You are on page 1of 8

Data Modul 1

Kelembaban Ruang Uji 53%


Temperatur Ruang Uji 32.8˚C

Tegangan Primer (V) Tegangan Sekunder (kV) Arus Primer (A)


25 13.56 0.8
50 26.2 1.8
75 39.12 2.8
100 52.51 3.9
Data Modul 2
Kelembaban Ruang Uji 55%
Temperatur Ruang Uji 32.7˚C

Sphere Gap Distance (mm) Theoritical Breakdown Voltage (kV)


10
20
30
40
Observed Breakdown Voltage (kV) Tegangan Primer (V)
20.72 43
41.87 83
60.04 120
74.45 145
Data Sub Modul 2 Jarum Alumunium
Kelembaban Ruang Uji 56%
Temperatur Ruang Uji 32.9˚C

Sphere Gap Distance (mm) Theoritical Breakdown Voltage (kV)


5
10
20
30
40

Data Sub Modul 2 Jarum Tembaga


Kelembaban Ruang Uji 55%
Temperatur Ruang Uji 33.1˚C

Sphere Gap Distance (mm) Theoritical Breakdown Voltage (kV)


20
30
40
Observed Breakdown Voltage (kV) Tegangan Primer (V)
2.93 14
6.83 16
10.93 20
21.95 42
23.57 45

Observed Breakdown Voltage (kV) Tegangan Primer (V)


17.09 33
21.36 42
25.56 52
Data Modul 3
Kelembaban Ruang Uji 55%
Temperatur Ruang Uji 33.5˚C

Tegangan Primer (V) Tegangan Sekunder (kV) Arus Primer (A)


25 33.41 0.2
50 63.74 0.3
75 96.73 0.5
100 126.51 0.7
Data Modul 4
Kelembaban Ruang Uji 54%
Temperatur Ruang Uji 33.8˚C

Sphere Gap Distance (mm) Theoritical Breakdown Voltage (kV)


10
20
30
40
Observed Breakdown Voltage (kV) Tegangan Primer (V)
45.1 36
105.63 83
128.86 104
175.19 140

You might also like