NAVIGAT 2200
For third-party copyright content in relation to the document present, see the third-party copy-
right information chapter in this manual.
Sperry Marine, with major engineering and support offices in New Malden, England, and
Hamburg, Germany, is part of the Northrop Grumman Navigation & Maritime Systems Division
N&MSD.
Revision Record
Contents
Safety Information
Safety Notice Conventions.......................................................................... v
General Safety Information ........................................................................ vi
Chapter 1: Introduction
1.1 General Information.................................................................................. 1-1
1.2 System Requirements .............................................................................. 1-1
1.3 NAVIGAT 2200 Upgrade Kit...................................................................... 1-2
1.4 Connection Schematics............................................................................ 1-4
Appendix
1-3
73520/A NAVIGAT 2200
1-4
NAVIGAT 2200 5023-0125-02/A
Safety Information
v
5023-0125-02/A NAVIGAT 2200
Note At the end of the software update procedure, the service personnel is
obliged to send the log file and software update test protocol back to:
Northrop Grumman Sperry Marine B.V. (Representative Office)
Woltmanstr. 19 • D-20097 • Hamburg, Germany
Tel.: +49-40-299 00-0 • Fax: +49-40-299 00-146 •
E-mail: service.de@sperry.ngc.come.
Note For recording the software update procedure see “Test Protocols” in the
appendix of this manual.
vi
NAVIGAT 2200 5023-0125-02/A
1: Introduction
This service manual gives all the information for the software update of
the NAVIGAT 2200 Fiber-Optic Gyrocompass and Attitude Reference
System.
Note Sperry Marine recommends to install and execute the terminal program
on the PC/Notebook prior to service as preparation, before entering the
vessel and undertaking the software update procedure of the NAVIGAT
2200 sensor.
Note If the PC/Notebook does not have a serial interface, an external USB-
RS232-port and USB cable are needed to install a running RS232-inter-
face via the USB interface of the PC/Notebook (example shown in
Figure 1-1).
Software Update CD
NAVIGAT 2200
“lfk200_v2004.sre”
56806/A
20 Jul 2017
Northrop Grumman Sperry Marine B.V.
Woltmanstrasse 19
20097 Hamburg, Germany
phone: +49(0)40 299 00 0
e-mail: service.de@sperry.ngc.com
Figure 1-3:
RS232 download cable
J6: DSUB-HD 44P RS232: DSUB 95
connection details
Download Cable
Note If an error occurs during the software update, the procedure has to be
repeated.
If the error persists, the NAVIGAT 2200 upgrade kit has to be replaced and
the complete procedure must be started anew.
2.1 Preparation
Identify the stock no., revision, type and serial no. of the NAVIGAT 2200
and record all the information into the NAVIGAT 2200 software update
test protocol 5023-0125-03 in the appendix.
Check the housing of the NAVIGAT 2200 for visual damage and record
the result into the NAVIGAT 2200 software update test protocol.
Note Make sure that the NAVIGAT 2200 upgrade kit, stock no. 025974-0000-
000, and a PC/Notebook with a CD drive and serial interface (RS232) /
USB-RS232-port are at place before starting the software update proce-
dure.
Preparation 2-1
5023-0125-02/A NAVIGAT 2200
Note Sperry Marine recommends to install and execute the terminal program
on the PC/Notebook prior to service as preparation, before entering the
vessel and undertaking the software update procedure of the NAVIGAT
2200 sensor.
1. Insert the NAVIGAT 2200 software update CD, stock no. 56806-0000-
000, into the CD drive.
2. Copy the complete folder LFK200V2004 from the CD and copy it to
the following directory e.g. C:\Programme\sw-download (or equiva-
lent).
3. Check the new folder for the following data:
– TTerm Macro File: „Download_sw1050_5100.ttl“
– Download BAT-File: „Download_sw1050_5100.bat“
– file 'comport.ini'
– file LFK-200_Installation.cmd
– icon 'SWDL.ico'
– subdirectory TTERMPRO with file ttermpro.exe
– subdirectory software: v2004 with file „lfk200_v2004.sre“
2-2 Preparation
NAVIGAT 2200 5023-0125-02/A
1. Install the RS232 download cable at the RS232 interface of the PC/
notebook / external USB-RS232-port
2. Install the USB cable and at the J2 connector of the NAVIGAT 2200
sensor unit.
Figure 2-1:
Connection of CAU Power Supply Cable
J1
Power Supply 24 VDC
components
PC with Terminal SW Download Cable RS232 19.2kb
and RS232 Interface J2 NAVIGAT 2200
Sensor Unit
Figure 2-1 shows the schematic connection of the components for the
software update procedure.
Note The installed CAU power supply connection of the NAVIGAT 2200 sensor
unit may stay unchanged for the software update procedure as shown in
figure 2-1.
Figure 2-2:
„COM port not correct“
Figure 2-4:
„Select port settings“
5. Select a baud rate of 115200 (N1) and the other requested serial port
settings and press button OK.
As the NAVIGAT 2200 sensor unit is not powered on, the following
window with no indication of points appears:
Figure 2-5:
„Sensor unpowered /
baud rate incorrect“
6. Switch on the CAU power supply of the NAVIGAT 2200 sensor unit.
With the NAVIGAT 2200 sensor unit powered on and correct baud
rate setting, the following window with indication of points appears:
Figure 2-6:
„Sensor powered /
baud rate correct“
7. Remove the power cable connected to the NG2200 sensor and pre-
pare for pressing „Escape“ within 1 sec after reconnect the power
supply to proceed.
8. Reconnect the power supply and press „Escape“ within 1 sec. to
proceed.
When correctly proceeded („Escape“ pressed within 1 sec. after
reconnection of power supply) the following window
with „LiNav=>“ indicated at the bottom line is indicated:
Figure 2-7:
„Correctly proceeded“
Figure 2-8:
„Incorrectly proceeded“
Figure 2-9:
„Command erase“
Figure 2-10:
„Flash sector erased“
Figure 2-12:
„Ready for download“
13. Drag and drop the SRE file on the indicated window shown in
figure 2-12.
Figure 2-13:
„Download in progress“
Figure 2-14:
„Download successful“
Figure 2-16:
„Main State:
Operational“
Note In case the „Main State: Operational“ window does not show up, the
upload has failed and the software update procedure must be repeated.
16. Select the option „Log...“, to create a log file, as shown in figure 2-17:
Figure 2-17:
„Create log file“
The following window is shown to indicate, that the log file is auto-
matically created and stored in the Tera Term root directory:
Figure 2-18:
„Log file stored“
17. Safe the log file and record it for the verification of the software
update as shown in figure 2-19:
Figure 2-19:
„Safe log file“
18. After the software update is successfully finalized, switch off the
CAU power supply.
19. Switch on the CAU power supply.
The sensor is performing a restart with complete realignment.
Note At the end of the software update procedure, the service personnel is
obliged to send the log file and software update test protocol back to:
Northrop Grumman Sperry Marine B.V. (Representative Office)
Woltmanstr. 19 • D-20097 • Hamburg, Germany
Tel.: +49-40-299 00-0 • Fax: +49-40-299 00-146 •
E-mail: service.de@sperry.ngc.com.
Appendix
A Test Protocols
The following document (blank form) is appended to this manual:
Note After the software update of the NAVIGAT 2200 Gyrocompass, please
return a filled-out copy of the Software Update / Test Protocol to Sperry
Marine for inclusion in the ship’s file.
B Drawings
The following drawings are appended to this manual:
A-1
5023-0125-02/A NAVIGAT 2200
A-2
005023-0125-003/A, 20 Oct 2017; Page 1 of 1
NAVIGAT 2200
Software Update / Test Protocol
Note After the software update of the NAVIGAT 2200, please keep a filled-out
copy of the Test Protocol for inclusion in the ship’s file.
Preparation
Visual inspection of NAVIGAT 2200: m Housing with- m Housing dam- Remarks:
out damage aged
Current data Heading: Pitch: Roll: Remarks:
values: ___________ deg ___________ deg ___________ deg
The S-Record file “lfk200_V2004.sre” is downloaded via drag & drop and m Yes
„LiNav“ is indicated afterwards at the bottom line:
Reset is correctly conducted and "Main state: operational....“ is indicated: m Yes