Battary Panel Fot Sailor 4000 GMSSB
Battary Panel Fot Sailor 4000 GMSSB
Any responsibility or liability for loss or damage in connection with the use of this product and
accompanying documentation is disclaimed.
The information in this manual is furnished for informational use only, is subject to change
without notice, may contain errors or inaccuracies, and represents no commitment whatso-
ever.
INTRODUCTION ................................................ 5
General Description ............................................ 5
Technical Data ................................................... 7
OPERATION ...................................................... 9
INSTALLATION ............................................... 10
Wiring principle ................................................. 10
Outline and Mounting Plan ............................... 11
Connectors Location ......................................... 11
Adjustments ...................................................... 12
Disassemble for jumper setting ........................ 14
Jumper Settings ............................................... 15
BATTERY PANEL 3
4 BATTERY PANEL
INTRODUCTION
INTRODUCTION
GENERAL DESCRIPTION
The Battery Panel is intended for installations with one or two batteries
(determined by internal jumper setting) and one or two battery chargers.
It contains separate alarm lamps for indication of high/low battery volt-
age for each battery, and separate alarm lamps for indication of AC
supply failure for each battery charger. With a push button switch it is
possible to switch the panel meters between monitoring battery 1 and
battery 2 in two battery installations.
The Battery Panel include dimmer, mute and test functions. The dis-
plays and keyboard are backlight illuminated.
BATTERY PANEL 5
INTRODUCTION
The voltage and current meters are supplied from the battery itself and
will operate down to a battery voltage of 10 V. The audible alarm and
visual indicators are supplied from the + 24 V DC of the AC Power
Supply/Charger allowing low voltage alarm in case of battery failure.
6 BATTERY PANEL
INTRODUCTION
TECHNICAL DATA
AC-alarm
Input type selectable between relay contact or voltage input.
Relay contact:
“No Alarm” ~ open circuit
“Alarm” ~ short circuit
(Open circuit voltage: 1.2V, Short circuit current: 6mA)
Voltage input:
No Alarm” 24V DC nom.
“Alarm” 0V DC
(Input current at 24 V DC: 6mA)
BATTERY PANEL 7
INTRODUCTION
Voltmeter
3 ½ digit
Resolution: 0.1V
Accuracy: ±4% typically
Measuring range: +10 to +40V
Sensitivity: 1V/V
Current Meter
3 ½ digit
Resolution: 0.1Amp
Accuracy: < ± 10% of meter reading
Measuring range: ±200 Amp
Sensitivity: 100µV/Amp
8 BATTERY PANEL
OPERATION
OPERATION
4-0-34932
BATTERY PANEL 9
INSTALLATION
INSTALLATION
WIRING PRINCIPLE
4-0-34928A
Battery Panel
X 1 or X 2 Designation Description
D-Sub 9 way
1 +VBAT Voltmeter input and supply
Current meter input,
2 +SHUNT
reference
3 -SHUNT Current meter input
4 -VBAT Voltmeter input, reference
5 AC ALARM V AC alarm input, voltage
6 AC ALARM R AC alarm input, relay contact
7 AC ALARM C AC alarm input, common ref.
8 24V D C + Supply voltage input for
9 24 V D C - alarm and light
10 BATTERY PANEL
INSTALLATION
3-0-33418
Dimensions are in mm.
Tolerance: +/- 1
Weight: 1.3 Kg
1) Space for cable entry: min.100
CONNECTORS LOCATION
4-0-34931
BATTERY PANEL 11
INSTALLATION
ADJUSTMENTS
4-0-34930
12 BATTERY PANEL
INSTALLATION
BATTERY PANEL 13
INSTALLATION
14 BATTERY PANEL
INSTALLATION
JUMPER SETTINGS
5 6
R84
S7 S3 S6 S4
R83
R94
S8
S5
R95
7 8
4-0-34934
BATTERY PANEL 15
INSTALLATION
16 BATTERY PANEL