Pipe ID = 40 mm Length of pipe at discharge = 160 m Equivalent Delta P (fittings) = 260 Pipe dia Any equipment in discharge delta P = 1.5 m Surface roughness, e = 0.2 mm Pump Efficiency = 0.6 Viscosity, µ = 0.65 cP Density = 1000 kg/m3 Verticle height to be pumped = 10
Velocity = 0.5017801678 m/s
Re = 30878.779557 e/D = 0.005
1st trial value of (R/ρu2)-0.5 = 16.5
(R/ρu2)-0.5 = 16.506094599
R/ρu2 = 0.0036703826
ΔPf = 15747.365788
(ΔPf)total = 30.462365788
Total pressure to be devloped = 128.56236579
Power required = 0.081065714 kW
Power requird with 60% efficiency = 0.1351095233 kW