EDG-170E
POWER RATING
Prime power 130 kW, 163 kVA 155 kW, 194 kVA
Standby power 145 kW, 181 kVA 170 kW, 212 kVA
Power ratings are made in accordance with ISO8528
RELIABLE HIGH QUALITY FREQUENCY REGULATION Applied the 2/3 pitch winding to
SYSTEM- To improve the ACCURACY- Under varying reduce the 3rd harmonics.
performance of Products, high loads from no load to 100% load
quality auxiliaries equipment at the rated power factor(0.8), Designed by using the latest
applied and optimized protection frequency regulation is technologies and the best
device built in the digital 5%(mechanical type governor), materials available to guarantee
controller against malfunctioning 1%(electric type governor). high efficiency value.
and abnormal conditions.
VOLTAGE REGULATION Impregnated with high-grade
SIMPLE AND EASY ACCURACY- Under varying resin and protection against
OPERATION- With centralized loads from no load to 100% load hostile environment is provided
controls simplifying generator at the rated power factor (0.8), as standard.
operation and supervision is voltage regulation is less than
made very simple. ±2.5%. Supplied with over exciting
current and under frequency
LOW COST MAINTENANCE & VOLTAGE ADJUSTABLE protection built in the AVR.
OPERATION- Use the RANGE- Under rated speed and
specialized diesel engine for no load condition, voltage Suitable for parallel operation
generator set keeps operation adjustable range is less than with other generator or mains
costs very low. ±5% of rated voltage. power. (Parallel kit is available
on request.)
SPECIFICATION
SWITCH& PUSH BUTTON
Manual/Remote/Auto button O
Stop button O
GCB Close/Trip button O
Alarm button O
Direction/Enter/ESC button O
Emergency stop push button O
Main Power Switch O
Voltage Adjuster O
DISPLAY
Digital Volt./Current/Power/PF/Hz O
Running Hours/Kilowatt hour O
RPM/DC Voltage O
Oil press./Coolant temp O
Cooldown time/Mains power live/Failure sensing time O
BREAKER
Main molded case circuit breaker (MCCB 4P) O (3P as option)
Circuit protector for DC source O
Breaker for main power/coolant heater O
INDICATOR & PROTECTION SYSTEM
Main power lamp O
Manual/Remote/Auto, LED O
Running, LED O
GCB close/trip, LED O
Emergency stop, LCD O
Over voltage/Under voltage/Over Current, LCD O
High coolant temperature, LCD O
Low lub. oil pressure, LCD O
Fail to start, LCD O
Over speed, LCD O
REMOTE SYSTEM
PC Monitoring program ▲
Dry Contact (Mains Power, Running, Fault) O
CONTROL SYSTEM
SPEED CONTROL UNIT O
OTHERS
Dry Contact (Extension Module) ▲
Battery Charger O
Engine Engine
Fuel oil filter Battery auto charger (For Standby Power usage)
Lub. oil filter and drain valve
Air cleaner Control panel
Lubricate oil Analog control panel
Fan Belt Self-standing panel
Parallel control panel : Island or Grid Mode
Control panel
Digital control panel (EDGC10) Enclosed Unit
Weather Proof Enclosure
Exhaust Sound Proof Enclosure
Silencer (Sound attenuation up to 20db) Containerized Enclosure
Bellows
Cold climate heater
Voltage Connection Coolant heater, AC 120V/240V
- 50Hz: 400V/230V Fuel heater, DC 24V
- 60Hz: 380V/220V Air heater, DC 12V * 2EA
L : 4500mm, W : 2700mm
NOISE LEVEL
NO LOAD FULL LOAD
TYPE
1m 7m 1m 7m
SOUND PROOF 80 dB 70 dB 82 dB 71 dB