EnvE EnviroCard

Environmental Engineering

Aquifer
EnvE EnviroCard
Environmental Engineering

Darcy’s Law
EnvE EnviroCard
Environmental Engineering

Remediation
EnvE EnviroCard
Environmental Engineering

Terms
EnvE EnviroCard
Environmental Engineering

Pumping and Cone of Depression


EnvE EnviroCard
Environmental Engineering

Steady Flow to a Well Confined Aquifer

Qw = 2 π T (S1 - S2) / (ln (r2/r1))


EnvE EnviroCard
Environmental Engineering

Wells, Pumping - Confined Aquifer

Qw = 2 π T (S1 - S2) / (ln (r2/r1))

Qw = 2 π T (S1 - S2) / (ln (r2/r1))


EnvE EnviroCard
Environmental Engineering

Wells, Pumping - Unconfined Aquifer

Qw = 2 π T (S1
- S2) / (ln
(r2/r1))

Qw = 2 π T (S1 - S2) / (ln (r2/r1))


Qw = π K (h22- h12) / (ln (r2/r1))

A well pumps 0.4 m3/s from an unconfined aquifer whose saturated thickness
is 24 m. If the drawdown 50 m aafrom the well is 1 m and the drawdown 100 m
from the well is 0.5 m, then calculate the hydraulic conductivity of the aquifer.

Qw = 2 π T (S1 - S2) / (ln (r2/r1))