You are on page 1of 2

CEN-06-0208 Cable data sheet.

qxp 9/18/2007 8:15 AM Page 1

DATA SHEET

ESP SYSTEM CABLE


Centrilift electrical submersible pumping (ESP) system cable is the industry
standard for reliability and durability in challenging down-hole conditions.
Centrilift experts design and manufacture a complete line of cables specifically
for the oil and gas industry.
The Centrilift CEL cable is the best choice for extreme down-hole conditions,
featuring a special oil resistant EPDM rubber insulation for high dielectric Duralead™ CEL Flat
strength and excellent decompression resistance. The CPL cable is best
suited for cooler well conditions and features a specially formulated, rugged
polypropylene insulation for damage resistance and longer run life. Both CEL
and CPL designs employ a fatigue and corrosion resistant pure lead sheath over
the insulation for maximum flexibility and run life. The lead on both designs is
extruded on state-of-the-art equipment, using laser diameter controls for the
highest quality and consistency. These features make CEL and CPL cable ideal
for wells with high gas content or high levels of CO2 or H2S. Duralead™ CPL Flat

Centrilift employs a proprietary process to apply lead sheath directly over the
polypropylene insulation in CPL cables. For additional protection on CEL cable,
a bedding tape is used to protect the lead sheath during application of the
armor. The armor on all Centrilift cables is edge coated on all sides to provide
the industry’s best corrosion protection. CEL cable is applicable in a wide range
of temperatures from -40ºF (-40ºC) to 450ºF (232ºC) while CPL cable is rated
from -40ºF (-40ºC) to 257ºF (125ºC). CPN Round
For benign down-hole conditions, Centrilift CPN cable is the most cost effective
option. CPN cable features the best grade of polypropylene and a specially
formulated nitrile rubber jacket provides added physical protection from gas,
heat and pressure. Galvanized steel armor provides overall protection in both a
round and flat configuration. CPN cable is applicable in a temperature range
from -30°F (-34°C) to 205°F (96°C).
Centrilift also offers cables for special applications. Contact your local CPN Flat
Centrilift representative for more information.

FEATURES & BENEFITS


FEATURE BENEFIT

CEL: Oil resistant EPDM rubber insulation


>> Resists decompression to extend cable life

CPL: Rugged polypropylene insulation


>> Resists damage and degradation by well fluids

CPN: Oil resistant nitrile jacket


>> Protects insulation and extends life

Virgin lead sheath


>> Enhances flexibility and cable run life

Coated galvanized steel armor


>> Protects against corrosion from well fluids Centrilift cable development
and testing center

Solid copper conductor >> Prevents gas migration in the cable, easier
to splice, overall smaller diameter cable
CEN-06-0208 Cable data sheet.qxp 9/18/2007 8:16 AM Page 2

ESP SYSTEM CABLE

CPLF 5kV Flat -40°F (-40°C) to 257°F (125°C)


Conductor Insulation Jacket
Diameter Diameter Diameter Overall Dimension Weight Per
Part No. kV Rating Cond. Size inch mm inch mm inch mm inch mm Lb/Ft. Kg/M
76702 5 6-1 0.162 4.11 0.348 8.84 0.424 10.77 0.534 x 1.352 13.56 x 34.34 1.39 2.07
76643 5 4-1 0.204 5.18 0.390 9.91 0.466 11.84 0.576 x 1.479 14.63 x 37.57 1.65 2.46
76700 5 2-1 0.258 6.55 0.444 11.28 0.520 13.21 0.630 x 1.640 16.00 x 41.66 2.05 3.05
76701 5 1-1 0.289 7.34 0.476 12.09 0.552 14.02 0.662 x 1.736 16.81 x 44.10 2.29 3.40

CELF 5kV Flat -40°F (-40°C) to 450°F (232°C)


Conductor Insulation Jacket
Diameter Diameter Diameter Overall Dimension Weight Per
Part No. kV Rating Cond. Size inch mm inch mm inch mm inch mm Lb/Ft. Kg/M
76680 5 6-1 0.162 4.11 0.318 8.08 0.404 10.26 0.530 x 1.340 13.46 x 34.04 1.43 2.13
76679 5 4-1 0.204 5.18 0.360 9.14 0.446 11.33 0.590 x 1.521 14.99 x 37.06 1.64 2.44
76676 5 2-1 0.258 6.55 0.414 10.52 0.500 12.70 0.656 x 1.658 16.66 x 42.12 2.11 3.14
76675 5 1-1 0.289 7.34 0.446 11.33 0.532 13.51 0.687 x 1.752 17.45 x 44.50 2.36 3.51

CPN Flat -30°F (-34°C) to 205°F (96°C)


Conductor Insulation Jacket
Diameter Diameter Diameter Overall Dimension Weight Per
Part No. kV Rating Cond. Size inch mm inch mm inch mm inch mm Lb/Ft. Kg/M
76127 5 6-1 0.162 4.11 0.348 8.84 0.474 12.04 0.604 x 1.512 15.34 x 38.41 0.89 1.33
76128 5 4-1 0.204 5.18 0.390 9.91 0.516 13.11 0.646 x 1.639 16.41 x 41.63 1.10 1.64
76418 5 2-1 0.258 6.55 0.444 11.28 0.570 14.48 0.700 x 1.800 17.78 x 45.72 1.40 2.08
76417 5 1-1 0.289 7.34 0.476 12.09 0.602 15.29 0.731 x 1.894 18.57 x 48.11 1.59 2.37

CPN Round -30°F (-34°C) to 205°F (96°C)


Conductor Insulation Jacket
Diameter Diameter Diameter Overall Dimension Weight Per
Part No. kV Rating Cond. Size inch mm inch mm inch mm inch mm Lb/Ft. Kg/M
76151 5 6-1 0.162 4.11 0.348 8.84 0.940 23.88 1.090 27.69 0.92 1.37
76120 5 4-1 0.204 5.18 0.390 9.91 1.030 26.16 1.180 29.97 1.15 1.71
76414 5 2-1 0.258 6.55 0.444 11.28 1.147 29.13 1.297 32.94 1.50 2.23
76413 5 1-1 0.289 7.34 0.476 12.09 1.216 30.89 1.366 34.70 1.73 2.57

1 inch = 25.40 millimeters


1 pound per foot = 1.488 kilograms per meter
All finished dimensions are nominal, ± 0.040" tolerance
Weight is ± 8% tolerance
Materials and specifications are subject to change without notice
Stranded conductors will be supplied on request
Flat cable construction has 0.020" thickness, galvanized steel armor
Round cable construction has 0.025" thickness, galvanized steel armor

Centrilift World Headquarters


200 West Stuart Roosa Drive
Claremore, OK 74017-3095 www.bakerhughesdirect.com
800-633-5088
918-341-9600
©2007 Baker Hughes, Inc. All rights reserved. Duralead is a trademark of Baker Hughes, Inc. Printed in the U.S.A. CEN-06-0208 Revised 09-07