Professional Documents
Culture Documents
AIR CONDITIONERS
Come home to comfort with LG
Come Home To Comfort
with LG air conditioners
LG makes life good by connecting with the real needs and desires of
our customers
and innovating around them. We passionately believe
in improving the day-to-day lives of Australians via forward-thinking
technological advancement.
COMMERCIAL
32) Cooling Capacity (kW) Heating Capacity (kW)
Indoor Unit Outdoor Unit
STANDARD INVERTER (R32) UU18WR UU24WR Min ~ Rated ~ Max Min ~ Rated ~ Max
B30AWYN7G6 B30AWYU4G6
B36AWY7G6
B36AWYN7G6 B36AWYU3G6
B42AWY7G6
B42AWYN7G6 B42AWYU3G6
B55AWY7G6
B55AWYN7G6 B55AWYU3G6
B62AWY9L6
B62AWYN9L6 B62AWYU7L6
B70AWY9L6
B70AWYN9L6 B70AWYU7L6
6
SINGLE SPLIT KEY FEATURES
CEILING CONCEALED DUCT
SINGLE SPLIT KEY FEATURES
COMMERCIAL
This function easily controls volume of the air by a remote controller. The BLDC motor
can control fan speed and air volume regardless of the external static pressure.
E.S.P. (External Static Pressure) Control
Additional accessories are not required to control air flow.
This function easily controls volume of the air by a remote controller. The BLDC motor can control fan speed and air volume regardless of the
Without
external static pressure. E.S.P.
Additional Controlare not required to control air flow.
accessories E.S.P. Control
Short Piping
Long Piping
Fixture
Fixture
Drain
DrainPipe
PipeSlope
Slope(1/50
(1/50~~1/100)
1/100) rainPipe
DDrain Pipe
Water drainage up to 700mm
Water drainage up to 700mm
450mm
450mm
Flexible
FlexibleDrain
DrainHose
Hose
300mm
300mm
Remote Controller
Thermistor
Remote Controller
(PREMTB001, PREMTB100)
Thermistor Compares temperatures sensed from
(PREMTB001, PREMTB100) different
Compares positions, and automatically
temperatures sensed
Compares temperatures sensedfrom
fromdifferent
selects the
positions, optimum
and temperature
automatically selects the optimum
different positions, and automatically
fortemperature
users for users
selects the optimum temperature
for users
COMMERCIAL
Minimized Height
New mid-static ducts provide ideal solution for installation in limited space.
New mid-static ducts provide ideal solution for installation in limited space.
Minimized Height
8/10kW
8/10kW 12.5kW
12.5kW
New mid-static ducts provide ideal solution for installation in limited space.
380
380
mmmm
8/10kW
298
298
mm
12.5kW
mm
380
mm
270mm
270mm 298
mm
270
270 270
270
mmmm mmmm
270mm
270Inverter
Standard 270Inverter
mm Inverter Conventional
Conventional Standard
Conventional Standard
mm Inverter
ConventionalStandard
Wide Operation
OperationRange
Range
STANDARDINVERTER
INVERTER
Wide Operation Range
R32
R32
STANDARD
R410A
R410A
48 STANDARD
48 INVERTER
48 48 4848
R32 R410A
18
18 1818 1818
48 48 48
18 18 18
-15
-15 -18 -15
-15
-18 -18-18
-20-20
-28
-28
-15 -18 -15 -18kW
2.5~7kW
2.5~7 kW 10~15kW
10~15 kW 20.0/25.0
-2020.0/25.0 kW
-28
Outdoor temperature
Outdoor temperature for
for cooling
cooling operation
operation (°C
(°C DB)
DB) Outdoor temperature
Outdoor temperature for
for heating
heating operation
operation (°C
(°C WB)
WB)
Easy
Easy ServiceService&&Maintenance Maintenance
Users are not required to disassemble the whole panel for maintenance; since panel is divided into 2 components; one for heat exchanger and
Easy
Users
the other Service
arefor
not required The
fan/motor. & canMaintenance
to disassemble
user thedetach
easily wholeand
panel for maintenance;
re-attach since
the filter in the panel islimited space.
available
divided into 2 components; one for heat exchanger and the other for fan/motor. The
Users are not required to disassemble the whole panel for maintenance; since panel is divided into 2 components; one for heat exchanger and
user can easily detach and re-attach the filter in the available limited space.
the other for fan/motor. The user can easily detach and re-attach the filter in the available limited space.
175
LG Ducted Air Conditioners 9
SINGLE SPLIT KEY FEATURES
QuietOperation
Quiet Operation
The
Thenoise
noiselevel
level of
of low static
static ducts
ductshave
havebeen
beenreduced,
reduced, even
even though
though ESPESP
hashas
beenbeen increased.
increased.
27
dB(A)
Flexible Installation
Flexible Installation
Standard Inverter low static duct allows the air intake at the rear or bottom under
installation condition.
Standard Inverter low static duct allows the air intake at the rear or bottom under installation condition.
Conventional
Previous Models StandardInverter
Standard InverterLow
LowStatic
StaticDuct
Duct
Airintake
Air intakeatatthe
theonly
onlyrear
rear Air intake
Air intake at
at the
the rear
rear or
or bottom
bottom
176
10
SPECIFICATION
CEILING CONCEALED
SINGLE SPLIT SPECIFICATIONS
URE) CEILING CONCEALED DUCT (R32)
VERTER (R32)
ESSURE UU18WR
STANDARD INVERTER (R32) UU24WR
4R UBN24R
HIGH STATIC PRESSURE
UBN36R - CM18R / CM24R
78 : www.eurovent-certification.com
12
KEY FEATURES
RESIDENTIAL
*Wi-Fi Dongle Module required. Sold separately. Feature can be accessed using LG SmartThinQ App on
Android (v 4.1 or later) iOS (v iOS9 or later) smartphone. Internet connection required.
Zone Control
It is possible to control up to 8 zones from the premium controller and indicate
a zone name such as Office, Hallway, etc. There are 18 names to choose from.
14
Variable Airflow Technology (VAT)
Variable Airflow Technology monitors the dampers so that only the required
amount of air is discharged into the space. This helps to lower energy consumption
by up to 20%*.
*LG internal test result based on previous 15kW Duct model B55AWYN7G5 vs. new 15kW Duct model B55AWYN7G6.
Premium Controller
Touch Colour Screen Controller*
The LG Individual controller provides intuitive GUI with colour LCD and touch type
interface Main Screen Selection - Choose between detailed and simple formats
to meet your Schedule Control needs - Allows temperture control in conjunction
with the time of day, allowing a customised setting that suits your lifestyle.
Premium Controller
Touch Screen
*Sold seperately.
Weekly Schedule
Energy Monitoring
The Premium Controller provides additional visibility on energy usage
Standard Premium
Controller Controller
Zone Control
The Premium Controller provides control over more zones (eight) and allows zones
to be renamed.
Premium
Controller
16
Filter Clean Information
The Premium Controller provides additional information on how long you have
until you need to clean your filter.
Standard Premium
Controller Controller
Only display
Standard Premium
Controller Controller
- All Lock
It locks all button operation
- On/Off Lock
It locks the On/Off button
- Mode Lock
It locks the operation mode button
-Temperature Range Lock
It is the function that can limit the
range of the desired temperature
Lower limit: 16°C~30°C
Upper limit: 18°C~30°C
Child Lock (All Lock) only
Premium
Controller
30.0˚C 16.0˚C
C 30˚C
C 28˚C
H 20˚C
H 16˚C
Premium
Controller
Ex) When it becomes AM 02:00 on the AEDST start date, the current time changes to AM 03:00,
and when it becomes AM 02:00 of the AEDST end date, the current time changes to AM 01:00.
18
KEY FEATURES SUMMARY
CONTROLLERS
Standard Premium
Category
PREMTB001 PREMTA000
Energy Efficiency
Efficiency Comparison
The energy efficiency increase vs previous LG models (10.5kw), helps to lower
operating costs. (Cooling AEER 14%↑ and Heating ACOP 24%↑)
3.39 3.35
LG Quick Cooling
Pressure control is more efficient* so it takes less time to reach
your desired temperature.
Outlet Temp. (°C)
LG Conventional
Real Pressure
Temperature Control
12°C
Pressure +
Tempertaure Control
2 3 Time (min)
* vs. LG Conventional.
20
Cooling Season - Operation Cost Reduction
The latest Inverter technology from LG helps to lower cooling costs in the summer.
Unoccupied Mode
When you leave your home unoccupied, instead of turning your system off
and letting your home get hot or cold, you can press the dedicated unoccupied
button which will set the room temperature to stay between a range of two
set temperture points. This allows for a quicker return to a comfortable indoor
environment when you return.
I Occupied I I Unoccupied I
AM PM
Cooling
Cooling
In occupied schedule mode, the set range is narrow When you go out, instead of turning off your air
to keep the indoor environment optimised as per conditioning, you can use unoccupied schedule
temperature preference. mode. The set range is wide which allows the
indoor environment to be restored to your
preference quicker, than if you turned off your air
conditioning.
* Home Leave Set Temperature function can only be used in a 2 set control mode.
22
Quiet Mode
Night Silent Operation can reduce noise levels at night time by setting the dip
switch on the PCB of the outdoor unit*.
Noise Level (dB(A))
90
85
Capacity
80
Outdoor Temp.
75
70 Sound Level Up to
10dB(A)
65
60
55
8 hours Mode Start 9 hours 1 Mode End Time
Dry contact
for thermostat
• Operation On / Off
• Thermo On / Off
• Operation mode
(Fan, Heat, Cool)
• Set fan speed
(Low, Middle, High)
3rd party
thermostat
* LG dry contact sold seperately. Please check with your dealer to ensure compatibility between your 3rd party
thermostat and the LG Air Conditioner
24
Compact Indoor Unit
The premium ducted split system has a small chassis. This small split type of
indoor unit helps make it easy to install in narrow and small spaces*.
* Image not to scale. For illustrative purposes only. Consult air conditioning installer for installation options.
Smart Diagnosis*
Monitor the status of your air conditioner and diagnose problems by connecting it
to a smartphone via a SIMs chip*.
Error
Zone
Refrigerant
Leakage 100 90 80 70 60 50 40
CH 35 Amount of Refrigerant
in the system (%)
26
Peak Current Control
Through the peak current control technology, it is possible to save energy and
operational costs.
By limiting to the maximum running current, the air
conditioner can avoid running on the peak current level.
Peak This function can reduce energy cost during peak periods
when electric charge is expensive.
Running Current
• Based on 15 kW model
• LG Internal test result
Time
GoldFin™
The gold-coloured special coating on the fin of the heat exchanger prevents
corrosion, extending the life of the unit.
B30AWY7G6 B42AWY7G6
B36AWY7G6 B55AWY7G6
Note : 1. Due to our policy of innovation some specifications may be changed without notification.
2. Capacities are in accordance with ASNZS3823.1.2
Cooling: - Indoor Temperature 27°C DB /19°C WB Heating: - Indoor Temperature 20°C DB / 15°C WB
- Outdoor Temperature 35°C DB /24°C WB - Outdoor Temperature 7°C DB / 6°C WB
28
SPECIFICATIONS
STANDARD RANGE
B62AWYN9L6
B70AWYN9L6
Note : 1. Due to our policy of innovation some specifications may be changed without notification.
2. Capacities are in accordance with ASNZS3823.1.2
Cooling: - Indoor Temperature 27°C DB /19°C WB Heating: - Indoor Temperature 20°C DB / 15°C WB
- Outdoor Temperature 35°C DB /24°C WB - Outdoor Temperature 7°C DB / 6°C WB
INTERFACE DEVICE
Control Method Objective/Use Unit Name and Model Function Parts Features
• PCB Assembly
• Bracket
To connect
• RS485 Converter • Lead wire: 3ea
Outdoor unit to
PI485 with software • Screw 4EA • 1set/1 Outdoor
CNU or Simple
• For Max.16 Indoor • Tie wrap
PMNFP14A1 Central Controller
• Clamp
• Manual
• PCB Assembly
• Top case
• Bottom case
For connect
• Screw
Indoor unit to • RS485 Converter
Dry Contact • Lead wire 3
other Forced on/ with software • 1set/1 Indoor unit
• Sub PCB set
PDRYCB100 off Controller
(1 leadwire +
1 sub PCB)
• Manual
• PCB Assembly
• Top/Bottom
case
Dry Contact For connect • 1set/1 indoor unit
• Contact signal • Screw
Indoor unit to • 2 Contact points
to air-con signal • Lead wire 3ea
PDRYCB400 other Forced on/ • No need AC input
converter • Sub PCB set
off Controller • Expected temperature
(1 leadwire +
setting is possible
1 sub PCB)
• Manual
*Dred/Dry contact.
30
ACCESSORIES
• Accumulation of total
power consumption
• Indication of current
To Power
power in use
consumption
• Indication of • PDI Assembly
PDI STANDARD Distribution of • 1 PDI / 2 Outdoor
accumulated power Manual
each indoor unit
PPWRDB000 for period
2-port
• Indication of standby
power (option setting)
• Accumulation of total
power consumption
• Indication of current
To power
power in use
consumption
PDI Premium • Indication of • PDI Assembly • 1 PDI / 8 Outdoor
distribution of
accumulated power manual
PQNUD1S40 each indoor unit
for period
8-port
• Indication of standby
power
• Blackout protection