You are on page 1of 2

DESIGN OF BOLTED CONNECTIONS

Input Properties
Bolt Type A325
Bolt Description Threads are not excluded from shear plane
Bolt Diameter 30 mm
Nominal Tensile Strength, Fnt 620 MPa
Nominal Shear Strength, Fnv 372 MPa
Tb 326 kN
Friction Factor 0.35
Du 1.13
hf 1
ns 1
Yield Stress, Fy 248 MPa
Ultimate Stress, Fu 400 MPa
Beam Web Thickness 10 mm
Gusset Plate Thickness 16 mm
Input Loads Tension Shear
Dead 26.415 kN 165.464 kN
Live 11.45 kN 64.133 kN
Seismic 14.438 kN 3.643 kN
Load Combinations (LRFD) Tension, Tu Shear, Vu
1.4D = 36.981 kN 231.6496 kN
1.2D + 1.6L = 50.018 kN 301.1696 kN
1.2D + 1.0L = 43.148 kN 262.6898 kN
1.2D + 1.0E + 1.0L = 57.586 kN 266.3328 kN
0.9D + 1.0E = 38.2115 kN 152.5606 kN
Maximum Pu = 57.586 kN 301.1696 kN
Design Analysis
Number of Bolts (nb), Bearing = 2 pcs
Number of Bolts (nb), Slip Critical = 4 pcs
Use No. of Bolts = 4 pcs
Check for Tension 569.2956516 MPa OK!
Check for Shear 788.8539153 kN OK!
Check for Bearing 1152 kN OK!
Check for Block Shear
Check for Yielding and Fracture
2.4dtFu 1.2lctFu

You might also like