Daxom / NAVİELS 6~48 kW

GENERAL SPECIFICATIONS Technical Information


Power Dimension Weight
Ÿ High Efficiency with full modulation operation Model (kW) H*W*D (mm) (kg)
Ÿ Instant and continious hot water with external boiler 3~400 V, 50 Hz Electrical Boiler With External Tank
Ÿ Touch operated and easy using stylish control pannel UKDAX-10HBT 10 700*400*230 23,5
Ÿ Setting boiler temperature from control pannel and UKDAX-12HBT 12 700*400*230 23,5
display of settings. UKDAX-16HBT 16 700*400*230 25,0
Ÿ Can be operated three phase or single phase UKDAX-18HBT 18 700*400*230 25,0
Ÿ Can be identifiable 7 programs as Daily or weekly UKDAX-20HBT 20 700*400*230 25,0
Ÿ Can be identifiable different operation UKDAX-24HBT 24 700*400*230 25,0
temperature for every programme UKDAX-30HBT 30 700*450*300 32,2
Ÿ Floor heating (low temperature) and radiator heating UKDAX-36HBT 36 700*450*300 35,4
system UKDAX-40HBT 40 700*450*300 35,4

Ÿ Compatible operation with solar energy system UKDAX-48HBT 48 700*450*300 35,4

Ÿ Internal three way valve 1~220 V, 50 Hz Electrical Boiler With External Tank
UKDAX-6HBM 6 700*400*230 23,5
Ÿ Three level pump
UKDAX-10HBM 10 700*400*230 23,5
Ÿ Unti blockage system for pump and three way valve
UKDAX-12HBM 12 700*400*230 23,5
Ÿ Power setting with three level
UKDAX-16HBM 16 700*400*230 25,0
Ÿ Summer – Winter position option UKDAX-18HBM 18 700*400*230 25,0
Ÿ Double freezing prevention system
Ÿ Overheat security system General Technical Specificitions
Ÿ Flow control security system Min. Operation Pressure bar 1
Ÿ Operation without water security system Max. Operation Pressure bar
3
Ÿ Double over pressure security system Radiator Operation Setting Temperature °C 10-80
Ÿ Automatic air relief cock Boiler Operation Setting Temperature °C 35-65
Ÿ Second pump connection option Radiator Connections inch 3/4
Ÿ %99 efficiency Boiler Connections inch 3/4
Water Filling Connections inch 1/2

*Heating DHW Tank Capacity (liter) ∆t=50°C


Time
1- Radiator outlet connection (min) 100 160 200 300 400 500 800 1000 1500
6 58 93 116 174 233 291 465 581 872
2- Boiler coin outlet connection
10 35 56 70 105 140 174 279 349 523
3- Boiler coin inlet connection
12 29 47 58 87 116 145 233 291 436
Boiler Capacity (kW)

4- Water feed connection


16 22 35 44 65 87 109 174 218 327
5- Radiator Inlet connection
18 19 31 39 58 78 97 155 194 291
6- Water feed tap 20 17 28 35 52 70 87 140 174 262
7- Safety valve discharge outlet 24 15 23 29 44 58 73 116 145 218
30 12 19 23 35 47 58 93 116 174
36 10 16 19 29 39 48 78 97 145
7 6 40 9 14 17 26 35 44 70 87 131
48 7 12 15 22 29 36 58 73 109
* It is calculated approximately supposing not heat loss and usage. Heating
time can show a change with various reasons. Contact with our company
1 2 3 4 5 engineer for heating time of different capacity boilers.

Isı Cihazları Sanayi ve Ticaret Limited Şirketi


Namık Kemal Mahallesi Marmara Caddesi No:74
34702 - ÜMRANİYE / İSTANBUL / TÜRKİYE
Tel: (0216) 369 85 36 - 360 23 40 - 360 71 21

www.daxom.com.tr

Naviels
Electric Boiler
Isı Cihazları San. ve Tic. Ltd. Şti, reserves the right to modify the characteristics and
information contained in this document at any time and without advance warning.

You might also like