You are on page 1of 1

load cells

Note:
3000d merupakan standar resolusi
Load cell accuracy (% of Rated Capacity): Default accuracy MT Load Cell

Absolute error (kg): Error penimbangan setiap menimbang, refer to total load cells rate capacity

System capacity (kg): Kapasitas tank yg digunakan dalam proses


Load cell utilization (%): Kemampuan load cell yg dimanfaatkan, makin besar nilainya makin bagus
Typical readability (kg): Readability terdisplay pada terminal indicator display
Loadcell Accuracy to System Capacity (kg): Accuracy load cell terhadap system capacity

Total Tank Capacity (kg) 2,410.00


ST 2000 1.1T
Safety factor 1.25
Support Leg 3
Weigh module Capacity/ leg (kg) 1,004.17 Menggunakn type SWB505
Total @ support leg (1100 kg) 3,300.00 SWB505; Size 2; Cap: 1100 kg

Using WM Kit + Dummy LC


Load cell accuracy (% of Rated Capacity) 0.02% Standart Accuracy MT Analog Loadcell
Total tank legs 3
Load cells rated capacity (kg) 1,100.00
Total number of load cell 1
Total Rated Gross capacity (kg) 3,300.00 fill in based on customer need
Absolute error (kg) 1.980
System capacity (kg) 2,410.00 fill in based on customer need
Dead weight (pre-load) (kg) 0
Load cell utilization (%) 73.030
Relative system accuracy (%) 0.08%
Typical readability (kg) 0.803 Standart Resolution = 3000d
Loadcell Accuracy to System Capacity (kg) 1.980