You are on page 1of 8

ACCU-LINK

BELARUS Qingdao HUNGARY U.S.A


Range Minsk Longshan town office, Budapest California
Kuzme Chornogo 31 -901 Nange backstreet Jimo city – West Gate Business Park 5660-5680 Rickenbacker Road Bell
Accu-Link belts are available in Z/3L, A/4L, B/5L and C sections. Accu-Link can work on standard pulleys for V-belts. 220100 Minsk Qingdao – Shandong, 266100 Topark u. 9 Los Angeles, CA 90201
Megadyne can supply open end Acculink in carton boxes or endless belts in light carton sleeves. Phone +375 17 2802486 Phone +86 532 8765 2117 2045 Torokbalint Phone +1 323 265 8061 Accu-Link is the Megadyne’s link belt, created and developed as
Info.ee@megadynegroup.com info.cn@megadynegroup.com Phone +36 23 428 628 inquiries@jasonindustrial.com an alternative to classical rubber V-belts. Megadyne’s Accu-Link
Z/3L A/4L B/5L C info.hu@megadynegroup.com combines superior strength and durability with quick and easy
BRASIL Shanghai Florida
Belt weight g/m (+/-1,5) 43,0 76,5 117,5 178,5 assembly and installation. The original concept is to give a fast
Sorocaba Business Office A area, MEXICO 5120-B East Adamo Drive Tampa,
Min pulley diameter (mm) 45 80 140 225 Avenida Dr. Armando Pannunzio 6th Floor, 11th Building, Mexico C.P. FL 33619 replacement to classical V-belts in case of break. Despite this, thanks
610 CEP 18050-000 No.1588, Li an Road Av. Ceylan 959 Int. 9 Y 10 Phone +1 813 241 4111 to the performance of link belts, today Accu-Link is used in a very wide
Service temperature range -25 °C / +80 °C (-13 °F / 176 °F) Sorocaba, São Paulo Shanghai, 201105 Industrial Vallejo Azcapotzalco, inquiries@jasonindustrial.com range of applications as original equipment.
Standard roll lengths (ft) 25-100 25-100 25-100 25-50 Phone +55 15 2101 7700 Phone +86 21 5447 1473 Mexico C.P. 02300
inquiries@jasonindustrial.com info.cn@megadynegroup.com Phone +52 55 5587 3680 Georgia Accu-Link is a link belt: it means it is made of several links assembled all
Standard sleeve lengths (ft) 5 5-6 6 5 inquiries@jasonindustrial.com Belt Corporation of America together. Thanks to this, belts can have every length just by modifying
CANADA Shenyang 253 Castleberry Industrial Dr. the number of links.
Edmonton Room303, Flat 3, No.131-9 POLAND Cumming, GA 30040
Measuring Assembling 10020 42nd Avenue Edmonton
Alberta T6E 5B4
Baogong South St.
Tiexi District
Bydgoszcz
Ołowiana 10, 85-461 Bydgoszcz
Phone +770 887-9725
inquiries@jasonindustrial.com
Links are made with a polyurethane polymer reinforced by a multilayer
woven polyester fabric. The design of the links and the state-of-art
Phone: +1 780 461 4400 Shenyang,110074 POLAND
manufacturing process allow superior performances and finishing
inquiries@jasonindustrial.com Phone +86 24 2572 3238 Phone +48 52 348 77 12 Illinois
Fax +86 24 2572 3238 info.pl@megadynegroup.com 221 South Westgate Drive
quality. Accu-Link is ground to get a smooth and precise side edge
Montreal info.cn@megadynegroup.com Carol Stream, IL 60188 and section, leading to a low vibrating belt and a smooth and silent
9135 Cote De Liesse SOUTH AFRICA Phone: +1630 752 0600 transmission.
Dorval, Quebec H9P 2N9 COLOMBIA Johannesburg inquiries@jasonindustrial.com
Phone: +1 514 31 2341 Cartagena Unit 4 - 6, 24 Park Avenue South The belt is delivered already assembled and pre-tensioned to reduce
inquiries@jasonindustrial.com Diag 22-56-112 - Highway Business Park - New Jersey Americas HQ the elongation especially during the early stage of its start-up.
Bario el Bosque Rooihuiskraal,Centurion 340 Kaplan Drive Fairfield
Toronto Cartagena, Colombia Phone +27 (0)12 661 1652 NJ 07004
1. Holding the belt with the 2. Flexing the belt as much as 3. Ensure that tab will
927 Matheson Boulevard East NIT 900-648-909-6 Fax +27 (0)12 661 1634 Phone +1 973 227 4904
1. Pull the belt tight around tabs upwards, let the tab of needed, twist and insert the stay transversally to the Mississauga, Ontario L4W 2R7 Phone: 011 57 313 501 5397 info.sa@megadynegroup.com inquiries@jasonindustrial.com
the sheaves to check the Phone: +1 905 602 4400 inquiries@jasonindustrial.com
one belt’s end get through second tab through the end link. belt’s running direction; inquiries@jasonindustrial.com SPAIN North Carolina
needed length, overlapping two links at once. reverse the belt upside
CHINA
CZECH REPUBLIC
Praha
Barcelona
Ctra de l’Arboc, Km 1,7
11016 Granite Street, Charlotte,
NC 28273 Main features and advantages:
the last two tabs .with two (three if C section) down to let it running on Beijing Karlovarska Business Park 08800 Vilanova I La Geltru Phone +1 704 583 5388
NO.37-344 Fudongyuan.Ciqu Street Na Hurce 1077/4 (Budova C), Barcelona inquiries@jasonindustrial.com • EASY TO ASSEMBLE
holes in matching.
Disassembling the tab side.
Taihu town, Tongzhou 161 00 – Phone +34 93 811 5450 Accu-Link can be assembled without any tool and in a matter of
2. Count the number of links Beijing 101111 Praha 6 – Ruzyne info.sp@megadynegroup.com Oregon seconds.
Phone +86 10 8150 7478 Phone +420 2 8481 7181 One SE Alder St., Portland,
and remove one link every info.cn@megadynegroup.com office.cz@megadynegroup.com SWEDEN OR 97214
• EASY TO INSTALL
24 for Z/3L, A/4L and B/5L Kristianstad Phone +1 888 231 7224 Accu-Link can be adapted to every length; in case of difficult layout
Foshan FRANCE Estrids Väg 15 inquiries@jasonindustrial.com or when taking the drive apart would take too long. Acculink can be
sections, and one link every n.5 Hedang Industrial Area Paris 291 65 Kristianstad installed open and closed afterwards, in a very easy and fast way.
East Side Wu Gang Road Logistic Center Zi Les Bordes - 15 Phone +46 10 1309600 South Carolina
20 for C section to get the • SMALL INVENTORY

ACCU-LINK
Changcheng district, Foshan Rue Gustave Madiot info.se@megadynegroup.com 101 Pelham Davis Cir, Greenville,
proper installation tension. Guangdong 528031 91923 Bondoufle Cedex SC 29615-5752 With one roll of Accu-Link it is possible to get any length of classical
Phone +86 757 83815530 Phone +33 1 6079 8200 THAILAND Phone +1 864 288 9916 V-belts; with one roll per section, inventories will be much smaller,
3. For multiple belt drives, 1. Put the belt with the tabs 2. Twist one tab 90° to 3. Rotating the belt by 90° info.cn@megadynegroup.com info.fr@megadynegroup.com Bangkok inquiries@jasonindustrial.com easier and cheaper to manage.
upwards and bend it as much as make it parallel to the you can now easily pull one S.S.P. Tower – 16th Floor –
be ensure that each belt has Fujiang St. Jean De Maurienne Office 10 Soi Sukhumvit 63 Texas • HIGH POWER RATE
possible. belt; in this way you can belt’s end away from the No.720 Marketing Comprehesive le prè de la Garde -Av. Italie- (Ekamai) Klong Tan Nuea, 8510 Ambassador Row, Dallas Accu-Link has power ratings similar to classical V-belts.
the same number of links.
pull the end of the link other one. Building, South Lingshui Street 73300 S. Jean de Maurienne Vadhana Bangkok 10110 TX 75247
Wuli Industrial Park, Phone +33 4 7964 0613 Phone: +66 (0) 27115477 Phone +1 972 438 6992 • HIGH RESISTANCE TO ENVIRONMENT
over the tab. Jinjang City, Fujian, 362261 info.fr@megadynegroup.com info.apac@megadynegroup.com inquiries@jasonindustrial.com Thanks to its state-of-the-art materials, Accu-Link can withstand to
NOTE: Unlike conventional V-Belts, Accu-Link can be rolled onto pulleys - no cord to break. Phone +86 595 8816 0309 salt, chemicals, mineral pure oils and greases. This increases the
info.cn@megadynegroup.com GERMANY TURKEY life time compared to standard rubber V-belts.
Borchen Izmir
Installation Ningbo
Industrial Chemical Area,
Nikolaus Otto Straße 24
33178 Borchen
Mustafa Kemal Ataturk Mahallesi
Izmir Ankara Asfalti Caddesi
• HIGH TEMPERATURE RESISTANCE
Accu-Link can operate un a wide range of temperature:
1. Be sure that the belt has the tabs on the inner side: the belt has to run with the tabs oppositely facing the running direction; Fengxiang Road 777, Xiepu Town Phone +49 5251 8735 0 No:19, 35170 Ulucak Kemalpasa -25 °C / +80 °C (-13 °F / 176 °F)
Zhenghai District, info.de@megadynegroup.com Phone +90 232 877 07 00
2. Fit the belt in the nearest groove of the smallest sheave and then roll the belt onto the larger sheave. For multiple belts drive, • HIGH RESISTACE TO HARSH ENVIRONMENT
Ningbo City , Zhejiang Province, info@rultrans.com.tr HEADQUARTERS
repeat the operation on all the grooves 315203 Elchingen Accu-Link is suited for harsh environment where it can last ever
3. Always make sure that belts look pretty tight and tabs are still in the correct position. Phone +86 574 8650 2886 Daimlerstraße 13 U.K. ITALY Torino longer than standard rubber V-belts.
info.cn@megadynegroup.com 89275 Elchingen Birmingham Via S. Lucia, 114
If it is easy to move the engine, you might install the belt in the following way: Phone +49 7308 9665 0 Unit 1, The Washington Centre, 10075 Mathi (Torino) • QUIET AND SMOOTH RUNNING
produktion@megadynegroup.com Halesowen Road, Netherton, Phone +39 011 926 8052 Thanks to the superior finishing, Accu-Link may run quieter and
1. Set the engine in mid position of its adjustment range and mark this position clearly; Dudley, West Midlands, DY2 9RE info@megadynegroup.com smoother than a V-belt.
2. Check the belt’s length as previously shown; Phone: +44 1384 215 021
sales@megadynegroup.com www.megadynegroup.com
3. Move the engine forward to reduce the center distance;
www.jasonindustrial.com
4. Install the belt as in “INSTALLATION” paragraph;
5. Pull the engine back to the previously marked position.
Edition: March 2015

Retensioning
As in any V-Belt drive, Acculink belts require to check for tension after 24 h of full load operating time. If the belt is not tight
enough, restore the tension by removing some link. Anyway, check the belt’s tension periodically and restore tension.
ACCU-LINK
BELARUS Qingdao HUNGARY U.S.A
Range Minsk Longshan town office, Budapest California
Kuzme Chornogo 31 -901 Nange backstreet Jimo city – West Gate Business Park 5660-5680 Rickenbacker Road Bell
Accu-Link belts are available in Z/3L, A/4L, B/5L and C sections. Accu-Link can work on standard pulleys for V-belts. 220100 Minsk Qingdao – Shandong, 266100 Topark u. 9 Los Angeles, CA 90201
Megadyne can supply open end Acculink in carton boxes or endless belts in light carton sleeves. Phone +375 17 2802486 Phone +86 532 8765 2117 2045 Torokbalint Phone +1 323 265 8061 Accu-Link is the Megadyne’s link belt, created and developed as
Info.ee@megadynegroup.com info.cn@megadynegroup.com Phone +36 23 428 628 inquiries@jasonindustrial.com an alternative to classical rubber V-belts. Megadyne’s Accu-Link
Z/3L A/4L B/5L C info.hu@megadynegroup.com combines superior strength and durability with quick and easy
BRASIL Shanghai Florida
Belt weight g/m (+/-1,5) 43,0 76,5 117,5 178,5 assembly and installation. The original concept is to give a fast
Sorocaba Business Office A area, MEXICO 5120-B East Adamo Drive Tampa,
Min pulley diameter (mm) 45 80 140 225 Avenida Dr. Armando Pannunzio 6th Floor, 11th Building, Mexico C.P. FL 33619 replacement to classical V-belts in case of break. Despite this, thanks
610 CEP 18050-000 No.1588, Li an Road Av. Ceylan 959 Int. 9 Y 10 Phone +1 813 241 4111 to the performance of link belts, today Accu-Link is used in a very wide
Service temperature range -25 °C / +80 °C (-13 °F / 176 °F) Sorocaba, São Paulo Shanghai, 201105 Industrial Vallejo Azcapotzalco, inquiries@jasonindustrial.com range of applications as original equipment.
Standard roll lengths (ft) 25-100 25-100 25-100 25-50 Phone +55 15 2101 7700 Phone +86 21 5447 1473 Mexico C.P. 02300
inquiries@jasonindustrial.com info.cn@megadynegroup.com Phone +52 55 5587 3680 Georgia Accu-Link is a link belt: it means it is made of several links assembled all
Standard sleeve lengths (ft) 5 5-6 6 5 inquiries@jasonindustrial.com Belt Corporation of America together. Thanks to this, belts can have every length just by modifying
CANADA Shenyang 253 Castleberry Industrial Dr. the number of links.
Edmonton Room303, Flat 3, No.131-9 POLAND Cumming, GA 30040
Measuring Assembling 10020 42nd Avenue Edmonton
Alberta T6E 5B4
Baogong South St.
Tiexi District
Bydgoszcz
Ołowiana 10, 85-461 Bydgoszcz
Phone +770 887-9725
inquiries@jasonindustrial.com
Links are made with a polyurethane polymer reinforced by a multilayer
woven polyester fabric. The design of the links and the state-of-art
Phone: +1 780 461 4400 Shenyang,110074 POLAND
manufacturing process allow superior performances and finishing
inquiries@jasonindustrial.com Phone +86 24 2572 3238 Phone +48 52 348 77 12 Illinois
Fax +86 24 2572 3238 info.pl@megadynegroup.com 221 South Westgate Drive
quality. Accu-Link is ground to get a smooth and precise side edge
Montreal info.cn@megadynegroup.com Carol Stream, IL 60188 and section, leading to a low vibrating belt and a smooth and silent
9135 Cote De Liesse SOUTH AFRICA Phone: +1630 752 0600 transmission.
Dorval, Quebec H9P 2N9 COLOMBIA Johannesburg inquiries@jasonindustrial.com
Phone: +1 514 31 2341 Cartagena Unit 4 - 6, 24 Park Avenue South The belt is delivered already assembled and pre-tensioned to reduce
inquiries@jasonindustrial.com Diag 22-56-112 - Highway Business Park - New Jersey Americas HQ the elongation especially during the early stage of its start-up.
Bario el Bosque Rooihuiskraal,Centurion 340 Kaplan Drive Fairfield
Toronto Cartagena, Colombia Phone +27 (0)12 661 1652 NJ 07004
1. Holding the belt with the 2. Flexing the belt as much as 3. Ensure that tab will
927 Matheson Boulevard East NIT 900-648-909-6 Fax +27 (0)12 661 1634 Phone +1 973 227 4904
1. Pull the belt tight around tabs upwards, let the tab of needed, twist and insert the stay transversally to the Mississauga, Ontario L4W 2R7 Phone: 011 57 313 501 5397 info.sa@megadynegroup.com inquiries@jasonindustrial.com
the sheaves to check the Phone: +1 905 602 4400 inquiries@jasonindustrial.com
one belt’s end get through second tab through the end link. belt’s running direction; inquiries@jasonindustrial.com SPAIN North Carolina
needed length, overlapping two links at once. reverse the belt upside
CHINA
CZECH REPUBLIC
Praha
Barcelona
Ctra de l’Arboc, Km 1,7
11016 Granite Street, Charlotte,
NC 28273 Main features and advantages:
the last two tabs .with two (three if C section) down to let it running on Beijing Karlovarska Business Park 08800 Vilanova I La Geltru Phone +1 704 583 5388
NO.37-344 Fudongyuan.Ciqu Street Na Hurce 1077/4 (Budova C), Barcelona inquiries@jasonindustrial.com • EASY TO ASSEMBLE
holes in matching.
Disassembling the tab side.
Taihu town, Tongzhou 161 00 – Phone +34 93 811 5450 Accu-Link can be assembled without any tool and in a matter of
2. Count the number of links Beijing 101111 Praha 6 – Ruzyne info.sp@megadynegroup.com Oregon seconds.
Phone +86 10 8150 7478 Phone +420 2 8481 7181 One SE Alder St., Portland,
and remove one link every info.cn@megadynegroup.com office.cz@megadynegroup.com SWEDEN OR 97214
• EASY TO INSTALL
24 for Z/3L, A/4L and B/5L Kristianstad Phone +1 888 231 7224 Accu-Link can be adapted to every length; in case of difficult layout
Foshan FRANCE Estrids Väg 15 inquiries@jasonindustrial.com or when taking the drive apart would take too long. Acculink can be
sections, and one link every n.5 Hedang Industrial Area Paris 291 65 Kristianstad installed open and closed afterwards, in a very easy and fast way.
East Side Wu Gang Road Logistic Center Zi Les Bordes - 15 Phone +46 10 1309600 South Carolina
20 for C section to get the • SMALL INVENTORY

ACCU-LINK
Changcheng district, Foshan Rue Gustave Madiot info.se@megadynegroup.com 101 Pelham Davis Cir, Greenville,
proper installation tension. Guangdong 528031 91923 Bondoufle Cedex SC 29615-5752 With one roll of Accu-Link it is possible to get any length of classical
Phone +86 757 83815530 Phone +33 1 6079 8200 THAILAND Phone +1 864 288 9916 V-belts; with one roll per section, inventories will be much smaller,
3. For multiple belt drives, 1. Put the belt with the tabs 2. Twist one tab 90° to 3. Rotating the belt by 90° info.cn@megadynegroup.com info.fr@megadynegroup.com Bangkok inquiries@jasonindustrial.com easier and cheaper to manage.
upwards and bend it as much as make it parallel to the you can now easily pull one S.S.P. Tower – 16th Floor –
be ensure that each belt has Fujiang St. Jean De Maurienne Office 10 Soi Sukhumvit 63 Texas • HIGH POWER RATE
possible. belt; in this way you can belt’s end away from the No.720 Marketing Comprehesive le prè de la Garde -Av. Italie- (Ekamai) Klong Tan Nuea, 8510 Ambassador Row, Dallas Accu-Link has power ratings similar to classical V-belts.
the same number of links.
pull the end of the link other one. Building, South Lingshui Street 73300 S. Jean de Maurienne Vadhana Bangkok 10110 TX 75247
Wuli Industrial Park, Phone +33 4 7964 0613 Phone: +66 (0) 27115477 Phone +1 972 438 6992 • HIGH RESISTANCE TO ENVIRONMENT
over the tab. Jinjang City, Fujian, 362261 info.fr@megadynegroup.com info.apac@megadynegroup.com inquiries@jasonindustrial.com Thanks to its state-of-the-art materials, Accu-Link can withstand to
NOTE: Unlike conventional V-Belts, Accu-Link can be rolled onto pulleys - no cord to break. Phone +86 595 8816 0309 salt, chemicals, mineral pure oils and greases. This increases the
info.cn@megadynegroup.com GERMANY TURKEY life time compared to standard rubber V-belts.
Borchen Izmir
Installation Ningbo
Industrial Chemical Area,
Nikolaus Otto Straße 24
33178 Borchen
Mustafa Kemal Ataturk Mahallesi
Izmir Ankara Asfalti Caddesi
• HIGH TEMPERATURE RESISTANCE
Accu-Link can operate un a wide range of temperature:
1. Be sure that the belt has the tabs on the inner side: the belt has to run with the tabs oppositely facing the running direction; Fengxiang Road 777, Xiepu Town Phone +49 5251 8735 0 No:19, 35170 Ulucak Kemalpasa -25 °C / +80 °C (-13 °F / 176 °F)
Zhenghai District, info.de@megadynegroup.com Phone +90 232 877 07 00
2. Fit the belt in the nearest groove of the smallest sheave and then roll the belt onto the larger sheave. For multiple belts drive, • HIGH RESISTACE TO HARSH ENVIRONMENT
Ningbo City , Zhejiang Province, info@rultrans.com.tr HEADQUARTERS
repeat the operation on all the grooves 315203 Elchingen Accu-Link is suited for harsh environment where it can last ever
3. Always make sure that belts look pretty tight and tabs are still in the correct position. Phone +86 574 8650 2886 Daimlerstraße 13 U.K. ITALY Torino longer than standard rubber V-belts.
info.cn@megadynegroup.com 89275 Elchingen Birmingham Via S. Lucia, 114
If it is easy to move the engine, you might install the belt in the following way: Phone +49 7308 9665 0 Unit 1, The Washington Centre, 10075 Mathi (Torino) • QUIET AND SMOOTH RUNNING
produktion@megadynegroup.com Halesowen Road, Netherton, Phone +39 011 926 8052 Thanks to the superior finishing, Accu-Link may run quieter and
1. Set the engine in mid position of its adjustment range and mark this position clearly; Dudley, West Midlands, DY2 9RE info@megadynegroup.com smoother than a V-belt.
2. Check the belt’s length as previously shown; Phone: +44 1384 215 021
sales@megadynegroup.com www.megadynegroup.com
3. Move the engine forward to reduce the center distance;
www.jasonindustrial.com
4. Install the belt as in “INSTALLATION” paragraph;
5. Pull the engine back to the previously marked position.
Edition: March 2015

Retensioning
As in any V-Belt drive, Acculink belts require to check for tension after 24 h of full load operating time. If the belt is not tight
enough, restore the tension by removing some link. Anyway, check the belt’s tension periodically and restore tension.
Technical calculation Table 3: service factor Fs Calculation example
DRIVES MACHINE DATA
Applications
TS (1) (2) P = 12 kW Thanks to their features, Accu-Link belts can be used in very wide range of applications. In the following table it is
AC electric motors: high slip, squirrel cage, synchronous AC electric motors: high torque, high slip, single phase, wound rotor, com- Speed: 1100 rpm possible to find a list of the main applications where Accu-Link are widely used with the advantages compared to
DC electric motors: parallel excitation mutator Drive sheave: 8”
Multi-cylinder internal combustion engines DC electric motors> series and compound excitation the classical rubber V-Belts.
Driven sheave: 12”
Gas or steam turbines Single-cylinder internal combustion engines with direct coupling or with
D d γO countershaft
Center distance: 38”

TS Steam engines APPLICATIONS MAIN ADVANTAGES


Daily operating hours Application: compressor
Applications Type of engine: 1 Higher resistance to salty and greasy environment
0-8 (1) 8-16 (1) 16-24 (1) 0-8 (2) 8-16 (2) 16-24 (2)
l Light use
Working hours: 8-16 per day Marine industry
Fs will be 1,2 Reduced inventory
Classical industrial drives up to 5 kW
1,0 1,1 1,2 1,1 1,2 1,3
SYMBOL UNIT DEFINITION SYMBOL Fans, pumps, compressors
Light conveyors CHOICE OF BELT SECTION Air handling Easier and quicker to install
Cg correction factor n2 (RPM) speed of bigger pulley (slower)
Normal use The corrected power Pc is
n1 (RPM) speed of smaller pulley (faster) P (kW) power to be transmitted Drives up to 15 kW Pc= P × Fs= 12 × 1,2 = 14,4 kW Metal and wood working machines Reduced noise, reduced vibration
d (mm) pitch diameter of smaller pulley Pc (kW) corrected power Fans, pumps, compressors, line shafts, machine tools, 1,1 1,2 1,3 1,2 1,3 1,4 Because of the high power, we can go for a C section, expecting more than one belt to be used.
D (mm) pitch diameter of bigger pulley Pb (kW) basic performance of a single belt
punches, generators Poultry industry Enhanced resistance to harsh environment
Heavy conveyors DETERMINATION OF ACTUAL POWER RATING
I (mm) center distance Pa (kW) actual belt power Heavy use Agriculture Enhanced resistance to typical agri-environment
Arc of contact g
i transmission ratio Q number of belts Textile machines
g = 180 - (57 x [(D-d):l]) = 180 - (57 × [(12-8):38]) = 174°
saw mills, woodworking machines, 1,2 1,3 1,4 1,4 1,5 1,6 Easier and quicker to install
Ts (N) static belt tension v (m/s) peripheral belt speed This means that Cg is 0.98.
brick machines, piston compressors, Rolling conveyor
g (°) arc of contact Fs service factor paper mills, positive blowers The belt power rating Pa is
Pa= Pb× Cg = 8 × 0,98 = 7,84 kW Better performing in case of pulley misalignment

CHOICE OF BELT SECTION DETERMINATION OF NUMBER OF BELTS Glass industry No staining


where Pb comes from table 7.
To choose between the sections, to find out the corrected power (Pc ) it is first necessary to calculate: The number of belts comes from the following formula:
Pc= P × Fs Easier and quicker to install
Table 1: belt section selection DETERMINATION OF NUMBER OF BELTS
Q = Pc : Pa Tiles and marble conveyor
10000 The final number of belts is:
Enhanced resistance to harsh environment
Q = Pc: Pa = 14,4 : 7,84 = 1,84
The final number of belts is given by rounding up Q to the next higher integer number. This means that the actual number of needed belts is 2.
Rotational speed (1/min.)

1000
Trasmittable Power
Z/3L
A/4L Table 4 - Z/3L profile Table 5 - A/4L profile Table 6 - B/5L profile Table 7 - C profile
B/5L 1,10 4,50 9,00 16,00
C

100 1,00
4,00 8,00
14,00
0,90
3,50 7,00
12,00
0,80

3,00 6,00
0,70
10 10,00
0,1 1 10 100
2,50

HPower (kW)
5,00

Power (kW)
Power (kW)
0,60
Power (kW)

Power (kW) (Pc )


2'' pulley 2.6'' pulley 4.4'' pulley 8,00 7'' pulley
3'' pulley 5.2" pulley 8'' pulley
DETERMINATION OF ACTUAL POWER RATING 0,50
4" pulley
2,00 3.6'' pulley 4,00
4,6" pulley 6.8" pulley 10" pulley
The actual power rating Pa is given by the drive working conditions: 6,00
0,40
Pa = Pb × C g 1,50 3,00
where Pb is the power base of the belt and Cg is the arc of contact correction factor as per following table.
0,30
4,00
1,00 2,00
Table 2: arc of contact correction factor Cg 0,20
The arc of contact is calculated as follows: 2,00
0,50 1,00
g = 180- (57 x [(D-d):l]) 0,10

Arc of 0,00 0,00


180° 175° 170° 165° 160° 155° 150° 145° 140° 135° 130° 125° 120° 115° 110° 105° 100° 0,00 0,00
contact g 500 1500 2500 3500 4500 5500 600 1100 1600 2100 2600 3100 3600 4100 500 1000 1500 2000 2500 3000 3500 300 500 700 900 1100 1300 1500 1700 1900 2100 2300
Belt speed (RPM) Belt speed (RPM) Belt speed (RPM) Belt speed (RPM)
Cg 1,00 0,99 0,98 0,96 0,95 0,93 0,92 0,90 0,89 0,87 0,86 0,84 0,82 0,80 0,78 0,76 0,74
Technical calculation Table 3: service factor Fs Calculation example
DRIVES MACHINE DATA
Applications
TS (1) (2) P = 12 kW Thanks to their features, Accu-Link belts can be used in very wide range of applications. In the following table it is
AC electric motors: high slip, squirrel cage, synchronous AC electric motors: high torque, high slip, single phase, wound rotor, com- Speed: 1100 rpm possible to find a list of the main applications where Accu-Link are widely used with the advantages compared to
DC electric motors: parallel excitation mutator Drive sheave: 8”
Multi-cylinder internal combustion engines DC electric motors> series and compound excitation the classical rubber V-Belts.
Driven sheave: 12”
Gas or steam turbines Single-cylinder internal combustion engines with direct coupling or with
D d γO countershaft
Center distance: 38”

TS Steam engines APPLICATIONS MAIN ADVANTAGES


Daily operating hours Application: compressor
Applications Type of engine: 1 Higher resistance to salty and greasy environment
0-8 (1) 8-16 (1) 16-24 (1) 0-8 (2) 8-16 (2) 16-24 (2)
l Light use
Working hours: 8-16 per day Marine industry
Fs will be 1,2 Reduced inventory
Classical industrial drives up to 5 kW
1,0 1,1 1,2 1,1 1,2 1,3
SYMBOL UNIT DEFINITION SYMBOL Fans, pumps, compressors
Light conveyors CHOICE OF BELT SECTION Air handling Easier and quicker to install
Cg correction factor n2 (RPM) speed of bigger pulley (slower)
Normal use The corrected power Pc is
n1 (RPM) speed of smaller pulley (faster) P (kW) power to be transmitted Drives up to 15 kW Pc= P × Fs= 12 × 1,2 = 14,4 kW Metal and wood working machines Reduced noise, reduced vibration
d (mm) pitch diameter of smaller pulley Pc (kW) corrected power Fans, pumps, compressors, line shafts, machine tools, 1,1 1,2 1,3 1,2 1,3 1,4 Because of the high power, we can go for a C section, expecting more than one belt to be used.
D (mm) pitch diameter of bigger pulley Pb (kW) basic performance of a single belt
punches, generators Poultry industry Enhanced resistance to harsh environment
Heavy conveyors DETERMINATION OF ACTUAL POWER RATING
I (mm) center distance Pa (kW) actual belt power Heavy use Agriculture Enhanced resistance to typical agri-environment
Arc of contact g
i transmission ratio Q number of belts Textile machines
g = 180 - (57 x [(D-d):l]) = 180 - (57 × [(12-8):38]) = 174°
saw mills, woodworking machines, 1,2 1,3 1,4 1,4 1,5 1,6 Easier and quicker to install
Ts (N) static belt tension v (m/s) peripheral belt speed This means that Cg is 0.98.
brick machines, piston compressors, Rolling conveyor
g (°) arc of contact Fs service factor paper mills, positive blowers The belt power rating Pa is
Pa= Pb× Cg = 8 × 0,98 = 7,84 kW Better performing in case of pulley misalignment

CHOICE OF BELT SECTION DETERMINATION OF NUMBER OF BELTS Glass industry No staining


where Pb comes from table 7.
To choose between the sections, to find out the corrected power (Pc ) it is first necessary to calculate: The number of belts comes from the following formula:
Pc= P × Fs Easier and quicker to install
Table 1: belt section selection DETERMINATION OF NUMBER OF BELTS
Q = Pc : Pa Tiles and marble conveyor
10000 The final number of belts is:
Enhanced resistance to harsh environment
Q = Pc: Pa = 14,4 : 7,84 = 1,84
The final number of belts is given by rounding up Q to the next higher integer number. This means that the actual number of needed belts is 2.
Rotational speed (1/min.)

1000
Trasmittable Power
Z/3L
A/4L Table 4 - Z/3L profile Table 5 - A/4L profile Table 6 - B/5L profile Table 7 - C profile
B/5L 1,10 4,50 9,00 16,00
C

100 1,00
4,00 8,00
14,00
0,90
3,50 7,00
12,00
0,80

3,00 6,00
0,70
10 10,00
0,1 1 10 100
2,50

HPower (kW)
5,00

Power (kW)
Power (kW)
0,60
Power (kW)

Power (kW) (Pc )


2'' pulley 2.6'' pulley 4.4'' pulley 8,00 7'' pulley
3'' pulley 5.2" pulley 8'' pulley
DETERMINATION OF ACTUAL POWER RATING 0,50
4" pulley
2,00 3.6'' pulley 4,00
4,6" pulley 6.8" pulley 10" pulley
The actual power rating Pa is given by the drive working conditions: 6,00
0,40
Pa = Pb × C g 1,50 3,00
where Pb is the power base of the belt and Cg is the arc of contact correction factor as per following table.
0,30
4,00
1,00 2,00
Table 2: arc of contact correction factor Cg 0,20
The arc of contact is calculated as follows: 2,00
0,50 1,00
g = 180- (57 x [(D-d):l]) 0,10

Arc of 0,00 0,00


180° 175° 170° 165° 160° 155° 150° 145° 140° 135° 130° 125° 120° 115° 110° 105° 100° 0,00 0,00
contact g 500 1500 2500 3500 4500 5500 600 1100 1600 2100 2600 3100 3600 4100 500 1000 1500 2000 2500 3000 3500 300 500 700 900 1100 1300 1500 1700 1900 2100 2300
Belt speed (RPM) Belt speed (RPM) Belt speed (RPM) Belt speed (RPM)
Cg 1,00 0,99 0,98 0,96 0,95 0,93 0,92 0,90 0,89 0,87 0,86 0,84 0,82 0,80 0,78 0,76 0,74
Technical calculation Table 3: service factor Fs Calculation example
DRIVES MACHINE DATA
Applications
TS (1) (2) P = 12 kW Thanks to their features, Accu-Link belts can be used in very wide range of applications. In the following table it is
AC electric motors: high slip, squirrel cage, synchronous AC electric motors: high torque, high slip, single phase, wound rotor, com- Speed: 1100 rpm possible to find a list of the main applications where Accu-Link are widely used with the advantages compared to
DC electric motors: parallel excitation mutator Drive sheave: 8”
Multi-cylinder internal combustion engines DC electric motors> series and compound excitation the classical rubber V-Belts.
Driven sheave: 12”
Gas or steam turbines Single-cylinder internal combustion engines with direct coupling or with
D d γO countershaft
Center distance: 38”

TS Steam engines APPLICATIONS MAIN ADVANTAGES


Daily operating hours Application: compressor
Applications Type of engine: 1 Higher resistance to salty and greasy environment
0-8 (1) 8-16 (1) 16-24 (1) 0-8 (2) 8-16 (2) 16-24 (2)
l Light use
Working hours: 8-16 per day Marine industry
Fs will be 1,2 Reduced inventory
Classical industrial drives up to 5 kW
1,0 1,1 1,2 1,1 1,2 1,3
SYMBOL UNIT DEFINITION SYMBOL Fans, pumps, compressors
Light conveyors CHOICE OF BELT SECTION Air handling Easier and quicker to install
Cg correction factor n2 (RPM) speed of bigger pulley (slower)
Normal use The corrected power Pc is
n1 (RPM) speed of smaller pulley (faster) P (kW) power to be transmitted Drives up to 15 kW Pc= P × Fs= 12 × 1,2 = 14,4 kW Metal and wood working machines Reduced noise, reduced vibration
d (mm) pitch diameter of smaller pulley Pc (kW) corrected power Fans, pumps, compressors, line shafts, machine tools, 1,1 1,2 1,3 1,2 1,3 1,4 Because of the high power, we can go for a C section, expecting more than one belt to be used.
D (mm) pitch diameter of bigger pulley Pb (kW) basic performance of a single belt
punches, generators Poultry industry Enhanced resistance to harsh environment
Heavy conveyors DETERMINATION OF ACTUAL POWER RATING
I (mm) center distance Pa (kW) actual belt power Heavy use Agriculture Enhanced resistance to typical agri-environment
Arc of contact g
i transmission ratio Q number of belts Textile machines
g = 180 - (57 x [(D-d):l]) = 180 - (57 × [(12-8):38]) = 174°
saw mills, woodworking machines, 1,2 1,3 1,4 1,4 1,5 1,6 Easier and quicker to install
Ts (N) static belt tension v (m/s) peripheral belt speed This means that Cg is 0.98.
brick machines, piston compressors, Rolling conveyor
g (°) arc of contact Fs service factor paper mills, positive blowers The belt power rating Pa is
Pa= Pb× Cg = 8 × 0,98 = 7,84 kW Better performing in case of pulley misalignment

CHOICE OF BELT SECTION DETERMINATION OF NUMBER OF BELTS Glass industry No staining


where Pb comes from table 7.
To choose between the sections, to find out the corrected power (Pc ) it is first necessary to calculate: The number of belts comes from the following formula:
Pc= P × Fs Easier and quicker to install
Table 1: belt section selection DETERMINATION OF NUMBER OF BELTS
Q = Pc : Pa Tiles and marble conveyor
10000 The final number of belts is:
Enhanced resistance to harsh environment
Q = Pc: Pa = 14,4 : 7,84 = 1,84
The final number of belts is given by rounding up Q to the next higher integer number. This means that the actual number of needed belts is 2.
Rotational speed (1/min.)

1000
Trasmittable Power
Z/3L
A/4L Table 4 - Z/3L profile Table 5 - A/4L profile Table 6 - B/5L profile Table 7 - C profile
B/5L 1,10 4,50 9,00 16,00
C

100 1,00
4,00 8,00
14,00
0,90
3,50 7,00
12,00
0,80

3,00 6,00
0,70
10 10,00
0,1 1 10 100
2,50

HPower (kW)
5,00

Power (kW)
Power (kW)
0,60
Power (kW)

Power (kW) (Pc )


2'' pulley 2.6'' pulley 4.4'' pulley 8,00 7'' pulley
3'' pulley 5.2" pulley 8'' pulley
DETERMINATION OF ACTUAL POWER RATING 0,50
4" pulley
2,00 3.6'' pulley 4,00
4,6" pulley 6.8" pulley 10" pulley
The actual power rating Pa is given by the drive working conditions: 6,00
0,40
Pa = Pb × C g 1,50 3,00
where Pb is the power base of the belt and Cg is the arc of contact correction factor as per following table.
0,30
4,00
1,00 2,00
Table 2: arc of contact correction factor Cg 0,20
The arc of contact is calculated as follows: 2,00
0,50 1,00
g = 180- (57 x [(D-d):l]) 0,10

Arc of 0,00 0,00


180° 175° 170° 165° 160° 155° 150° 145° 140° 135° 130° 125° 120° 115° 110° 105° 100° 0,00 0,00
contact g 500 1500 2500 3500 4500 5500 600 1100 1600 2100 2600 3100 3600 4100 500 1000 1500 2000 2500 3000 3500 300 500 700 900 1100 1300 1500 1700 1900 2100 2300
Belt speed (RPM) Belt speed (RPM) Belt speed (RPM) Belt speed (RPM)
Cg 1,00 0,99 0,98 0,96 0,95 0,93 0,92 0,90 0,89 0,87 0,86 0,84 0,82 0,80 0,78 0,76 0,74
Technical calculation Table 3: service factor Fs Calculation example
DRIVES MACHINE DATA
Applications
TS (1) (2) P = 12 kW Thanks to their features, Accu-Link belts can be used in very wide range of applications. In the following table it is
AC electric motors: high slip, squirrel cage, synchronous AC electric motors: high torque, high slip, single phase, wound rotor, com- Speed: 1100 rpm possible to find a list of the main applications where Accu-Link are widely used with the advantages compared to
DC electric motors: parallel excitation mutator Drive sheave: 8”
Multi-cylinder internal combustion engines DC electric motors> series and compound excitation the classical rubber V-Belts.
Driven sheave: 12”
Gas or steam turbines Single-cylinder internal combustion engines with direct coupling or with
D d γO countershaft
Center distance: 38”

TS Steam engines APPLICATIONS MAIN ADVANTAGES


Daily operating hours Application: compressor
Applications Type of engine: 1 Higher resistance to salty and greasy environment
0-8 (1) 8-16 (1) 16-24 (1) 0-8 (2) 8-16 (2) 16-24 (2)
l Light use
Working hours: 8-16 per day Marine industry
Fs will be 1,2 Reduced inventory
Classical industrial drives up to 5 kW
1,0 1,1 1,2 1,1 1,2 1,3
SYMBOL UNIT DEFINITION SYMBOL Fans, pumps, compressors
Light conveyors CHOICE OF BELT SECTION Air handling Easier and quicker to install
Cg correction factor n2 (RPM) speed of bigger pulley (slower)
Normal use The corrected power Pc is
n1 (RPM) speed of smaller pulley (faster) P (kW) power to be transmitted Drives up to 15 kW Pc= P × Fs= 12 × 1,2 = 14,4 kW Metal and wood working machines Reduced noise, reduced vibration
d (mm) pitch diameter of smaller pulley Pc (kW) corrected power Fans, pumps, compressors, line shafts, machine tools, 1,1 1,2 1,3 1,2 1,3 1,4 Because of the high power, we can go for a C section, expecting more than one belt to be used.
D (mm) pitch diameter of bigger pulley Pb (kW) basic performance of a single belt
punches, generators Poultry industry Enhanced resistance to harsh environment
Heavy conveyors DETERMINATION OF ACTUAL POWER RATING
I (mm) center distance Pa (kW) actual belt power Heavy use Agriculture Enhanced resistance to typical agri-environment
Arc of contact g
i transmission ratio Q number of belts Textile machines
g = 180 - (57 x [(D-d):l]) = 180 - (57 × [(12-8):38]) = 174°
saw mills, woodworking machines, 1,2 1,3 1,4 1,4 1,5 1,6 Easier and quicker to install
Ts (N) static belt tension v (m/s) peripheral belt speed This means that Cg is 0.98.
brick machines, piston compressors, Rolling conveyor
g (°) arc of contact Fs service factor paper mills, positive blowers The belt power rating Pa is
Pa= Pb× Cg = 8 × 0,98 = 7,84 kW Better performing in case of pulley misalignment

CHOICE OF BELT SECTION DETERMINATION OF NUMBER OF BELTS Glass industry No staining


where Pb comes from table 7.
To choose between the sections, to find out the corrected power (Pc ) it is first necessary to calculate: The number of belts comes from the following formula:
Pc= P × Fs Easier and quicker to install
Table 1: belt section selection DETERMINATION OF NUMBER OF BELTS
Q = Pc : Pa Tiles and marble conveyor
10000 The final number of belts is:
Enhanced resistance to harsh environment
Q = Pc: Pa = 14,4 : 7,84 = 1,84
The final number of belts is given by rounding up Q to the next higher integer number. This means that the actual number of needed belts is 2.
Rotational speed (1/min.)

1000
Trasmittable Power
Z/3L
A/4L Table 4 - Z/3L profile Table 5 - A/4L profile Table 6 - B/5L profile Table 7 - C profile
B/5L 1,10 4,50 9,00 16,00
C

100 1,00
4,00 8,00
14,00
0,90
3,50 7,00
12,00
0,80

3,00 6,00
0,70
10 10,00
0,1 1 10 100
2,50

HPower (kW)
5,00

Power (kW)
Power (kW)
0,60
Power (kW)

Power (kW) (Pc )


2'' pulley 2.6'' pulley 4.4'' pulley 8,00 7'' pulley
3'' pulley 5.2" pulley 8'' pulley
DETERMINATION OF ACTUAL POWER RATING 0,50
4" pulley
2,00 3.6'' pulley 4,00
4,6" pulley 6.8" pulley 10" pulley
The actual power rating Pa is given by the drive working conditions: 6,00
0,40
Pa = Pb × C g 1,50 3,00
where Pb is the power base of the belt and Cg is the arc of contact correction factor as per following table.
0,30
4,00
1,00 2,00
Table 2: arc of contact correction factor Cg 0,20
The arc of contact is calculated as follows: 2,00
0,50 1,00
g = 180- (57 x [(D-d):l]) 0,10

Arc of 0,00 0,00


180° 175° 170° 165° 160° 155° 150° 145° 140° 135° 130° 125° 120° 115° 110° 105° 100° 0,00 0,00
contact g 500 1500 2500 3500 4500 5500 600 1100 1600 2100 2600 3100 3600 4100 500 1000 1500 2000 2500 3000 3500 300 500 700 900 1100 1300 1500 1700 1900 2100 2300
Belt speed (RPM) Belt speed (RPM) Belt speed (RPM) Belt speed (RPM)
Cg 1,00 0,99 0,98 0,96 0,95 0,93 0,92 0,90 0,89 0,87 0,86 0,84 0,82 0,80 0,78 0,76 0,74
ACCU-LINK
BELARUS Qingdao HUNGARY U.S.A
Range Minsk Longshan town office, Budapest California
Kuzme Chornogo 31 -901 Nange backstreet Jimo city – West Gate Business Park 5660-5680 Rickenbacker Road Bell
Accu-Link belts are available in Z/3L, A/4L, B/5L and C sections. Accu-Link can work on standard pulleys for V-belts. 220100 Minsk Qingdao – Shandong, 266100 Topark u. 9 Los Angeles, CA 90201
Megadyne can supply open end Acculink in carton boxes or endless belts in light carton sleeves. Phone +375 17 2802486 Phone +86 532 8765 2117 2045 Torokbalint Phone +1 323 265 8061 Accu-Link is the Megadyne’s link belt, created and developed as
Info.ee@megadynegroup.com info.cn@megadynegroup.com Phone +36 23 428 628 inquiries@jasonindustrial.com an alternative to classical rubber V-belts. Megadyne’s Accu-Link
Z/3L A/4L B/5L C info.hu@megadynegroup.com combines superior strength and durability with quick and easy
BRASIL Shanghai Florida
Belt weight g/m (+/-1,5) 43,0 76,5 117,5 178,5 assembly and installation. The original concept is to give a fast
Sorocaba Business Office A area, MEXICO 5120-B East Adamo Drive Tampa,
Min pulley diameter (mm) 45 80 140 225 Avenida Dr. Armando Pannunzio 6th Floor, 11th Building, Mexico C.P. FL 33619 replacement to classical V-belts in case of break. Despite this, thanks
610 CEP 18050-000 No.1588, Li an Road Av. Ceylan 959 Int. 9 Y 10 Phone +1 813 241 4111 to the performance of link belts, today Accu-Link is used in a very wide
Service temperature range -25 °C / +80 °C (-13 °F / 176 °F) Sorocaba, São Paulo Shanghai, 201105 Industrial Vallejo Azcapotzalco, inquiries@jasonindustrial.com range of applications as original equipment.
Standard roll lengths (ft) 25-100 25-100 25-100 25-50 Phone +55 15 2101 7700 Phone +86 21 5447 1473 Mexico C.P. 02300
inquiries@jasonindustrial.com info.cn@megadynegroup.com Phone +52 55 5587 3680 Georgia Accu-Link is a link belt: it means it is made of several links assembled all
Standard sleeve lengths (ft) 5 5-6 6 5 inquiries@jasonindustrial.com Belt Corporation of America together. Thanks to this, belts can have every length just by modifying
CANADA Shenyang 253 Castleberry Industrial Dr. the number of links.
Edmonton Room303, Flat 3, No.131-9 POLAND Cumming, GA 30040
Measuring Assembling 10020 42nd Avenue Edmonton
Alberta T6E 5B4
Baogong South St.
Tiexi District
Bydgoszcz
Ołowiana 10, 85-461 Bydgoszcz
Phone +770 887-9725
inquiries@jasonindustrial.com
Links are made with a polyurethane polymer reinforced by a multilayer
woven polyester fabric. The design of the links and the state-of-art
Phone: +1 780 461 4400 Shenyang,110074 POLAND
manufacturing process allow superior performances and finishing
inquiries@jasonindustrial.com Phone +86 24 2572 3238 Phone +48 52 348 77 12 Illinois
Fax +86 24 2572 3238 info.pl@megadynegroup.com 221 South Westgate Drive
quality. Accu-Link is ground to get a smooth and precise side edge
Montreal info.cn@megadynegroup.com Carol Stream, IL 60188 and section, leading to a low vibrating belt and a smooth and silent
9135 Cote De Liesse SOUTH AFRICA Phone: +1630 752 0600 transmission.
Dorval, Quebec H9P 2N9 COLOMBIA Johannesburg inquiries@jasonindustrial.com
Phone: +1 514 31 2341 Cartagena Unit 4 - 6, 24 Park Avenue South The belt is delivered already assembled and pre-tensioned to reduce
inquiries@jasonindustrial.com Diag 22-56-112 - Highway Business Park - New Jersey Americas HQ the elongation especially during the early stage of its start-up.
Bario el Bosque Rooihuiskraal,Centurion 340 Kaplan Drive Fairfield
Toronto Cartagena, Colombia Phone +27 (0)12 661 1652 NJ 07004
1. Holding the belt with the 2. Flexing the belt as much as 3. Ensure that tab will
927 Matheson Boulevard East NIT 900-648-909-6 Fax +27 (0)12 661 1634 Phone +1 973 227 4904
1. Pull the belt tight around tabs upwards, let the tab of needed, twist and insert the stay transversally to the Mississauga, Ontario L4W 2R7 Phone: 011 57 313 501 5397 info.sa@megadynegroup.com inquiries@jasonindustrial.com
the sheaves to check the Phone: +1 905 602 4400 inquiries@jasonindustrial.com
one belt’s end get through second tab through the end link. belt’s running direction; inquiries@jasonindustrial.com SPAIN North Carolina
needed length, overlapping two links at once. reverse the belt upside
CHINA
CZECH REPUBLIC
Praha
Barcelona
Ctra de l’Arboc, Km 1,7
11016 Granite Street, Charlotte,
NC 28273 Main features and advantages:
the last two tabs .with two (three if C section) down to let it running on Beijing Karlovarska Business Park 08800 Vilanova I La Geltru Phone +1 704 583 5388
NO.37-344 Fudongyuan.Ciqu Street Na Hurce 1077/4 (Budova C), Barcelona inquiries@jasonindustrial.com • EASY TO ASSEMBLE
holes in matching.
Disassembling the tab side.
Taihu town, Tongzhou 161 00 – Phone +34 93 811 5450 Accu-Link can be assembled without any tool and in a matter of
2. Count the number of links Beijing 101111 Praha 6 – Ruzyne info.sp@megadynegroup.com Oregon seconds.
Phone +86 10 8150 7478 Phone +420 2 8481 7181 One SE Alder St., Portland,
and remove one link every info.cn@megadynegroup.com office.cz@megadynegroup.com SWEDEN OR 97214
• EASY TO INSTALL
24 for Z/3L, A/4L and B/5L Kristianstad Phone +1 888 231 7224 Accu-Link can be adapted to every length; in case of difficult layout
Foshan FRANCE Estrids Väg 15 inquiries@jasonindustrial.com or when taking the drive apart would take too long. Acculink can be
sections, and one link every n.5 Hedang Industrial Area Paris 291 65 Kristianstad installed open and closed afterwards, in a very easy and fast way.
East Side Wu Gang Road Logistic Center Zi Les Bordes - 15 Phone +46 10 1309600 South Carolina
20 for C section to get the • SMALL INVENTORY

ACCU-LINK
Changcheng district, Foshan Rue Gustave Madiot info.se@megadynegroup.com 101 Pelham Davis Cir, Greenville,
proper installation tension. Guangdong 528031 91923 Bondoufle Cedex SC 29615-5752 With one roll of Accu-Link it is possible to get any length of classical
Phone +86 757 83815530 Phone +33 1 6079 8200 THAILAND Phone +1 864 288 9916 V-belts; with one roll per section, inventories will be much smaller,
3. For multiple belt drives, 1. Put the belt with the tabs 2. Twist one tab 90° to 3. Rotating the belt by 90° info.cn@megadynegroup.com info.fr@megadynegroup.com Bangkok inquiries@jasonindustrial.com easier and cheaper to manage.
upwards and bend it as much as make it parallel to the you can now easily pull one S.S.P. Tower – 16th Floor –
be ensure that each belt has Fujiang St. Jean De Maurienne Office 10 Soi Sukhumvit 63 Texas • HIGH POWER RATE
possible. belt; in this way you can belt’s end away from the No.720 Marketing Comprehesive le prè de la Garde -Av. Italie- (Ekamai) Klong Tan Nuea, 8510 Ambassador Row, Dallas Accu-Link has power ratings similar to classical V-belts.
the same number of links.
pull the end of the link other one. Building, South Lingshui Street 73300 S. Jean de Maurienne Vadhana Bangkok 10110 TX 75247
Wuli Industrial Park, Phone +33 4 7964 0613 Phone: +66 (0) 27115477 Phone +1 972 438 6992 • HIGH RESISTANCE TO ENVIRONMENT
over the tab. Jinjang City, Fujian, 362261 info.fr@megadynegroup.com info.apac@megadynegroup.com inquiries@jasonindustrial.com Thanks to its state-of-the-art materials, Accu-Link can withstand to
NOTE: Unlike conventional V-Belts, Accu-Link can be rolled onto pulleys - no cord to break. Phone +86 595 8816 0309 salt, chemicals, mineral pure oils and greases. This increases the
info.cn@megadynegroup.com GERMANY TURKEY life time compared to standard rubber V-belts.
Borchen Izmir
Installation Ningbo
Industrial Chemical Area,
Nikolaus Otto Straße 24
33178 Borchen
Mustafa Kemal Ataturk Mahallesi
Izmir Ankara Asfalti Caddesi
• HIGH TEMPERATURE RESISTANCE
Accu-Link can operate un a wide range of temperature:
1. Be sure that the belt has the tabs on the inner side: the belt has to run with the tabs oppositely facing the running direction; Fengxiang Road 777, Xiepu Town Phone +49 5251 8735 0 No:19, 35170 Ulucak Kemalpasa -25 °C / +80 °C (-13 °F / 176 °F)
Zhenghai District, info.de@megadynegroup.com Phone +90 232 877 07 00
2. Fit the belt in the nearest groove of the smallest sheave and then roll the belt onto the larger sheave. For multiple belts drive, • HIGH RESISTACE TO HARSH ENVIRONMENT
Ningbo City , Zhejiang Province, info@rultrans.com.tr HEADQUARTERS
repeat the operation on all the grooves 315203 Elchingen Accu-Link is suited for harsh environment where it can last ever
3. Always make sure that belts look pretty tight and tabs are still in the correct position. Phone +86 574 8650 2886 Daimlerstraße 13 U.K. ITALY Torino longer than standard rubber V-belts.
info.cn@megadynegroup.com 89275 Elchingen Birmingham Via S. Lucia, 114
If it is easy to move the engine, you might install the belt in the following way: Phone +49 7308 9665 0 Unit 1, The Washington Centre, 10075 Mathi (Torino) • QUIET AND SMOOTH RUNNING
produktion@megadynegroup.com Halesowen Road, Netherton, Phone +39 011 926 8052 Thanks to the superior finishing, Accu-Link may run quieter and
1. Set the engine in mid position of its adjustment range and mark this position clearly; Dudley, West Midlands, DY2 9RE info@megadynegroup.com smoother than a V-belt.
2. Check the belt’s length as previously shown; Phone: +44 1384 215 021
sales@megadynegroup.com www.megadynegroup.com
3. Move the engine forward to reduce the center distance;
www.jasonindustrial.com
4. Install the belt as in “INSTALLATION” paragraph;
5. Pull the engine back to the previously marked position.
Edition: March 2015

Retensioning
As in any V-Belt drive, Acculink belts require to check for tension after 24 h of full load operating time. If the belt is not tight
enough, restore the tension by removing some link. Anyway, check the belt’s tension periodically and restore tension.
ACCU-LINK
BELARUS Qingdao HUNGARY U.S.A
Range Minsk Longshan town office, Budapest California
Kuzme Chornogo 31 -901 Nange backstreet Jimo city – West Gate Business Park 5660-5680 Rickenbacker Road Bell
Accu-Link belts are available in Z/3L, A/4L, B/5L and C sections. Accu-Link can work on standard pulleys for V-belts. 220100 Minsk Qingdao – Shandong, 266100 Topark u. 9 Los Angeles, CA 90201
Megadyne can supply open end Acculink in carton boxes or endless belts in light carton sleeves. Phone +375 17 2802486 Phone +86 532 8765 2117 2045 Torokbalint Phone +1 323 265 8061 Accu-Link is the Megadyne’s link belt, created and developed as
Info.ee@megadynegroup.com info.cn@megadynegroup.com Phone +36 23 428 628 inquiries@jasonindustrial.com an alternative to classical rubber V-belts. Megadyne’s Accu-Link
Z/3L A/4L B/5L C info.hu@megadynegroup.com combines superior strength and durability with quick and easy
BRASIL Shanghai Florida
Belt weight g/m (+/-1,5) 43,0 76,5 117,5 178,5 assembly and installation. The original concept is to give a fast
Sorocaba Business Office A area, MEXICO 5120-B East Adamo Drive Tampa,
Min pulley diameter (mm) 45 80 140 225 Avenida Dr. Armando Pannunzio 6th Floor, 11th Building, Mexico C.P. FL 33619 replacement to classical V-belts in case of break. Despite this, thanks
610 CEP 18050-000 No.1588, Li an Road Av. Ceylan 959 Int. 9 Y 10 Phone +1 813 241 4111 to the performance of link belts, today Accu-Link is used in a very wide
Service temperature range -25 °C / +80 °C (-13 °F / 176 °F) Sorocaba, São Paulo Shanghai, 201105 Industrial Vallejo Azcapotzalco, inquiries@jasonindustrial.com range of applications as original equipment.
Standard roll lengths (ft) 25-100 25-100 25-100 25-50 Phone +55 15 2101 7700 Phone +86 21 5447 1473 Mexico C.P. 02300
inquiries@jasonindustrial.com info.cn@megadynegroup.com Phone +52 55 5587 3680 Georgia Accu-Link is a link belt: it means it is made of several links assembled all
Standard sleeve lengths (ft) 5 5-6 6 5 inquiries@jasonindustrial.com Belt Corporation of America together. Thanks to this, belts can have every length just by modifying
CANADA Shenyang 253 Castleberry Industrial Dr. the number of links.
Edmonton Room303, Flat 3, No.131-9 POLAND Cumming, GA 30040
Measuring Assembling 10020 42nd Avenue Edmonton
Alberta T6E 5B4
Baogong South St.
Tiexi District
Bydgoszcz
Ołowiana 10, 85-461 Bydgoszcz
Phone +770 887-9725
inquiries@jasonindustrial.com
Links are made with a polyurethane polymer reinforced by a multilayer
woven polyester fabric. The design of the links and the state-of-art
Phone: +1 780 461 4400 Shenyang,110074 POLAND
manufacturing process allow superior performances and finishing
inquiries@jasonindustrial.com Phone +86 24 2572 3238 Phone +48 52 348 77 12 Illinois
Fax +86 24 2572 3238 info.pl@megadynegroup.com 221 South Westgate Drive
quality. Accu-Link is ground to get a smooth and precise side edge
Montreal info.cn@megadynegroup.com Carol Stream, IL 60188 and section, leading to a low vibrating belt and a smooth and silent
9135 Cote De Liesse SOUTH AFRICA Phone: +1630 752 0600 transmission.
Dorval, Quebec H9P 2N9 COLOMBIA Johannesburg inquiries@jasonindustrial.com
Phone: +1 514 31 2341 Cartagena Unit 4 - 6, 24 Park Avenue South The belt is delivered already assembled and pre-tensioned to reduce
inquiries@jasonindustrial.com Diag 22-56-112 - Highway Business Park - New Jersey Americas HQ the elongation especially during the early stage of its start-up.
Bario el Bosque Rooihuiskraal,Centurion 340 Kaplan Drive Fairfield
Toronto Cartagena, Colombia Phone +27 (0)12 661 1652 NJ 07004
1. Holding the belt with the 2. Flexing the belt as much as 3. Ensure that tab will
927 Matheson Boulevard East NIT 900-648-909-6 Fax +27 (0)12 661 1634 Phone +1 973 227 4904
1. Pull the belt tight around tabs upwards, let the tab of needed, twist and insert the stay transversally to the Mississauga, Ontario L4W 2R7 Phone: 011 57 313 501 5397 info.sa@megadynegroup.com inquiries@jasonindustrial.com
the sheaves to check the Phone: +1 905 602 4400 inquiries@jasonindustrial.com
one belt’s end get through second tab through the end link. belt’s running direction; inquiries@jasonindustrial.com SPAIN North Carolina
needed length, overlapping two links at once. reverse the belt upside
CHINA
CZECH REPUBLIC
Praha
Barcelona
Ctra de l’Arboc, Km 1,7
11016 Granite Street, Charlotte,
NC 28273 Main features and advantages:
the last two tabs .with two (three if C section) down to let it running on Beijing Karlovarska Business Park 08800 Vilanova I La Geltru Phone +1 704 583 5388
NO.37-344 Fudongyuan.Ciqu Street Na Hurce 1077/4 (Budova C), Barcelona inquiries@jasonindustrial.com • EASY TO ASSEMBLE
holes in matching.
Disassembling the tab side.
Taihu town, Tongzhou 161 00 – Phone +34 93 811 5450 Accu-Link can be assembled without any tool and in a matter of
2. Count the number of links Beijing 101111 Praha 6 – Ruzyne info.sp@megadynegroup.com Oregon seconds.
Phone +86 10 8150 7478 Phone +420 2 8481 7181 One SE Alder St., Portland,
and remove one link every info.cn@megadynegroup.com office.cz@megadynegroup.com SWEDEN OR 97214
• EASY TO INSTALL
24 for Z/3L, A/4L and B/5L Kristianstad Phone +1 888 231 7224 Accu-Link can be adapted to every length; in case of difficult layout
Foshan FRANCE Estrids Väg 15 inquiries@jasonindustrial.com or when taking the drive apart would take too long. Acculink can be
sections, and one link every n.5 Hedang Industrial Area Paris 291 65 Kristianstad installed open and closed afterwards, in a very easy and fast way.
East Side Wu Gang Road Logistic Center Zi Les Bordes - 15 Phone +46 10 1309600 South Carolina
20 for C section to get the • SMALL INVENTORY

ACCU-LINK
Changcheng district, Foshan Rue Gustave Madiot info.se@megadynegroup.com 101 Pelham Davis Cir, Greenville,
proper installation tension. Guangdong 528031 91923 Bondoufle Cedex SC 29615-5752 With one roll of Accu-Link it is possible to get any length of classical
Phone +86 757 83815530 Phone +33 1 6079 8200 THAILAND Phone +1 864 288 9916 V-belts; with one roll per section, inventories will be much smaller,
3. For multiple belt drives, 1. Put the belt with the tabs 2. Twist one tab 90° to 3. Rotating the belt by 90° info.cn@megadynegroup.com info.fr@megadynegroup.com Bangkok inquiries@jasonindustrial.com easier and cheaper to manage.
upwards and bend it as much as make it parallel to the you can now easily pull one S.S.P. Tower – 16th Floor –
be ensure that each belt has Fujiang St. Jean De Maurienne Office 10 Soi Sukhumvit 63 Texas • HIGH POWER RATE
possible. belt; in this way you can belt’s end away from the No.720 Marketing Comprehesive le prè de la Garde -Av. Italie- (Ekamai) Klong Tan Nuea, 8510 Ambassador Row, Dallas Accu-Link has power ratings similar to classical V-belts.
the same number of links.
pull the end of the link other one. Building, South Lingshui Street 73300 S. Jean de Maurienne Vadhana Bangkok 10110 TX 75247
Wuli Industrial Park, Phone +33 4 7964 0613 Phone: +66 (0) 27115477 Phone +1 972 438 6992 • HIGH RESISTANCE TO ENVIRONMENT
over the tab. Jinjang City, Fujian, 362261 info.fr@megadynegroup.com info.apac@megadynegroup.com inquiries@jasonindustrial.com Thanks to its state-of-the-art materials, Accu-Link can withstand to
NOTE: Unlike conventional V-Belts, Accu-Link can be rolled onto pulleys - no cord to break. Phone +86 595 8816 0309 salt, chemicals, mineral pure oils and greases. This increases the
info.cn@megadynegroup.com GERMANY TURKEY life time compared to standard rubber V-belts.
Borchen Izmir
Installation Ningbo
Industrial Chemical Area,
Nikolaus Otto Straße 24
33178 Borchen
Mustafa Kemal Ataturk Mahallesi
Izmir Ankara Asfalti Caddesi
• HIGH TEMPERATURE RESISTANCE
Accu-Link can operate un a wide range of temperature:
1. Be sure that the belt has the tabs on the inner side: the belt has to run with the tabs oppositely facing the running direction; Fengxiang Road 777, Xiepu Town Phone +49 5251 8735 0 No:19, 35170 Ulucak Kemalpasa -25 °C / +80 °C (-13 °F / 176 °F)
Zhenghai District, info.de@megadynegroup.com Phone +90 232 877 07 00
2. Fit the belt in the nearest groove of the smallest sheave and then roll the belt onto the larger sheave. For multiple belts drive, • HIGH RESISTACE TO HARSH ENVIRONMENT
Ningbo City , Zhejiang Province, info@rultrans.com.tr HEADQUARTERS
repeat the operation on all the grooves 315203 Elchingen Accu-Link is suited for harsh environment where it can last ever
3. Always make sure that belts look pretty tight and tabs are still in the correct position. Phone +86 574 8650 2886 Daimlerstraße 13 U.K. ITALY Torino longer than standard rubber V-belts.
info.cn@megadynegroup.com 89275 Elchingen Birmingham Via S. Lucia, 114
If it is easy to move the engine, you might install the belt in the following way: Phone +49 7308 9665 0 Unit 1, The Washington Centre, 10075 Mathi (Torino) • QUIET AND SMOOTH RUNNING
produktion@megadynegroup.com Halesowen Road, Netherton, Phone +39 011 926 8052 Thanks to the superior finishing, Accu-Link may run quieter and
1. Set the engine in mid position of its adjustment range and mark this position clearly; Dudley, West Midlands, DY2 9RE info@megadynegroup.com smoother than a V-belt.
2. Check the belt’s length as previously shown; Phone: +44 1384 215 021
sales@megadynegroup.com www.megadynegroup.com
3. Move the engine forward to reduce the center distance;
www.jasonindustrial.com
4. Install the belt as in “INSTALLATION” paragraph;
5. Pull the engine back to the previously marked position.
Edition: March 2015

Retensioning
As in any V-Belt drive, Acculink belts require to check for tension after 24 h of full load operating time. If the belt is not tight
enough, restore the tension by removing some link. Anyway, check the belt’s tension periodically and restore tension.

You might also like