VISTA-128FBP/

V128FBP-24
Commercial Fire and Partitioned Burglary
Alarm Control Panel

Designed to integrate seamlessly with CCTV, access keypads, RF receivers and relays are supported by

control, and ADEMCO’s full range of fire and burglary extremely powerful control platform. The VISTA-128FBP

components, the NEW VISTA-128FBP provides the has been designed to mount quickly and easily in an

ultimate protection of life and property. The UL listed attack resistant cabinet, and is available in 12V and 24V

Commercial Fire and Burglary Control Platform controls models. A revolutionary new feature called Panel Linking

up to eight partitions, and supports up to 128 allows multiple partitions, panels – even buildings to be

zones/points using hardwired, wireless and V-Plex armed, disarmed and have status checked from one

addressable technologies. A diverse line of ADEMCO location.

initiating devices, notification circuits, digital dialers,

F E AT U R E S
• Eight hardwired zones standard, • Supports CCTV applications with • Supports Remote Control-via the
expandable to 120 V-Plex the new VistaView-100 CCTV internet**
addressable points/zones or 128 Switcher Module
• Supports Internet Alarm
wireless points/zones
• Identifies the point or zone of a Reporting**
• Can control eight separate areas fire or alarm, using the new FSA-
• Supports the new Graphical User
independently (8 partitions) 8/FSA-24 Fire System Annunciator
Interface Consoles
• Supports Panel-Linking allows up • Programmable to meet SIA false
• Supports up to 250 access card
to 8 systems or buildings to be alarm prevention specifications.
holders using VistaKey
controlled from one central To meet UL approval forANSI/SIA
location (using VA8200) CP-01-2000 order part number • Supports AlphaNumeric pager up
VISTA-128SIA to 8 different numbers using the
• Supports commercial UL wireless
VA8201
fire and burg • Two on-board notification (bell)
circuits delivering 2.3 amp * Connects to Northern Computers
• Stores up to 512 events and can
@ 12V or 3.4 amp @ 24V Passpoint Access Control Systems.
accommodate 150 user codes
Maximum 32 doors.
• Automatic smoke detector
• Supports addressable V-Plex
sensitivity maintenance testing ** When used with AlarmNet-i
access control points using
VistaKey (1 to 8 doors) • 4-wire smoke reset using on-
board J2 output trigger
• Supports up to 16 doors of
access control using Vista • Supports Dynamic Signaling for
Gateway Module (VGM)* LRR
VISTA-128FBP/V128FBP-24
Commercial Fire and Partitioned Burglary Alarm Control Panel
Additional Features – Supports 120 two-wire zones – Supports UL864/NFPA
• Notification Appliance Circuits points approved wireless smoke
(two): – Global polling technology for detectors
– Programmable faster processing
– Increased current draw capacity • Access Control integration
– Temporal code compliant – Full integration with PassPoint
– Individually silenceable (128mA)
– Supervised by panel Access Control System
• Programmable on-board auxiliary – Individually assignable to Complete Gateway interface of
relay partitions, notification circuit Vista and access functions
• SIA false alarm reduction features: (bell) output or aux relay • Up to 8 doors using VistaKey
– Exit error logic – 4,000 ft capability without the V-Plex Access Control
– Exit delay reset use of shielded cable
– Extender/Isolation bus module • Event reporting
– Cross zoning
– Call waiting defeat – Two-wire smoke detector • Local printer of access or VISTA
– Recent close report zone/group expansion module related event
adds two or four zones
• Supports commercial hardwired, – Eight zone – Class A and B • Scheduled uploading of events to
addressable V-Plex polling loop extender module central station
and wireless zones – Eight zone – Class B extender • Stored events for one call retrieval
module
• Hardwired zones
– One zone supervised contact • Communication
– Provides eight style B hardwired
monitor module – Phone mapping by zone
zones
response type
– EOLR supervised for Fire and • UL Listed wireless expansion – Supports VIP interactive phone
UL burglary installations – Supports up to 128 wireless voice module
– Supports N.O or N.C. sensors zones/points using 5881ENHC – Panel operation during
– Individually assignable to any receiver download
eight partition – Supervised by control for – Uploading equipment list to
– Up to 32 two-wire smoke check-in signals central station
detectors each on zone one and – Tamper protection for – Communication to PassPoint via
two (64 total) transmitters Vista Gateway Module
– Up to 50 two-wire glass break – Individually assignable up to
detectors on zone eight eight partitions • CCTV integration
– Supports VistaView-100 ECP
• Patented addressable V-Plex
based CCTV switchers
polling loop technology

4208U 4193SN
5192 Eight-Zone Serial Interface 5192 4208SNF
Series Smoke Expansion Module Series Smoke Eight-Zone
Detectors Module V-PLEX Detectors Expansion
Loop Module
5881 With 2 Class A
Wireless Zones
Receiver

6160CR
Red Alpha
Console VistaView-100
CCTV
Switcher

VistaKey V-Plex
Access Control
Module

Notification Appliances
Vista-128FBP 4204 NAC (Bell)
Relay Circuit 4204CF
Module

Eight Class B Hardware Zones

416 5140 LED


Parallel Printer Key Communicator
Switch Status Module
Option

Serial Printer
4100SM
Printer
Interface
Module

RS232
Notification Appliances
6220S Printer

Alpha Paging Phone Line to Central Station


Module

7720ULF Long
Range Radio 7835CF Cellular
Radio
Applications • Alarm power: 12VDC, 1.7A max Cabinet dimensions
The VISTA-128FBP control is well for each notification (bell) circuit • 18”H X 14.5”W X 4.3”D
suited for a variety of applications output Total 2.3amps @ 12V
as an integrated fire and burglary Environmental
• Aux. standby pwr: 12VDC, 1A • Storage temp: -10°C to 70°C
control. A diverse line of ADEMCO max
initiating devices supports this • Operating temp: 0°C to 50°C
extremely powerful control. Some of • Total power: 2.3A at 12VDC, 3.4A
the applications supported are: at 24VDC from all sources • Humidity: 85% RH
medical and professional buildings,
• Standby time: 24 hours with 1A • EMI: Meets or exceeds the
churches or synagogues, office
standby load using 34.4AH following requirements:
buildings, schools, strip malls,
battery – FCC Part 15, Class B Device
larger residences and factory or
– FCC Part 68
warehouse environments. • Fusing: Battery input, aux. and – IEC EMC Directive
notification (bell) circuit outputs
Installation
are protected using PTC circuit Agency Listings Burglary
The VISTA-128FBP alarm system protectors. All outputs are power • UL609 Grade A Local Mercantile
has been designed to mount both limited. Premises and Mercantile Safe and
quickly and easily. It meets all
• Optional 24-volt power supply, PS Vault
applicable requirements for UL
commercial fire and burglary 24 Supplies two 24 VFW, 1.7A full • UL611/1610 Grades A, AA,
installations. wave rectified, unfiltered Central Station
outputsMain Dialer:
Specifications Electrical • UL365 Grades A, AA Police
• Primary power: 18VAC @ 72VA • Line seize: Double Pole Connect
ADEMCO No. 1451
• Ringer equiv.: 0.7B Fire
• Control panel quiescent current • UL864/NFPA72 Local, Central
• Formats: ADEMCO Low Speed,
draw: 350mA Station and Remote Station
ADEMCO 4+2 Express, ADEMCO
• Backup battery: High Speed, ADEMCO Contact • Factory Mutual
– 12VDC, 12AH min to 34.4AH ID, Sescoa and Radionics
max • California State Fire Marshal
• Dual phone line capability (using
– Lead acid battery (gel type) • MEA
5140DLM module)
• UL985

Manual Pull Stations


5140MPS - 1*
5140MPS - 2*

4190SN
4193SN V-Plex Two-Zone
Serial Interface Expander 4293SN 4944SN
Module V-Plex Adapter Tamper Switch*
Addressable
Recessed Mount Flow Switch*
5881 Contact
Wireless Receiver Low Temp Switch*
ECP Bus (Max Two)

4297
Isolation/
5808LST Extender Module
6139R Smoke
32 Character Detectors 5890
Red-Alpha Wireless PIR
Keypad
4209U
Group Zoning
Module
4204CF
Supervised 5816
NAC Door/Window 5808LST
Module Miniature Smoke 4190SN
Transmitter Detectors Supports Up To 16 V-Plex
Conventional 2-Wire Two-Zone
Symphony Notification Smoke Detectors expander
Appliance

PassPoint

VGM (PTVGM)
Vista
Gateway
Supports Up To 64 Module
Conventional 2-Wire
Smoke Detectors

Vista-128FBP Vista-128FBP

Panel Linking Panel Linking


Module Module
VISTA-128FBP/V128FBP-24
Commercial Fire and Partitioned Burglary Alarm Control Panel
Additional Features – Supports 120 two-wire zones – Supports UL864/NFPA Applications • Alarm power: 12VDC, 1.7A max Cabinet dimensions
• Notification Appliance Circuits points approved wireless smoke The VISTA-128FBP control is well for each notification (bell) circuit • 18”H X 14.5”W X 4.3”D
(two): – Global polling technology for detectors suited for a variety of applications output Total 2.3amps @ 12V
– Programmable faster processing as an integrated fire and burglary Environmental
– Increased current draw capacity • Access Control integration • Aux. standby pwr: 12VDC, 1A • Storage temp: -10°C to 70°C
– Temporal code compliant – Full integration with PassPoint control. A diverse line of ADEMCO max
– Individually silenceable (128mA) initiating devices supports this
– Supervised by panel Access Control System • Operating temp: 0°C to 50°C
Complete Gateway interface of extremely powerful control. Some of • Total power: 2.3A at 12VDC, 3.4A
• Programmable on-board auxiliary – Individually assignable to at 24VDC from all sources • Humidity: 85% RH
Vista and access functions the applications supported are:
relay partitions, notification circuit medical and professional buildings,
(bell) output or aux relay • Up to 8 doors using VistaKey • Standby time: 24 hours with 1A • EMI: Meets or exceeds the
• SIA false alarm reduction features: churches or synagogues, office
– 4,000 ft capability without the V-Plex Access Control standby load using 34.4AH following requirements:
– Exit error logic buildings, schools, strip malls,
use of shielded cable battery – FCC Part 15, Class B Device
– Exit delay reset larger residences and factory or
– Extender/Isolation bus module • Event reporting – FCC Part 68
– Cross zoning warehouse environments. • Fusing: Battery input, aux. and
– Two-wire smoke detector – IEC EMC Directive
– Call waiting defeat • Local printer of access or VISTA notification (bell) circuit outputs
zone/group expansion module Installation
– Recent close report related event are protected using PTC circuit Agency Listings Burglary
adds two or four zones The VISTA-128FBP alarm system protectors. All outputs are power
• Supports commercial hardwired, • Scheduled uploading of events to • UL609 Grade A Local Mercantile
– Eight zone – Class A and B has been designed to mount both limited.
addressable V-Plex polling loop central station Premises and Mercantile Safe and
extender module quickly and easily. It meets all
and wireless zones • Optional 24-volt power supply, PS Vault
– Eight zone – Class B extender • Stored events for one call retrieval applicable requirements for UL
module commercial fire and burglary 24 Supplies two 24 VFW, 1.7A full • UL611/1610 Grades A, AA,
• Hardwired zones wave rectified, unfiltered
– One zone supervised contact • Communication installations. Central Station
– Provides eight style B hardwired outputsMain Dialer:
monitor module – Phone mapping by zone
zones Specifications Electrical • UL365 Grades A, AA Police
response type
– EOLR supervised for Fire and • UL Listed wireless expansion • Primary power: 18VAC @ 72VA • Line seize: Double Pole Connect
– Supports VIP interactive phone
UL burglary installations – Supports up to 128 wireless ADEMCO No. 1451
voice module • Ringer equiv.: 0.7B Fire
– Supports N.O or N.C. sensors zones/points using 5881ENHC – Panel operation during • Control panel quiescent current • UL864/NFPA72 Local, Central
– Individually assignable to any receiver • Formats: ADEMCO Low Speed,
download draw: 350mA Station and Remote Station
eight partition – Supervised by control for ADEMCO 4+2 Express, ADEMCO
– Uploading equipment list to
– Up to 32 two-wire smoke check-in signals • Backup battery: High Speed, ADEMCO Contact
central station • Factory Mutual
detectors each on zone one and – Tamper protection for – 12VDC, 12AH min to 34.4AH ID, Sescoa and Radionics
– Communication to PassPoint via
two (64 total) transmitters max • California State Fire Marshal
Vista Gateway Module • Dual phone line capability (using
– Up to 50 two-wire glass break – Individually assignable up to – Lead acid battery (gel type)
detectors on zone eight 5140DLM module) • MEA
eight partitions • CCTV integration
– Supports VistaView-100 ECP • UL985
• Patented addressable V-Plex
based CCTV switchers
polling loop technology
Manual Pull Stations
5140MPS - 1*
5140MPS - 2*

4208U 4193SN 4190SN


5192 Eight-Zone Serial Interface 5192 4208SNF 4193SN V-Plex Two-Zone
Series Smoke Expansion Module Series Smoke Eight-Zone Serial Interface Expander 4293SN 4944SN
Detectors Module V-PLEX Detectors Expansion Module V-Plex Adapter Tamper Switch*
Addressable
Loop Module Recessed Mount Flow Switch*
5881 With 2 Class A 5881 Contact
Wireless Zones Wireless Receiver Low Temp Switch*
Receiver ECP Bus (Max Two)

6160CR
Red Alpha 4297
Console VistaView-100 Isolation/
CCTV 5808LST Extender Module
Switcher 6139R Smoke
32 Character Detectors 5890
VistaKey V-Plex Red-Alpha Wireless PIR
Access Control Keypad
Module 4209U
Group Zoning
Module
4204CF
Notification Appliances
Vista-128FBP 4204 NAC (Bell) Supervised 5816
Relay Circuit 4204CF NAC Door/Window 5808LST
Module Module Miniature Smoke 4190SN
Transmitter Detectors Supports Up To 16 V-Plex
Conventional 2-Wire Two-Zone
Symphony Notification Smoke Detectors expander
Eight Class B Hardware Zones Appliance

416 5140 LED


Parallel Printer Key Communicator
Switch Status Module
Option
PassPoint

Serial Printer
VGM (PTVGM)
4100SM Vista
Printer Gateway
Interface Module
Module Supports Up To 64
Conventional 2-Wire
RS232 Smoke Detectors
Notification Appliances
6220S Printer

Alpha Paging Phone Line to Central Station


Module Vista-128FBP Vista-128FBP

7720ULF Long
Range Radio 7835CF Cellular
Radio Panel Linking Panel Linking
Module Module
VISTA-128FBP/V128FBP-24
Commercial Fire and Partitioned Burglary Alarm Control Panel

S P E C I F I C AT I O N S
Auxiliary Devices • 4190SN Remote Point Module sports watch combined
• 6160CR – Red Alpha Keypad – two zones • 5816 – Door/Window Transmitter
• 6139R – Red Alpha • 4193SN Two Zone Serial Interface • 5804 – Wireless key
Keypad/Annunciator Module • 5827BD – Bi-directional Keypad
• FSA-8 & FSA-24 annunciator • 4293SN One Zone Serial Interface • 5890 – PIR
modules Module • 5849 – Glassbreak Detector
• 4204 – Relay Module, four form C • 4297 Isolation/Extender Module • 5819 – Shock Sensor
contacts V-Plex (addressable) Smoke Commercial Wireless Devices
• 4204CF – Two supervised output Detectors: • 5808LST – Wireless Smoke
circuits
• 5192SD • 4192SD • 4192CP Detector
• 5881 Series – RF receiver
• 5192SDT • 4192SDT • 4192CPM • 5809 – Wireless Heat Detector
supporting 5800 wireless
• 4192SDTM • 5817CB – Wireless Commercial
detectors
Transmitter
• 6220S – System printer used with V-Plex Passive Infrared Detectors
• 5869 – Hold-Up Transmitter
4100SM serial module • 998MX • 5881ENHC – Commercial
Two-wire smoke detectors • 4275EX-SN Fire/Burg Receiver
conventional • 4278EX-SN
Access Control
• 2100 Series Photoelectric V-Plex (addressable) Contacts
• VistaKey V-Plex (addressable)
• 2400 Series Photoelectric • 4939SN-WH Access Control
• 1100 Series Ionization • 4944SN-WH • VistaKey-SK Starter Kit
Four-wire smoke detectors • 4959SN • VistaKey-EX Expansion Kit
conventional V-Plex Glassbreak Detectors: • VGM Vista Gateway Module to
• 2112/24 Series Photoelectric • 9500SN PassPoint Access Control
• 1412 Series Ionization (Northern Computers)
VISTA interactive phone module
Horn/Strobes CCTV
• 4286 Voice Module
• System Sensor Notification – VistaView-100 CCTV Switcher or
Appliances Optional 24V Power Supply Module
• PS24 – 24V power supply – 3.4A
Manual Pull Stations Internet Access
Long Range Radio:
• 5140MPS-1 • Long Range Radio 7720ULF-XX, • Graphical user interface with
• 5140MPS-2 7835C, 7835CF, 7845C internet capability
• Internet Remote Control-
V-Plex (addressable) Devices Upgraded software Networking Module
• 4208U Loop Expansion Module • Upgraded Compass Downloader • Internet Alarm Communicator
– eight zones Windows compatible (7845i)
• 4101SN Single Relay/Zone
Module Wireless Devices Paging
• 4208SNF Class A/B Expander • 5804BDV – Bi-directional with • VA8201 AlphaNumeric Pager
Module voice
• 4209U Group Zoning Module • 5804BD – Bi-directional Key
– two/four zones • 5804Watch – Wireless Key &

ORDERING
VISTA-128FBP Commercial Fire and Partitioned Burglary Alarm Control Panel 12V Model
V128FBP-24 Commercial Fire and Partitioned Burglary Alarm Control Panel 24V Model

Honeywell Security & Custom Electronics


165 Eileen Way, Syosset, NY 11791
www.honeywell.com/security

Copyright ©2003 Honeywell International Inc. L/V128FBP/D 8/04

You might also like