R407C

NEW The High-efficiency


Air-cooled Chiller "H series"
The air-cooled chiller "H series" with improved efficiency and functionality
by several advanced technologies.
This series with the world's best standard A-type screw compressor and
newly designed shell and tube heat exchanger that have powerful cooling
ability, low noise, low vibration, high efficiency and high reliability is the
perfect answer to all your needs!!

E nhanced Line-up ~up to 400 HP~

H igh-performance A-type Screw Compressor

P recise Capacity Control Technology

E xcellent Control Function

H ighly Reliable Shell and Tube Heat Exchanger


Improved heat-exchange performance by
using inverse M type Air Side Heat Exchanger

Protection Net
(standard equipment)

Acoustic Chamber
(standard equipment)

Product Series
RCUG-AHYZ1 RCU-AHYZ1
Nominal Capacity Range (50Hz) Nominal Capacity Range (50Hz)

110 kW to 1,089 kW 116 kW to 1,146 kW


R407C 31 USRT to 310 USRT 33 USRT to 326 USRT
94,600 kcal/h to 936,540 kcal/h 99,760 kcal/h to 985,560 kcal/h

Wide Line-up
To meet the need for air conditioning systems for large facilities and the demand for
higher capacity industrial cooling systems.

40 50 60 75 100 120 150 160 180 200 240 270 300 330 350 360 380 400 (HP)
RCUG-AHYZ1

R407C

40 50 60 75 100 120 150 160 180 200 240 270 300 330 350 360 380 400 (HP)
RCU-AHYZ1

2
Technical Features

H igh-performance A-type Screw Compressor ~Newly Designed~


Built-in Cyclone Oil Separator
Low oil carrying-out is realized and reduction of heat
transfer efficiency is minimized.
NEW
High Technology by Internal Manufacture
Because all manufacturing processes, from rotor
manufacturing to unit assembly, are done internally,
exceptional reliability is achieved.

New Screw Compressor Operation Image

No outside pump is required due to Cyclone


Discharged Gas
the reliable differential-pressure Oil Separator
Suctioned
oil-feeding system. Refrigerant Gas
Screw Rotor
This oil-feeding system, which does not use any
electrical mechanism, prevents the compressor
Oil
from being damaged and maintains long-term
stable operation. Oil Reservoir

Differential Pressure
Lubrication Mechanism

Simple Structure with a Small Number of Parts


Whereas the number of main parts for the casing,
compression mechanism and capacity control mechanism
of a reciprocating compressor is 268, that of a screw
compressor is only 27, just one tenth of the number !
A structure with so few parts offers high reliability and
easy maintenance.

Vibration Comparison
Low Vibration Level Type Reciprocating Screw
No exclusive vibration control equipment is necessary Comp. speed (rpm) 50/60Hz 1,430 / 1,720 2,880 / 3,470
by using low-vibration screw compressor. At leg of comp. 20-30 5-8
Full amplitude
At base frame 20 Less than 10

At leg of comp. 23.8 / 28.7 48.5 / 57.8


Vib. frequecy
At base frame 23.8 / 28.7 48 / 57.8

Acceleration energy Screw: 1/5 of reciprocating type

3
P recise Capacity Control Technology
Continuous Capacity Control
The temperature of the chilled water outlet can be kept at the set temperature
±1°C by continuous capacity control, so it is suitable for industrial use.

Load-up signal When there is a big difference


Capacity Controller Structural Outline
between set temperature and (HITACHI Patented System)
12sec.
actual temperature.
Start 60sec.

Inlet water Load-up signal Inlet water Load-up Load-down


temperature temperature Slide Valve Low Pressure Slide Valve Low Pressure
Gas Gas
2sec.
Bypass Gas Bypass Gas
Outlet water 60sec. Outlet water Ps
Ps
temperature temperature Pd Pd

8
Suction Suction
Neutral zone Gas SV3 Gas SV3
6 standard
Rotor SV1 SV2 Rotor SV1 SV2
4 Stop temperature
High Pressure Oil High Pressure Oil
Stop standard
Lapsed time
Pd: Discharge pressure, Ps: Suction pressure,
Load-down signal The inlet water temperature is
A given load status SV1,2,3 : Solenoid valve : Valve open : Valve close
detected at a stop, and it is
is maintained.
2sec.
restarted by a rise in inlet
60sec.
water temperature.

E xcellent Control Function


Building Management System (BMS)
R
Hitachi uses Building Management System through LONWORKS . For chiller air-conditioning,
Hitachi provides its own central station system. No complicated work is necessary.
R

* : "LONWORKS " is a trademark of Echelon Corporation registered in the United States and other countries.

BMS System List of Functions


(Supplied by BMS
Maker)
*
Remote Setting
Other Building Equipment ON / OFF Operation
Chilled Water Temperature (Inlet or Outlet)

G/W communication adapter (option) Remote Monitor


ON / OFF Status
G/W communication adapter (option) can be connected up to 4 units.
Setting Chilled Water Temperature (Inlet or Outlet)
Current Water Temperature of Inlet and Outlet
Alarm Code

* In addition, up to 8 units can be connected using the G/W communication


adapter for the Hitachi Chiller Unit signal (RS485).
* Equipment below the dotted line is provided by HITACHI

H ighly Reliable Shell and Tube Heat Exchanger ~Newly Designed~


Dry expansion cooler system
Low environmental impact: refrigerant quantity reduced by 60% from the current unit
Perfect matching with the chiller unit due to our own design
- Downsized by redesigned heat-transfer tube
- Improved efficiency by optimized refrigerant distribution

4
R407C General Data
Model RCUG40AHYZ1 RCUG50AHYZ1 RCUG60AHYZ1 RCUG75AHYZ1 RCUG100AHYZ1
Power Source Main (AC 3φ) 380, 415V / 50Hz, Control (AC 1φ) 220, 240V / 50Hz
kW 110 136 170 181 272
Nominal Cooling Capacity*1 USRT 31 39 48 51 77
kcal/h 94,600 116,960 146,200 155,660 233,920
Continuous Capacity Control
Capacity Control
% 100~15, 0 100~15(7.5)*2, 0
Height 2,170 2,170 2,170 2,170 2,170
Outer Dimensions Width mm 1,940 1,940 1,940 1,940 1,940
Depth 2,390 2,390 2,390 2,390 4,490
Net Weight kg 1,790 1,830 1,870 1,890 3,210
Type R407C
Refrigerant Flow Control Thermal Expansion Valve
Number of Circuits 1 2
Type Semi-Hermetic Screw Type
Compressor Model 40ASCC-Z 50ASCC-Z 60ASCC-Z 60ASCC-Z 50ASCC-Z
Quantity 1 2
Condenser Cross Fin Type
Condenser Fan Direct Drive Propeller Fan
Heat Fan
Exchanger Motor Power Intput kW 1.1 1.1 1.1 1.1 1.1
Quantity 4 4 4 4 8
Evaporator Shell-and-Tube Type
Overcurrent Relay for Compressor, Internal Thermostat for Compressor, Reverse Phase Protection Device for Compressor,
Thermal Overcurrent Relay for Fan Motor, High-Pressure Switch, Low-Pressure Control, Suction Gas Temperature Control,
Safety Devices
Freeze Protection Thermistor Control, Oil Heater, Discharge Gas Thermistor, Fusible Plug, Fuse for Control Circuit and
Pressure Relief Valve
Height 2,510 2,510 2,510 2,510 2,510
Shipping
Width mm 2,190 2,190 2,190 2,190 2,190
Dimensions
Depth 2,600 2,600 2,600 2,600 4,700
Shipping Weight kg 2,000 2,040 2,080 2,100 3,610
Piping Connections for Inlet With φ142 Inner Diameter
Water Side Heat Exchanger With φ90 Inner Diameter Companion Flange
Outlet Companion Flange
Main Power
500 x 160
Connection Hole (square orifice) mm
Circuit φ48; φ64.5; φ102; φ52 2 xφ48; φ64.5; φ102; φ52

Model RCUG270AHYZ1 RCUG300AHYZ1 RCUG330AHYZ1 RCUG350AHYZ1 RCUG360AHYZ1


Power Source Main (AC 3φ) 380, 415V / 50Hz, Control (AC 1φ) 220, 240V / 50Hz
kW 703 726 873 907 1,020
Nominal Cooling Capacity*1 USRT 200 206 248 258 290
kcal/h 604,580 624,360 750,780 780,020 877,200
Continuous Capacity Control
Capacity Control
% 100~15(7.5)*2, 0 100~15(6)*2, 0 100~15(7.5)*2, 0
Height 2,170 2,170 2,170 2,170 2,170
Outer Dimensions Width mm 1,940 1,940 1,940 1,940 1,940
Depth 9,080(min.) 9,080(min.) 11,180(min.) 11,180(min.) 13,280(min.)
Net Weight kg 3,320 + 3,280 2 x 3,320 4,865 + 3,320 4,900 + 3,320 2 x 4,865
Type R407C
Refrigerant Flow Control Thermal Expansion Valve
Number of Circuits 4 5 6
Type Semi-Hermetic Screw Type
Compressor Model 60ASCC-Z 60ASCC-Z 60ASCC-Z 60ASCC-Z 60ASCC-Z
Quantity 4 5 6
Condenser Cross Fin Type
Condenser Fan Direct Drive Propeller Fan
Fan
Heat kW 1.1 1.1 1.1 1.1 1.1
Motor Power Intput
Exchanger Quantity 8+8 2x8 12 + 8 12 + 8 2 x 12
Evaporator Shell-and-Tube Type
Overcurrent Relay for Compressor, Internal Thermostat for Compressor, Reverse Phase Protection Device for Compressor,
Safety Devices Thermal Overcurrent Relay for Fan Motor, High-Pressure Switch, Low-Pressure Control, Suction Gas Temperature Control,
Freeze Protection Thermistor Control, Oil Heater, Discharge Gas Thermistor, Fusible Plug, Fuse for Control Circuit and
Pressure Relief Valve
Height 2,510 2,510 2,510 2,510 2,510
Shipping Width mm 2,190 2,190 2,190 2,190 2,190
Dimensions Depth 2 x 4,700 2 x 4,700 6,800 + 4,700 6,800 + 4,700 2 x 6,800
Shipping Weight kg 3,720 + 3,680 2 x 3,720 5,500 + 3,720 5,535 + 3,720 2 x 5,500
Piping Connections for Inlet
Water Side Heat Exchanger With φ142 Inner Diameter Companion Flange
Outlet
Main Power
2 x 500 x 160
Connection Hole (square orifice) mm
Circuit 4 xφ48; 2 xφ64.5; 2 xφ102; 2 xφ52 5 xφ48; 2 xφ64.5; 2 xφ102; 3 xφ52 6 xφ48; 2 xφ64.5; 2 xφ102; 4 xφ52

5
R407C

RCUG120AHYZ1 RCUG150AHYZ1 RCUG160AHYZ1 RCUG180AHYZ1 RCUG200AHYZ1 RCUG240AHYZ1


Main (AC 3φ) 380, 415V / 50Hz, Control (AC 1φ) 220, 240V / 50Hz
340 363 408 510 544 680
97 103 116 145 155 193
292,400 312,180 350,880 438,600 467,840 584,800
Continuous Capacity Control
100~15(7.5)*2, 0 100~15(5)*2, 0 100~15(7.5)*2, 0
2,170 2,170 2,170 2,170 2,170 2,170
1,940 1,940 1,940 1,940 1,940 1,940
4,490 4,490 6,590 6,590 6,590 9,080(min.)
3,280 3,320 4,745 4,865 4,900 2 x 3,280
R407C
Thermal Expansion Valve
2 3 4
Semi-Hermetic Screw Type
60ASCC-Z 60ASCC-Z 50ASCC-Z 60ASCC-Z 60ASCC-Z 60ASCC-Z
2 3 4
Cross Fin Type
Direct Drive Propeller Fan
1.1 1.1 1.1 1.1 1.1 1.1
8 8 12 12 12 2x8
Shell-and-Tube Type
Overcurrent Relay for Compressor, Internal Thermostat for Compressor, Reverse Phase Protection Device for Compressor,
Thermal Overcurrent Relay for Fan Motor, High-Pressure Switch, Low-Pressure Control, Suction Gas Temperature Control,
Freeze Protection Thermistor Control, Oil Heater, Discharge Gas Thermistor, Fusible Plug, Fuse for Control Circuit and
Pressure Relief Valve
2,510 2,510 2,510 2,510 2,510 2,510
2,190 2,190 2,190 2,190 2,190 2,190
4,700 4,700 6,800 6,800 6,800 2 x 4,700
3,680 3,720 5,380 5,500 5,535 2 x 3,680

With φ142 Inner Diameter Companion Flange

500 x 160 2 x 500 x 160

2 xφ48; φ64.5; φ102; φ52 3 xφ48; φ64.5; φ102; 2 xφ52 4 xφ48; 2 xφ64.5; 2 xφ102; 2 xφ52

RCUG380AHYZ1 RCUG400AHYZ1 NOTES:


Main (AC 3φ) 380, 415V / 50Hz, Control (AC 1φ) 220, 240V / 50Hz
1. The nominal cooling capacities are based on the following conditions. (*1)
1,055 1,089
Chilled Water Inlet / Outlet Temperature: 12˚C / 7˚C
300 310
Condenser Air Inlet Temperature: 35˚C(DB)
907,300 936,540
Continuous Capacity Control
2. The units greater than 240AHYZ1 including 240AHYZ1consist of
100~15(7.5)*2, 0
2,170 2,170
two modules and are separately shipped.
1,940 1,940
The common chilled water piping (Filed-Supplied) between each
13,280(min.) 13,280(min.) water cooler shall be directly connected at site.
4,900 + 4,865 2 x 4,900
R407C 3. Water Flow
Thermal Expansion Valve 1) RCUG240, 300, 360, 400AHYZ1
6 It is necessary to control the common water flow volume to each cooler.
Semi-Hermetic Screw Type 2) RCUG270, 330, 350, 380AHYZ1
60ASCC-Z 60ASCC-Z The chilled water flow rate is different between No.1 & No.2 units.
6 It is necessary to control the water flow volume of each unit with
Cross Fin Type adjusting valves (Filed-Supplied).
Direct Drive Propeller Fan
1.1 1.1 4. It is required to connect electrical control wires between No.1 & No.2
12 + 12 2 x 12 units for the unit greater than 240AHYZ1 including 240AHYZ1.
Shell-and-Tube Type
Overcurrent Relay for Compressor, Internal Thermostat for Compressor, Reverse Phase Protection
Device for Compressor, Thermal Overcurrent Relay for Fan Motor, High-Pressure Switch, Low-
5. ( ) marked with *2 is available by selection switch.
Pressure Control, Suction Gas Temperature Control, Freeze Protection Thermistor Control, Oil
Heater, Discharge Gas Thermistor, Fusible Plug, Fuse for Control Circuit and Pressure Relief Valve
2,510 2,510
2,190 2,190
2 x 6,800 2 x 6,800
Working Range
5,535 + 5,500 2 x 5,535

With φ142 Inner Diameter Companion Flange


Item Standard

Chilled Water Outlet Temperature 5~15˚C


2 x 500 x 160

6 xφ48; 2 xφ64.5; 2 xφ102; 4 xφ52


Condenser Air Inlet Temperature (DB) 5~43˚C

6
R22 General Data
Model RCU40AHYZ1 RCU50AHYZ1 RCU60AHYZ1 RCU75AHYZ1 RCU100AHYZ1
Power Source Main (AC 3φ) 380, 415V / 50Hz, Control (AC 1φ) 220, 240V / 50Hz
kW 116 143 179 191 286
Nominal Cooling Capacity*1 USRT 33 41 51 54 81
kcal/h 99,760 122,980 153,940 164,260 245,960
Continuous Capacity Control
Capacity Control
% 100~15, 0 100~15(7.5)*2, 0
Height 2,170 2,170 2,170 2,170 2,170
Outer Dimensions Width mm 1,940 1,940 1,940 1,940 1,940
Depth 2,390 2,390 2,390 2,390 4,490
Net Weight kg 1,790 1,830 1,870 1,890 3,210
Type R22
Refrigerant Flow Control Thermal Expansion Valve
Number of Circuits 1 2
Type Semi-Hermetic Screw Type
Compressor Model 40ASCC-Z 50ASCC-Z 60ASCC-Z 60ASCC-Z 50ASCC-Z
Quantity 1 2
Condenser Cross Fin Type
Condenser Fan Direct Drive Propeller Fan
Heat Fan
Exchanger Motor Power Intput kW 1.1 1.1 1.1 1.1 1.1
Quantity 4 4 4 4 8
Evaporator Shell-and-Tube Type
Overcurrent Relay for Compressor, Internal Thermostat for Compressor, Reverse Phase Protection Device for Compressor,
Thermal Overcurrent Relay for Fan Motor, High-Pressure Switch, Low-Pressure Control, Suction Gas Temperature Control,
Safety Devices
Freeze Protection Thermistor Control, Oil Heater, Discharge Gas Thermistor, Fusible Plug, Fuse for Control Circuit and
Pressure Relief Valve
Height 2,510 2,510 2,510 2,510 2,510
Shipping
Width mm 2,190 2,190 2,190 2,190 2,190
Dimensions
Depth 2,600 2,600 2,600 2,600 4,700
Shipping Weight kg 2,000 2,040 2,080 2,100 3,610
Piping Connections for Inlet With φ142 Inner Diameter
Water Side Heat Exchanger With φ90 Inner Diameter Companion Flange
Outlet Companion Flange
Main Power
500 x 160
Connection Hole (square orifice) mm
Circuit φ48; φ64.5; φ102; φ52 2 xφ48; φ64.5; φ102; φ52

Model RCU270AHYZ1 RCU300AHYZ1 RCU330AHYZ1 RCU350AHYZ1 RCU360AHYZ1


Power Source Main (AC 3φ) 380, 415V / 50Hz, Control (AC 1φ) 220, 240V / 50Hz
kW 740 764 919 955 1,074
Nominal Cooling Capacity*1 USRT 210 217 261 272 305
kcal/h 636,400 657,040 790,340 821,300 923,640
Continuous Capacity Control
Capacity Control
% 100~15(7.5)*2, 0 100~15(6)*2, 0 100~15(7.5)*2, 0
Height 2,170 2,170 2,170 2,170 2,170
Outer Dimensions Width mm 1,940 1,940 1,940 1,940 1,940
Depth 9,080(min.) 9,080(min.) 11,180(min.) 11,180(min.) 13,280(min.)
Net Weight kg 3,320 + 3,280 2 x 3,320 4,865 + 3,320 4,900 + 3,320 2 x 4,865
Type R22
Refrigerant Flow Control Thermal Expansion Valve
Number of Circuits 4 5 6
Type Semi-Hermetic Screw Type
Compressor Model 60ASCC-Z 60ASCC-Z 60ASCC-Z 60ASCC-Z 60ASCC-Z
Quantity 4 5 6
Condenser Cross Fin Type
Condenser Fan Direct Drive Propeller Fan
Fan
Heat kW 1.1 1.1 1.1 1.1 1.1
Motor Power Intput
Exchanger Quantity 8+8 2x8 12 + 8 12 + 8 2 x 12
Evaporator Shell-and-Tube Type
Overcurrent Relay for Compressor, Internal Thermostat for Compressor, Reverse Phase Protection Device for Compressor,
Safety Devices Thermal Overcurrent Relay for Fan Motor, High-Pressure Switch, Low-Pressure Control, Suction Gas Temperature Control,
Freeze Protection Thermistor Control, Oil Heater, Discharge Gas Thermistor, Fusible Plug, Fuse for Control Circuit and
Pressure Relief Valve
Height 2,510 2,510 2,510 2,510 2,510
Shipping Width mm 2,190 2,190 2,190 2,190 2,190
Dimensions Depth 2 x 4,700 2 x 4,700 6,800 + 4,700 6,800 + 4,700 2 x 6,800
Shipping Weight kg 3,720 + 3,680 2 x 3,720 5,500 + 3,720 5,535 + 3,720 2 x 5,500
Piping Connections for Inlet
Water Side Heat Exchanger With φ142 Inner Diameter Companion Flange
Outlet
Main Power
2 x 500 x 160
Connection Hole (square orifice) mm
Circuit 4 xφ48; 2 xφ64.5; 2 xφ102; 2 xφ52 5 xφ48; 2 xφ64.5; 2 xφ102; 3 xφ52 6 xφ48; 2 xφ64.5; 2 xφ102; 4 xφ52

7
RCU120AHYZ1 RCU150AHYZ1 RCU160AHYZ1 RCU180AHYZ1 RCU200AHYZ1 RCU240AHYZ1
Main (AC 3φ) 380, 415V / 50Hz, Control (AC 1φ) 220, 240V / 50Hz
358 382 429 537 573 716
102 109 122 153 163 204
307,880 328,520 368,940 461,820 492,780 615,760
Continuous Capacity Control
100~15(7.5)*2, 0 100~15(5)*2, 0 100~15(7.5)*2, 0
2,170 2,170 2,170 2,170 2,170 2,170
1,940 1,940 1,940 1,940 1,940 1,940
4,490 4,490 6,590 6,590 6,590 9,080(min.)
3,280 3,320 4,745 4,865 4,900 2 x 3,280
R22
Thermal Expansion Valve
2 3 4
Semi-Hermetic Screw Type
60ASCC-Z 60ASCC-Z 50ASCC-Z 60ASCC-Z 60ASCC-Z 60ASCC-Z
2 3 4
Cross Fin Type
Direct Drive Propeller Fan
1.1 1.1 1.1 1.1 1.1 1.1
8 8 12 12 12 2x8
Shell-and-Tube Type
Overcurrent Relay for Compressor, Internal Thermostat for Compressor, Reverse Phase Protection Device for Compressor,
Thermal Overcurrent Relay for Fan Motor, High-Pressure Switch, Low-Pressure Control, Suction Gas Temperature Control,
Freeze Protection Thermistor Control, Oil Heater, Discharge Gas Thermistor, Fusible Plug, Fuse for Control Circuit and
Pressure Relief Valve
2,510 2,510 2,510 2,510 2,510 2,510
2,190 2,190 2,190 2,190 2,190 2,190
4,700 4,700 6,800 6,800 6,800 2 x 4,700
3,680 3,720 5,380 5,500 5,535 2 x 3,680

With φ142 Inner Diameter Companion Flange

500 x 160 2 x 500 x 160

2 xφ48; φ64.5; φ102; φ52 3 xφ48;φ64.5;φ102; 2 xφ52 4 xφ48; 2 xφ64.5; 2 xφ102; 2 xφ52

RCU380AHYZ1 RCU400AHYZ1 NOTES:


Main (AC 3φ) 380, 415V / 50Hz, Control (AC 1φ) 220, 240V / 50Hz
1. The nominal cooling capacities are based on the following conditions. (*1)
1,110 1,146
Chilled Water Inlet / Outlet Temperature: 12˚C / 7˚C
316 326
Condenser Air Inlet Temperature: 35˚C(DB)
954,600 985,560
Continuous Capacity Control
2. The units greater than 240AHYZ1 including 240AHYZ1consist of
100~15(7.5)*2, 0
2,170 2,170
two modules and are separately shipped.
1,940 1,940 The common chilled water piping (Filed-Supplied) between each
13,280(min.) 13,280(min.) water cooler shall be directly connected at site.
4,900 + 4,865 2 x 4,900
R22 3. Water Flow
Thermal Expansion Valve 1) RCU240, 300, 360, 400AHYZ1
6 It is necessary to control the common water flow volume to each cooler.
Semi-Hermetic Screw Type 2) RCU270, 330, 350, 380AHYZ1
60ASCC-Z 60ASCC-Z The chilled water flow rate is different between No.1 & No.2 units.
6 It is necessary to control the water flow volume of each unit with
Cross Fin Type adjusting valves (Filed-Supplied).
Direct Drive Propeller Fan
1.1 1.1 4. It is required to connect electrical control wires between No.1 & No.2
12 + 12 2 x 12 units for the unit greater than 240AHYZ1 including 240AHYZ1.
Shell-and-Tube Type
Overcurrent Relay for Compressor, Internal Thermostat for Compressor, Reverse Phase Protection
Device for Compressor, Thermal Overcurrent Relay for Fan Motor, High-Pressure Switch, Low-
5. ( ) marked with *2 is available by selection switch.
Pressure Control, Suction Gas Temperature Control, Freeze Protection Thermistor Control, Oil
Heater, Discharge Gas Thermistor, Fusible Plug, Fuse for Control Circuit and Pressure Relief Valve
2,510 2,510
2,190 2,190
2 x 6,800 2 x 6,800
Working Range
5,535 + 5,500 2 x 5,535

With φ142 Inner Diameter Companion Flange


Item Standard

Chilled Water Outlet Temperature 5~15˚C


2 x 500 x 160

6 xφ48; 2 xφ64.5; 2 xφ102; 4 xφ52


Condenser Air Inlet Temperature (DB) 5~43˚C

8
Dimensional Data
R407C RCUG40, 50, 60 and 75AHYZ1
R22 RCU40, 50, 60 and 75AHYZ1
2,390 1,900
290 2,100
Air Side Heat Exchanger Air Discharge

Air Inlet Air Inlet


Electric Control Box
2,170
Water Outlet Temperature
(With 90mm Inner
Diameter Frange)
Screw Type

350
Compressor Water Inlet Temperature
485

(With 90mm Inner Rigging Holes (4-φ50)

300
Diameter Frange)
Earth Connection Terminal M10 Mounting Holes (4-φ26)

100 1,900 52.5 (1,945) 52.5


2,050
700 1,110
100

71 160
500

Fan

Wiring Hole for Power Supply NOTE:


It should be surpport the water pipings properly to avoid its
weight press on the unit directly.

R407C RCUG100, 120 and 150AHYZ1


R22 RCU100, 120 and 150AHYZ1
4,490 1,900
290 4,200
Air Side Heat Exchanger Air Discharge

Air Inlet Air Inlet


2,170

Water Outlet Temperature


(With 142mm Inner Electric Control Box
Diameter Frange)
350

Water Inlet Temperature


(With 142mm Inner
485

Diameter Frange) Rigging Holes (4-φ50)


300

Earth Connection Terminal M10 Screw Type Compressor Mounting Holes (6-φ26)

150 1,950 1,950 52.5 (1,945) 52.5


2,050
1,140 2,090
100

71 160
500

NOTE:
Fan It should be surpport the water pipings properly to avoid its weight press
on the unit directly.
Wiring Hole for Power Supply

R407C RCUG160, 180 and 200AHYZ1


R22 RCU160, 180 and 200AHYZ1
6,590 1,900
290 6,300
Air Side Heat Exchanger Air Discharge

Air Inlet Air Inlet


2,170

Water Outlet Temperature


Electric Control Box
(With 142mm Inner
Diameter Frange)
430

Water Inlet Temperature


(With 142mm Inner
485

Diameter Frange) Rigging Holes (4-φ50)


264

Earth Connection Terminal M10 Screw Type Compressor Mounting Holes (8-φ26)
150 1,950 2,100 1,950
52.5 (1,945) 52.5
3,125 2,150
100

2,050
71 160
Fan
500

NOTES:
1. It should be surpport the water pipings properly to avoid its
Wiring Hole for weight press on the unit directly.
Power Supply 2. Water connection flange (142mm) are supplied by factory
with the unit.

9
R407C RCUG240, 270 and 300AHYZ1
R22 RCU240, 270 and 300AHYZ1
9,080(min.) 1,900
4,490 100(min.) 4,490
290 4,200 4,200 290
Air Side Heat Exchanger Air Side Heat Exchanger Air Discharge

Air Inlet Air Inlet


2,170

Water Outlet Temperature Electric Control Box


(With 142mm Inner
Diameter Frange)
Rigging Holes

264 430
(8-φ50)
485

Mounting Holes
Earth Connection Terminal M10 Screw Type Compressor Earth Connection Terminal M10 Water Inlet Temperature (12-φ26)
(With 142mm Inner
150 1,950 1,950 150 1,950 1,950
Diameter Frange) 52.5 (1,945) 52.5
4,200 4,200 2,050
No.1 Water Outlet No.1 Water Inlet No.2 Water Outlet No.2 Water Inlet NOTES:
1,140 2,090 2,210 2,090 1. It should be surpport the water pipings properly to avoid its weight
100

press on the unit directly.


71 160 2. These chillers consist of unit No.1 & No.2 and they are supplied
separately when dispatched.
500

3. Water Flow
For RCU(G)240,300AHYZ1: It is necessary to control the same
water quantity to each cooler. For RCU(G)270AHYZ1: The chilled
Fan water flow rate is different between No.1 & No.2 unit...
Wiring Hole for It is necessary to control the water quantity of each unit with
Power Supply adjusting valves (Field-Supplied).
4. It needs to field connect the control wiring between the No.1 & No.2.

R407C RCUG330 and 350AHYZ1


R22 RCU330 and 350AHYZ1
11,180(min.) 1,900
6,690 4,490
290 6,300 100(min.) 4,200 290
Air Side Heat Exchanger Air Side Heat Exchanger
Air Discharge

Air Inlet Air Inlet


Water Outlet Temperature
2,170

Electric Control Box


(With 142mm Inner
Diameter Frange)
Rigging Holes
264 430 (8-φ50)
485

P Mounting Holes
Earth Connection Terminal M10 Screw Type Compressor Earth Connection Terminal M10 Water Inlet Temperature (14-φ26)
150 1,950 2,100 1,950 150 1,950 1,950 (With 142mm Inner 52.5 (1,945) 52.5
Diameter Frange) 2,050
No.1 Water Outlet No.1 Water Inlet No.2 Water Outlet No.2 Water Inlet
NOTES:
3,125 2,150 2,120 2,090
100

1. It should be surpport the water pipings properly to avoid its weight


71 160 press on the unit directly.
2. These chillers consist of unit No.1 & No.2 and they are supplied
separately when dispatched.
500

3. Water Flow
For RCU(G)330,350AHYZ1: The chilled water flow rate is different
between No.1 & No.2 unit. It is necessary to control the water quantity of
each unit with adjusting valves (Field-Supplied).
Wiring Hole for Power Supply Fan 4. It needs to field connect the control wiring between the No.1 & No.2.
5. In the No.2 unit, the data with the P mark is 300mm.

R407C RCUG360, 380 and 400AHYZ1


R22 RCU360, 380 and 400AHYZ1
13,280(min.) 1,900
6,590 6,590
290 6,300 100(min.) 6,300 290
Air Side Heat Exchanger Air Side Heat Exchanger Air Discharge

Air Inlet Air Inlet


Water Outlet Temperature
2,170

(With 142mm Inner Electric


Diameter Frange) Control Box
Rigging Holes
264 430

(8-φ50)
485

Water Inlet Temperature Mounting Holes


Earth Connection Terminal M10 Screw Type Compressor Earth Connection Terminal M10 (16-φ26)
(With 142mm Inner
150 1,950 2,100 1,950 150 1,950 2,100 1,950 Diameter Frange) 52.5 (1,945) 52.5
2,050

No.1 Water Outlet No.1 Water Inlet No.2 Water Outlet No.2 Water Inlet NOTES:
3,125 2,150 4,105 2,150 1. It should be surpport the water pipings properly to avoid its weight
100

press on the unit directly.


71 160
2. These chillers consist of unit No.1 & No.2 and they are supplied
separately when dispatched.
500

3. Water Flow
For RCU(G)360,400AHYZ1: It is necessary to control the same
water quantity to each cooler. For RCU(G)380AHYZ1: The chilled
water flow rate is different between No.1 & No.2 unit.
It is necessary to control the water quantity of each unit with
Wiring Hole for Power Supply Fan adjusting valves (Field-Supplied).
4. It needs to field connect the control wiring between the No.1 & No.2.

10