Condensing Wall Hung Gas Boiler

EFFICIENCY ««««
Comfort and confidence suits to your life According to EEC 92/42 European Community Satandards
Condensing Wall Hung Gas Boiler

Daxom / NAVİDENS 52,4~145 kW

NAVİDENS 125

NAVİDENS 145
NAVİDENS 50

NAVİDENS 70
TECHNICAL
UNIT
SPECIFICITIONS

High Eficiency
Fuel Types - G20/G30
Al-Mg-Si cast
heatexchnager Pipe Types - B23,C13,C33,C43,C83
50-30 oC kW 52,4 68 125 145
Heat Power
80-60 oC kW 48,4 64 112,5 131,2
Max. kW 49,9 66 117 136,7
Heat Load
Min. kW 10 12 17 22
Fuel Max. m3/h 5,4 6,9 11,4 13,3
3
Consumption Min. m /h 1,1 1,3 1,5 1,9
Efficiency
o Min. Load % 107,6 108,1 106,4 106,7
50-30 C
Max. Load % 105,0 103,4 103,7 102,8
o
30 C Part. Load % 107,9 107,1 106,8 106,1
Min. Load % 95,0 96,0 94,0 95,0
80-60 oC
Max. Load % 96,9 96,9 96,12 95,94
Circulation pump
with cycle Pipe Datas
control Pipe Pressure Pa 150 135 240 210
Exhaust Gas Max. Load g/sn 22 29 51,5 60
Flow Min. Load g/sn 4,5 5,4 7,5 9,7
Combustion Values
CO 2 Emission Max. Load % 9,3 9,9 9,4 9,5
(G20) Min. Load % 9,8 9,6 9,4 9,2
CO 2 Emission Max. Load % 10,9 11,1 11 11,2
(G30) Min. Load % 10,3 10,5 10,5 10,6
Fan with NOX Emission Max. Load ppm 14 19 14 14
Premix burner with high PWM control (G20) Min. Load ppm 9 10 10 12
combustion efficiency NOX Emission Max. Load ppm 14 19 13 14
(G30) Min. Load ppm 10 12 9 9
o
Pipe Gas Max. Load C 66 68 81 83
o
Temp. (G20) Min. Load C 33 34 38 41

GENERAL SPECIFICATIONS Pipe Gas


Temp. (G30)
Max. Load
Min. Load
o

o
C
C
68
35
71
37
83
40
85
44
Ÿ High Eficiency Al-Mg-Si cast Ÿ Circulation pump with integrated cycle Plumbing Connections
heatexchnager control Heating Cycle Exit inch 1 1/4 1 1/2
Ÿ High combustion efficiency with premix Ÿ Integrated cascade module Heating Cycle Circulation inch 1 1/4 1 1/2
stainless steel burner and fan with Ÿ Display and interference boiler data from Gas Line inch 3/4 1
modulation computer with Siemens control pannel Condensing Outlet mm 25
Safety Disccharge Outlet mm 20
Ÿ Up to %108,1 efficiency value Ÿ Using both NG and LPG
Fresh Air Inlet mm 125 150
Ÿ Up to 256 boilers cascade connection Ÿ Boiler protection with overtemperature Exhaust Gas Outlet mm 80 100
Ÿ Wide modulation range safety thermostad Elektric
Ÿ Suitable solution for high-rise buildings Ÿ Freezing preventation Elektrik Supply V/Hz 220/50
with 6 bar operation pressure Ÿ Space saving with compact dimensions Power Consumption W 275 550
Ÿ High combustion efficiency ,low Ÿ Setting heat cycle operation temperature Other
emission values with PWM control fan betwen 20 °C and 80 °C Cascade Connection PCS 256
Ÿ Silent operation Ÿ Automatic operation according to Freezing Preventation - CURRENT
Hour - CURRENT
Ÿ Equal ageing with specificition of exterior temperature
Holiday Programmer - CURRENT
sequential operation for cascade systems Ÿ Using hermetic or concentric pipe set IP Class - IP 44
Ÿ Internal pipe clack and condensing trap Ÿ Coupled with solar energy system Dimension mm 500x750x470 600x920x470
Ÿ Microprocessor boiler control pannel Ÿ Pool heating function Weight kg 45 84
with digital LCD dispaly and menu Ÿ Easy installation ,using and maintenance Maks. Operation Pressure bar 6
control Maks. Operation Temp. o
C 80

Isı Cihazları Sanayi ve Ticaret Limited Şirketi


Namık Kemal Mahallesi Marmara Caddesi No:74
34702 - ÜMRANİYE / İSTANBUL / TÜRKİYE
Tel: (0216) 369 85 36 - 360 23 40 - 360 71 21

www.daxom.com.tr

Condensing Gas Boiler


Isı Cihazları San. ve Tic. Ltd. Şti, reserves the right to modify the characteristics and
information contained in this document at any time and without advance warning.

You might also like