You are on page 1of 28

Certificate Number Issued 1 stApril 2003

BAS97ATEX1089X/6 Page 1 of 2

1
SUPPLEMENTARY EC -TYPE EXAMINATION CERTIFICATE
2 Equipmeut or Protective SystemIntended for use in Potentially Explosive Atmospheres
Directive 94/9/EC
3 SupplementaryEC -Type BAS97ATEXIO89x/6
ExaminationCertificateNumber:
4 Equipmentor ProtectiveSystem: MODEL 3051C PRESSURETRANSMITTER
5 Manufacturer: ROSEMOUNT INC
6 Address: 12001TechnologyDrive, Eden Prairie, Minnesota 55344-3695,USA
7 This supplementarycertificate extendsEC -Type ExaminationCertificate No. BAS97ATEXIO89X to apply to
equipmentor protective systemsdesignedand constructedin accordancewith the specification set out in the
Scheduleof the said certificate but having any variationsspecifiedin the Scheduleattachedto this certificate and
the documentsthereinreferredto.

This supplementarycertificate shallbe held with the original certificate.

The original certificatewas issuedby The ElectricalEquipmentCertification Service,Notified Body Number0600,


which retains responsibilityfor its original documentation.Baseefa(2001) Ltd., Notified Body Number 1180,is
responsibleonly for the additional work relating to this supplementarycertificate and any other supplementary
certificate it hasissued.

This certificate may only be reproducedin its entirety,without any change,scheduleincluded

Baseefa(2001)Ltd. CustomerReferenceNo. 0914 ProjectFile No. 02/0417

-/'

~()~
Baseefa (2001) Ltd. RSSINCLAIR
Health and Safety Laboratory Site, Harpur Hill,
Buxton, Derbyshire SK17 9JN
DIRECTOR
Telephone +44 (0) 129828255 Fax +44 (0) 129828216 On behalf of
e-mail info@baseefa2001.biz web site www.baseefa2001.biz Baseefa(2001)Ltd.
Registered in England No. 4305578 at 13 Dovedale Crescent, Buxton,
Derbyshire, SK17 9BJ

"'-"--~
Certificate Number Issued 1stApril 2003
BAS97ATEX1089X/6 Page 2 of 2

13 Schedule
14 Certificate Number BAS97 A TEXl 089X/6

15 Description of the variation to the Equipment or Protective System

Variation6.1
To permit minor drawingchangesthat do not affectthe intrinsic safetyassessment

16 ReportNumber
None

17 SpecialConditions for SafeUse


None additionalto thoselisted previously

18 Essential Health and Safety Requirements


Compliance with the Essential Health and Safety Requirements is not affected by this variation.

Issue Date Description


03031-0214 1 to 3 AC 06/06/02 Filter, RFI
03031-0225 1 to 3 AB 06/06/02 Filter, RFI
03031-0590 1 to 4 AB 08/23/01 PWB LCD Board, 2 Line
03031-0591 1 to 3 AG 11/13/01 Circuit card assemblyLCD Board, 2 Line
03031-0654 1 AA 10/26/00 Potting Summary
03031-0923 1 AB 02/15/01 Circuit card assemblySensorBoard
03031-0929 1 AK 04/15/02 Circuit card assemblySensorTaconite
03031-1017 1 to 6 AJ 09/18/01 Module Housing Assembly

The abovedrawingsare associatedwith CertificateNumberBASOOATEX3105X/3