creep and shrinkage took place is thus
(1.03 − .90) × 10−3 (29 × 103 ) = 4 ksi (10.2)
30−4
Thus the total loss is 30 = 87% which is unacceptably too high.
9. Alternatively if initial stress was 150 ksi after losses we would be left with 124 ksi or a
17% loss.
10. Note that the actual loss is (.90 × 10−3 )(29 × 103 ) = 26 ksi in each case

9 Having shown that losses would be too high for low strength steel, we will use
Strands usually composed of 7 wires. Grade 250 or 270 ksi, Fig. 10.3.
0000000
1111111
111111
000000
0000000
1111111
000000
111111
0000000
1111111
000000
111111
0000000
1111111
000000
111111
0000000
1111111
000000
111111
0000000
1111111
000000
111111
0000000
1111111
000000
111111
0000000
1111111
000000
111111
000000
111111 0000000
1111111
000000
111111 000000
111111
111111 0000000
1111111
000000
111111
000000
111111
000000 000000
111111
0000000
1111111
000000
111111
000000
111111
000000
111111 000000
111111
0000000
1111111
000000
111111
000000
111111
000000
111111 000000
111111
000000
111111
000000
111111
000000
111111000000
111111
000000
111111
000000
111111000000
111111
000000
111111
000000
111111000000
111111
000000
111111
000000
111111000000
111111
000000
111111
000000
111111000000
111111
0000000
1111111
0000000
1111111
000000
111111
000000
111111000000
111111
0000000
1111111
0000000
1111111
000000
111111
000000
111111000000
111111
0000000
1111111
0000000
1111111
000000
111111 000000
111111
0000000
1111111
0000000
1111111
0000000
1111111
0000000
1111111
0000000
1111111
0000000
1111111
0000000
1111111
0000000
1111111
0000000
1111111
0000000
1111111
0000000
1111111
0000000
1111111
0000000
1111111
0000000
1111111
0000000
1111111
0000000
1111111
0000000
1111111
0000000
1111111

Figure 10.3: 7 Wire Prestressing Tendon

Tendon have diameters ranging from 1/2 to 1 3/8 of an inch. Grade 145 or 160 ksi.
Wires come in bundles of 8 to 52.
Note that yield stress is not well defined for steel used in prestressed concrete, usually we take
1% strain as effective yield.
10 Steel relaxation is the reduction in stress at constant strain (as opposed to creep which
is reduction of strain at constant stress) occurs. Relaxation occurs indefinitely and produces
significant prestress loss. If we denote by fp the final stress after t hours, fpi the initial stress,
and fpy the yield stress, then
 
fp log t fpi
=1− − .55 (10.3)
fpi 10 fpy

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
10–4

10.1.2 Prestressing Forces


PRESTRESSED CONCRETE

11 Prestress force “varies” with time, so we must recognize 3 stages:

1. Pj Jacking force. But then due to

(a) friction and anchorage slip in post-tension


(b) elastic shortening in pretension

is reduced to:

2. Pi Initial prestress force; But then due to time dependent losses caused by

(a) relaxation of steel


(b) shrinkage of concrete
(c) creep of concrete

is reduced to:

3. Pe Effective force

10.1.3 Assumptions

12 The following assumptions are made;

1. Materials are both in the elastic range

2. section is uncracked

3. sign convention: +ve tension, −ve compression

4. Subscript 1 refers to the top and 2 to the bottom


I I
5. I, S1 = c1 , S2 = c2 , (section modulus)

6. e + ve if downward from concrete neutral axis

10.1.4 Tendon Configuration

13 Through proper arrangement of the tendon (eccentricity at both support and midspan)
various internal flexural stress distribution can be obtained, Fig. 10.4.

10.1.5 Equivalent Load

14An equivalent load for prestressing can be usually determined from the tendon configuration
and the prestressing force, Fig. 10.5.

10.1.6 Load Deformation

15 The load-deformation curve for a prestressed concrete beam is illustrated in Fig. 10.6.

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
10.1 Introduction 10–5

111
000
000
111
h 000
111
000
111
000
111
f’y

Q fc 2f c
fc
11
00
00
11 111
000
000
111 11
00
00
11
P h/2 00
11
00
11 + 000
111
000
111 = 00
11
00
11
P 00
11 000
111 00
11
fc fc =f t

2Q
0 2f c 2f c
11
00
00 +1111111
11 0000000
0000000
1111111 11
00
00
11
00
11
00
11 0000000
1111111
0000000
1111111 = 00
11
00
11
P 2h/3 00 1111111
11 0000000 00
11
P
2f c 2f =2f 0
t c

0 2f c 2f c
11
00
00 +1111111
11 0000000
0000000
1111111 11
00
00
11
00
11
00
11 0000000
1111111 = 00
11
00 1111111
0000000 00
11
2Q
11 0000000
1111111 00
11
2f c 2f t =2f c 0
fc fc
P Midspan 00
11
P 000
111 11
00
000 +
111
000
111 0 = 00
11
h/2 111
000 00
11
00
11
111
000
h/3 Ends fc
fc
0 f fc
c
00
11
00
11 000
111
111
000 00
11
11
00
Q 00
11 + 000
111 = 00
11
00
11
00
11 000
111
000
111 00
11
00
11
2f c ft =f c fc
P P Midspan
fc fc
h/2 00
11
00
11 00
11
00
11
00
11
00
11 + 0 = 00
11
00
11
h/3 00
11 00
11
fc Ends fc

Figure 10.4: Alternative Schemes for Prestressing a Rectangular Concrete Beam, (?)

Member Equivalent load on concrete from tendon Moment from prestressing

(a)
P θ P P sin θ P sinθ
P cos θ P cos θ
2P sin θ
(b)
θP P P sin θ P sin θ
P cosθ P cosθ

(c)
Pe Pe
P e P P
P

(d)
P P θM
P sin θ P sin θ M
e
P cos θ P cosθ

(e)
P PP P sinθ P sinθ
None
P cosθ P cosθ
2P sinθ

(f) P
P None

(g)
P P

Figure 10.5: Determination of Equivalent Loads

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
10–6

Load
PRESTRESSED CONCRETE

Ru
ptu
re
Steel yielding
Service load limit
including Overload
tolerable overload Tn
Service
load
First cracking load range

f cr
Decompression or higher
cgs (f=0)
Balanced

Full dead load

∆ ∆ ∆ Deformation ∆
o D L (deflection of camber)


∆ pi = Initial prestress camber
pe ∆ pe = Effective prestress camber
∆ O = Self−weight deflection
∆ ∆ D= Dead load deflection
pi
∆ L= Live load deflection

Figure 10.6: Load-Deflection Curve and Corresponding Internal Flexural Stresses for a Typical
Prestressed Concrete Beam, (?)

10.2 Flexural Stresses

16 We now identify the following 4 stages:


I
Initial Stage when the beam is being prestressed (recalling that r2 = Ac 1. the prestressing
force, Pi only

Pi Pi ec1 Pi
ec1
f1 = − + =− 1− (10.4)
Ac I Ac r2
Pi Pi ec2 Pi
ec2
f2 = − − =− 1+ 2 (10.5)
Ac I Ac r

2. Pi and the self weight of the beam M0 (which has to be acconted for the moment the
beam cambers due to prestressing)

Pi
ec1 M0
f1 = − 1− − (10.6)
Ac r2 S1
Pi
ec2 M0
f2 = − 1+ 2 + (10.7)
Ac r S2

Service Load when the prestressing force was reduced from Pi to Pe beacause of the losses,
and the actual service (not factored) load is apllied
3. Pe and M0

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
10.2 Flexural Stresses

Pe
ec1 M0
10–7

f1 = − 1− − (10.8)
Ac r2 S1
Pe
ec2 M0
f2 = − 1+ 2 + (10.9)
Ac r S2

4. Pe and M0 + MDL + MLL

Pe
ec1 M0 + MDL + MLL
f1 = − 1− − (10.10)
Ac r2 S1
Pe
ec2 M0 + MDL + MLL
f2 = − 1+ 2 + (10.11)
Ac r S2

The internal stress distribution at each one of those four stages is illustrated by Fig. 10.7.

Pi Pi e c 1 Pi e c1
(1- )
Ac Ic Ac r2
11
00 11111
00000
00
11 00000
11111 111111111
000000000
00
11 00000
11111 000000000
111111111
00
11
00
11 00000
11111 000000000
111111111
c1
00
11 00000
11111
00000
11111 000000000
111111111
00
11 00000
11111 000000000
111111111
00
11 00000
11111 000000000
111111111
00
11 00000
11111 000000000
111111111
00
11 00000
11111 000000000
111111111
000000000
111111111
00
11 00000
11111 000000000
111111111
e c2 00
11 00000
11111 000000000
111111111
00
11 00000
11111 000000000
111111111
00
11 00000
11111
00000
11111 000000000
111111111
00
11
00
11 00000
11111 000000000
111111111
00000
11111 000000000
111111111
Pi Pi e c 2 Pi e c2
Stage 1 (1+ )
Ac Ic Ac r2

Pi e c1 Mo Pi e c1 Mo
(1- ) - (1- )-
Ac r2 S1 Ac r2 S1
111111111
000000000 111111
000000
000000
111111
000000000
111111111 111
000 000000
111111
000000000
111111111 000
111 000000
111111
000000000
111111111 000
111 000000
111111
000000000
111111111
000000000
111111111 000
111 000000
111111
000000000
111111111 000
111 000000
111111
000000000
111111111 000
111 000000
111111
000000000
111111111 000
111 000000
111111
000000000
111111111 000
111
000
111 000000
111111
000000000
111111111 000
111 000000
111111
000000000
111111111 000
111 000000
111111
000000000
111111111 000
111 000000
111111
000000
111111
000000000
111111111 000
111 000000
111111
000000000
111111111 000
111 000000
111111
000000000
111111111 000
111
Pi e c2 Mo Pi e c2 Mo
(1+ ) + (1+ )+
Stage 2 Ac r2 S2 Ac r2 S2

Pe e c1 Mo Md + Ml Pe e c1 Mt
(1- )- - (1- )-
Ac r2 S1 S Ac r2 S1
111111
000000 11111111111
00000000000
1
000000
111111 00000000000
11111111111
00000000000
11111111111 111111
000000
000000
111111 00000000000
11111111111 000000
111111
000000
111111
000000
111111 00000000000
11111111111 000000
111111
000000
111111 00000000000
11111111111 000000
111111
000000
111111 00000000000
11111111111 000000
111111
000000
111111 00000000000
11111111111 000000
111111
000000
111111
000000
111111 00000000000
11111111111 000000
111111
000000
111111 00000000000
11111111111 000000
111111
000000
111111 00000000000
11111111111
00000000000
11111111111 000000
111111
000000
111111 00000000000
11111111111 000000
111111
000000
111111 00000000000
11111111111 000000
111111
000000
111111 00000000000
11111111111 000000
111111
000000
111111 00000000000
11111111111 000000
111111
000000
111111 000000
111111
Pe e c2 Mo Md + Ml Pe e c2 Mt
(1+ )+ + (1+ )+
Ac r2 S2 S2 Ac r2 S2
Stage 4

Figure 10.7: Flexural Stress Distribution for a Beam with Variable Eccentricity; Maximum
Moment Section and Support Section, (?)

17Those (service) flexural stresses must be below those specified by the ACI code (where the
subscripts c, t, i and s refer to compression, tension, initial and service respectively):

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
10–8 PRESTRESSED CONCRETE

fci permitted concrete compression stress at initial stage .60f 


ci
fti permitted concrete tensile stress at initial stage < 3 fci
fcs permitted concrete compressive stress at service stage .45f 
c 
fts permitted concrete tensile stress at initial stage 6 fc or 12 fc

Note that fts can reach 12 fc only if appropriate deflection analysis is done, because section
would be cracked.
18 Based on the above, we identify two types of prestressing:

Full prestressing (pioneered by Freysinet), no tensile stresses, no crack, but there are some
problems with excessive camber when unloaded.

Partial prestressing (pioneered by Leonhardt, Abeles, Thurliman), cracks are allowed to


occur (just as in R/C), and they are easier to control in P/C than in R/C.

19 The ACI code imposes the following limits on the steel stresses in terms of fpu which is the

ultimate strength of the cable: Pj < .80fpu As and Pi < .70fpu As . No limits are specified for
Pe .

Example 10-1: Prestressed Concrete I Beam

Adapted from (?)


The following I Beam has fc = 4, 000 psi, L = 40 ft, DL+LL =0.55 k/ft, concrete density
γ = 150 lb/ft3 and multiple 7 wire strands with constant eccentricity e = 5.19 in. Pi = 169 k,
and the total losses due to creep, shinkage, relaxation are 15%.
12"
4"
5"
2"

7" 6"
4"

24"

7" 6"

2"
5"
4"

The section properties for this beam are Ic = 12, 000 in4 , Ac = 176 in2 , S1 = S2 = 1, 000 in3 ,
r2= AI = 68.2 in2 .
Determine flexural stresses at midspan and at support at initial and final conditions.
Solution:

1. Prestressing force, Pi only


Pi
ec1
f1 = − 1− 2 (10.12-a)
Ac r
 
169, 000 (5.19)(12)
= − 1− = −83 psi (10.12-b)
176 68.2
Victor Saouma Mechanics and Design of Reinforced Concrete
Draft
10.2 Flexural Stresses

Pi
ec2
10–9

f2 = − 1+ 2 (10.12-c)
Ac r
 
169, 000 (5.19)(12)
= − 1+ = 1, 837 psi (10.12-d)
176 68.21

2. Pi and the self weight of the beam M0 (which has to be acconted for the moment the
beam cambers due to prestressing)

(176) in2
w0 = (.150) k/ ft3 = .183 k/ft (10.13-a)
(144) in2 / ft2
(.183)(40)2
M0 = = 36.6 k.ft (10.13-b)
8
The flexural stresses will thus be equal to:

w0 M0 (36.6)(12, 000)
f1,2 =∓ =∓ = ∓439 psi (10.14)
S1,2 1, 000

Pi
ec1 M0
f1 = − 1− 2 − (10.15-a)
Ac r S1
= −83 − 439 = −522 psi (10.15-b)
 √
fti = 3 fc = +190 (10.15-c)
Pi
ec2 M0
f2 = − 1+ 2 + (10.15-d)
Ac r S2
= −1, 837 + 439 = −1, 398 psi (10.15-e)

fci = .6fc = −2, 400 (10.15-f)

3. Pe and M0 . If we have 15% losses, then the effective force Pe is equal to (1 − 0.15)169 =
144 k
Pe
ec1 M0
f1 = − 1− 2 − (10.16-a)
Ac r S1
 
144, 000 (5.19)(12)
= − 1− − 439 (10.16-b)
176 68.2
= −71 − 439 = −510 psi (10.16-c)
Pe
ec2 M0
f2 = − 1+ 2 + (10.16-d)
Ac r S2
 
144, 000 (5.19)(12)
= − 1+ + 439 (10.16-e)
176 68.2
= −1, 561 + 439 = −1, 122 psi (10.16-f)

note that −71 and −1, 561 are respectively equal to (0.85)(−83) and (0.85)(−1, 837)
respectively.

4. Pe and M0 + MDL + MLL


(0.55)(40)2
MDL + MLL = = 110 k.ft (10.17)
8
Victor Saouma Mechanics and Design of Reinforced Concrete
Draft
10–10

and corresponding stresses


PRESTRESSED CONCRETE

(110)(12, 000)
f1,2 = ∓ = ∓1, 320 psi (10.18)
1, 000
Thus,
Pe
ec1 M0 + MDL + MLL
f1 = − 1− 2 − (10.19-a)
Ac r S1
= −510 − 1, 320 = −1, 830 psi (10.19-b)

fcs = .45fc = −2, 700 (10.19-c)
Pe
ec2 M0 + MDL + MLL
f2 = − 1+ 2 + (10.19-d)
Ac r S2
= −1, 122 + 1, 320 = +198 psi (10.19-e)
 √
fts = 6 fc = +380 (10.19-f)

5. The stress distribution at each one of the four stages is shown below.

-1830
-510
-522
-83

4 3 2 1
-1122

-1398

-1837
+198

10.3 Case Study: Walnut Lane Bridge


Adapted from (?)
20 The historical Walnut Lane Bridge (first major prestressed concrete bridge in the USA) is
made of three spans, two side ones with lengths of 74 ft and a middle one of length 160 feet.
Thirteen prestressed cocnrete beams are placed side by side to make up a total width of 44
fet of roadway and two 9.25 feet of sidewalk. In between the beams, and cast with them, are
transverse stiffeners which connect the beams laterally, Fig. 10.8

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
10.3 Case Study: Walnut Lane Bridge 10–11

80 ft

CENTER
LINE
ELEVATION OF BEAM HALF

9.25’ 44 ’ ROAD 9.25’

SIDEWALK

BEAM CROSS SECTIONS TRANSVERSE DIAPHRAGMS

CROSS - SECTION OF BRIDGE

52"

10"
3" TRANSVERSE DIAPHRAGM
7" 10"

3’-3" 7" 6’-7"

6 1/2" SLOTS FOR CABLES


3 1/2"
7"
30"
CROSS - SECTION OF BEAM

Figure 10.8: Walnut Lane Bridge, Plan View

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
10–12 PRESTRESSED CONCRETE

52"

8.9"

22.5" 7" 22.5"

6’-7"
61.2" = 79"

8.9"

SIMPLIFIED CROSS - SECTION OF BEAM

Figure 10.9: Walnut Lane Bridge, Cross Section

10.3.1 Cross-Section Properties

21 The beam cross section is shown in Fig. 10.9 and is simplified

Ac = 2(8.9)(52) + (7)(61.2) = 1, 354 in2 (10.20-a)


'   (
(52)(8.9)3 79 8.9 2 (7)(61.2)3
I = 2 + (52)(8.9) − + (10.20-b)
12 2 2 12
= = 1, 277 × 103 in4 (10.20-c)
h 79
c 1 = c2 = = = 39.5 in (10.20-d)
2 2
I 1, 277 × 103
S1 = S2 = = = 32, 329 in3 (10.20-e)
c 39.5
I 1, 277 × 103
r2 = = = 943. in2 (10.20-f)
A 1, 354

10.3.2 Prestressing

22 Each beam is prestressed by two middle parabolic cables, and two outer horizontal ones
along the flanges. All four have approximately the same eccentricity at midspan of 2.65 ft. or
31.8 inch.
23 Each prestressing cable is made up 64 wires each with a diameter of 0.27 inches. Thus the
total area of prestressing steel is given by:
0.276 in 2
Awire = π(d/2)2 = 3.14( ) = 0.0598 in2 (10.21-a)
2

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
10.3 Case Study: Walnut Lane Bridge

Acable = 64(0.0598) in2 = 3.83 in2


10–13

(10.21-b)
2 2
Atotal = 4(3.83) in = 15.32 in (10.21-c)

24 Whereas the ultimate tensile strength of the steel used is 247 ksi, the cables have been
stressed only to 131 ksi, thus the initial prestressing force Pi is equal to
Pi = (131) ksi(15.32) in2 = 2, 000 k (10.22)

25 The losses are reported ot be 13%, thus the effective force is


Pe = (1 − 0.13)(2, 000) k = 1, 740 k (10.23)

10.3.3 Loads

26 The self weight of the beam is q0 = 1.72 k/ft.


27 The concrete (density=.15 k/ ft3 ) road has a thickness of 0.45 feet. Thus for a 44 foot width,
the total load over one single beam is
1
qr,tot = (44) ft(0.45) ft(0.15) k/ ft3 = 0.23 k/ft (10.24)
13
28 Similarly for the sidewalks which are 9.25 feet wide and 0.6 feet thick:
1
qs,tot = (2)(9.25) ft(0.60) ft(0.15) k/ ft3 = 0.13 k/ft (10.25)
13
We note that the weight can be evenly spread over the 13 beams beacause of the lateral
diaphragms.
29 The total dead load is
qDL = 0.23 + 0.13 = 0.36 k/ft (10.26)

30 The live load is created by the traffic, and is estimated to be 94 psf, thus over a width of
62.5 feet this gives a uniform live load of
1
wLL = (0.094) k/f t2 (62.5) ft = 0.45 k/ft (10.27)
13
31 Finally, the combined dead and live load per beam is
wDL+LL = 0.36 + 0.45 = 0.81 k/ft (10.28)

10.3.4 Flexural Stresses


1. Prestressing force, Pi only
Pi
ec1
f1 = − 1− 2 (10.29-a)
Ac r
 
(2 × 10 )
6 (31.8)(39.5)
= − 1− = 490. psi (10.29-b)
1, 354 943.
Pi
ec2
f2 = − 1+ 2 (10.29-c)
Ac r
 
(2 × 106 ) (31.8)(39.5)
= − 1+ = −3, 445. psi (10.29-d)
1, 354 943.
Victor Saouma Mechanics and Design of Reinforced Concrete
Draft
10–14 PRESTRESSED CONCRETE

2. Pi and the self weight of the beam M0 (which has to be acconted for the moment the
beam cambers due to prestressing)
(1.72)(160)2
M0 = = 5, 504 k.ft (10.30)
8
The flexural stresses will thus be equal to:
w0 M0 (5, 50.4)(12, 000)
f1,2 =∓ =∓ = ∓2, 043 psi (10.31)
S1,2 943.

Pi
ec1 M0
f1 = − 1− 2 − (10.32-a)
Ac r S1
= 490 − 2, 043 = −1, 553 psi (10.32-b)
 √
fti = 3 fc = +190 (10.32-c)
Pi
ec2 M0
f2 = 1+ 2 + (10.32-d)
Ac r S2
= −3, 445 + 2, 043 = −1, 402. psi (10.32-e)

fci = .6fc = −2, 400 (10.32-f)

3. Pe and M0 . If we have 13% losses, then the effective force Pe is equal to (1−0.13)(2×106 ) =
1.74 × 106 lbs
Pe
ec1 M0
f1 = − 1− 2 − (10.33-a)
Ac r S1
 
1.74 × 106 (31.8)(39.5)
= − 1− − 2, 043. = −1, 616 psi (10.33-b)
1, 354 943.
Pe
ec2 M0
f2 = 1+ 2 + (10.33-c)
Ac r S2
 
1.74 × 106 (31.8)(39.5)
= − 1+ + 2, 043. = −954. psi (10.33-d)
1, 354 943.
4. Pe and M0 + MDL + MLL
(0.81)(160)2
MDL + MLL = = 2, 592 k.ft (10.34)
8
and corresponding stresses
(2, 592)(12, 000)
f1,2 = ∓ = ∓962. psi (10.35)
32, 329
Thus,
Pe
ec1 M0 + MDL + MLL
f1 = − 1− 2 − (10.36-a)
Ac r S1
= −1, 616 − 962. = −2, 578. psi (10.36-b)

fcs = .45fc = −2, 700 (10.36-c)
Pe
ec2 M0 + MDL + MLL
f2 = 1+ 2 + (10.36-d)
Ac r S2
= −954 + 962. = +8. psi (10.36-e)
 √
fts = 6 fc = +380 (10.36-f)

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
10.3 Case Study: Walnut Lane Bridge 10–15

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
10–16 PRESTRESSED CONCRETE

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft

Chapter 11

FOOTINGS

Read Text 12.1 to 12.4, ACI - Ch. 15, 11.12 31-1/5


Unedited

property line

Figure 11.1: xxx


Draft
11–2 FOOTINGS

P P
P

Figure 11.2: xxx

45

Figure 11.3: xxx

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft 11–3

g f

Two-way b c
4 d/2
4
Vc (
Vc= 2+
βc ( f’ c b0d
f’c b0d 2 Beam
Cl a d
Cs d
d/2
0 0.5 1.0 h e

Figure 11.4: xxx

A2

A1

Figure 11.5: xxx

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
11–4

f g
FOOTINGS

a b

9.5"

9.5"

9’-6"
Column
18"x18"

d c
19" 4.00’
2.42’
e h

9’-6"

11-#8 each way 18"


9’-0" long
#
8- 8 dowels
3’-6" long
9’-6"

18"

2’-0"

18"

3"
clear

9’-6"
9’-6"

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft 11–5

8-#7-6’-0" 13-#7-6’-0"

18"x24"

19’-6"
11-#9
top
Column 6’-6"

24" sq. col.

16-#7-6’-3"
Bottom

9"
18’-0" 4’-6"

Dowels same
as col. bars
Grade
3" clear

6’-0"
3" clear 3’-5"

2’-6" 2’-6"
3’-0"
23’-3"

1,149,000
23.25 = 49,400lb./ft.

16’-3" 3’-6"
1’-6" 418,000 lb
2’-0"

9.30’

173,000 lb
385,000 lb Shear
Diagram

0.05’ 3,630,000 in.-lb.

3,460,000 in.-lb.

21,400,000 in.-lb.
Moment diagram

REWRITE AND TAKE EXAMPLES FROM NILSON

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
11–6

Footings
FOOTINGS

figure

Isolated spread Wall footing


footing

Combined footing

Bearing capacity of soil

qa = 2, 000 psf 12, 000 psf Safety factor


 of 2.5 3.0
soft clay

Wall Footings

Similar to the design of a cantilever slab.

Example
DL = 10 k/f t (including the
wall weight)
LL + 5 k/f t

Masonry wall

Reinforced & concrete



fc = 3, 000 psi
fy = 40, 000 psi

qa = 4, 000 psf

Design the footing


Assume hf = 10 in.
12 × 150 pct = 125 psf
10
wf =
Effective bearing capacity qe = 4, 000 − 125 = 3, 875 psf

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
Consider a unit length of 12

11–7

← no need to apply ke
overload fact or XXee safety
factor is already including in qa .

15
Required b = 3.875 = 3.87 f t
use b = 4 f t.
Determine thickness hf → controlled by shear

Wu = 10 (1.4) + 5 (1.7) = 22.5 k/f t

22.5
qu = 4 = 5.625 ksf
= 5, 625 psf

 
V u = Vc = 2 fc bw d

Vu = φ Vc


2 − d)(5625) = 0.85 (2
( 4−1 5, 000)(12)(12)in“f t (d)

1.5 − d = 2.38 d

d = 0.44 f t = 5.32 in.

hf = 5.32 + 3 (cover) + 0.5 (radius 5/bar)


↑ ↑
ACI − 7.7.1 Assume # 8
= 8.82 in.

Use hf = 9 in.

Determine flexural Steel


critical section from masonary walls 




ACI −
critical section

 15.4.2
for concrete columns 


or walls

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
11–8

For Masonry Wall,


FOOTINGS

b 
a 2
Mu = 1
2 qu 2 − 4

 
1 2
= 1
2 (5.625) 2 − 4

= 8.61 f t − kips

Mn = Mu
φ = 8.61
0.9 = 9.57 f t − kips


φfy
Mn = φ (b)(d)2 fy 1 − 0.59 
fc



φ(40)
9.57 × 12 = φ (12)(5.32)2 (40) 1 − 0.59 3

93142 − 118 φ + 1 = 0

φ = 0.0091

As = (0.0291)(12)(5.32) = 0.58 in2

Use # 6 bars
Ab 12 0.44 × 12 
S = As /12 = As /Ab = 0.58 = 9.1

Smax = 3hf = 27 in. or 18 in − ak



Use # 6 @ 9

Development length Aab = √


0.04 Ab δy

fc

0.04(0.44)(40,000)
= √
3,000

= 12.85 in.

Ad = 12.85 × 0.8 = 10.3 in. < 2/in.


↑ ↑
bar spacing from critical
section to end

Column footings

figure

Failure Modes

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
1. Shear Failure - Punching Shear - two-way action
11–9

Beam Shear - one-way action

2. Flexure Failure - Bending in each direction

Shear Strength

Punching Shear

ACI − 11.12.2


Vc = 2+ 4
βc fc b0 d

b
βc = a for b > a

b0 = α[(a + d) + (b + d)]



or Vc = αs d
b0 + 2 fc b0 d

αs = 40 int. cols.

30 edge cols.

20 corner cols.

 
or Vc = 4 fc b0 d

Shear strength is larger under two-way action than under one-way action because of tri-axial
stress.

As βe → very large, Ve = 2 fc b d ← for beams

Beam Shear

Ve = 2 fc bd

← critical section

V u ≤ φ Vc

Moment Strength (ACI: Ch. 15)

figure

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
11–10

Reinf. in Band Width = 2


FOOTINGS

β+1
Total Reinf. in
short direction

:2
β = :1

Example

DL = 235 k, LL = 115 k


18 square


fc = 3, 000 psi
fy = 40, 000 psi
qc = 5, 500 psf
hf

7f t. (max.)


Assume hf = 2

Wf = (2)(150) = 300 psf

qe = 5, 500 − 300 = 5, 200 psf

(235+115)1,000 
Required A = 5,200 (7) = 9.6

 
Use A = 9 − 8

Determine hf

Pu = 235 (1.4) + 115 (1.7) = 525 kips

Pu 525 × 1,000
qu = A = (7)(9.67) = 7.756 psf

Punching Shear

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft 11–11

)  2 *
Vu = 7756 (7)(267) − 1812 + d
  
φ Vc = φ (2 + 4
βc ) fc b0 d or φ 4 fc b0

βc = 1

φ Vc = (0.85)(4) 3, 000 (4)(18 + 12d)(12)
  .
αs d
or φ Vc = + 2 fc b0 d
b0
  
will not be critical
φ Vc = Vu
/ 0
10 (7)(9.67) − ( 18
12 + d)
2 = (18 + 12d)(12d)

154 d2 + 246 d − 677 = 0


d = 1.4 f t = 17.3 in.

Beam Shear

 4−67 
Vu = 7, 756 2 − 9
12 − d (7)
 
φ Vc = φ 2 f bd

= (0.85)(2) 3, 000 (7 × 12)(12d)

0.528(4.085 − d) = d

d = 1.5 f t = 18 in.

use d = 18 in

hf = 18 + 3 (cover) + 0.5 (upper layer) + 1.0 (bottom layer)

= 22.5 in

Select hf = 23 in

Bending:

figure

Long direction:

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft
11–12 FOOTINGS

(4.085)2
Mu = 7.76 (7) 2 = 453 f t. − kips

Mn = Mu
φ = 504 f t. − kips ⇒ As = 8.5 in2
14 − #7

Short direction:

(2.75)2
Mu = 7.76 (9 − 67) 2 = 284 f t. − kips

Mn = 284
0.9 = 315 f t − kips = 5.5 in2
9 − #7

Min Reinf. ACI - 7.12

φg = 0.002

For one short direction, min As = 0.002 (9.67)(12)(23)


= 5.3 in2

Reinf. as Band Width 2 2


Total Reinf. = 1+β = 1+ 9.67
= 0.84
7

9 bars

8 − #7
  

figure

Check development length

min As = 0.005 Ag

gross area
of column
ACI − 15.8.2.1

Victor Saouma Mechanics and Design of Reinforced Concrete


Draft

Chapter 12

DEEP BEAMS

DEEP BEAMS

Examples of occurance

tanks

folded plates

Shear wall & diaphragms

figure

All of these are plane stress problems, and stresses can not be found by classical elastic
theory because plane sections do not remain plane after bending (Bernoville-Novier Hypothesis
is not valid any more).
need 20 analysis i) elasticity
ii) finite difference
iii) finite element
Deep beam design

figure

• Main differences between deep & shallow beams:

i) internal stress distribution before cracking


ii) location & orientation of cracks
iii) strength
iv) optimum reinforcement pattern

• Usually deep beams are shear critical & not flexure critical by reducing the span, momen-
tum reduced but shear remains constant
Draft
12–2

• Capacity to redistribute stresses is much higher in deep beams


DEEP BEAMS

M
• plane section do not remain plane ⇒ r = Iy + y = VIbQ are wrong
XX XX
& we have a warping of the x sections tend to relieve compressive stresse @ top
might get more than one neutral ones

stress trajectary

if no vertical compression with vertical compression

tension is much reduced


β < 45◦

• cracks will form at almost vertical directions & thus web reinforcement are not very
efficient ⇒ horz. steel more efficient main steel mostly distributed @ bottoms 13 depth

• After cracking, stress redistributions occurs

crack stopped by high −ve stresses

behaviour becomes similar to that of a tied crack.

J becomes irrelevant what cracking there is, as long as we have this mechanism.

m
before cracking fs = As J d

after cracking (arch mechanism)

• deflection for tied arch is larger than for beam (because stress is larger): but we need to
watch out for bond failure, are hooks or to be the steel out & find against the plate.

• better to use horizontal hook XXXXX instead of vertical hook because might have a
failure along weak face

figure

• FAILURE by

1. yielding of main longitudinal steel ← preferred use ρ < < ρbal.


2. crushing in high moment region
on the basis of test for beam beams εcu > > > .003  .008
mostly because simultaneous actions in compression XXXX
in any case beams would be underreinforced.
Victor Saouma Mechanics and Design of Reinforced Concrete
Draft 3. crushing of the concrete over the reactions XXXXXXXXXX
12–3

4. bond splitting failure


vu −φ vc
compare for normal beams = φ fy d bw
Av f y Av vu −vc
s = (vu −vc )bw or s = fy bw

for very deep beams :1n small


Arch is most effective
as :dn  effect of horzonital steel 

Ln
d


 Av ≥ .0015 bw S







 Avh ≥ .0025 bw S2

 

 S ≤ d
+ ≤ 18


5


 
S2 ≤ d
3 d ≤ 18 A.C.I. 11.9

SHEAR WALLS ACI 10.10

of very high better to incorporate shear walls.

Introduction

• Basic relations used:


a) Equilibrium i) Tension = compression Σ Fx = 0
ii) Mint = Mext ΣM = 0

b) Material Stress Strain

c) Compatibility of displacements (no slip)


• Basic assumptions used:
a) Perfect bond between steel & concrete εs = εc
b) Plain section remain plane ⇒ strain is
proportional to distance from N.A.
c) Neglect shrinkage & creep (for strength).
• Design: we are going to consider a reinforced concrete beam subjected to an increasing
load with:
a) sections uncracked
b) sections cracked, elastic → u.s.o.
c) sections cracked, inelastic → U.s.o.

Victor Saouma Mechanics and Design of Reinforced Concrete

You might also like