You are on page 1of 2

CO2-2000

CO2-2000 Carbon Dioxide Detection & Control Unit


December 2011

CARBON DIOXIDE DETECTOR FOR INDOOR AIR QUALITY MONITORING

Features: Applications:

Two Standard Ranges: Working environments


0-2000PPM and 0-5000PPM
Conference rooms
Digital Readout of PPM values
Greenhouses
SPST Relay output contact at a
user adjustable setpoint Workout room/Gym

4-20mA output HVAC/Ventilation

This state-of-the-art instrument The CO2-2000 monitor provides a Unlike other models, its simple user
measures Carbon Dioxide (CO2) continuous, accurate reading of interface has no complicated menus:
concentrations in the parts per million indoor CO2 levels, making it easy to all maintenance and calibration
(PPM) range and is ideal for maintain an optimum level of fresh operations are easily performed even
applications ranging from conference air. on units with no LCD display
rooms to home gyms.
The CO2-2000 is easy to install and The CO2-2000's versatility is
Fresh air contains 350-400PPM CO2. support. Measurement output is via enhanced by options to satisfy most
Human respiration and combustion a 4 - 20mA current loop or a 0-10V applications. The clear, bright 0.4"
by-products from furnaces, fireplaces interface. A completely isolated high LCD display option is readable
and household appliances can easily power supply eliminates any ground from any angle for installations where
raise indoor levels above 2000PPM. loop or electrical interaction problems local annunciation of the CO2
With your CO2-2000 you can watch when multiple units are connected to concentration is desired. For direct
CO2 levels rise as people enter a the same controller. Low power control applications the relay option
room. consumption makes the CO2-2000 can be configured to open or close
perfect for battery-operated or other above the setpoint and is easily
According to the National Institute of power-sensitive applications. adjusted in the field. For plenum
Occupational Safety and Health, sampling requirements, the popular
increased levels of CO2 may The CO2-2000's single gas duct option is easy to install.
contribute to "Sick Building verification makes field calibration a
Syndrome" and symptoms such as snap, and its superior design means
hyperventilation, headache, significantly longer calibration
dizziness, shortness of breath, and intervals.
drowsiness.

1
CO2-2000 Carbon Dioxide detection & control unit Technical Data:
Operating principle : Non-dispersive infrared (NDIR)
Gas sampling method : Diffusion (Duct mounting kit optional)
Measurement range : 0-2000PPM (0-5000PPM optional) Typical specifications
Power requirements : 18 - 30V DC or 18-30Vrms AC
Supply, install and connect at
(110V AC Transformer available)
locations shown on plans a required
Measurement accuracy : ± 5% of reading number Acme CO2-2000 CO2
Repeatability : ± 20PPM Detection Units.
Recommended calibration : 2 years
Units shall be state-of-the-art solid
Warm up time : 1 minute
state instruments measuring CO2
Power consumption : Less than 1 watt concentrations in a range of
Operating temperature range : 0-50º C (32-120º F) 0-2000PPM (or optionally
Operating humidity range : 5-95% RH, non-condensing 0-5000PPM ).
Voltage output (linear) : 0-10V DC full scale standard - field adjustable
The Unit shall employ a Non-
Current output (linear) : 4-20mA (Loop : 400Ω maximum) Dispersive Infrared sensor with no
CO Sensor/Transmitter
Optional LCD display : 4 digits, 0.4” high
Cat. No.: CO-ST moving parts.
Optional relay setpoint range : 0 to full scale
Standard unit shall be for diffusion
Optional relay contact rating : 3A @ 24V AC
type monitoring. OPTION: Unit
Case Dimension : 135mm x 135mm x 35mm (5.25” X 3.25” X 1.4”) shall be provided with a duct
Enclosure material : Satin finish, high impact plastic mounting kit should this method of
monitoring be desired.

The unit shall have an accuracy of


Typical wiring diagram no greater than ±5% of reading and
shall require calibration only at a
5-year interval.

The unit shall have a 4-20mA


SCREW current and a 0-10V DC voltage
ACCESS output linear over its entire
measuring range.

The unit shall have a normally open


OUTPUTS WIRE (N.O.) relay output contact factory
-3 ACCESS 1+ POWER IN set to close at 1000PPM. The relay
4-20 mA shall have a contact rating 3A @
+4 2- 24V AC or DC
N.O. contact 24V AC.

The CO2-2000 shall be powered


from a fused 24V AC circuit and
shall not consume more than 1 watt
SCREW at full load.
ACCESS

In the U.S.A. In Canada Represented by:


ACME ENGINEERING PROD. INC. ACME ENGINEERING PROD. LTD.
Trimex Ind. Bldg., PMB #10 5706 Royalmount Ave.,
2330 State Route 11 Montreal, Quebec
Mooers, N.Y. 12958 H4P 1K5
Tel. : (518) 236-5659 Tel. : (514) 342-5656
Fax : (518) 236-6941 Fax : (514) 342-3131
E-mail : info@acmeprod.com Internet : www.acmeprod.com
The information provided by this bulletin is a general description of ACME UNITS. All specifications are subject to change without notice. 2
Installation, maintenance and other instructions provided with the equipment shall be closely followed by installers, owners and users.