Professional Documents
Culture Documents
In order for HAZUS-MH to run properly, your system must meet certain minimum requirements.
Table 1 provides guidance for three software operation levels. System requirements are directly
related to the volume of data to be used in the analysis. For example, reasonable processing times
can be expected when using the “Recommended” computer system if the software operator is
analyzing multiple earthquake scenarios for large cities (population > 500,000). The operator is
assumed to be working on an Intel PC.
INSTALLATION
Before installing HAZUS-MH, the minimum requirements listed in Section 1.1 should be met. If you
are upgrading from HAZUS-MH MR4, read the section at the end of this chapter entitled “Upgrading
from HAZUS-MR4 to HAZUS-MH MR5” at the end of this chapter.
To install HAZUS-MH, follow the steps outlined below.
1. Start Windows and log in with an account with a full Administrator account.
2. Insert “HAZUS-MH Applications DVD” in your DVD-ROM drive.
3. Launch Windows Explorer (if not already running), and navigate to the DVD-DROM drive (d:\
for example).
5. Initially, the setup will install an instance of the HAZUS-MH database (SQL Server Express
2005), shows the requirements screen (Table 1 above) and then the setup program startup
screen (as shown below) will appear. Click on the Next button.
6. Permit program access to anyone who uses the computer or exclude others from accessing
HAZUS program and data. Enter your User Name and Company (or Agency) information.
Select the appropriate installation choice for your study project. Then, click on the Next
button.
7. Select the preferred type of installation shown in Figure 4 and Figure 5. Install the complete
set of HAZUS modules (3 hazard modules and FIT tools), the compact set (3 hazards, no
tools), or select to customize your installation from one or more hazard and tool modules.
Click on the Next button.
8. Specify the directory where you wish HAZUS to be installed. The default directory is
C:\Program files\HAZUS-MH as shown in Figure 6. If you accept the default destination
directory, click on the Next button.
Otherwise click on the Browse button and interactively choose a directory. The window
will appear as shown Figure 7.
You can select or type-in a new directory path and click on OK. You will be returned to the
original “Select Installation Directory” window and the directory that you have selected will
appear in the middle of the window. Click the Next button.
9. Folders will be created for the data files associated with your study regions. Specify the
primary destination directory where you prefer the HAZUS-MH region subfolders to be
created. The default directory is C:\Program files\HAZUS-MH\Regions.
10. If you accept the default destination directory, click on the Next button. Otherwise, click on
the Browse button and interactively choose a directory.
IMPORTANT: Remember the folder specified here since it will be needed later on for copying the
default inventory data.
12. If a custom installation was chosen, the next screen will offer a choice of program modules.
One or more hazard modules must be selected (see Figure 10).
1The Data Inventory DVD that ships with HAZUS-MH contains the default data for the entire US in
compressed format. See the section “Using the Inventory Data” at the end of this chapter for details
on how to un-compress it and make it available to HAZUS-MH.
13. Your next screen will show the installation options you selected and the directory paths you
designated for the program, region data files, and data path.
14. It will take few minutes for the program to install. When the installation is complete, the
dialog box shown below will appear and HAZUS program icon will automatically be created
on your desktop. Click Finish to return Windows. It is recommended that your restart your
machine.
Study regions created in a previous version of HAZUS-MH (HAZUS-MH MR4) cannot be used as is in
HAZUS-MH MR5. If you want to re-use study regions from HAZUS-MH MR4, do the following:
1. Export those regions from HAZUS-MH MR4.
2. Un-install HAZUS-MH MR4.
3. Install HAZUS-MH MR5.
4. Import the previously exported regions in HAZUS-MH MR5. The import routine
will take care of making the needed conversion from the MR4 release to the MR5
release.
5. Select to re-run all the analysis modules.
In order to enter inventory or run an analysis, you must first create a study region. Creating a study
region is discussed in Section 3.1.
To uninstall HAZUS-MH, under Windows XP, launch Control Panel from Start |Settings| Control
Panel as shown in Error! Reference source not found..
From the Control Panel window, double click on Add/Remove Programs as shown in Figure 15.
To uninstall HAZUS-MH, select the ‘Remove’ option and click Next to proceed.
To uninstall HAZUS-MH, under Windows 7, select Start|Control Panel and select the Uninstall a
program option.
Note: The un-installation option requires full-administrative access rights to the computer.
Select HAZUS-MH and right-click (Figure 19Error! Reference source not found.). Select the
Uninstall option from the pop-up menu, and then select ‘Remove’ from the next dialog (Figure 20
belowError! Reference source not found.).
To make partial changes to the modules/features to the original installation (either install
additional features that were not installed initially, or remove features that were installed initially
but are not needed anymore), select the Change option and select the Modify option.
The “Data Inventory” DVD this ships with HAZUS-MH contains the default inventory data for the
entire U.S. The data is compressed as one file per state. Each file is a self-extracting archive and
named simply with the corresponding state code (data for California is in CA.exe, GA.exe for
Georgia, and so on).
To make the default inventory data accessible to HAZUS-MH (when creating new study regions), do
the following:
• Copy the compressed file for the state(s) of interest to the Data Path folder. The Data
Path was specified during setup. By default, this folder is c:\Program Files\HAZUS-
MH\Data Inventory
• Navigate to the folder (via Windows Explorer) and double-click the file (CA.exe for
California for example) to uncompress it.
• (optional) Delete the compressed file (CA.exe in our example) if disk-space is
needed.
If creating a study region within the state of interest generates errors, then confirm that the steps
above where performed correctly.
HAZUS is an ArcGIS-based program with a standard Windows interface that provides a familiar
working environment. Unlike the previous versions, HAZUS resides on top of ArcMap. The only
ArcMap function that has been disabled is table loading. Buttons are added to the ArcMap menu
bar to perform HAZUS hazard risk analysis and loss modeling functions (Figure 21).
The user interface is comprised of a menu bar, tool bar and various screens and windows. These
elements follow standard Windows conventions and allow you to manipulate and analyse data
within HAZUS. This section briefly describes some of the features.
MENU BAR
Functional menus appear alongside the general ArcMap menus: Inventory (Figure 22), Hazard
(Figure 23), Analysis (Figure 24Error! Reference source not found.), and Results (Error!
Reference source not found.). The menu bar is displayed at the top of the screen. Bold menu
items indicate that the items are available; grayed out menu items are not available. The menus
marked with a (*) as described in Table 2 Error! Reference source not found.below are the
menus added by HAZUS to the ArcMap menu.
File Execute standard software actions such as open table, save and
print.
Edit Edit text and features including cut, copy, and paste.
View View data and map display. Zoom in or out. Show the geodatabase
Table of Contents.
Inventory* Add, modify, delete and copy inventory information.
Hazard* Select hazard maps and the scenario event you wish to work with.
Analysis* Modify the analysis data, parameters and assumptions.
Results* Used to view and map analysis results.
Selection Locate multiple inventory items based on criteria you provide, and
search for specific record information.
Tools Basic GIS utilities menu.
Help Help files are available for ArcGIS only. Help files for HAZUS are not
available in the current version, due to budget constraints.
TOOL BAR
A Tool bar is a set of buttons that execute commands by clicking on them. The standard HAZUS tool
bar appears under the menu bar. The tool bar buttons are used for object selection, zooming in or
out, moving around maps, obtaining information, measuring distance and creating points. Details of
the ArcMap toolbars can be found in the ArcGIS Help Manual. Bold buttons indicate that the
buttons are available; grayed out buttons are not available. HAZUS adds two tools to the ArcGIS
toolbar shown in Error! Reference source not found.. The first tool button accesses the startup
dialogue for selection, importing, or creation of an analysis study region. The wand tool allows
switching among the hazard types (earthquake, flood, hurricane) the user has loaded.
The user can expect the following limitations in using the Earthquake Model.
1. SQL Server 2005 Express has a size limit of 4 GB per database, which affects the size of the
region you can analyze. The data for the 3 hazards share the 4 GB limit. To work-around the
4 GB database limit, the full version of Microsoft SQL Server 2005 must be used. Refer to
Appendix N of Users Manual for details.
2. Components of independently developed data sets might not line up on maps, for example,
the placement of bridges and roads, and facilities.
3. Inventory data and subsequently the Level 1 analysis functionality is unavailable for the US
held territories.
SQL Server can often lock memory as a working set. Because memory is locked, HAZUS or other
applications might receive out of memory errors or run slower. To work around this problem,
restart the SQL Server service as follows:
1. Restart your computer by clicking Start, and then click Shut Down. In the “What do
you want the computer to do?” list, click Restart. NOTE: Restarting will close all open
applications, so be sure to save your work before choosing to re-start.
2. Restart SQL Server using the SQL Service Manager. Use the following process to open
SQL Server Service Manager (SQL SSM) and restart the service:
d. Type NET START MSSQL$HAZUSPLUSSRVR and hit Enter. You should see a
message about the service started successfully.