You are on page 1of 2

CMi4110 English

Integrated MCM for L+G UH50, LoRaWAN


Evaluation samples
Introduction The table below provides a description of all settings
CMi4110 is an integrated solution for L+G UH50 meters. For a configurable via the LoRaWAN MCM mobile application. For
complete description of the product or for information in other more information, please refer to the seperate LoRaWAN
languages, visit the Elvaco AB website, http://www.elvaco. MCM mobile application manual.
com.
ID Description NFC Downlink
Config Configuration mode of CMi4110.
1. Meter interface X
source
2. Push button Power mode Current power mode of CMi4110 X
3. Green LED (passive or active).
4. Red LED Activation Sets the way CMi4110 joins the X
type LoRaWAN network (OTAA or ABP).
5. Tamper switch
(optional) Device Unique CMi4110 device ID. X
identification
6. External antenna
connector Application Application server ID. X
(optional) identification

7. LoRa antenna Application Application key used to derive


key Network session key and X
8. NFC antenna Application session key (only used
Mounting in OTAA mode).
CMi4110 is mounted in the right module slot of a L+G UH50 Device CMi4110 device address. X
meter with software version 5-15 or higher. address
IMPORTANT Network Network session key. Generated
• Electrostatic-sensitive device. Please session key automatically when using OTAA X
observe the neccessary ESD protective mode. Registered manually when
using ABP mode.
measures when installing the MCM
Application Application session key. Generated
session key automatically when using OTAA X
Antenna mode. Registered manually when
using ABP mode.
CMi4110 uses an internal PCB antenna, designed for high
performance. Message Format of CMi4110 messages X X
format (normal or compact).
Set date and Specifies whether to implement
Activation time date and time settings of the phone X X
Upon delivery, CMi4110 is set to passive mode, which means in CMi4110 (on or off).
no messages will be transmitted from the MCM. There are Approved Tx Specifies whether to use Elvaco Tx
two ways to activate the product: settings default setting (on or off).

1. Press and hold down the push button (2) for at least 5 ADR Adaptive Data Rate (on or off). X
seconds until the green LED responds. Data rate Current data rate of CMi4110 X
2. Via the LoRaWAN MCM mobile application. Start the (DR0-DR7).
mobile application, go to Apply mode and set the Tx interval The number of minutes between
Power mode to “Active”. Place the phone on the right each CMi4110 data transmission X X
side of the meter and press Apply settings. (1-1440).

Upon start-up, the green and the red LEDs will lighten up
for one second. The MCM will thereafter attempt to join the safety
LoRaWAN network. Each attempt is marked by a short blink of The warranty does not cover damage to the product caused
the green LED. Upon a successful join attempt, the green LED by usage in any other way than described in this manual.
will lighten up for 2 seconds. Elvaco AB can not be liable for personal injury or property
damage caused by usage in any other way than described in
When activated, CMi4110 will initially begin transmitting meter this manual.
data every minute in order to set the right data rate. After 10
minutes, the MCM will start using its configured Tx settings. Contact information
Configuration Elvaco AB Technical support:
CMi4110 settings can be configured via NFC by using the Phone: +46 300 434300
LoRaWAN MCM mobile application. Set Config source to E-mail: support @elvaco.com
select how you want to implement the new MCM settings: Online: www.elvaco.com

• Empty: All settings are configured manually.


• Inspect: Settings from the last read CMi4110 is
implemented.
• Server file: Settings are implemented via a configuration
file.
After selecting your desired confguration, place the phone on
the right side of the meter and click Apply settings. Three
quick vibrations indicate that new settings have successfully
been implemented.
Technical specifications
Mechanics
Protection class IP54 (EN 60259)
Dimensions (w x h x d) 80 x 38 x 23 mm
Weight 35 g
Mounting In Landis+Gyr UH50 right
module slot
External antenna connector SMA female
(optional)
Electrical connections
Supply voltage Internal meter battery
Electrical characteristics
Nominal voltage 3.0 - 5.0 VDC
Power consumption (max) 40 mA
Power consumption (sleep mode) 2.2 µA
Power consumption (avr) TBD
Environmental specifications
Operating temperature 5 - 55 ºC
Operating humidity 0 - 93 % RH, No condensation
Operating altitude 2000 m
Pollution degree Degree 1
Usage environment Indoors
Storage temperature -20 - 60 ºC
Radio characteristics
Output power 14 dBm
Receiver sensitivity -135 dBm
LoRaWAN characteristics
Activation ADP or OTAA
Data rate DR0-DR7
Bands EU/US/India/Pacific
User interface
Green LED Status
Red LED Error
Push button Start-up
Configuration NFC (LoRaWAN MCM mobile
application) or downlink data

You might also like