You are on page 1of 3

Consultant Name: Project No.

CENTRE POINT ENGINEERING CONSULTANCY 219022

Title: PROPOSED MODIFICATION TO EXISTING VILLA


PLOT-279 @ Qurum.

Revisions: Done by: Date: Check by: Date:


0 MMH MARCH- MMH MAR-
2021 2021

Client: Mr. Abdur Redha Mustafa Abdur Redha Sultan

Plot No: -279 ; PH-1….. Location: Al-Qurm, Baushar.

FOR MUNICIPALITY USE:


1.0 INTRODUCTION

PROJECT: Modification to existing Villa; Plot‐279:-

2.0 DESIGN LOADS:


 
FFL= 1.8 KPa 
SOIL BEARING CAPACITY=150  KPa. @ 2.0m depth from EGL 

20 Cm thick Hourdi block =3.30  KN/sq.m..   

LIVE LOAD= 2.0 KPA 

3.0 LOAD COMBINATION: 

1.0 DL + 1.0 LL DL = Dead Load


1.4 DL + 1.6 LL LL = Live Load

4.0 DESIGN CODES: 
 
The proposed structure has been analyzed and designed based on following Design 
Codes. 
 
Building Design Code: 
 BS 8110‐1:1997:Structural use of concrete. Code of practice for design and 
construction. 
 
 
5.0 MATERIAL SPECIFICATIONS 
 
BS‐632: Code for Weight of construction materials. 

BS‐4449: Code for reinforcing steel.  

 
6. LOADING CALCULATION 
Slab Self‐weight = slab thickness*25 KN/Sq.m.     
 
LIVE LOAD = 2 KPa (FOR BED ROOM, FLAT AREAS) 
LIVE LOAD (ROOF)= 1.5 KPa 
 
7.0. SOFTWARE: 
 

STAAD PRO 3d analysis software is used for frame design & analysis.

You might also like