PCS-9691E Overcurrent Relay

Feeder Protection
The PCS­9691E overcurrent relay is designed for fast and selective
protection, control and monitoring of feeders, shunt capacitor banks,
reactors or motors etc. in directly grounded, impedance grounded,
Peterson coil grounded or ungrounded system.

Categories

Protection, Automation & Control

- Protection & Control

· Transmission Line Protection


· Busbar Protection

· Transformer Protection

· Reactor Protection
Send Inquiry Now
· Circuit Breaker Protection
· Generator Protection

Functions Features Download · Feeder Protection

· Motor Protection

Protection Operation time supervision of breaker · Capacitor Protection

· Arc Protection
Three­stage phase overcurrent protection. 256 SOE records, including tripping, alarm,
· Transfer & Synchronization
(50/51P) change of binary inputs and self­check.
- Automation
Three­stage neutral overcurrent protection. Eight (8) wave records, up to 4.5 seconds for each
- Digital Substation
(50/51G) wave record, compatible with COMTRADE format.
- Energy Management
Three­stage negative sequence overcurrent Supervision of tripping time, CBF starting current,
- Power Stability Control
protection. (51Q) CB switching counter, CB travelling time and
- Measurement
internal relay fault.
Directional ground time overcurrent protection. - Recording
(67G)
- Accessories
Breaker failure protection. (51BF) Control - Software Kit

Thermal overload protection. (49) 10 configurable binary inputs
HVDC & FACTS
Broken conductor protection. (46BC) 7 binary outputs for DC voltage (including 4
Renewable & BESS
configurable contacts), 9 binary outputs for AC
Undervoltage/overvoltage protection. (27/59)
voltage (including 6 configurable contacts)
Multi­slot three­pole auto­reclosing (Up to 3 slots). Related Links
8 LEDs, including 5 configurable LEDs
(79)
Thermal Power Plant
Local/remote opening/closing logic of breaker
Ten (10) available curves complied with ANSI and
IEC standard. (IDMT) Metals and Mining
Faceplate buttons for local control of breaker

Thermal model overload curve. Oil and Petrochemical

Voltage transformer supervision. (VTS) Electrified Railway


Communication and HMI
Current transformer supervision. (CTS) Underground Subway
One RS­232 port for testing
Current drift auto­adjustment. AC Distribution
Two RS­485 ports for communication with SCADA

IEC 60870­5­103 DNP 3.0 serial, and MODBUS Hydro Power Plant

Metering and Monitoring protocol
Nuclear Power Plant
RCS­PC assistant software for testing
Tripping/Closing circuit supervision Pumped Storage Power Plant
Clock Synchronization
Circuit breaker state monitoring Solar/Wind Farms

PCS-9611 Feeder Relay


Who Are We What Are We Doing Whom Do We Serve Follow Us
·Our News ·Protection, Automation & Control ·Power Grids
·Our Culture ·FACTS & HVDC ·Power Plants    
·Contact Us ·Renewable Energy Generation ·Industrials
·Quality Control

Copyright NR Electric Co., Ltd. 2001­2016. All Rights Reserved.

You might also like