You are on page 1of 5
anniogo1e Extemal alarm cabling Single RAN, Rel. SRAN 17A, Operating Documentation, Issue 02 (HTML) > Install > BSC/TCSM and meBSC > Connector Panels and External Cables in Flexi BSC and TCSM3i > Roof panel with LAN, LPT/VDU, and synchronisation and alarm interfaces (CPRJ45-A) External alarm cabling ‘The CPRUJ45-A panel accommodates two D25 connectors, one (21) for external alarm inputs and one (22) for ‘external alarm outputs. There is also one D9 connector (23) for voltage and current-controlled alarm inputs. The CPRJ45-A is located in the middle hole at the equipment cabinet top. The external alarm cabling connectors are shown in the following table. Tbe steal alarm cab connsctors inthe CPRIAS-A pal ‘Connector ‘cable, Connector ‘able ype 2 (VR, 25-pin Dzennecior, male. Ober | Mllioxs SH AWG26ITS pars ‘wo 25-pn D-zonnactrs, mal, | Maliexa SH ANIG2ES pe rion partly conecod 2 (CY @-pin-connecor male, Other | Milexd SH AWG2608 pare External alarm output signals - CNDE cable External Alarm output signals at the CPRJ45-A panel and configurations of CNDE cable with D25 connectors are presented in the following table. abi ‘Alarm signals athe CPRIAS-A pane and pin conguation of CNDE cable with B25 connectors Pin ‘Alarms ‘eNDE. ‘eNDE ‘ene GPREA pane, [ Compactor 22(EXT [Connector | Colour Connector? 7 E08 7 Buswnte | 9 (EXAUA) 2 roy 2 waietaive | 3(EXAUA) a roms a ‘rangelnte | S(EXAUA) a ro 4 WoitiOrange | 7(EXALA) 5 EOE 3 Creewwnte | (EXAUA) 6 EOS @ WatelGrean | *1(EXAUA) 7 ros 7 BrownWnte | 13 (EXALA) @ REO a WattBrown | °S(EXALA) @ roy ° Creyimee | S7(EXADA) 0 E08 10 WatetGrey | S9(EXAL-A) * ror * Bletvatow | 21 (EXALA) 2 2 YatowBiue | 23(EXAL-A) 3 " Orangetvaow [ne 1 ror Yelowiorarge | re 6 net © CGreenvenon [ne 6 6 YatowiGreen [ne 7 7 Browivolow [re 8 8 YelowBrown | ne 18 - 8 Groyelow [ne hitp:acathost:1024informationbrowseriindexisp 18 auioro1e External alarm cabling Pin ‘CNDE: ‘eNDE ‘ene (CPRIAS-A pan ‘Connector | Colour ‘Connector? 2 2 YatowiGrey [ve a a BueWvelt [ve 2 2 Votive [ve 2 : @ Orangetaat [ve 2 > a ViolevOrange | ne % ND Greanolt | 2,488.10, 12, ali, 10,2012, : ne VilsiGreen [ne 7 ne Vielen | ne ne Creyekt [ve me WowuGey |e 7 25comecor | Sereenwra | Connector ood Hoos eno CConnecorhaod | Gableshield | Connector ood "ABO = Exteral alan output gral ‘Alarms AEOO-AEO11 are connected directly to the EXAU-A with cable CNDE. All alarms AEOO-AEO15 can be connected to the crass connection (DDF) with cable CNDE (the other cable end, connector 2, cut off. Four lengths of CNDE cable are available (ID codes presented): © 5m: C106809 + 10m: 106819 © 20m: C108435 © 60m: C107185 Voltage controlled external alarm inputs - alarm cable CYR abe Signals. on panel connector 2 (Valoge and curen-conkllad AL inputs, AE) Pin: ‘lars ‘arm cable GYR; | Alarm cable CYR; {GPRIAS.A panel, | Connector71 Vonage | Pin in Connector | Colour ‘connector 24 Sn current-cont Ex at npury a nee 2 ‘Oranges ‘ ror 4 WntelOrange 3 ne ¢ “Greenhite . ror é WnteiGreen 7 Aas 7 ‘rownitnte @ aa? ® Whiten @ ror ° ‘creyite hitp:acathost:10240informationbrowseriindexisp 215 auioro1e External alarm cabling Pin; ‘Alarms ‘Alarm eable CYR; | Alarm cable CYR: ‘GPRIES-A panel, | Connector21 Voltage | Pin in Connector? | Colour ‘connector #4 nears 0 Ee WinteiGrey " AIO 7 ‘Blvenvolow 2 nei 2 Yelowaive 3 nen 2 rangevotow * nen ‘Yelowiorange| 5 nei ‘Greonivalow | 16 ners 6 ‘YetowiGreen a 12 z ‘BusiPape 2 neat 2 Purples 2 rors 2 (OrangePupie 7 Ai m Purplelorange @ ho 2 Greenivaet VialavGreen 7 Brownivot 7 Vilavrown 2 ‘ryivoet 7 VoleuGrey 25 Comectorhoed | Sereen wre Hoos cho ‘Connectorhood | Cable shel Note tage coiolod external alarm inp signal Voltage controlled external alarm input signals are connected from MDF to CPRJ45-A panel using CYR cable. Three lengths are available (CS codes presented): © 35m: CS73131.35 + 50m: CS73131.50 * 70m: 0873131.70 24 external voltage controlled alarm inputs can be connected to Flexi BSC using the CYR cable. Current-controlled external alarm inputs Tab Signals on panel comector 23 (curont-antole ALS inputs) ‘Connector 23 (Voltage | Pinin Connector | Colour ‘connector 23 Sind curren-cont Bera INPUT) 7 NSO 1 ‘Buen hitp:acathost:1024informationbrowseriindexisp auioro1e External alarm cabling Pin; ‘Alarms ‘Alarm cable CYV; | Alarm cable CY, ‘GPRIEE-A panel, | Connector 23 Votage | Pin in Connector? | Colour ‘connector #3 nears 2 Asi 2 Wnteve a Ase a ‘ranges 4 Ase 4 WintelOrange 5 Ase 5 “Greenthte a Ass 6 WinterGreen| 7 ‘rangevotow Yeuowiorange| ‘@Comactorhoed | Sereen wre eos eno ‘Connactarnood | Cable shea [ALS = eurrentconrled extemal alarm input nal Current-controlled external alarm input signals are connected from MDF to CPRJ45-A panel by using the CYV cable. ‘One length of the cable is available (ID code presented): 20 m (C7239). ‘Six external current-controlled alarm inputs can be connected to the Flexi BSC by using the CYV cable. Connections to external alarm unit EXAU-A A special lamp panel (External Alarm Unit EXAU-A) can be employed for the indication of alarms. Indicator lights have been connected to six incoming alarms of EXAU-A. In the EXAU-A, a buzzer that can be connected to any alarm is available. Using CNDE cable, the EXAU-A can be directly connected to D25-connector 22 of the CPRJ45-A panel or through the digital distribution frame (DDF or cross connection) that connects the alarm cables coming from the network element. When the alarms are routed through the digital distribution frame (ODF) the CNDE cable is cut and the wires are connected to the cross connection, ‘The complete CNDE cable is available in lengths 5, 10, 20 and 50 m. The maximum distance between the EXAU- A panel and the network element equipment it is connected to is 200 m (B50ft.) General requirements for external alarm cable CNDE are presented in the following table. Tabi: (General requraments for extemal lam cable CNDE ‘abe ype: {2 pars, weld, eile, cross scion OA mm2, Mixa SH ANG2BI8 ‘Cable comecior: 25a D connector (maeonate) ‘The EXAU-A has also a second D25 connector which makes is possible to chain several alarm units so that the alarms can be displayed on more than one unit. See figure /nsiallation of the EXAU-A; mounting on the wail, cabling, and setting the buzzer jumpers. hitp:ocathost:1024\informationbrowseriindexisp 45 auioro18 External alarm cabling Figure: Installation of te EXAU-A: muting onthe wa, cabling, and sting the buzzer jumpors sw BUZZER SELECT caution | | a.oo. dS FE a 2 + | | aos jee | | ace 2 a a oO le 6 ° PCE a Cover 8 o o 6 Buzzer Reset 2 8 Slant Mode The colours of the alarm signals are shown in the following table. ‘colour Postion Sian ‘arm ea (Uppemost (a amt Yellow @ won Tam reen o (aon) ‘aa Fed @ aim ‘arm Yalow @ aoe) ‘arm ‘ue (@ lowermost (a5) Tarn 6 Related resources Parent topic: Roof panel with LAN, LPT/VDU, and synchronisation and alarm interfaces (CPRJ45-A) hitp:ocathost:1024\informationbrowseriindexisp

You might also like