You are on page 1of 2

VISTA-10P

CONTROL PANEL

Honeywell’s feature-rich VISTA-10P is the industry’s most economical and versatile control panel. It’s ideally suited for a wide
range of applications. The six-zone panel significantly reduces dealer training and service call costs thanks to user-friendly
features that make operation easier than ever. In addition, it increases upsell opportunities through its expansion capabilities
and flexibility.

FEATURES

• Six hardwired zones on board Valuable End-User Features • 4286 Phone Module allows system
control from any touchtone phone
• 16 wireless expansion zones totaling • Flexible function keys allow
22 protection zones single button arming • Four output devices with multiple
actions per device
• Eight independent keyfob zones allow • One programmable macro key
– Turn lights on when system disarms
two wireless keys to be programmed
• Viewable on system keypad display with a 4204 Relay
without using any of the 22 zones
– Exit countdown – Flash same lights when system is in
• 32 Event log – Time and date* alarm using a 4204 Relay
– Event log*
• 16 user codes
• Two schedules
• One configurable zone type allows
– Can activate relays on programmed
installers to create their own custom
times or on events
zone type
– Latchkey reports to a pager
• Two on-board triggers – “User Access” time windows
• Four output devices using a • Chime by zone
4204 relay module * with Alpha Keypad
VISTA-10P
CONTROL PANEL

SPECIFICATIONS
Electrical Accessories Smoke Detectors

• Aux power 12VDC, 600mA max • 4286 VIP Voice Module – 220mA • Supports four-wire smoke detectors

• Seven hour standby at 400 mA aux • 5881ENL supports up to eight zones Communications
load with four amp hour battery – 60mA, 5881ENM supports up to
• Touchtone or pulse
16 zones – 50mA, 5883 Transceiver
• 16.5VAC/25VA transformer
supports up to 16 zones – 80mA • Formats supported
• Alarm output 12VDC, 2.0 amps max — ADEMCO Contact ID
• Supports Eagle 1225 and
— ADEMCO 4 + 2 Express
• For UL installations, combined 1221 boards
— ADEMCO low speed
aux and alarm output cannot
Keypads — Sescoa/Radionics
exceed 700mA
• 6160 Custom Alpha (required • 3 + 1, 4 + 1 and 4 + 2 reporting
Output Control
for programming) – 100mA
• Reporting capabilities
• Supports multiple output devices,
• 6160V Custom Alpha Voice – 100mA — Split
one 4204 and two triggers
— Dual
• 6150 Fixed English LCD
Zones — Split/Dual - True dial tone detection
– 85mA/40mA
• Six hardwired zones • Low battery reports 11.2 – 11.6VDC
• 6150V Fixed English Voice LCD
• Selectable response: 10msec, – 85mA/40mA • AC loss and restoral
350msec, 750msec reporting supported
• 6150RF Fixed English RF LCD
• 16 selectable zone types plus – 85mA/40mA
one configurable zone type
• 6148 Fixed English LCD
• Programmable swinger suppression – 70mA/30mA
Expansion Devices Agency Listings
• 4204 – Up to four relays – 15mA • UL Residential Fire, Burglary
standby (each active relay draws and CSFM
an additional 40mA)

ORDERING
VISTA-10P VISTA10P Control Panel

Honeywell Security & Custom Electronics


Honeywell International Inc.
PO Box 9035 RE06040
Syosset, NY 11791 L/VISTA10P/D
August 2006
www.honeywell.com © 2006 Honeywell International Inc.