You are on page 1of 2

VISTA-21iP

CONTROL PANEL

Honeywell’s high capacity, feature-rich VISTA-21iP lets you to and from the control panel. When used with an optional
deliver more value to your customers on each and every AlarmNet GSM that snaps right on the board, the VISTA-21iP
sale. The VISTA-21iP provides up to 48 zones of protection, can be installed in premises without TELCO lines – guaranteeing
an on-board IP connection, graphic keypad support and communication independent of any infrastructure. The panel’s
dual partitions. The VISTA-21iP gives you the ability to send installation advantages, innovative end-user benefits and
alarm signals and upload/download via an Internet Protocol robust system capacity make the value-priced VISTA-21iP
(IP), improving the speed at which information can be delivered an ideal choice for higher-end installations.

FEATURES
• Internet alarm reporting and • 16 output devices • Dynamic Signaling
uploading/downloading capability – Relays (Model 4204 Relay Modules, – Reduces redundant reporting to
via on-board AlarmNet Internet or 4229 Expansion Module), and/or the central station when multiple
Communicator X-10® devices (when used with a reporting methods are used;
• Supports four graphic 4300 Transformer) i.e. digital dialer and AlarmNet radio
touchscreen keypads • Four installer-configurable zone
types allows the installer to create Valuable End-User Features
• Wireless keys can be programmed
without using zones custom zone types by assigning • Viewable on system keypads:
all zone attributes – Exit countdown
• Eight on-board hardwired zones
standard (15 when Zone Doubling • Supports four-wire, and up to – Time and date display*
feature is used) 16 two-wire smokes – Event log*
– 40 hardwired expansion zones – Works with Sentrol CleanMe™ • Auto keypad backlighting on entry
– 40 wireless expansion zones maintenance signal
• Keyswitch arming
• Two low current on-board • Multiple actions on output devices
• Programmable macro buttons and
trigger outputs depending on system state
single-button arming
– Turns lights off when system arms
• 100 Event Log viewable at system • Supports a variety of wireless remote
– Turns the same light on
keypads with time/date stamp controls for single-button operation
when system disarms
• 48 system user codes assignable – Flashes same lights when system • User Scheduling
to either partition is in alarm – Automatically activates X-10 and
• Expandable to 48 total zones when • Built-in phone line cut monitor relays at programmed times
used with hardwired and/or wireless with programmable delay and – Latchkey reports to pagers
expansion modules annunciation options – Auto arm/disarm
• Two independent partitions plus a – Display on system keypads – “User access” time windows
common partition – Trigger local sounders • Supports up to four end-user
– Global arming from any – Trigger system bell numeric pagers
system keypad • VIP Module allows system control
– Goto function to view or operate Security Dealer Features from any touchtone phone
one partition from the other
• Automatic System Load Shed • Chime by zone
– Separate partition account numbers
– During extended AC power fail,
the system battery will be
disconnected to prevent irreversible *Requires custom alpha keypad
battery failure. Reduces service
calls to replace batteries.
VISTA-21iP
CONTROL PANEL

SPECIFICATIONS
Electrical • 5881ENL RF Receiver supports – Standard for Safety for Digital Alarm
• Aux. power 12VDC, 600mA maximum up to eight zones – 60mA Communicator System Units –
• 5881ENM supports up to ANSI/UL 1635, 1996 (3rd edition)
• Seven hour standby at 400mA aux.
load with four amp hour battery 16 zones – 50mA – Safety of Household Burglar Alarm
• 5881ENH up to 48 zones – 50mA System Units, ANSI/UL 1023, issued
• 16.5VAC/40VA transformer 1996/11/25 (6th edition) with revisions
• Alarm output 12VDC, 2.0 amps max. • 5883H High Security Transceiver up to 12/30/04
– For agency listed installations, Module supports up to 48 zones –
80mA • Commercial Burglary:
combined aux. and alarm output
cannot exceed 700mA • Supports Eagle 1225 and 1221 boards – Standard for Safety for Police Station
Connected Burglar Alarm Units and
Output Control Keypads Systems – ANSI/UL 365 (4th edition),
issued 1997/01/31 with revisions up
• Supports up to four relay boards • 6160 Custom Alpha
to 2005/03/08
(up to 16 relays) (required for programming)
– 100mA – Standard for Safety Local Burglar
• Optional X-10 transformer/interface
Alarm Units and Systems – UL 609
(part no. 4300) may be used to control • 6160V Custom Alpha Voice
(11th edition), issued1996/08/28 with
up to 16 X-10 receiving devices – 100mA
revisions up to 2005/03/17
• 6150 Fixed English LCD
Zones – Standard for Safety Central Station
– 85mA/40mA
• Eight hardwired zones Burglar Alarm Units – ANSI/UL 1610
• 6150V Fixed English Voice LCD (3rd edition), issued 1998/10/26 with
(15 with zone doubling) – 85mA/40mA revisions up to 2005/08/16
• Selectable response 10msec, • 6150RF Fixed English RF LCD
350msec, 750msec – 85mA/40mA Communications
• Assignable to any partition • 6148 Fixed English LCD • VISTA-GSM Snap-in Dual-Path Digital
• 20 selectable zone types plus four – 70mA/30mA Wireless Communicator (IP required
configurable zone types for activation and registration)
• 6270 Graphic Touchscreen
• Programmable swinger suppression User Interface • Touchtone or pulse standard TELCO
dialers
• 6271C Color Graphic Touchscreen
Expansion Devices • Formats supported
User Interface
• 4219 – Eight hardwired zones – 16mA – ADEMCO Contact ID
• 6271CV Color Graphic Touchscreen
• 4204 – Up to four relays – 15mA – ADEMCO 4 + 2 Express
User Interface with Voice
standby (each active relay – ADEMCO low speed
• 8132 Symphony Advanced User – Sescoa/Radionics
draws an additional 40mA)
Interface
• 4229 – Eight hardwired zones and two • 3 + 1, 4 + 1 and 4 + 2 reporting
relays – 36mA (each active relay Agency Listings • Reporting capabilities
draws an additional 40mA) ETL listing – Split
– Dual
Accessories • Residential Fire and Burglary: – Split/Dual – True dial tone detection
• VISTA-GSM Snap-in Dual-Path Digital – Household Fire Warning System • Low battery reports 11.2 – 11.6VDC
Wireless Communicator (IP required Units – ANSI/UL 985, 2000/05/26
(5th edition) with revisions up to • AC loss and restoral reporting supported
for activation and registration)
2004/04/29
• 4286 VIP Voice Module – 220mA

ORDERING
VISTA-21iP Control Panel
VISTA-21iPSIA Control Panel for SIA Installations
VISTA-GSM Optional Snap-in Radio Module
VISTA-ULKT Cabinet for Listed Commercial Burglary Applications

Honeywell Security & Communications


Honeywell
2 Corporate Center Dr. Suite 100
P.O. Box 9040
Melville, NY 11747 L/VS21iPD/D
August 2008
www.honeywell.com © 2008 Honeywell International Inc.

You might also like