General Description:
18 AWG solid bare copper conductor, foam FEP insulation, Duobond® IV Quad shield (60% and 40% braid
coverage), Flamarrest® jacket.
Usage (Overall)
Suitable Applications: Satellite Dish, KU Band
Insulation
Insulation Material:
Insulation Material Dia. (in.)
FFEP - Foam Fluorinated Ethylene Propylene .170
Outer Shield
Outer Shield Material:
Layer # Outer Shield Trade Name Type Outer Shield Material Coverage (%)
1 Bonded Duofoil® Tape Bonded Aluminum Foil-Polyester Tape-Aluminum Foil 100
2 Braid AL - Aluminum 60
3 Duofoil® Tape Aluminum Foil-Polyester Tape-Aluminum Foil 100
4 Braid AL - Aluminum 40
Outer Jacket
Outer Jacket Material:
Outer Jacket Trade Name Outer Jacket Material
Flamarrest® LS PVC - Low Smoke Polyvinyl Chloride
Overall Cable
Overall Nominal Diameter: 0.248 in.
EU CE Mark: Yes
Page 1 of 3 08-26-2016
Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
Flame Test
UL Flame Test: NFPA 262
Plenum/Non-Plenum
Plenum (Y/N): Yes
Nom. Inductance:
Inductance (µH/ft)
.097
Nominal Delay:
Delay (ns/ft)
1.24
Nom. Attenuation:
Freq. (MHz) Attenuation (dB/100 ft.)
1.000 0.400
10.000 0.700
50.000 1.600
100.000 2.100
200.000 3.000
400.000 4.300
700.000 6.000
750.000 6.300
900.000 7.000
1000.000 7.500
1450.000 9.300
1800.000 10.400
2250.000 11.900
2500.000 12.700
3000.000 14.300
Sweep Test
Sweep Testing: 5 MHz - 3 GHz
Page 2 of 3 08-26-2016
Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
Notes:
C = CRATE REEL PUT-UP.
Page 3 of 3 08-26-2016