The Intrinsic Safety Barrier Module is designed around a standard DIN Rail mounting (Type EN 50 022, 35 mm X 7.5 mm) for easy installation in
standard enclosures. The barrier has a non-incendive rating and can be installed in Class I, Division II areas.
EM DR1 IS 5 RTB
TYPE:
EM = Electronic FUNCTION: OUTPUT TERMINATION:
Module, IS = Intrinsically Safe RTB = Removable Terminal Block
DIN Rail mount
PACKAGE STYLE: OUTPUT VOLTAGE SUPPLY VOLTAGE/OUTPUT:
DR1 = 114.5 mm H X 99 mm D X FROM ENCODER: 24V/V, 24 VDC max, Vout = Vin
22.5 mm W 5 = 5 VDC 24V/5, 24 VDC max, Voutt = 5 volts
24V/OC, 24 VDC max, Vout = Open Collector
Dimensions
114.5 mm
ON
A 99 mm
B
Z
22.5 mm
Specifications Certifications
The BEI Intrinsic Safety Barrier has the following
HAZARDOUS AREA NON-HAZARDOUS AREA certifications allowing intrinsically safe encoders to be
OR CLASS 1, DIV 2
GROUPS A,B,C,D installed in the following hazardous locations consistent
INTRINISCALLY NON HAZARDOUS
SAFE TELEMETERING H S with the encoder specifications:
A A AREA APPARATUS
EQUIPMENT
Z F
SUPPLY A 5VH VS E POWER EN 55011 and EN 61000-6-2
VOLTAGE ±5% POWER
R SUPPLY
OV D 0VH ISOLATION OV Z OV
O O
U N U.S. Standards Class I, Group A,B,C & D;
S
E Class II Group E, F & G
A A A A
Z
A O A A A CENELEC/ATEX EEX ia IIC T4
OUTPUT B N B B B
SIGNALS B
E B B B
Z Canadian Standards
Z Z Z
Z Z
C Class I, Zone 0, Group IIC