L55EX/SA-x-xxx
Before installing or operating read this manual carefully and retain it for future
reference.
NOTICE
This instruction manual provides information about installation, operation and maintenance of the
L55EX/SA-x-xxx lighting fixture.
The manual has been written for installation, user and first line maintenance personnel.
For information about required adjustments or repair not instructed in this manual, contact Orga's
service support department.
Orga. B.V.
The integrity and reliability of navigational aids system are dependant on the use of Orga parts and components.
To ensure the optimum performance and reliability of your Orga system, it is strongly advised that only
components manufactured by Orga are used.
The use of foreign parts which are not approved by Orga will invalidate the warranty.
DISCLAIMER
While every effort has been made to provide a complete, up-to-date, accurate manual, no liability claims for
damages resulting from any errors or omissions in this manual will be accepted by Orga.
COPYRIGHT
THE SUPPLIER
This equipment has been sold to you by Orga. The equipment has been manufactured by Orga.
Orga warrants that all products conform to the Orga specifications and are free from defects in material and
workmanship at time of shipment. Orga will repair or replace (at its option) F.O.B. factory, any parts or materials
found to be defective when properly used for their intended purpose. Such obligation shall be limited to parts
returned to the factory for inspection, properly packed and expenses prepaid, within twelve months of date of
shipment and provided that inspection shall satisfactorily indicate the defects.
In no event shall Orga be liable for consequences, special damages caused during transportation, installation,
adjustments or other expenses, which may arise in connection with its products or parts.
In no case are parts or equipment to be returned without first obtaining the written permission of Orga.
This navigational aids system is tested at the factory and operated satisfactorily. If connected according to the
Interconnection Diagram as part of the drawings, the system will operate as designed.
This warranty is to be declared null and void if Orga’s inspection indicates that parts or equipment have been
installed incorrectly, adjusted, rewired, modified, tampered with, etc., specifically, but not limited to the following:
The warranty stated herein is exclusive. There are no other warranties, either expressed or implied, beyond
those set forth herein.
Orga does not assume any other obligation liability in connection with the sale or use of these products.
Orga’s liability on any claim of any kind including negligence for loss or damages arising out of or connected
with the manufacture, sale, delivery, repair or use of any equipment or services provided by Orga shall in no
case exceed the price allocable to the item or service, or part, which gives rise to the claim.
6 EC DECLARATION............................................................................................................................................... 12
This instruction manual provides information about installation, operation, and maintenance of the
L55EX/SA-x-xxx-xx lighting fixture.
TYPE DESIGNATION:
L55 XX –X – XXX
EX (Hazardous area)
SA (Safe area)
G (green lens cover)
R (Red lens cover)
120Vac/dc
230Vac/dc
DATASHEET
Type : L55EX/SA-x-xxx
Make : Orga
Standard (L55EX) : Cenelec EN 50014/17/19
Protection (L55Ex) : II 2 G Eex qe II T3
Certificate (L55Ex) : 02ATEX2349 (KEMA)
Zone : 2
Ingress protection : IP66
Base material : Chromatised cast light alloy provided with polyurethane coating
Lens material : Poly Carbonate, highly impact and UV resistant
Hardware : Stainless steel
Light source : 55W QL long life Induction Lamp
Light character : Steady burning
Light colour : Green or Red
Light source life expectancy : See diagram below
Vertical light distribution : In compliance with CAA and ICAO requirements
Horizontal light distribution : 360°
Operating voltage : 230 VAC/VDC (190V - 255V) or 120 VAC/VDC (108V - 132V); 55W;
50/60Hz
Operational temperature range : -20°C up to +40°C
Earth connection : Internal and external
Junction box material : GRP
Number of cable entries : 2
Dimension of cable entries : M25, provided with one GRP gland and one blind plug
Outer dimensions (lxwxh) : Approx. 300 x 268 x 242 mm
Mounting hole dimensions : 3 holes Ø 9 at 246 mm circle
Weight hazardous area version : Approx. 8,3 kg
Weight safe area version : Approx. 6 kg
Three equally spaced 9 mm fixing holes are provided, to accept M8 fixing bolts, arranged on a 246 mm pitch
circle diameter.
The cable connections are made on the terminal block mounted inside the fixture’s junction box.
The terminals are suitable to accept max. 4mm2 wires.
Voltage drop calculations shall be made by the installer in order to determine the proper size of supply cable.
Voltage drops of more than five percent should be avoided. In case the size of cable used does not fit in to the
equipment, a separate junction box can be supplied.
Note: If lantern does not operate correctly, proceed with 3.5 trouble shooting.
1. The cable entry devices and blanking elements shall be certified in type of explosion protection EEx e,
suitable for the conditions of use and correctly installed.
2. Only fixed shifted cables may be imported. Operator has to guarantee an appropriate strain relief.
3. To comply with the EMC guidelines, shielded cable is required.
4. Before closing the dome, please make sure gasket is fitted and threading is greased sufficiently. Grease with
Copa slip or Molykote longterm W2.
5. Terminals suitable for looping upto 4mm² conductor.
6. Internal and external earth connection provided.
7. The enclosure may only be opened under non-hazardous conditions.
LAMP INSPECTION
The L55SA/EX-x-xxx helideck perimeter light is equipped with a long life QL lamp. It therefore does not need
inspection of the lamp. The lamp cannot be exchanged by the platforms personnel. An exchange program for
these units is available.
EC–DECLARATION OF CONFORMITY
Wij
We
O R G A B.V.
Leveranciers naam / Supplier’s name
EMC-RICHTLIJN: 89/336/EEG
EMC-DIRECTIVE : 89/336/EEC
II 2 G EEx qe II T3 0344
In overeenstemming met de volgende (geharmoniseerde) norm(en)
In accordance with the following (harmonized) standards
J.P. Stock
Schiedam, 17/05/2005 Certification & Quality Manager
Plaats en datum van uitgifte / Naam en handtekening of gelijkwaardig waarmerking van de gemachtigde persoon /
Place and date of issue Name and signature or equivalent marking of authorized person
Wij
We
O R G A B.V.
Leveranciers naam / Supplier’s name
Strickledeweg 13
3125 AT Schiedam
Postbus 3046
3101 EA Schiedam
Adres / Address
L55SA
Naam, type of model, batch- of serienummer, mogelijk herkomst en aantal / Name, type or model, batch or serial number, possibly sources and number of items
EMC-RICHTLIJN : 89/336/EEG
EMC-DIRECTIVE : 89/336/EEC
LAAGSPANNINGS-RICHTLIJN : 73/23/EEG
LOW VOLTAGE DIRECTIVE : 73/23/EEC
J.P. Stock
Schiedam, 13/05/2005 Certification & Quality Manager
Plaats en datum van uitgifte / Naam en handtekening of gelijkwaardig waarmerking van de gemachtigde persoon /
Place and date of issue Name and signature or equivalent marking of authorized person